• Title/Summary/Keyword: Mixed calculation

Search Result 223, Processing Time 0.03 seconds

A Dual Mode Ultrasonic Transducer with a PZT Piezoelectric Seramics (PZT 압전 세라믹스를 사용한 2 중 모우드 초음파 변환기)

  • 김연보;노용래;남효덕
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.1-4
    • /
    • 1995
  • The most of conventional ultrasonic transducers are constructed to generate either longitudinal or shear waves, but not both of them. We investigated the mechanism of dual mode transducers that generates both of the longitudinal and shear waves simultaneously with a single PZT element. The study has been aimed to find the desired cut by the examining the piezoelectric properties. Theory predicts that a mixed P/S mode transducer can be constructed using a related Z-cut of a PZT ceramics. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves equally strongly. The results are verified by checking the impedance variation of the element with Finite Element Methods, and chocking the wave form by pulse-echo test simulation. Based upon the theory a rotated Z-cut was prepared and a transducer were fabricated. Validity of the theory calculation is verified through the

  • PDF

Calculation of Stress Intensity Factor in 2-D Using $J_k$-Integral for a Rectilinear Elastic Anisotropic Body (2차원 선형 탄성 이방성 재료에서 $J_k$-적분을 이용한 응력확대계수 계산)

  • An, Deuk-Man;Choi, Chang-Yeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.134-142
    • /
    • 2001
  • The integrals $J_k$(k=1,2) in the rectilinear anisotropis body in 2-D were determined using Lekhnitskii formalism. The relationship between $J_k$ and stress intensity factors are implified by the important equation between elastic compliance. The numerical evaluation of stress intensity factor for the single edge crack in mixed mode is determined by superposing known exact solutions.

  • PDF

Proposal of Approximation Analysis Method for GI/G/1 Queueing System

  • Kong, Fangfang;Nakase, Ippei;Arizono, Ikuo;Takemoto, Yasuhiko
    • Industrial Engineering and Management Systems
    • /
    • v.7 no.2
    • /
    • pp.143-149
    • /
    • 2008
  • There have been some approximation analysis methods for a GI/G/1 queueing system. As one of them, an approximation technique for the steady-state probability in the GI/G/1 queueing system based on the iteration numerical calculation has been proposed. As another one, an approximation formula of the average queue length in the GI/G/1 queueing system by using the diffusion approximation or the heuristics extended diffusion approximation has been developed. In this article, an approximation technique in order to analyze the GI/G/1 queueing system is considered and then the formulae of both the steady-state probability and the average queue length in the GI/G/1 queueing system are proposed. Through some numerical examples by the proposed technique, the existing approximation methods, and the Monte Carlo simulation, the effectiveness of the proposed approximation technique is verified.

Frequency Domain Blind Source Seperation Using Cross-Correlation of Input Signals (입력신호 상호상관을 이용한 주파수 영역 블라인드 음원 분리)

  • Sung Chang Sook;Park Jang Sik;Son Kyung Sik;Park Keun-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.3
    • /
    • pp.328-335
    • /
    • 2005
  • This paper proposes a frequency domain independent component analysis (ICA) algorithm to separate the mixed speech signals using a multiple microphone array By estimating the delay timings using a input cross-correlation, even in the delayed mixture case, we propose a good initial value setting method which leads to optimal convergence. To reduce the calculation, separation process is performed at frequency domain. The results of simulations confirms the better performances of the proposed algorithm.

  • PDF

Mode Analysis of Uncoupled System (언커플 시스템의 모우드 분석 연구)

  • Kim, Jong-Do;Yoon, Moon-Chul;Kim, Seon-Jin;Yang, Bo-Suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.3
    • /
    • pp.35-41
    • /
    • 2010
  • In this study, a mode analysis of uncoupled system was discussed using FRF. The eigen-mode range of FRF analysis is consistent with conventional FFT in spectrum. Also, the numerical response of second order uncoupled system was obtained using the Runge-Kutta Gill method. The displacement, velocity and acceleration response were calculated after numerical analysis and its response was used for the calculation of FRF for uncoupled system. Using the separated and mixed response of 1st and 2nd mode in example, its FRF was analysed for the prediction of the uncoupled systems and its mode shape was calculated by solving the eigen problem.

PCCS Analysis Model for the Passively Cooled Steel Containment

  • Hwang, Y.D.;Chung, B.D.;Cho, B.H.;Chang, M.H.;Jeong, Ik
    • Nuclear Engineering and Technology
    • /
    • v.30 no.1
    • /
    • pp.26-39
    • /
    • 1998
  • The containment pressure and temperature transient analysis computer code CONTEMPT4/MOD5 is modified to incorporate the passive containment cooling models. The correlations are selected from the existing experimental heat transfer correlations to model the natural and mixed convection in annular space between the containment shell and the shield building. The evaporative heat transfer of the water film on the outer shell of the containment is modeled using the correlations derived from the analogy between the heat and mass transfer. The modified code is applied to the Ap600 containment transient analysis for the model verification and the results are compared to the results of GOTHIC calculation done by Westinghouse. Also, d series of parametric sensitivity studies of heat transfer correlations, water film ratio and delay time of the wet cooling on the containment peak pressure and temperature following LOCA are performed for the containment of 1000MWe passive plant, KP1000.

  • PDF

An Analysis on Volumetric Displacement of Gerotor Pump/Motor Using Vane Length (회전날개 길이를 이용한 제로터 펌프/모터의 배제용적에 관한 연구)

  • Kim, S.D.;Kim, D.M.;Ham, Y.B.;Han, C.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.8 no.2
    • /
    • pp.8-16
    • /
    • 2011
  • It is hard and complicated to analytically derive the volumetric-displacement formula of a gerotor pump/motor. Analytical formulas for calculating the volumetric-displacement are derived in this work, which is relatively easy and based upon vane lengths. The vane lengths mean the distances from axis of inner rotor or outer rotor to contact points between inner and outer rotors. Two kinds of formula were studied for two different kinematic motions of rotors. The first one is the case that outer rotor is fixed in space and inner rotor is in mixed motion of planetary revolution and rotation with respect to the spinning axis. And the second is the case that both inner and outer rotors simultaneously rotate. The proposed formula is verified through comparison with volumetric-displacement obtained from numerical CAD calculation.

Mixed reality system using adaptive dense disparity estimation (적응적 미세 변이추정기법을 이용한 스테레오 혼합 현실 시스템 구현)

  • 민동보;김한성;양기선;손광훈
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.171-174
    • /
    • 2003
  • In this paper, we propose the method of stereo images composition using adaptive dense disparity estimation. For the correct composition of stereo image and 3D virtual object, we need correct marker position and depth information. The existing algorithms use position information of markers in stereo images for calculating depth of calibration object. But this depth information may be wrong in case of inaccurate marker tracking. Moreover in occlusion region, we can't know depth of 3D object, so we can't composite stereo images and 3D virtual object. In these reasons, the proposed algorithm uses adaptive dense disparity estimation for calculation of depth. The adaptive dense disparity estimation is the algorithm that use pixel-based disparity estimation and the search range is limited around calibration object.

  • PDF

Reduced Density Matrix Theory for Vibrational Absorption Line Shape in Energy Transfer Systems: Non-Condon Effects in Water

  • Yang, Mi-No
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.439-443
    • /
    • 2011
  • Using the projection operator technique, a reduced density matrix theory for linear absorption spectrum of energy transfer systems is developed for the theoretical absorption line shape of the systems with non-Condon transitions. As an application, we considered a model system of OH vibrations of water. In the present model calculation, the OH vibration modes are coupled to each other via intra-molecular coupling mechanism while their intermolecular couplings are turned off. The time-correlation functions appearing in the formulation are calculated from a mixed quantum/classical mechanics method. The present theory is successful in reproducing the exact absorption line shape. Also the present theory was improved from an existing approximate theory, time-averaged approximation approach.

Implementation of Hardware Circuits for Fuzzy Controller Using $\alpha$-Cut Decomposition of fuzzy set

  • Lee, Yo-Seob;Hong, Soon-Ill
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.200-209
    • /
    • 2004
  • The fuzzy control based on $\alpha$-level fuzzy set decomposition. It is known to produce quick response and calculating time of fuzzy inference. This paper derived the embodiment computational algorithm for defuzzification by min-max fuzzy inference and the center of gravity method based on $\alpha$-level fuzzy set decomposition. It is easy to realize the fuzzy controller hardware. based on the calculation formula. In addition. this study proposed a circuit that generates PWM actual signals ranging from fuzzy inference to defuzzification. The fuzzy controller was implemented with mixed analog-digital logic circuit using the computational fuzzy inference algorithm by min-min-max and defuzzification by the center of gravity method. This study confirmed that the fuzzy controller worked satisfactorily when it was applied to the position control of a dc servo system.