• Title/Summary/Keyword: Mitigation Device

Search Result 81, Processing Time 0.025 seconds

Overview of High Performance 3D-WLP

  • Kim, Eun-Kyung
    • Korean Journal of Materials Research
    • /
    • v.17 no.7
    • /
    • pp.347-351
    • /
    • 2007
  • Vertical interconnect technology called 3D stacking has been a major focus of the next generation of IC industries. 3D stacked devices in the vertical dimension give several important advantages over conventional two-dimensional scaling. The most eminent advantage is its performance improvement. Vertical device stacking enhances a performance such as inter-die bandwidth improvements, RC delay mitigation and geometrical routing and placement advantages. At present memory stacking options are of great interest to many industries and research institutes. However, these options are more focused on a form factor reduction rather than the high performance improvements. In order to improve a stacked device performance significantly vertical interconnect technology with wafer level stacking needs to be much more progressed with reduction in inter-wafer pitch and increases in the number of stacked layers. Even though 3D wafer level stacking technology offers many opportunities both in the short term and long term, the full performance benefits of 3D wafer level stacking require technological developments beyond simply the wafer stacking technology itself.

Experiment on Settling Behaviour of Fine Mineral Particles (광물성 미립자의 침전거동에 관한 실험)

  • Kim, Jong-Woo
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.1 s.16
    • /
    • pp.13-21
    • /
    • 2005
  • Experiments on settling behaviour of fine-grained particles without destroying the large fragile aggregates were carried out in still water with a CCD (Charged Coupled Device)-Camera. The experiments dealt with the measuring of the vertical concentration profile of cohesive particles with a CCD-Camera and the physico-chemical influences (NaCl, density, temperature and pH value) on the vertical distribution of the concentration. The vertical concentration profile of fine suspended particles (alumina and quartz) was possible up to $20,000\;mg/{\ell}$ with a CCD-Camera. The vertical concentration profile of cohesive sediments was on the decrease because of the increasing initial concentration, temperature and salinity. The vertical concentration profile of alumina was on the decrease quicker than quartz with increasing salinity. Furthermore, the pH value affects the settling behaviour of alumina. At a PH value of 4.2 the settling rate of the particles was very low and on the increase until pH 8.9 because of the aggregation behaviour of particles. From the PH value of 9 the average settling velocity was on the decrease.

Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control

  • Yu, Yang;Royel, Sayed;Li, Jianchun;Li, Yancheng;Ha, Quang
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.943-966
    • /
    • 2016
  • Recently, magnetorheological elastomer (MRE) material and its devices have been developed and attracted a good deal of attention for their potentials in vibration control. Among them, a highly adaptive base isolator based on MRE was designed, fabricated and tested for real-time adaptive control of base isolated structures against a suite of earthquakes. To perfectly take advantage of this new device, an accurate and robust model should be built to characterize its nonlinearity and hysteresis for its application in structural control. This paper first proposes a novel hysteresis model, in which a nonlinear hyperbolic sine function spring is used to portray the strain stiffening phenomenon and a Voigt component is incorporated in parallel to describe the solid-material behaviours. Then the fruit fly optimization algorithm (FFOA) is employed for model parameter identification using testing data of shear force, displacement and velocity obtained from different loading conditions. The relationships between model parameters and applied current are also explored to obtain a current-dependent generalized model for the control application. Based on the proposed model of MRE base isolator, a second-order sliding mode controller is designed and applied to the device to provide a real-time feedback control of smart structures. The performance of the proposed technique is evaluated in simulation through utilizing a three-storey benchmark building model under four benchmark earthquake excitations. The results verify the effectiveness of the proposed current-dependent model and corresponding controller for semi-active control of MRE base isolator incorporated smart structures.

A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution (고속도로 현장별 비점오염 저감시설 선정방안 연구)

  • Lee, Yong-Bok;Choi, Sang-Il;Park, Kye-Su;Seong, Il-Jong;Jung, Sun-Kook
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.6
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

Performance Analysis of Interference-Mitigated Opportunistic Relay System (간섭이 완화된 기회주의적인 중계기 시스템의 성능 분석)

  • Kim, Tae-Wook;Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.45-50
    • /
    • 2014
  • In this paper, we proposed a method using the user mobile device to overcome the interference constraint without building a cooperative communication system. In addition, in order to mitigate interference, we apply the user mobile device selection method, and then exploit power allocation scheme in the user mobile device. The proposed protocol is analyzed in the Rayleigh fading environment, and the performance system is evaluated in terms of the bit error rate and the outage probability. The simulation results showed that when the proposed transmission algorithm is applied, the interference can be mitigated. Further, network overload problems can be solved in the weak channel interference. Therefore, we can increase the network capacity without additional relay.

Development of self-centring energy-dissipative rocking columns equipped with SMA tension braces

  • Li, Yan-Wen;Yam, Michael C.H.;Zhang, Ping;Ke, Ke;Wang, Yan-Bo
    • Structural Engineering and Mechanics
    • /
    • v.82 no.5
    • /
    • pp.611-628
    • /
    • 2022
  • Energy-dissipative rocking (EDR) columns are a class of seismic mitigation device capable of dissipating seismic energy and preventing weak-story failure of moment resisting frames (MRFs). An EDR consists of two hinge-supported steel columns interconnected by steel dampers along its height. Under earthquakes, the input seismic energy can be dissipated by plastic energy of the steel dampers in the EDR column. However, the unrecoverable plastic deformation of steel dampers generally results in residual drifts in the structural system. This paper presents a proof-of-concept study on an innovative device, namely self-centring energy-dissipative rocking (SC-EDR) column, aiming at enabling self-centring capability of the EDR column by installing a set of shape memory alloy (SMA) tension braces. The working mechanism of the SC-EDR column is presented in detail, and the feasibility of the new device is carefully examined via experimental and numerical studies considering the parameters of the SMA bar diameter and the steel damper plate thickness. The seismic responses including load carrying capacities, stress distributions, base rocking behaviour, source of residual deformation, and energy dissipation are discussed in detail. A rational combination of the steel damper and the SMA tension braces can achieve excellent energy dissipation and self-centring performance.

Experimental study of controllable MR-TLCD applied to the mitigation of structure vibration

  • Cheng, Chih-Wen;Lee, Hsien Hua;Luo, Yuan-Tzuo
    • Smart Structures and Systems
    • /
    • v.15 no.6
    • /
    • pp.1481-1501
    • /
    • 2015
  • MR-TLCD (Magneto-Rheological Tuned Liquid Column Damper) is a new developed vibration control device, which combines the traditional passive control property with active controllability advantage. Based on traditional TLCD governing equation, this study further considers MR-fluid viscosity in the equation and by transforming the non-linear damping term into an equivalent linear damping, a solution can be obtained. In order to find a countable set of parameters for the design of the MR-TLCD system and also to realize its applicability to structures, a series of experimental test were designed and carried out. The testing programs include the basic material properties of the MR-fluid, the damping ratio of a MR-TLCD and the dynamic responses for a frame structure equipped with the MR-TLCD system subjected to strong ground excitations. In both the analytical and experimental results of this study, it is found that the accurately tuned MR-TLCD system could effectively reduce the dynamic response of a structural system.

Dynamic response on tunnel with flexible segment

  • Kwak, Changwon;Jang, Dongin;You, Kwangho;Park, Innjoon
    • Geomechanics and Engineering
    • /
    • v.15 no.3
    • /
    • pp.833-839
    • /
    • 2018
  • Dynamic behaviour of a tunnel is one of the most important issues for the safety and it is generally subjected to the seismic response of the surrounding soil. Relative displacement occurred in tunnel lining during earthquake produces severe damage. Generally, it concentrates at the connecting area when two tunnels are connected in the ground. A flexible segment is a useful device for the mitigation of seismic loads on tunnel lining. In this study, 1-g shaking table tests are performed to investigate the acceleration response for the verification of the effect of flexible segment and to determine the optimum location of the flexible segment for connected tunnels. Four different seismic waves are considered; as a result, peak acceleration is reduced to 49% in case that flexible segment is implemented adjacent to connecting area. It also exhibited that the mitigation of acceleration response is verified in all seismic waves. Additionally, 3-dimensional numerical analysis is performed to compare and verify the results. And the numerical results show good agreement to those of the experimental study.

Behavioral Performance Evaluation of the Moment-Resisting Frame Models Equipped with Seismic Damage Mitigation Systems (지진피해 저감 시스템을 설치한 모멘트 프레임의 거동성능 평가)

  • Joe, Yang Hee;Son, Hong Min;Hu, Jong Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.311-322
    • /
    • 2017
  • In this study, the seismic performance of concrete-steel composite moment frame structures equipped with seismic retrofitting systems such as seismic reinforcement, base isolators, and bracing members, which are typical earthquake damage mitigation systems, is evaluated through nonlinear dynamic analyses. A total of five frame models were designed and each frame model was developed for numerical analyses. A total of 80 ground acceleration data were used to perform the nonlinear dynamic analysis to measure ground shear force and roof displacement, and to evaluate the behavioral performance of each frame model by measuring inter-story drift ratios. The analysis results indicate that the retrofitting device of the base isolator make a significant contribution to generating relatively larger absolute displacement than other devices due to flexibility provided to interface between ground and column base. However, the occurrence of the inter-story drift ratio, which is a relative displacement that can detect the damage of the structure, is relatively small compared with other models. On the other hand, the seismic reinforced frame model enhanced with the steel plate at the lower part of the column was found to be the least efficient.

A Study on the Hazard Identification and Risk Mitigation for ATSRX Using Hazard and Operability Study (HAZOP Study를 사용한 ATSRX의 위험원도출 및 리스크 완화에 관한 연구)

  • LEE Jun-Ho;LEE Kang-Mi;KIM Yong-Kyu;SHIN Ducko
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.533-538
    • /
    • 2005
  • In this paper we identity the hazard using HAZOP study for ATSRX which is a subsystem of the ATP system, and we study a safety management method for the mitigation of the risk to the acceptable level. ATSRX is a device that make a train which has a ATP system operate in ATS line. For this ATSRX send a induction signal with ATS system to vehicle controller. Thus ATSRX can be said a safety equipment that makes a train operate safely. In order to identify the hazard for the internal faults in ATSRX system, we employ HAZOP study method which is recommended as hazard identification in IEC 62278, RAMS requirements in railway signal, and also it provide the detail activity in IEC 61882. Thus, in this paper we perform HAZOP study based on ATSRX related standards and using the assessment of the identified hazard we study a method to guarantee the system safety through the change of the design to mitigate the risk to the acceptable level.