• 제목/요약/키워드: Minimum velocity

검색결과 624건 처리시간 0.034초

케미컬루핑 연소를 위한 산소전달입자의 최소유동화속도 및 고속유동층 전이유속에 미치는 압력의 영향 (Effect of Pressure on Minimum Fluidization Velocity and Transition Velocity to Fast Fluidization of Oxygen Carrier for Chemical Looping Combustor)

  • 김정환;배달희;백점인;박영성;류호정
    • 한국수소및신에너지학회논문집
    • /
    • 제28권1호
    • /
    • pp.85-91
    • /
    • 2017
  • To develop a pressurized chemical looping combustor, effect of pressure on minimum fluidization velocity and transition velocity to fast fluidization was investigated in a two-interconnected pressurized fluidized bed system using oxygen carrier particle. The minimum fluidization velocity was measured by bed pressure drop measurement with variation of gas velocity. The measured minimum fluidization velocity decreased as the pressure increased. The transition velocity to fast fluidization was measured by emptying time method and decreased as the pressure increased. Gas velocity in the fuel reactor should be greater than the minimum fluidization velocity and gas velocity in the air reactor should be greater than the transition velocity to fast fluidization to ensure proper operation of two interconnected fluidized bed system.

Annular 유동층 반응기에서 최소유동화 속도 및 압력요동 특성 (Characteristics of Minimum Fluidization Velocity and Pressure Fluctuations in Annular Fluidized Beds)

  • 손성모;김욱영;신익상;강용;최명재
    • Korean Chemical Engineering Research
    • /
    • 제46권4호
    • /
    • pp.707-713
    • /
    • 2008
  • 직경이 0.102 m이고 높이가 2.0 m인 annular 유동층에서 최소유동화 속도 및 압력 요동 특성을 고찰하였다. 기체유속($U_G$), 고체 입자의 크기($d_p$) 그리고 유동층 온도가 최소유동화 속도 및 압력 요동 특성에 미치는 영향을 검토하였다. 본 연구 결과, annular 유동층 내의 압력 요동 자료로부터 구한 상관차원을 유동층 내부의 기체 및 유동 입자의 복합적인 거동을 정량적으로 나타내는 파라미터로 쓸 수 있었으며, 이 상관차원의 값은 기체의 유속, 유동 입자의 크기 그리고 반응기의 온도가 증가함에 따라 증가하였다. 유동층에서 유동입자의 최소유동화 속도를 유동층에서 압력 강하 및 압력 요동자료의 표준 편차를 사용하는 방법뿐만 아니라 압력 요동 자료의 상관차원을 이용하여서도 구할 수 있었으며 이들 각기 다른 방법으로 구한 최소 유동화 속도 값은 서로 매우 유사하였다. Annular 유동층에서 유동 입자의 최소유동화 속도는 유동 입자의 크기가 증가할수록 증가하였으나 유동층의 온도가 증가함에 따라 감소하였다. 본 연구의 범위내에서 annular 유동층에서 최소 유동화 속도를 압력 요동 자료의 상관 차원과 무차원군의 함수로 나타낼 수 있었다.

함진기체의 배출에 미치는 금망 충진물의 영향 (Effects of Screen Packing Materials an Gas Discharge Dust Containing)

  • 홍영호;함영민
    • 한국안전학회지
    • /
    • 제8권4호
    • /
    • pp.120-126
    • /
    • 1993
  • This work was carried out to investigate the effects of solid mass flow rate, mean particle diameter and mesh number of screen packing material on minimum carrying velocity, which defined as the superficial gas velocity of the upper limit of chocking phenomenon. Vertical pneumatic conveying was studied on a 4.6cm 1. D. pipe, 180cm in length. Experiments were performed in both the empty and the screen-packed pipe. It was also examined the effect of superficial gas velocity, solid mass flow, mean particle diameter, and mesh number of packing material on pressure drop. Minimum carrying velocity in screen packed-pipe was lower than that in an empty pipe. besides minimum carrying velocity was decreased with increase in mesh number of screen packing material. The pressure drop In vortical packed-pipe was Increased with superficial gas velocity, mean particle diameter, and mesh number of screen packing material.

  • PDF

액막류의 MHF 점에 관한 실험적 연구 (Experimental Study on Minimum Heat Flux Point of Liquid Film Flow)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.208-213
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increase with increasing the velocity and the subcooling of the liquid film flow.

  • PDF

스윙형 역지밸브의 고장 원인 분석과 열림 특성에 관한 실험적 연구 (Analyses of Failure Causes and an Experimental Study on the Opening Characteristics of Swing Check Valves)

  • 송석윤;유성연
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.15-25
    • /
    • 2005
  • Check valves playa vital role in the operation and protection of nuclear power plants. Check valves failure in nuclear power plants often lead to a plant transient or trip. The analysis of historical failure data gives information on the populations of various types of check valves, the systems they are installed in, failure modes, effects, methods of detection, and the mechanisms of the failures. A majority of check valve failures are caused by improper application. The experimental apparatus is designed and installed to measure the disc positions with flow velocity, Vopen and Vmin for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as Vopen, and Vmin is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, Vmin is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is fully opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the Vmin velocities for 3 inch and 6 inch swing check valves are about 27.3% and 17.5% higher than the Vopen velocities, respectively.

스윙형 역지 밸브의 열림 특성에 관한 실험적 연구 (Experimental Study on the Opening Characteristics for Swing Check Valves)

  • 송석윤;김양석;박성근;홍승열
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.555-561
    • /
    • 2003
  • The experimental apparatus is designed and installed to measure the disc positions with flow velocity, $V_{open}\;and\;V_{min}$ for 3 inch and 6 inch swing check valves. The minimum flow velocity necessary to just open the disc at a full open position is referred to as $V_{open}\;and\;V_{min}$ is defined as the minimum velocity to fully open the disc and hold it without motion. In the experiments, $V_{min}$ is determined as the minimum flow velocity at which the back stop load begins to increase after the disc is idly opened or the oscillation level of disc is reduced below $1^{\circ}$. The results show that the $V_{min}$ velocities for 3 inch and 6 inch swing check valves are about 15.6% and 4.8% higher than the $V_{open}$ velocities, respectively. Although the experiments were done with the stable uniform flow, additional experiments will be performed to determine the effects of the upstream disturbances.

  • PDF

여과재(濾過材)의 종류(種類)에 따른 최소유동상(最小流動狀) 속도(速度) 및 팽창(膨脹)에 관한 연구(硏究) (A Study on the Minimum Fluidization Velocity and Expansion of Various Media)

  • 최승일;최준석
    • 상하수도학회지
    • /
    • 제10권2호
    • /
    • pp.55-69
    • /
    • 1996
  • Backwashing is one of the most important processes in water treatment. Several models have been utilized to predict minimum fluidization velocity and expansion of media. However, it is not unusual that the actual bahavior of media dose not agree well with the prediction. This study has investigated the applicability of models in predicting the minimum fluidization velocity of sand media. However even the better model has predicted minimum fluidization velocity 1.1 to 1.8 times higher than actual fluidization velocity. The expansion rate of sand media was inspected. It is found that the actual expansion rate was greater than the predicted. In this study condition, use of $d_{10}$ instead of $d_{60}$ was better to predict the expansion of media. On the contrary to the sand media, the actual expansion of anthracite media was less than that predicted. Sometimes it is reported that the dual media has been overflown during backwashing and mixed severely at the interface. It is because the grain size distribution of anthracite has not been selected properly. The numerical values for media expansion found in this study could be referred as the useful data in operating and/or designing filter media.

  • PDF

0.5 MWth 케미컬루핑 연소시스템 적용을 위한 산소전달입자의 수력학 특성 및 고체순환 특성 (Hydrodynamics and Solid Circulation Characteristics of Oxygen Carrier for 0.5 MWth Chemical Looping Combustion System)

  • 류호정;김정환;황병욱;남형석;이도연;조성호;백점인
    • 한국수소및신에너지학회논문집
    • /
    • 제29권6호
    • /
    • pp.635-641
    • /
    • 2018
  • To select the operating condition of 0.5 MWth chemical looping combustion system, minimum fluidization velocity, transition velocity to fast fluidization and solid circulation rate were measured using mass produced new oxygen carrier (N016-R4) which produced by spray drying method for 0.5 MWth chemical looping combustion system. A minimum fluidization velocity decreased as the pressure increased. The measured transition velocity to fast fluidization was 2.0 m/s at ambient temperature and pressure. The measured solid circulation rate increased as the solid control valve opening increased. We could control the solid circulation rate from 26 to $93kg/m^2s$. Based on the measured minimum fluidization velocity and transition velocity to fast fluidization, we choose appropriate operating conditions and demonstrated continuous solid circulation at high pressure condition (5 bar-abs) up to 24 hours.

최소분산 자기동조 PID제어기 (A self tuning PID controller with minimum variance)

  • 조원철;전기준
    • 제어로봇시스템학회논문지
    • /
    • 제2권1호
    • /
    • pp.14-20
    • /
    • 1996
  • This paper presents a self tuning method of a velocity type PID controller for minimum or non-minimum phase systems with time delays. The velocity type PID control structure is determined in the process of minimizing the variance of the auxilliary output, and self tuning effect is achieved through the recursive least square algorithm at the parameter estimation stage and also through the Robbins-Monro algorithm at the stage of optimizing a design parameter. This method is simple and effective compared with other existing methods[1,2]. Numerical examples are included to illustrate the procedure and to show the performance of the control system.

  • PDF

액막류의 MHF점에 관한 실험적 연구

  • 김영찬;서태원
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.960-965
    • /
    • 2001
  • The minimum heat flux conditions are experimentally investigated for the subcooled liquid film flow on the horizontal plate. The experimental results show that the minimum heat flux point temperature becomes higher with the increase of the velocity and the subcooling of the liquid film flow. However, the effect of distance from the leading edge of the heat transfer plate on the minimum heat flux is almost negligible. Also, the experimental results show that the propagation velocity of wetting front increases with increasing the velocity and the subcooling of the liquid film flow.

  • PDF