• Title/Summary/Keyword: Mitigation Measures

Search Result 297, Processing Time 0.023 seconds

Legislative Study on the Mitigation of the Burden of Proof in Hospital Infection Cases - Focusing on the revised Bürgerliches Gesetzbuch - (병원감염 사건에서 증명책임 완화에 관한 입법적 고찰 - 개정 독일민법을 중심으로 -)

  • Yoo, Hyun Jung
    • The Korean Society of Law and Medicine
    • /
    • v.16 no.2
    • /
    • pp.159-193
    • /
    • 2015
  • Owing to causes such as population aging, increased use of various medical devices, long-term hospitalization of various patients with reduced immune function such as cancer, diabetes, and organ transplant patients, and the growing size of hospitals, hospital infections are continuing to increase. As seen in the MERS crisis of 2015, hospital infections have become a social and national problem. In order to prevent damage due to such hospital infections, it is necessary to first strictly implement measures to prevent hospital infections, while, on the other hand, providing proper relief of damage suffered due to hospital infections. However, the mainstream attitude of judicial precedents relating to hospital infection cases has been judged to in fact shift responsibility over damages due to hospital infections on the patient. In light of the philosophy of the damage compensation system, whose guiding principle if the fair and proper apportionment of damages, there is a need to seek means of drastically relaxing the burden of proof on the patient's side relative to conventional legal principles for relaxing the burden of proof, or the theory of de facto estimation. In relation to such need, the German civil code (Burgerliches Gesetzbuch), which defines contracts of medical treatment as typical contracts under the civil code, and has presumption of negligence provisions stipulating that, in cases such as hospital infections which were completely under the control of the medical care providers, if risks in general medical treatment have been realized which cause violations of the life, body, or health of patients, error on the part of the person providing medical care is presumed, was examined. Contracts of medical treatment are entered into very frequently and broadly in the everyday lives of the general public, with various disputes owing thereto arising. Therefore, it is necessary to, by defining contracts of medical treatment as typical contracts under the civil code, regulate the content of said contracts, as well as the proof of burden when disputes arise. If stipulations in the civil code are premature as of yet, an option may be to regulate through a special act, as is the case with France. In the case of hospital infection cases, it is thought that 'legal presumption of negligence' relating to 'negligence in the occurrence of hospital infections,' which will create a state close to equality of arms, will aid the resolution of the realistic issue of the de facto impossibility of remedying damages occurring due to negligence in the process of occurrence of hospital infections. Also, even if negligence is presumed by law, as the patient side is burdened with proving the causal relationships, such drastic confusion as would occur if the medical care provider side is found fully liable if a hospital infection occurs may be avoided. It is thought that, alongside such efforts, social insurance policy must be improved so as to cover the expenses of medical institutions having strictly implemented efforts to prevent hospital infections in the event that they have suffered damages due to a hospital infection accident, and that close future research and examination into this matter will be required.

  • PDF

Analysis of CO2 Emission Pattern by Use in Residential Sector (가정 부문 이산화탄소 배출량 추이 분석)

  • Yoon, So Won;Lim, Eun Hyouk;Lee, Gyoung Mi;Hong, You Deok
    • Journal of Climate Change Research
    • /
    • v.1 no.3
    • /
    • pp.189-203
    • /
    • 2010
  • The objective of this study is the estimate of $CO_2$ emissions by the energy consumption of functional technology introduced by classifying energy use in households according to functions as well as energy resources. This study also intends to provide the practical basis data in order to establish specific alternatives for GHG mitigation in residential sector with examining the cause analysis affecting $CO_2$ emission increases from 1995 to 2007. The results of this study show a 6.6% increase in the total $CO_2$ from 60,636 thousand tons in 1995 to 64,611 thousand tons in 2007 by using energy in residential sector. Heating is the greatest $CO_2$ emission sector by use, followed electric appliances, cooking, lighting and cooling. Heating sector shows 56.6% reductions from 71.5% in 1995 and as do cooling and electric home appliances, with a 2.4% increase from 0.6% and a 21.8% increase from 14.2% respectively. To analyze factors resulted in $CO_2$ emissions in residential sector, the relevant indicator change rate from 2005 to 2007 was examined. The results find that population, the number of household, housing areas, family patterns, and family income resulted in the $CO_2$ emissions increase in residential sector from 1995 to 2007. On the other hand, carbon intensity and energy intensity contribute to $CO_2$ reduction in residential sector with -2% and -38.7% respectively because of the energy conversion and the improvement of energy efficiency in electronic appliances. This study can be used as a reference when taken account of the reality and considered the introduction of highly effective measures to increase the possibility of mitigation potential in residential sector hereafter.

A Change of the Stream Water Quality by Forest Land Use (임지이용이 계류의 수질변화에 미치는 영향)

  • Ma, Ho-Seop;Goo, So-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.43-48
    • /
    • 2002
  • This study was carried out to clarify the change characteristics of stream water quality by land-use of forest from July to September, 2000 in three stands(Pinus densiflora, Castanea crenata (I), Castanea crenata (II) stand) of Jeongpyeong-ri, Jinju-si, Gyeongnam. The mean pH of rainfall results in acid rain of 5.3. The pH of stream water in three stands was high in order of Pinus densiflora (pH 6.59), Castanea crenata (II)(pH 6.53) and Castanea crenata (I) stand(pH 6.47). The electrical conductivity of stream water was high in order of Castanea crenata (I), Pinus densiflora and Castanea crenata (II) stand. Cations contents of three stands in stream water were high in order of $Ca^{2+}$, $Na^{2+}$, $Mg^{2+}$, $K^+$ and ${NH_4}^+$. But anions of stream water in Pinus densiflora stand and Castanea crenata (II) stand were high in order of ${SO_4}^{2-}$, $Cl^-$ and ${NO_3}^-$. In Castanea crenata (I) stand cations of stream water were high in order of ${NO_3}^-$, ${SO_4}^{2-}$ and $Cl^-$. The level of pH, ${NH_4}^+$, ${NO_3}^-$, $Cl^-$ and ${SO_4}^{2-}$ of stream water in Pinus densiflora stand and Castanea crenata (II) stand reached within the level of domestic use standard for drinking water But the level of ${NO_3}^-$ of stream water in Castanea crenata (I) stand was higher than that of domestic use standard. Therefore, non-point sources like forest watersheds which are fertilizer application lands should be taken to the appropriate mitigation measures.

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

Development of Drought Map Based on Three-dimensional Spatio-temporal Analysis of Drought (가뭄사상에 대한 3차원적 시공간 분석을 통한 가뭄지도 개발)

  • Yoo, Jiyoung;So, Byung-Jin;Kwon, Hyun-Han;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • A drought event is characterized by duration, severity and affected area. In general, after calculating a drought index using hydro-meteorological time series at a station, a drought event is defined based on the run theory to identify the beginning and end time. However, this one-dimensional analysis has limitations for analyzing the spatio-temporal occurrence characteristics and movement paths of drought. Therefore, this study is to define a three-dimensional drought event using a simple clustering algorithm and to develop a drought map that can be used to understand the drought severity according to the spatio-temporal expansion of drought. As a result, compared with the two-dimensional monitoring information to show spatial distribution of drought index, a proposed drought map is able to show three-dimensional drought characteristics inclusing drought duration, spatial cumulative severity, and centroid of drought. The analysis of drought map indicated that there was a drought event which had the affected area less than 10 % while on occations while there were 11 drought events (44 %) which had the affected area more a than 90 % of the total area. This means that it is important to understand the relationship between spatial variation of drought affected area and severity corresponding to various drought durations. The development of drought map based on three-dimensional drought analysis is useful to analyze the spatio-temporal occurrence characteristics and propagation patterns of regional drought which can be utilized in developing mitigation measures for future extreme droughts.

Analyzing the Change of Surface Water and Groundwater Systems Caused by Tunnel Construction in Northern Ulsan City (울산시 북구 지역 터널 굴착에 의한 지표수계 및 지하수계 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Lee, Chung-Mo;Lim, Woo-Ri;Yun, Sul-Min;Park, Heung-Jai
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.81-99
    • /
    • 2018
  • Excessive groundwater discharge by tunneling and tunnel operation can lead to groundwater exhaustion and ground subsidence. Therefore, it is very important to evaluate environmental impact and to establish mitigation measures of the impact related to tunnel excavation based on hydrogeological and modeling approaches. This study examined the depletion of surface reservoirs and valley water due to tunnel excavation through field survey, water quality analysis, tracer test, and groundwater modeling. As a result of field water quality test, the concentration of chemical constituents in groundwater discharge into the tunnel is slightly higher than that of valley water. By the result of laboratory water analysis, both valley water and the groundwater belong to $Ca^{2+}+HCO_3{^-}$ type. Tracer test that was conducted between the valley at the injection point and the tunnel, indicates valley water infiltration into the ground and flowing out to the tunnel, with maximum electrical conductance changes of $70{\mu}S/cm$ in the first test and of $40{\mu}S/cm$ in the second test. By groundwater modeling, the groundwater discharge rate into the tunnel during tunnel construction is estimated as $4,942m^3/day$ and groundwater level recovers in 3 years from the tunnel completion. As a result of particle tracking modeling, the nearest particle reaches the tunnel after 6 hours and the farthest particle reaches the tunnel after 9 hours, similarly to the case of the field trace test.

Impact Analysis of Complex Odor from Pigsty by Using ISCST3 (ISCST3을 이용한 돈사의 복합악취 영향 분석)

  • Kwon, Woo-Taeg;Hong, Sang-Pyo;Lee, Woo-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6602-6609
    • /
    • 2013
  • This study is expected to provide background data for establishing mitigation measures for malodor and for comparing complex odor criteria. The impact of malodor at the afflicted locations was analyzed using Industrial Source Complex Short Term 3 (ISCST3) model, which was recommended by the EPA. The Odor Emission Rates (ODR) for piglets and hogs were predicted based on the average, minimum, and maximum emission rates as classification. The forecasting result of the complex odor modelling of pigsty showed that tolerance limit was exceeded at an adjacent administration building, but tolerance limit was not surpassed at an afflicted location which was within 185m from the pigsty. The ISCST3 modelling of the satisfactory ODR for tolerance limit was accomplished at the administration building. From the prediction of this modelling, maximum emission rates based on 1hr at administration building were 10.59~52.93, 19.05~31.76, and 10.59 $OU/m^3/s/m^2$ at emission rates of 50%, 30%, and 10%. This emission rate was slightly higher than the tolerance limit of 10.00 $OU/m^3/s/m^2$. However, it was inferred that the tolerance limit could be satisfied if the emission rate of 10% was controlled.

Prediction of Loss of Life in Downstream due to Dam Break Flood (댐 붕괴 홍수로 인한 하류부 인명피해 예측)

  • Lee, Jae Young;Lee, Jong Seok;Kim, Ki Young
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.879-889
    • /
    • 2014
  • In this study, to estimate loss of life considered flood characteristics using the relationship derived from analysis of historical dam break cases and the factors determining loss of life, the loss of life module applying in LIFESim and loss of life estimation by means of a mortality function were suggested and applicability for domestic dam watershed was examined. The flood characteristics, such as water depth, flow velocity and arrival time were simulated by FLDWAV model and flood risk area were predicted by using inundation depth. Based on this, the effects of warning, evacuation and shelter were considered to estimate the number of people exposed to the flood. In order to estimate fatality rates based on the exposed population, flood hazard zone is assigned to three different zones. Then, total fatality numbers were predicted after determining lethality or mortality function for each zone. In the future, the prediction of loss of life due to dam break floods will quantitatively evaluate flood risk and employ to establish flood mitigation measures at downstream applying probabilistic flood scenarios.

Long-term Impact of Single Rice Cropping System on SOC Dynamics (동일비료장기연용 논에서 토양유기탄소의 변동)

  • Jung, Won-Kyo;Kim, Sun-Kwan;Yeon, Byung-Yul;Noh, Jae-Seung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.4
    • /
    • pp.292-297
    • /
    • 2007
  • Global warming and climate changes have been major issues for decades andvarious researches have reported their impact on our environment. According to recent researches, increased carbon dioxide ($CO_2$) concentration in the atmosphere is considered as a dominant contributor to global climate changes and thus numerous researches were conducted to control $CO_2$ concentration in the atmosphere. Soil management practices, such as reducing tillage intensity, returning plant residues, and enhancing cropping system have recommended for restoring organic carbon into the soils effectively. However, few studies on soil carbon sequestration have reported for Korean paddy soils. Therefore, evaluation of soil organic carbon (SOC) dynamics in the long-term single rice cropping system is essential in order to find out potential capacity of paddy field as a carbon sink source. The objective of this research was to evaluate SOC dynamics on the long-term single rice cropping system. Research was conducted in the research farm at National Institute of Agricultural Science and Technology, Rural Development Administration, Suwon. Long-term phosphorus and potassium fertilization and lime application didn't significantly affect on SOC compared to controls. We found that SOC contents were increased continually at the long-term composting plots with enhanced rate of carbon storage. In conclusion, continuous incorporation of plant residues (i.e., composting) is recommended to effectively sequester soil carbon for Korean paddy soils. This result implies that continuous composting in a paddy field may contributenot only for increasing SOC in the soils but also for mitigating global warming through reducing carbon dioxide emission into atmosphere. Therefore, we recommend that a strategy or policy measures to encourage farmers to return plant residues continuously for mitigation of global warming as well as soil fertility is being developed.

Analysis of Civil Defense Shelters and Measures (민방위 대피소의 실태분석 및 대책방안)

  • Kim, Tae-Hwan
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.31-31
    • /
    • 2011
  • 1990년 이후 공산체계인 구소련과 동구권이 몰락하고 세계적으로 탈냉전의 변화와 우리의 민주정부 수립 후 햇빛정책 등에도 불구하고 북한은 적화통일을 포기하지 않고 작년 11월에 연평도에 포격을 가하여 민간인과, 군이 2명이 사망하는 사건이 발생 하였다. 또한 북한의 공격은 과거의 포탄공격뿐만 아니라 미사일이나 화생방과 같은 생화학물질 탑재 가능한 공격이 예상된다. 이에 대비 정부에서는 고정시설의 화생방 방호는 일단유사시에 국민의 생명과 재산을 보호하는데 필수요소로서 집단보호개념에 도입하고 있으며, 현재 각 중요 대피시설 및 지자체의 기존 대피시설을 개인방호, 탐지, 제독, 운용절차를 포함한 실태파악 및 재래식 탄을 포함한 통합적인 조치를 마련하고 있다. 작년 2010년 11월 연평도에서의 북한 포격이후 우리는 서해5도나 접경지역 주민과 그리고 근접거리의 서울시민들이 안전하게 포격으로부터 피난 할 수 있는 민방위대피소에 대한 문제점이 대두되고 대책방안을 요구하고 있다. 소방방재청 기준에 따르면 직격(直擊) 핵폭탄을 제외한 화생방, 재래식 무기 공격에 견딜 수 있는 시설은 '1등급 대피시설'인데 서울에는 한 곳도 없다. 고층건물의 지하 2층 이하나 지하철, 터널 같은 2등급 대피시설도 폭격은 견딜 수 있지만 화생방 공격에는 취약하다. 지하상가 등 건축물의 지하층, 지하차도나 보도는 그보다 더 취약한 3등급이며 단독 주택의 지하층처럼 방호 효과가 떨어지는 곳이 4등급이다. 2등급으로 분류된 대피소의 경우 분류만 되어 있을 뿐 장기간 대피시 시민들이 사용 할 수 있는 거주공간이 아닌 임시 대피로서의 역할만 하고 있다. 본 연구에서는 민방위 기본법에 따라 지하에 $3.3m^2$ 당 4명 이상이 대피할 수 있는 규모의 공간을 갖추기만 하면 대피시설로 볼 수 있는 현 문제점과 1등급에서 4등급으로 나뉘어져있는 민방위 대피소와 대피소가 있지만 피난공간으로서의 역할과 구조적으로 안전한가에 대한 국내외 실태 분석을 통하여 분석한 결과 우리는 서해5도 대피시설의 반 이상이 무용지물이고 접경지 또한 피난시에 피난장으로서의 대피소가 난방이나, 구급품과 식구 시설 등이 구비가 되어 있지 않고 대피시설로 지정한곳이 간판이나 안내시설이 없다. 외국의 경우 스위스는 연방정부의 관리책임으로 전쟁이나 핵 확산에 따른 화생방 업무 전담팀을 두고 있으며, 방독면은 개인 방호물자로서 전국민 100% 보유하고, 각가정이나 건축, 시설물의 경우 화생방 표준 대피시설 설치관련 규정 마련 시행하고 있다. 대피시설은 화생방 방호가 가능한 지휘부용 대피시설과 일반 주민대피용 시설을 구분하여 설치운영하고 있으며, 전국에 650만개를 설치하고 있다. 결론은 대피시설이 북한 공경시 피난시설로의 활용방안을 모색 등급구분에 따른 현실적용 수정과 기존 대피소 보강과 재선별이 필요하고, 신축시 설계 표준설계안 그리고 기존의 대피소에 대한 보수, 보강방법 가이드라인과 장기간 거주에 대한 설비구축 등과 국민 대홍보등을 제안하였다.

  • PDF