• Title/Summary/Keyword: Mitigation Devices

Search Result 109, Processing Time 0.032 seconds

Shock absorption of concrete liquid storage tank with different kinds of isolation measures

  • Jing, Wei;Chen, Peng;Song, Yu
    • Earthquakes and Structures
    • /
    • v.18 no.4
    • /
    • pp.467-480
    • /
    • 2020
  • Concrete rectangular liquid storage tanks are widely used, but there are many cases of damage in previous earthquakes. Nonlinear fluid-structure interaction (FSI) is considered, Mooney-Rivlin material is used for rubber bearing, nonlinear contact is used for sliding bearing, numerical calculation models of no-isolation, rubber isolation, sliding isolation and hybrid isolation concrete rectangular liquid storage tanks are established; dynamic responses of different structures are compared to verify the effectiveness of isolation methods; and influences of earthquake amplitude, bidirectional earthquake and far-field long-period earthquake on dynamic responses are investigated. Results show that for liquid sloshing wave height, rubber isolation cause amplification effect, while sliding isolation and hybrid isolation have reduction effect; displacement of rubber isolation structure is much larger than that of sliding isolation with limiting-devices and hybrid isolation structure; when PGA is larger, wall cracking probability of no-isolation structure becomes larger, and probability of liquid sloshing wave height and structure displacement of rubber isolation structure exceeds the limit is also larger; under bidirectional earthquake, occurrence probabilities that liquid sloshing wave height and structure displacement of rubber isolation structure exceed the limit will be increased; besides, far-field long-period earthquake mainly influences structure displacement and liquid sloshing wave height. On the whole, control effect of sliding isolation is the best, followed by hybrid isolation, and rubber isolation is the worst.

Design Patterns for Mitigating Incompatibility of Context Acquisition Schemes for IoT Devices (사물인터넷 컨텍스트 획득 비호환성 중재를 위한 디자인 패턴)

  • La, Hyun Jung;An, Ku Hwan;Kim, Soo Dong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.5 no.8
    • /
    • pp.351-360
    • /
    • 2016
  • Sensors equipped in Internet-of-Thing (IoT) devices are used to measure the surrounding contexts, and IoT applications analyze the contexts to infer situations and provide situation-specific smart services. There are different context acquisition schemes including pulling, pushing, and broadcasting. Most IoT devices support only one of the schemes. Hence, there can be an incompatible issue on data acquisition schemes between applications and devices, and consequently it could result in an increased development cost and inefficiency on application maintenance. This paper presents design patterns which can effectively remedy the incompatibility problem. By applying the patterns, IoT applications with incompatibility can be systematically and effectively developed. And, also its maintainability is expected to increase.

Comparative Simulation of flicker Mitigating Efficiencies of Various Compensating Devices using Matlab/Simulink (Matlab/Simulink를 이용한 무효전력 보상장치의 플리커 저감 효과 연구)

  • Jung, Jae-Ahn;Cho, Soo-Hwan;Jang, Gil-Soo;Kang, Moon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.83-84
    • /
    • 2008
  • Voltage fluctuation, also known as flicker, is a power quality problem caused by nonlinear loads like electric arc furnace. Since it is interpreted as a variation of the supplied electrical energy, it causes the residential customers to feel much annoyed visually through the lamps. Due to the statistical nature of IEC (International Electrotechnical Commission) short-term flicker severity index, Pst, it is not feasible to pre-evaluate the flicker level using the transient power system simulators such as Sim Power System in Matlab/Simulink. So this paper presents not only how to design the Matlab/Simulink IEC flickermeter to yield the Pst value, which considering electric distribution environments of South Korea, but also how to mitigate the voltage flicker at the Point of Common Coupling (PCC). In order to achieve this, the flicker mitigation efficiencies of various compensating devices, such as Static Var Compensator (SVC), STATCOM will be applied and compared. The simulated result demonstrates which compensating equipment is the most efficient method to mitigate the flicker phenomenon.

  • PDF

Cyber attack taxonomy for digital environment in nuclear power plants

  • Kim, Seungmin;Heo, Gyunyoung;Zio, Enrico;Shin, Jinsoo;Song, Jae-gu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.995-1001
    • /
    • 2020
  • With the development of digital instrumentation and control (I&C) devices, cyber security at nuclear power plants (NPPs) has become a hot issue. The Stuxnet, which destroyed Iran's uranium enrichment facility in 2010, suggests that NPPs could even lead to an accident involving the release of radioactive materials cyber-attacks. However, cyber security research on industrial control systems (ICSs) and supervisory control and data acquisition (SCADA) systems is relatively inadequate compared to information technology (IT) and further it is difficult to study cyber-attack taxonomy for NPPs considering the characteristics of ICSs. The advanced research of cyber-attack taxonomy does not reflect the architectural and inherent characteristics of NPPs and lacks a systematic countermeasure strategy. Therefore, it is necessary to more systematically check the consistency of operators and regulators related to cyber security, as in regulatory guide 5.71 (RG.5.71) and regulatory standard 015 (RS.015). For this reason, this paper attempts to suggest a template for cyber-attack taxonomy based on the characteristics of NPPs and exemplifies a specific cyber-attack case in the template. In addition, this paper proposes a systematic countermeasure strategy by matching the countermeasure with critical digital assets (CDAs). The cyber-attack cases investigated using the proposed cyber-attack taxonomy can be used as data for evaluation and validation of cyber security conformance for digital devices to be applied, and as effective prevention and mitigation for cyber-attacks of NPPs.

A Study on the Architectural Characteristics of ¡?Verbena Heights¡?Estate in Hong Kong (홍콩 버비나하이츠(Verbena Heights) 주거단지의 특징에 관한 연구)

  • 이재훈;김남응;김성화
    • Journal of the Korean housing association
    • /
    • v.13 no.3
    • /
    • pp.21-31
    • /
    • 2002
  • The purpose of this study is to find the architectural characteristics of Verbena Heights, super high-rise complex housing, which has been most highly evaluated as a new town development model in Hong Kong, as a successful case of new housing type and sustainable design. The analyzed features of Verbena Heights are as follows; 1) Formation of various open spaces by a creative layout. 2) Enhancement of natural ventilation and daylighting by a linear plan instead of conventional cruciform plans. 3) Applications of integrated facade design for noise mitigation and for sunlight shading. 4) Adoption of energy-efficient devices, use of recyclable materials, and improvement of livability by a sustainable design process. These architectural characteristics provide the high-density high-rise housing with more efficient and comfortable environments for residents. And it is proved that the sustainable design can enhance the quality of dwelling environment.

Soft Decision Approaches for Blind Decision Feedback Equalizer Adaptation (소프트 판정을 이용한 자력복구 적응 판정궤환 채널등화 기법)

  • Chung Won-Zoo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.8 s.350
    • /
    • pp.69-76
    • /
    • 2006
  • In this paper, we propose blind adaptation strategies for decision feedback equalizer (DFE) optimizing the operation mode between acquisitionand tracking modes based on adjustable soft decision devices. The proposed schemes select an optimal soft decision device to generate feedback samples for the DFE at a given noise to signal ratio, and apply corresponding adaptation rules which combine a blind infinite impulse response (IIR) filtering adaptation and the decision-directed least mean squared (DD-LMS) DFE adaptation. These adaptation approaches attempt to achieve not only smooth transition between acquisition and tracking of DFE but also mitigation of error propagation.

Performance Verification of Smart Passive Damping System using MR damper (자기유변유체 감쇠기에 기반한 스마트 수동 감쇠 시스템의 성능 평가)

  • Cho, Sang-Won;Jang, Ji-Eun;Yoon, Woo-Hyun;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.505-512
    • /
    • 2005
  • MR damper is one of the most promising control devices for civil engineering applications to earthquake hazard mitigation. However, a control system including a power supply, controller, and sensors is required to maximize the performance of the MR damper and this complicated control system is not effective to most of large civil structures. This paper proposes and experimentally verified a smart passive damping system using MR(Magnetorheological) dampers by introducing electromagnetic induction(EMI) system as an external power source to MR damper. It is easy to build up and maintain EMI system, because it does not require any control system such as a power supply, controller, and sensors. Numerical simulations using experimental model of EMI system are carried to verify the effectiveness of the proposed EMI system. The performances of smart passive damping system are compared with those of passive and semiactive MR dampers.

  • PDF

Overview of High Performance 3D-WLP

  • Kim, Eun-Kyung
    • Korean Journal of Materials Research
    • /
    • v.17 no.7
    • /
    • pp.347-351
    • /
    • 2007
  • Vertical interconnect technology called 3D stacking has been a major focus of the next generation of IC industries. 3D stacked devices in the vertical dimension give several important advantages over conventional two-dimensional scaling. The most eminent advantage is its performance improvement. Vertical device stacking enhances a performance such as inter-die bandwidth improvements, RC delay mitigation and geometrical routing and placement advantages. At present memory stacking options are of great interest to many industries and research institutes. However, these options are more focused on a form factor reduction rather than the high performance improvements. In order to improve a stacked device performance significantly vertical interconnect technology with wafer level stacking needs to be much more progressed with reduction in inter-wafer pitch and increases in the number of stacked layers. Even though 3D wafer level stacking technology offers many opportunities both in the short term and long term, the full performance benefits of 3D wafer level stacking require technological developments beyond simply the wafer stacking technology itself.

Effect of MDOF structures' optimal dampers on seismic fragility of piping

  • Jung, Woo Young;Ju, Bu Seog
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.563-576
    • /
    • 2015
  • Over the past few decades, seismic retrofitting of structural systems has been significantly improved by the adoption of various methods such as FRP composite wraps, base isolation systems, and passive/active damper control systems. In parallel with this trend, probabilistic risk assessment (PRA) for structural and nonstructural components has become necessary for risk mitigation and the achievement of reliable designs in performance-based earthquake engineering. The primary objective of the present study was to evaluate the effect on piping fragility at T-joints due to seismic retrofitting of structural systems with passive energy-dissipation devices (i.e., linear viscous dampers). Three mid-rise building types were considered: without any seismic retrofitting; with distributed damper systems; with optimal placement of dampers. The results showed that the probability of piping system failure was considerably reduced in a Multi Degree of Freedom (MDOF) building retrofitted with optimal passive damper systems at lower floor levels. This effect of damper systems on piping fragility became insignificant as the floor level increased.

IFC-based Interperable information modeling of tunnel monitoring (상호운용성 확보를 위한 IFC 기반의 터널 계측 정보 모델링)

  • An, Hyun-Jung;Yi, Jin-Hoon;Kim, Hyo-Jin;Lee, Sang-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.613-616
    • /
    • 2008
  • This study presents an IFC-based information model for standardized and integrated information management system of tunnel monitoring. Information items of tunnel monitoring were extracted from the Tunnel Design Standard of Ministry of Construction and Transportation. Then, the information items were compared with components of IFC 2x Edition3 model. Two main entities are added into the IFC model for generic representing of monitoring devices and data. IfcMonitoringElement which is composed of IfcMonitoringLogger and IfcMonitorinSensor is proposed to represent physical information of data loggers and sensors, and relationship between data logger and sensors. Besides, as an additional resource of IFC model, IfcMonitoringData is provided to express measured data from sensors and warning histories.

  • PDF