• 제목/요약/키워드: Mitigation strategies

검색결과 197건 처리시간 0.04초

Review of Multifunctional Inverter Topologies and Control Schemes Used in Distributed Generation Systems

  • Teke, Ahmet;Latran, Mohammad Barghi
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.324-340
    • /
    • 2014
  • Recent developments in power electronics technology have spurred interest in the use of renewable energy sources as distributed generation (DG) generators. The key component in DG generators is a grid-connected inverter that serves as an effective interface between the renewable energy source and the utility grid. The multifunctional inverter (MFI) is special type of grid-connected inverter that has elicited much attention in recent years. MFIs not only generate power for DGs but also provide increased functionality through improved power quality and voltage and reactive power support; thus, the capability of the auxiliary service for the utility grid is improved. This paper presents a comprehensive review of the various MFI system configurations for single-phase (two-wire) and three-phase (three- or four-wire) systems and control strategies for the compensation of different power quality problems. The advances in practical applications and recent research on MFIs are presented through a review of nearly 200 papers.

Natural Organic Matter Removal and Fouling Control in Low-Pressure Membrane Filtration for Water Treatment

  • Cui, Xiaojun;Choo, Kwang-Ho
    • Environmental Engineering Research
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2014
  • Natural organic matter (NOM) is a primary component of fouling in low-pressure membrane filtration, either solely, or in concert with colloidal particles. Various preventive measures to interfere with NOM fouling have been developed and extensively tested, such as coagulation, oxidation, ion exchange, carbon adsorption, and mineral oxide adsorption. Therefore, this article aims to conduct a literature review covering the topics of low-pressure membrane processes, NOM characteristics and fouling behaviors, and diverse fouling control strategies. In-depth explanations and discussion are made regarding why some treatment options are able to remove NOM from source water, but do not reduce fouling. This review provides insight for hybridized membrane processes with respect to NOM removal and fouling mitigation in water treatment.

소프트 판정을 이용한 자력복구 적응 판정궤환 채널등화 기법 (Soft Decision Approaches for Blind Decision Feedback Equalizer Adaptation)

  • 정원주
    • 대한전자공학회논문지TC
    • /
    • 제43권8호
    • /
    • pp.69-76
    • /
    • 2006
  • 이 논문에서는 조정 가능한 소프트 판정기를 이용하여 자력복구 판정궤한 채널등화기의 적응 모드를 포착모드와 추적 모드 사이에서 최적화하는 기법들을 제안한다. 제안된 기법들은 주어진 SNR에 따라 소프트 판정기를 최적화하여 DFE를 위한 궤환 신호를 생성하고 그에 따라 자력복구 IIR 필터 적응모드와 DD-LMS 적응모드를 결합한 적응방식을 적용한다. 제안된 기법들은 포착모드와 추적모드 사이의 최적화된 스위칭을 성취할뿐아니라 DFE 에러 propagation을 최소화하는데도 기여한다.

수치지도를 이용한 연안재해지도 작성 방안 (The Methods of Coastal Disaster Mapping Using Digital Map)

  • 정종철
    • 환경영향평가
    • /
    • 제16권5호
    • /
    • pp.373-379
    • /
    • 2007
  • Natural hazards such as typhoon, flood, landslide affect both coastal and inland areas more often according to increasement of severe and unusual weather. To provide adequate coastal disaster mitigation strategies, coastal disaster prevention system using GIS is very useful. Application methods of digital map on this issue was discussed in this study. For developing of coastal disaster prevention system, the data structures related to disaster monitoring is needed to be revised for interdisciplinary framework. To improve the current coastal disaster mapping methods, GIS based new model for coastal disaster mapping was suggested. In this study, coastal GIS showed the attribute data and structures of coastal disaster mapping.

Immune Algorithm Based Active PID Control for Structure Systems

  • Lee, Young-Jin;Cho, Hyun-Cheol;Lee, Kwon-Soon
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1823-1833
    • /
    • 2006
  • An immune algorithm is a kind of evolutional computation strategies, which is developed in the basis of a real immune mechanism in the human body. Recently, scientific or engineering applications using this scheme are remarkably increased due to its significant ability in terms of adaptation and robustness for external disturbances. Particularly, this algorithm is efficient to search optimal parameters against complicated dynamic systems with uncertainty and perturbation. In this paper, we investigate an immune algorithm embedded Proportional Integral Derivate (called I-PID) control, in which an optimal parameter vector of the controller is determined offline by using a cell-mediated immune response of the immunized mechanism. For evaluation, we apply the proposed control to mitigation of vibrations for nonlinear structural systems, cased by external environment load such as winds and earthquakes. Comparing to traditional controls under same simulation scenarios, we demonstrate the innovation control is superior especially in robustness aspect.

GIS를 이용한 농업용수 재이용 활용시스템 개발 (Development of GIS System for Agriculture Reuse of Wastewater Resource)

  • 김해도;이광야;정광근;이종남
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.479-484
    • /
    • 2005
  • A GIS-based integrated system for reuse of effluent from wastewater treatment plants was developed in this study. The GIS-supported program classified attribute data which the effluent's quantity and quality and agricultural thematic map data according to the 5 big river basin area. From the database, showing the spatial variation of the water quality of the effluent, thereby proposing proper mitigation strategies over the watershed. Also, this system enables the users who is going to reuse the reclaimed water for their paddies to provide of all the wastewater treatment plant data and agricultural structures and thematic map data.

  • PDF

Modbus 기반 SCADA 제어 시스템의 보안 취약성 향상에 관한 연구 (A Study on Improving the Security Vulnerabilities of Modbus-Based SCADA Control Systems)

  • 조바니 카가라반;김석수;하경재
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 춘계학술발표논문집
    • /
    • pp.421-424
    • /
    • 2009
  • SCADA control systems and protocols are developed based on reliability, availability, and speed but with no or little attention paid to security. Specifically in Modbus protocol, there are inherent security vulnerabilities in their design. The lack of common security mechanisms in the protocol such as authentication, confidentiality and integrity must be addressed. In this paper, security vulnerabilities of Modbus-based SCADA controls systems will be studied. An in-depth analysis of the message frame formats being sent between master and slave will be discussed to expose the security vulnerabilities. This will enable SCADA users to find ways to fix the security flaws of the protocol and design mitigation strategies to reduce the impact of the possible attacks. Security mechanisms are recommended to further enhance the security of SCADA control systems.

  • PDF

OVERVIEW OF CONTAINMENT FILTERED VENT UNDER SEVERE ACCIDENT CONDITIONS AT WOLSONG NPP UNIT 1

  • Song, Y.M.;Jeong, H.S.;Park, S.Y.;Kim, D.H.;Song, J.H.
    • Nuclear Engineering and Technology
    • /
    • 제45권5호
    • /
    • pp.597-604
    • /
    • 2013
  • Containment Filtered Vent Systems (CFVSs) have been mainly equipped in nuclear power plants in Europe and Canada for the controlled depressurization of the containment atmosphere under severe accident conditions. This is to keep the containment integrity against overpressure during the course of a severe accident, in which the radioactive gas-steam mixture from the containment is discharged into a system designed to remove the radionuclides. In Korea, a CFVS was first introduced in the Wolsong unit-1 nuclear power plant as a mitigation measure to deal with the threat of over pressurization, following post-Fukushima action items. In this paper, the overall features of a CFVS installation such as risk assessments, an evaluation of the performance requirements, and a determination of the optimal operating strategies are analyzed for the Wolsong unit 1 nuclear power plant using a severe accident analysis computer code, ISAAC.

PRECIS를 이용한 우리나라 기후변화 기상자료의 생성 (Generation of Weather Data for Future Climate Change for South Korea using PRECIS)

  • 이관호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.54-58
    • /
    • 2011
  • According to the Fourth Assessment Report of the Inter governmental Panel on Climate Change(IPCC), climate change is already in progress around the world, and it is necessary to start mitigation and adaptation strategies for buildings in order to minimize adverse impacts. It is likely that the South Korea will experience milder winters and hotter and more extreme summers. Those changes will impact on building performance, particularly with regard to cooling and ventilation, with implications for the quality of the indoor environment, energy consumption and carbon emissions. This study generate weather data for future climate change for use in impacts studies using PRECIS (Providing REgional Climate for Impacts Studies). These scenarios and RCM (Regional Climate Model) are provided high-resolution climate-change predictions for a region generally consistent with the continental-scale climate changes predicted in the GCM (Global Climate Model).

  • PDF

Empirical Approach for Evaluating or Upgrading EOP Strategies Using the Decision theory and Simulator

  • Kim, Sok-Chul;Lee, Duck-Hun;Kim, Hyun-Jang
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1998년도 춘계학술발표회논문집(1)
    • /
    • pp.833-837
    • /
    • 1998
  • This paper presents preliminary findings regarding a modeling framework under development for use in a multi-attribute decision model for advanced emergency operating procedures(EOPs). This model provides a means for optimal decision making strategy for advanced emergency operating procedures conceptualizing the dynamic coordination of responsibilities and information in the human system interactions with advanced reactor systems. For the purpose of evaluation of the applicability of this modeling framework, an empirical case study for a post-cooldown strategy during an steam generator tube rupture (SGTR) accident was carried out. As a result, it was found empirically that the multi-attribute decision model is a useful tool for establishing advanced EOPs that reduce the operator's cognitive and decision making burden during the accident mitigation process.

  • PDF