• Title/Summary/Keyword: Mitigation of Switching Acoustic Noise

Search Result 4, Processing Time 0.019 seconds

A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme for Mitigation of Audible Switching Acoustic Noise in Motor Drives (모터 구동 장치의 가청 스위칭 소음 저감을 위한 2상 및 3상 랜덤 펄스 위치 PWM기법의 성능 비교)

  • 정영국;위석오;나석환;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.224-236
    • /
    • 2002
  • In this paper, a comparative study on the performance of two-phase and three-phase randomized pulse position PWM scheme for mitigation of audible switching acoustic noise in motor drives is done. In the randomized Pulse Position PW, each of two-Phase or three-phase PWM Pulses is located randomly in each switching interval. Simulation and experimental efforts were executed to investigate the spread effects of Power spectra of inverter output voltage, waveforms of ripple current and audible switching acoustic noise. As results, two-phase RP% scheme is more effective from the viewpoint of switching loss and ease of implementation while the three-phase RPWM scheme is more effective from the viewpoint of the spread effects of power spectra. Also, from the view point of the audible switching acoustic noise in motor drives, two-phase and three-phase RPW schemes are nearly the same.

Induction Motor Drives with Low Switching Acoustic Noise Based on the Two-Phase Modulated Random Lead-Lag PWM Scheme (2상 변조된 랜덤 Lead-Lag PWM기반의 저 스위칭 소음 유도모터 구동 시스템)

  • 위석오;정영국;임영철;양승학
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.151-164
    • /
    • 2003
  • In this paper, induction motor drives with low switching acoustic noise based on the 2 phase modulated RLL(Random Lead-Lag) PWM is proposed and implemented. The proposed switching method is much bettor than 3 phase modulated RLL-PWM from the standpoint of the broadening effect of the acoustic noise spectrum. Along with the randomization of PWM Pulses, SVM(Space Vector Modulation) is executed in the TMS320C31 DSP(Digital Signal Processor). To verify the validity of the proposed RPWM(Random PWM), the experimental study was tried. The experimental results show that the performance of the proposed method and the 3 phase center-aligned SVM / conventional RLL-PWM are nearly the same from the viewpoint of the constant v/f centrel. But, in case of the proposed 2 phase modulated RLL-PWM, the spectrum characteristics of the voltage and the switching acoustic noise are shown to have better broadening effect than 3 phase modulated one.

A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme (2상 및 3상 변조된 각상별 랜덤 펄스위치 펄스폭 변조기법의 성능비교)

  • Wi Seog-Oh;Lim Young-Cheol;Jung Young-Gook;Na Seok-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.347-354
    • /
    • 2002
  • In this paper, a comparative study on the performance of two-phase and three-phase randomized pulse position PWM scheme for mitigation of audible switching acoustic noise in motor drives Is done. In the randomized pulse position PWM, each of two-phase or three-phase PWM pulses is located randomly in each switching interval. Simulation and experimental efforts were executed to investigate the spread effects of power spectra of inverter output voltage, waveforms of ripple current and audible switching acoustic noise.

  • PDF

Chaotic Double Tent Mapping PWM Scheme for Acoustic Noise Reduction of o Motor Drive) (전동기의 소음 저감을 위한 카오스 2중 텐트 사상 PWM기법)

  • Kim, Jun-Hyeoung;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.71-78
    • /
    • 2008
  • The paper proposes a chaotic double tent mapping PWM scheme for mitigation the acoustic noise of a motor chive. The chaos area ${\lambda}=0.99$ in bifurcation tree of the double tent mapping is used for generating the chaotic numbers. A 80C196 micro-controller is employed for generation of chaotic numbers, and the triangular carrier with chaotic frequency is obtained by using a 80C196 micro-controller and a MAX038 frequency modulator. The experiments are executed with a 1.5[kw] induction motor chive under the 2.5[A] load condition. As results, the experimental results show that the carrier, voltage and 3-D switching noise spectra of the proposed scheme is spread over the chaotic frequency range with no specific frequency concentration. Thereby, the shrill acoustic noise radiated from a motor chive is reduced by the proposed scheme.