• 제목/요약/키워드: Minute volume

검색결과 204건 처리시간 0.026초

한국인(韓國人) 청년남여(靑年男女)의 최대산소섭취량(最大酸素攝取量)에 관(關)한 연구(硏究) - 제(第) I 편(篇) 최대효소섭취양(最大酸素攝取量) 측정치(測定値)의 변리도(變異度)에 관(關)하여 - (Studies on the Maximal Oxygen Intake of the Korean - Part I. Accuracy of the Measurement of Maximal Oxygen Intake -)

  • 이기용
    • The Korean Journal of Physiology
    • /
    • 제1권1호
    • /
    • pp.83-90
    • /
    • 1967
  • In order to evaluate the accuracy of the measurement of maximal oxygen intake (MOI), the MOI in seven subjects was determined 3 to 4 times in each individual. Following a 10 minute warm-up on treadmill (4.3 km/hr with 9 degree grade), the subject was asked to run at a speed of 8.73 km/hr on treadmill for a period of 3 minutes at a given grade which was elevated in a step-wise manner from zero to the level of exhaustion. Following a 3 minute run, the subject was allowed to rest for a period of 3 to 5 minutes. During each period of running, several cardio-pulmonary functions were determined and the range of variability for each measurement was computed. The oxygen consumption during the maximal work load was taken as the MOI. The results may be summarized as follows: (1) The minute volume, the oxygen consumption and the heart rate increased linearly until the grade was elevated to 9 degree above which these values were leveled off. (2) The minute volume and the heart rate during maximal exorcise were $87.4{\pm}8.10\;1/min\;and\;187{\pm}3.7$ per minute, respectively. (3) The maximal oxygen intake which corresponds to the oxygen consumption during maximal exercise was averaged to 3.04 1/min. (4) The coefficient of variance for the maximal oxygen intake was 6.32% while the corresponding values for the minute volume and the heart rate during maximal exercise were 5.22 and 2. 14%, respectively.

  • PDF

교통량예측모형의 개발과 평가 (TRAFFIC-FLOW-PREDICTION SYSTEMS BASED ON UPSTREAM TRAFFIC)

  • 김창균
    • 대한교통학회:학술대회논문집
    • /
    • 대한교통학회 1995년도 제27회 학술발표회
    • /
    • pp.84-98
    • /
    • 1995
  • Network-based model were developed to predict short term future traffic volume based on current traffic, historical average, and upstream traffic. It is presumed that upstream traffic volume can be used to predict the downstream traffic in a specific time period. Three models were developed for traffic flow prediction; a combination of historical average and upstream traffic, a combination of current traffic and upstream traffic, and a combination of all three variables. The three models were evaluated using regression analysis. The third model is found to provide the best prediction for the analyzed data. In order to balance the variables appropriately according to the present traffic condition, a heuristic adaptive weighting system is devised based on the relationships between the beginning period of prediction and the previous periods. The developed models were applied to 15-minute freeway data obtained by regular induction loop detectors. The prediction models were shown to be capable of producing reliable and accurate forecasts under congested traffic condition. The prediction systems perform better in the 15-minute range than in the ranges of 30-to 45-minute. It is also found that the combined models usually produce more consistent forecasts than the historical average.

  • PDF

Sweet Bee Venom 시술이 Rat의 호흡기계에 미치는 영향 (Effects of Sweet Bee Venom on the respiratory system in Rats)

  • 이종영;권기록
    • 대한약침학회지
    • /
    • 제14권3호
    • /
    • pp.47-53
    • /
    • 2011
  • Objectives: This study was performed to analyse the effects of Sweet Bee Venom(SBV-purified melittin supported by G&V Co., the major component of honey bee venom) on the respiratory system in rats. Methods: All experiments were conducted at Biotoxtech Company, a non-clinical studies authorized institution, under the regulations of Good Laboratory Practice(GLP). Male rats of 5 weeks old were chosen for this study and after confirming condition of rats was stable, SBV was administered in thigh muscle of rats in 0.175, 0.35 and 0.7 mg/kg dosage. And checked the effects of SBV on the respiratory system using the whole body plethysmography. And respiratory rate, tidal volume and minute volume of rats were checked after administered SBV (melittin). Results: 1. In the measurement of respiratory rate, there were not observed any significant differences compared with control group. 2. In the measurement of tidal volume, there was not observed any significant differences compared with control group. 3. In the measurement of minute volume, 0.35mg/kg dosage group showed significant differences compared with control group. But we estimated that this result was caused by individual differences. Conclusions: Above findings suggest that SBV seems to be safe treatment in the respiratory system of rats. And further studies on the subject should be conducted to yield more concrete evidences.

Fundamental study on volume reduction of heavy metal-contaminated soil by magnetic separation

  • Konishi, Yusuke;Akiyama, Yoko;Manabe, Yuichiro;Sato, Fuminobu
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권2호
    • /
    • pp.1-6
    • /
    • 2020
  • Large-scale civil engineering works discharge a large amount of soil suspension contaminated with natural heavy metals. Most of the heavy metal ions due to industrial activities and minings are accumulated in the soils and the sediments of lakes and inner bays through the rivers. It is necessary to remove heavy metals from the soils and the sediments, because some of these heavy metals, such as arsenic and cadmium, have significant biological effects even in small amounts. This study proposes a new volume reduction method of the contaminated soils and sediments by superconducting magnetic separation. Our process can remove the specific minute minerals selectively, which adsorbs heavy metals depending on pH. As a fundamental study, the adsorption behaviors of arsenic and cadmium on minute minerals as a function of pH were investigated, and the adsorption mechanism was discussed based on the crystal structure and pH dependence of surface potential in each minute minerals.

개심술후 폐기능 -수술직후 및 장기간의 추이에 대하여- (Pulmonary Function Following Open Heart Surgery -early and late postoperative changes-)

  • 이성행
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.364-374
    • /
    • 1980
  • Twenty-two patients were selected for evaluation of pre-and postoperative pulmonary function. These patients were performed open cardiac surgery with the extracorporeal circulation from March 1979 to July 1980 at the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. Patients were classified with ventricular septal defect 5 cases, atrial septal defect 5 cases, tetralogy of Fallot 5 cases, mitral stenosis 4 cases, rupture of aneurysm of sinus Valsalva 1 case, left atrial myxoma I case, and aortic insufficiency 1 case. The pulmonary function tests were performed and listed: [1] respiratory rate, tidal volume [TV], and minute volume[MV], [2] forced vital capacity [FVC] and forced expiratory volume[FEV 0.5 & FEV 1.0], [3] forced expiratory flow [FEF 200-1200 ml & FEF 25-75%]. [4] Maximal voluntary ventilation [MVV], [5] residual volume [RV] and functional residual capacity[FRC], measured by a helium dilution technique. Respiratory rate increased during the early postoperative days and tidal volume decreased significantly. These values returned to the preoperative levels after postoperative 5-6 days. Minute volume decreased slightly, but essentially unchanged. Preoperative mean values of the forced vital capacity, functional residual capacity and total lung capacity decreased [63.2%, 87.2% & 77.3% predicted, respectively], and early postoperatively these values decreased further [19.6%, 76.0% & 38.0% predicted], but later progressively increased to the preoperative levels. In residual volume, there was no decline in the preoperative mean values [100.9% predicted] and postoperatively the value rather increased [106.3-161.7% predicted]. Forced expiratory volume [FEV 0.5 & FEV 1.0] and forced expiratory flow [FEF 200-1200 ml & FEF 25-75%] also revealed significant declines in the early postoperative period. There was no significant difference in values of the spirometric pulmonary function tests, such as FEF 1.O and FEF 25-75% between successful weaning group [17 cases] extubated within 24 hrs post-operatively and unsuccessful weaning group [5 cases] extubated beyond 24 hrs. Static compliance and airway resistance measured for the two cases during assisted ventilation, however, any information was not obtained. Long term follow-up pulmonary function studies were carried out for 8 cases in 9 months post-operatively. All of the results returned to the pre-operative or to normal predicted levels except FVC, FEV 1.0, and FEF 25-75% those showed minimal declines compared to the pre-operative figures.

  • PDF

The Effect of Neuromuscular Electrical Stimulation on Pulmonary Function, Gait Ability, and Quality of Life in Patients with Chronic Obstructive Pulmonary Disease

  • Kang, Jeong-il;Park, Jun-Su;Jeong, Dae-Keun
    • The Journal of Korean Physical Therapy
    • /
    • 제30권4호
    • /
    • pp.129-134
    • /
    • 2018
  • Purpose: This study aims to investigate the changes in pulmonary function, gait ability, and quality of life when NMES is applied along with CBE and to provide basic clinical data to be used in pulmonary rehabilitation guidelines for patients with COPD to treat patients with severe COPD. Methods: For this study, CBE and NMES of quadriceps femoris on both sides were applied to the experimental group (n=10), and only CBE was applied to the control group (n=10). For a pre-test, a 6-minute walk test was performed, and pulmonary function and health-related quality of life were measured. Moreover, an exercise program was applied to each group for 30 minutes per session, 5 times a week, for 6 weeks. After that, a post-test was conducted the same way as the pre-test. Results: In the within-group comparison, there were significant differences in forced expiratory volume in one second, 6-minute walk test and health-related quality of life between the experimental group and the control group (p<0.01)(p<0.05). In the between-group comparison, the experimental group showed an increase in forced expiratory volume in one second and 6-minute walk test (p<0.05) and showed a decline in health-related quality of life (p<0.05). Conclusion: The 6-weeks NMES program improved health-related quality in patients with severe COPD by increasing expiratory volume by reinforcing the function of quadriceps femoris. This finding implies that NMES could be an alternative mode for improving physical functions of patients with severe COPD, who cannot participate in a breathing exercise program or are reluctant to participate.

A Study on the Tariff Index of Mobile Telephony in Korea

  • Kim, Jin-Ki
    • 한국경영과학회:학술대회논문집
    • /
    • 대한산업공학회/한국경영과학회 2000년도 춘계공동학술대회 논문집
    • /
    • pp.74-77
    • /
    • 2000
  • Since the opening of the mobile telecommunications market to new entrants in 1996, the mobile telecommunications industry in Korea has transformed into a severely competitive market. Although there are numerous methods to evaluate the effects of the competition policy, the most relevant would be to measure the decreased degree of mobile service tariff. Also, after the Introduction of competition in the market, most carriers launched a variety of new tariff plans, which would satisfy the users′ traffic volume and pattern. Therefore, it is necessary to develop a "mobile tariff index" that would collectively consider all the various tariff plans. This paper aims to develop a mobile tariff Index that would accommodate all the various tariff plans provided by mobile carriers. To develop this mobile tariff index, mobile user′s will first be classified by their traffic volume, and then calculate the average tariffs per minute of each group of users, and lastly weight-average those tariffs per minute. And finally, this paper shows the mobile tariff index by considering those averaged tariffs and the carriers′ market shares to reflect the contribution of individual carriers and the users′ traffic volume.

  • PDF

코이어 배지 수경재배에서 관수효율 향상을 위한 급액 제어 (Irrigation Control for Improving Irrigation Efficiency in Coir Substrate Hydroponic System)

  • 유형주;최은영;이용범
    • 생물환경조절학회지
    • /
    • 제24권3호
    • /
    • pp.153-160
    • /
    • 2015
  • 본 연구는 환경오염과 양수분 손실을 주는 비순환식 수경재배에 FDR센서를 이용한 자동관수시스템을 적용할 때 관수효율을 높이기 위한 최적의 최소대기시간을 설정하고자 수행되었다. 실험은 가을과 겨울철에 봄과 여름철에 두 번 수행하였고 가을과 겨울철에는 3분 급액과 최소대기시간을 5분으로 한 3R5F 처리구, 3분 급액과 최소대기시간을 10분으로 한 3R10F 처리구, 5분 급액과 최소대기시간을 15분으로 한 5R15F 처리구를 설정하여 실험하였고 봄과 여름철에는 3분 급액과 최소대기시간을 5분으로 한 3R5F 처리구, 3분 급액과 최소 대기시간을 10분으로 한 3R10F 처리구를 설정하여 실험하였다. 3분 급액은 주당 60mL, 5분 급액은 주당 80mL가 공급되었다. 가을과 겨울철 재배에서 정식 후 62일 까지 주당 급액량은 3R5F (858mL) > 5R15F (409mL) > 3R10F (306mL) 처리 순으로 나타났고 배액률은 3R5F (44%) > 5R15F (23%) > 3R10F (14%) 순으로 나타났다. 정식 후 62일부터 102일 까지는 일일 주당 급액량이 5R15F (888mL)> 3R5F (695mL)> 3R10F (524mL) 순으로 나타났고 이 시기에 배액률은 5R15F에서 가장 높았다. 봄과 여름재배에서는 일일 주당 급액량과 배액율이 3R5F 처리구에서 3R10F 처리구보다 높았다. 두 재배 모두에서 수분이용효율 (WUE)은 3R10F 처리에서 높았다. 따라서 FDR 센서를 활용한 자동화 관수 시스템에서 관수효율을 높이기 위한 최소대기시간은 10분으로 고찰된다.

지하수정호 결합 복합지열시스템의 시범운영 효과분석 (Analysis of Test Operations Effect of Open-Closed Loops Complex Geothermal System Combined with Groundwater Well)

  • 송재용;김기준;이근춘;정교철
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.475-488
    • /
    • 2018
  • 본 연구에서는 지하수 관정을 활용하고 밀폐형-개방형이 결합된 복합지열시스템(CWG 시스템)을 시설재배지에 적용하여 열원측 및 부하측의 열교환량과 투입된 전력량 대비 효율을 평가하였다. 또한, 운전 과정에서의 외기온도 및 시설재배지 온도를 평가하여 복합지열시스템 적용시의 냉난방 효과를 분석하였다. 냉방운전시 열원측 열교환량 평가결과, 약 235 L/min의 지하수가 유입되는 개방형에서 평균 90.0 kW/h, 약 85 L/min의 순환수가 유동하는 밀폐형에서 40.1 kW/h의 열교환량이 발생하였으며, 전체 열교환량은평균 130.1 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 110.4kW/h로 평가되었다. 복합지열시스템의 냉방효율을 분석한 결과, 평균 EER는 5.63으로 분석되었다. 난방운전 시 열원측 열교환량 평가결과, 약 266 L/min의 지하수가 유입되는 개방형에서 평균 60.4 kW/h, 약 86 L/min의 순환수가 유동하는 밀폐형에서 22.4 kW/h의 열교환량이 발생하였으며, 전체 열교환량은 평균 82.9 kW/h로 분석되었다. 부하측에서 실질적으로 전달되는 열교환량은 평균 112.0 kW/h로 평가되었다. 복합지열시스템의 난방효율을 분석한 결과, 평균 COP는 3.92로 분석되었다. 외기온도와 CWG 시스템을 적용한 시설하우스 및 비교 시설하우스 내부온도와의 상관관계를 분석한 결과 30RT 용량의 CWG 시스템 하우스가 비교 하우스에 비해 외기온도 $20^{\circ}C$인 경우 $3.4^{\circ}C$, 외기온도 $25^{\circ}C$인 경우 $6.8^{\circ}C$, 외기온도 $30^{\circ}C$인 경우 $10.1^{\circ}C$, 외기온도 $35^{\circ}C$인 경우 $13.4^{\circ}C$의 온도가 저감되는 것으로 평가되었다. 이러한 결과를 볼 때, 본 시스템을 적용할 경우 일반적으로 외기온도가 $30^{\circ}C$ 이상을 보이는 여름철에 CWG 시스템을 적용하지 않은 시설재배지에 비해 약 $10^{\circ}C$ 이상의 냉방효과가 나타낼 수 있을 것으로 판단된다. 이와 같은 결과는 시설재배지의 복합지열시스템 설계에 활용될 수 있고, 다양한 조건에서의 시험성과와 종합하여 복합지열시스템의 냉난방 효과에 대한 보다 명확한 규명이 가능할 것으로 판단된다.