• Title/Summary/Keyword: Minimum wind speed

Search Result 131, Processing Time 0.03 seconds

Optimal design of a wind turbine supporting system accounting for soil-structure interaction

  • Ali I. Karakas;Ayse T. Daloglua
    • Structural Engineering and Mechanics
    • /
    • v.88 no.3
    • /
    • pp.273-285
    • /
    • 2023
  • This study examines how the interaction between soil and a wind turbine's supporting system affects the optimal design. The supporting system resting on an elastic soil foundation consists of a steel conical tower and a concrete circular raft foundation, and it is subjected to wind loads. The material cost of the supporting system is aimed to be minimized employing various metaheuristic optimization algorithms including teaching-learning based optimization (TLBO). To include the influence of the soil in the optimization process, modified Vlasov and Gazetas elastic soil models are integrated into the optimization algorithms using the application programing interface (API) feature of the structural analysis program providing two-way data flow. As far as the optimal designs are considered, the best minimum cost design is achieved for the TLBO algorithm, and the modified Vlasov model makes the design economical compared with the simple Gazetas and infinitely rigid soil models. Especially, the optimum design dimensions of the raft foundation extremely reduce when the Vlasov realistic soil reactions are included in the optimum analysis. Additionally, as the designated design wind speed is decreased, the beneficial impact of soil interaction on the optimum material cost diminishes.

Relationship between Typhoon and El Niño·La Niña Events (태풍과 엘니뇨·라니냐 현상과의 관계)

  • Seol, Dong-Il
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.611-616
    • /
    • 2013
  • This paper studies relationship between typhoon and El Ni$\tilde{n}$o La Ni$\tilde{n}$a events by using 25 years meteorological data of KMA and JMA. The results are listed below. Annual mean number of typhoon's occurrence in El Ni$\tilde{n}$o event year is 23.9, and that in La Ni$\tilde{n}$a event year is 24.9. The number of typhoon's occurrence decreases in El Ni$\tilde{n}$o event year. Mean central minimum pressure and mean maximum wind speed in El Ni$\tilde{n}$o event year are 959.3hPa and 35.8m/s, and those in La Ni$\tilde{n}$a event year are 965.5hPa and 33.7m/s respectively. Intension of typhoon is stronger in El Ni$\tilde{n}$o event year than La Ni$\tilde{n}$a event year. To be more specific mean central minimum pressure is lower 6.2hPa and mean maximum wind speed is stronger 2.1m/s. This result is closely connected with sea area of typhoon's occurrence. Typhoons in El Ni$\tilde{n}$o event year are more likely to occur in east of 150E and south of 10N, but those in La Ni$\tilde{n}$a event year are more likely to occur in 120-150E and north of 20N. Typhoons which occur in east of 150E and south of 10N can be stronger because the typhoons move in broad sea area of high sea surface temperature in western North Pacific.

Increasing Effect Analysis of the Wind Power Limit Using Energy Storage System in Jeju-Korea (에너지저장장치를 이용한 제주지역 풍력발전 한계용량 증대효과 분석)

  • Kim, Yeong-Hwan;Kim, Se-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2014
  • The Jeju-Korea power system is a small-sized network with a system demand ranging from a autumn minimum of 350MW to a summer peak of 716MW. Because Jeju island is well exposed to north-east winds with high speed, applications to connect to Jeju power system are flooded. Considering physical/environmental constraints, Jeju Self-governing Province has also target for the wind power capacity of 1,350MW by 2020. It amounts to two or three times of Jeju average-demand power and wind power limit capacity announced by Korea Power Exchange (KPX) company. Wind farm connection agreements will be signed to maximize utilization of wind resource. In spite of submarine cable HVDC connected to Korea mainland, Jeju power system is independently operated by frequency and reserve control. This study reevaluates wind power limit based on the KPX criteria from 2016 to 2020. First of all wind power generation limit are affected by off-peak demand in Jeju power system. Also the possibility capacity rate of charging wind power output is evaluated by using energy storage system (ESS). As a result, in case of using 110MWh ESS, wind power limit increases 33~55MW(30~50% of ESS), wind power constraint energy decreases from 68,539MWh to 50,301MWh and wind farm capacity factor increases from 25.9 to 26.1% in 2020.

Dynamic analysis of slack moored spar platform with 5 MW wind turbine

  • Seebai, T.;Sundaravadivelu, R.
    • Ocean Systems Engineering
    • /
    • v.1 no.4
    • /
    • pp.285-296
    • /
    • 2011
  • Spar platforms have several advantages for deploying wind turbines in offshore for depth beyond 120 m. The merit of spar platform is large range of topside payloads, favourable motions compared to other floating structures and minimum hull/deck interface. The main objective of this paper is to present the response analysis of the slack moored spar platform supporting 5MW wind turbine with bottom keel plates in regular and random waves, studied experimentally and numerically. A 1:100 scale model of the spar with sparD, sparCD and sparSD configuration was studied in the wave basin ($30{\times}30{\times}3m$) in Ocean engineering department in IIT Madras. In present study the effect of wind loading, blade dynamics and control, and tower elasticity are not considered. This paper presents the details of the studies carried out on a 16 m diameter and 100 m long spar buoy supporting a 90 m tall 5 MW wind turbine with 3600 kN weight of Nacelle and Rotor and 3500 kN weight of tower. The weight of the ballast and the draft of the spar are adjusted in such a way to keep the centre of gravity below the centre of buoyancy. The mooring lines are divided into four groups, each of which has four lines. The studies were carried out in regular and random waves. The operational significant wave height of 2.5 m and 10 s wave period and survival significant wave height of 6 m and 18 s wave period in 300 m water depth are considered. The wind speed corresponding to the operational wave height is about 22 knots and this wind speed is considered to be operating wind speed for turbines. The heave and surge accelerations at the top of spar platform were measured and are used for calculating the response. The geometric modeling of spar was carried out using Multisurf and this was directly exported to WAMIT for subsequent hydrodynamic and mooring system analysis. The numerical results were compared with experimental results and the comparison was found to be good. Parametric study was carried out to find out the effect of shape, size and spacing of keel plate and from the results obtained from present work ,it is recommended to use circular keel plate instead of square plate.

A Study on Estimation of Energy required for Fin Unfolding (공력면 전개에 필요한 전개 에너지의 추산에 관한 연구)

  • Jung, Suk-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.283-292
    • /
    • 2009
  • Considering an integral equation governing the motion of unfolding fin, an algebraic equation was acquired to get estimated minimum deployment energy required for the successful fin unfolding under the given wind condition. To complete the integration of moment, some approximations had to be introduced particularly to frictional moment and aerodynamic damping for which deployment angular speed of the unfolding fin was modelled as a function of deployment angle only with assumed profile using expected maximum angular speed. Technique for the estimation of the minimum required deployment energy was finalized by introducing the ideal deployment angular speed representing work done by the fin unfolding device alone during fin unfolding and was confirmed by comparing results from simulation with various aerodynamic conditions and profiles of the hinge torque.

Measuring Angular Speed and Angular Acceleration for Automotive Windshield Wiper Pivot (자동차 와이퍼 피봇의 각속도 및 각가속도 측정)

  • Lee Byoungsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.58-65
    • /
    • 2005
  • A method measuring angular speed and estimating angular acceleration of an automotive wind shield wiper pivot with limited resources has been proposed. Limited resources refer to the fact that processes cannot be operated in real-time with a regular notebook running a Microsoft Windows. Also, they refer to the fact that data acquisition cards have only two general purpose counters as many generic cards do. An optical incremental encoder has been employed for measuring angular motion. To measure the angular speed of the pivot, periods for the encoder's output pulses have been measured as the speed is related to the reciprocal of the period. Since only information acquired from one counter channel is the magnitude of the angular speed, sign correction is necessary. Also the information for the exact time when a pivot passes left and right dead points is also missing and the situation is inherent to the hardware setup. To find out the zero-crossing time of the angular speed, a linear interpolation technique has been employed. Lastly, to overcome the imperfection of the mechanical encoders, the angular speed has been curve fitted to a spline. Angular acceleration can be obtained by a differentiation of the angular speed.

Effect of Different Wind-break Net on Reducing Damage of Cold Sea Wind (수도 풍해경감을 위한 방풍강 강목의 효과)

  • 이승필;김상경;이광석;최대웅;김칠용
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.4
    • /
    • pp.352-361
    • /
    • 1990
  • The reducing effect of wind injury was investigated using several wind-break nets in Youngdeok province where cold-wind damage is often occurred during rice growing season. The white-head damage of rice have been often occurred by typhoon during the period between August 15 to September 10 in the cold wind area of the eastern coastal during the last 11 years (1979-1989). This may suggest that the critical period for heading will be by August 15 in the regions. High evaporation coefficient, more than 250 due to typhoon passage over the regions resulted high injury of white head. Generally, the wind injury have been caused by warm and dry westerlies through Fohn apperance in Taebaeg mountains and by cool-humid wind which blows from coast to inland. The frequency of occurrence of the two types of typhoons were 25, 20%, respectively during rice cultivation. The instalation of wind-break net significantly reduced the wind blowing speed, depending on the net mesher with the higher effect in dence net. The distances between the net and cropping area also affect the wind speed: 23% reduction at 1m distance. 34% at 10m and 28% at 20m, respectively. The reducing effect was also observed even at 10 times height of the wind-break net. The instalation of wind-break net gave several effects on climate factor, showing that temperature increased by 0.8$^{\circ}C$(maximum), 0.7$^{\circ}C$(minimum), 0.6$^{\circ}C$(average) : water temperatures increased by 0.5$^{\circ}C$(maximum), 0.6$^{\circ}C$(minimum), 0.5$^{\circ}C$(average) : soil temperature increased 0.4$^{\circ}C$. The earlier heading and increasing growth rate, use of light, culm length, panicle number per hill, spikelet number per panicle, fertility and 1,000 grain weight were observed in the fields with the wind-break nets resulting in 10-15% increase in rice yield using 0.5${\times}$0.5cm nets. The increasing seedlings per hill gave higher grain yield by 13% in the cold wind damage regions of eastern coastals. and the wind-break was more significant in the field without the wind-break net. Wind injury of rice plant in the cold wind regions of eastern coastals in korea could be reduced by selection of tolerant varieties to wind injury, adjustment of transplanting time, and establishment of wind-break nets.

  • PDF

Characteristics of Surface High Ozone Concentration on Pusan Coastal area, Korea (부산 해안지역의 고농도 오존 발생 특성에 관한 연구)

  • 전병일
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.295-302
    • /
    • 2000
  • This study was conducted to investigate the characteristics of surface ozone concentration and occurrence of high ozone concentration using hourly ozone, nitrogen dioxide and meteorological data for 1997~1998 in Pusan coastal area. Monthly mean ozone concentration was the highest at Dongsamdong in Spring(35.4ppb), at Kwangbokdong in Fall(25.1ppb) and the lowest Dongsamdong(22.2ppb) and Kwangbokdong(16.0ppb) in Winter. Relative standard deviation indicating clearness of observation site was 0.42 at Dongsamdong and 0.49 at Kwangbokdong that is similar to urban area. The diurnal variation of ozone concentration of Dongsamdong and Kwangbokdong showed maximum at 1500~1600LST and minimum 0700~0800LST that typical pattern of ozone concentration. In ozone episode period(Sept. 10~15, 1998), diurnal change of ozone concentration was very high, and ozone concentration was related to meteorological parameters such as temperature, relative humidity, wind speed, cloud amount and radiation on a horizontal surface. During the episode days peak ozone concentrations are much higher than the normal values, wind speeds are always lower, and solar radiation is high with the exception of the September episode.

  • PDF

Characteristics on variation of meterological variables during the partial solar eclipse event of 21 May 2012 in Busan (2012년 5월 21일 부분일식 발생 시 부산지역 기상요소의 변화 특성)

  • Jeon, Byung-Il;Kim, Il-Gon
    • Journal of Environmental Science International
    • /
    • v.22 no.7
    • /
    • pp.885-893
    • /
    • 2013
  • The purpose of this study was to analyze the effects of partial solar eclipse on 21 May 2012 in Korea on meteorological variables in Busan. 0800 LST(Local Standard Time) solar radiation was similar or lower than 0700 LST solar radiation, and sunshine duration decreased by 0.2~0.5 hours in Busan and great cities under the influence of the partial solar eclipse. Temperature drop due to the partial solar eclipse was $0.2{\sim}2.0^{\circ}C$, time taken to arrive at maximum temperature after onset of eclipse was 8~62 minutes, and time taken to arrive at minimum temperature after maximum eclipse was -9~17 minutes in Busan. Change of wind speed was negligible as partial solar eclipse occurred in the morning. Soil temperature of 5 cm was minute as well, the increase of soil temperature due to sunset was delayed by more than 1 hour.

A Study on Heatsink Temperature Distribution according to the Installation Angle of a 30W LED Floodlight (30W급 LED 투광등 설치각도에 따른 히트싱크 온도분포에 관한 연구)

  • Lee, Young Ho;Yi, Chung Seob;Chung, Hanshik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.8
    • /
    • pp.24-30
    • /
    • 2019
  • This study investigated the heat dissipation characteristics of a heat-sensitive LED. The results of the empirical test showed that the best temperature intensification was found at 90 with 15-fins, and the heatsink installed perpendicular to the direction of the flow of air was directly connected to the air in the largest heat shield area, leading to the best cooling, and the number of fin also resulted increase in the heat discharge area, resulting in the largest cooling action with 15 fins. It was found that the rate of air flow changed in the range of 1.5m/s to 2.5m/s, but only by a deviation of about $2^{\circ}C$ to $3^{\circ}C$ from the current state of 15 fins at 2.5m/s, and the rate of air flow increased, but the performance of the heat release was not significantly increased. As a result wind speed with minimum air flow conditions of 1.5m/s can greatly contribute to the heat dissipation performance.