• 제목/요약/키워드: Minimum Standard of Treatment

검색결과 94건 처리시간 0.029초

일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화 (The change of air lead concentrations in litharge making and smelting industries)

  • 최재욱;김남수;조광성;함정오;이병국
    • 한국산업보건학회지
    • /
    • 제20권1호
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

Moisture Absorption and Desorption Properties of Douglas Fir, Hinoki, Larch, Plywood, and WML Board in Response to Humidity Variation

  • PARK, Hee-Jun;JO, Seok-Un
    • Journal of the Korean Wood Science and Technology
    • /
    • 제48권4호
    • /
    • pp.488-502
    • /
    • 2020
  • In this study, the moisture absorption and desorption properties presented by the Health-Friendly Housing Construction Standards of South Korea were compared using the wood of three tree species (Douglas-fir, Hinoki, Larch) and two types of wood-based materials(Plywood, WML Board). The national standards for functional building materials present that the amounts of moisture absorption and desorption should be at least 65g/㎡ on average, respectively according to the test method under KS F 2611:2009. Therefore, in this study, the moisture absorption/desorption properties of materials with no treatment (Control), with punching, and with surface stain finishing and the moisture absorption/desorption property improvement effects of the treatments were compared and analyzed. According to the results of this study, it was evaluated that all five types of wood and wood-based materials tested did not satisfy the amount of moisture absorption/desorption of at least 65g/㎡, which is the performance standard for moisture absorption/desorption functional building materials, indicating that untreated wood and wood-based materials cannot be applied as functional finishing materials according to the Health-Friendly Housing Construction Standards. The surface stain finishing greatly reduced the moisture absorption and desorption rates of the materials, and the amounts of moisture absorbed and desorbed were also shown to decrease by at least two times on average. When the surfaces of the materials were punched with Ø4mm holes at intervals of 20 mm, the moisture absorption/desorption areas increased from 18% to 51%, and this increase was shown to be capable of increasing the amounts of moisture absorbed/desorbed by 29% on average at the minimum, and 81% on average at the maximum. The effects of punching were shown to be identical even in cases where the materials were stain finished. For the application of wood or wood-based materials as eco-friendly, health-friendly, and moisture absorption/desorption functional building materials hereafter, it is judged that new physical and chemical improvement studies should be conducted, and treatment methods should be developed.

입효산(立效散)의 Methicillin-Resistant Staphylococcus aureus에 대한 항균활성에 관한 연구 (Antibacterial Effect of Ipyo-san against Methicillin-Resistant Staphylococcus aureus)

  • 윤재홍;최연주;정승현;신길조
    • 대한한방내과학회지
    • /
    • 제34권3호
    • /
    • pp.278-288
    • /
    • 2013
  • Objectives : Methicillin-resistant Staphylococcus aureus (MRSA) has a cephalosporin and beta-lactam antibiotic-resistant strains. MRSA is one of the major pathogens causing hospital infection and the isolation ratio of MRSA has gradually increased. Consequently, increased resistance to antibiotics is causing serious problems in the world. Therefore, there is a need to develop alternative antimicrobial drugs for the treatment of infectious diseases. Methods : The antibacterial activities of Ipyo-san were evaluated against 2 strains of MRSA and 1 standard Methicillin-susceptible staphylococcus aureus (MSSA) strain by using the disc diffusion method, minimal inhibitory concentrations (MIC) assay, colorimetric assay using MTT test, checkerboard dilution test and time-kill assay performed under dark. Results : The MIC of Ipyo-san water extract against S. aureus strains ranged from 1000 to $2,000{\mu}g/ml$, so we confirmed that it had a strong antibacterial effect. Also, the combinations of Ipyo-san water extract and conventional antibiotics exhibited improved inhibition of MRSA with synergy effect. We suggest that Ipyo-san water extract against MRSA has antibacterial activity so it has potential as alternatives to antibiotic agents. For the combination test, we used Triton X-100 (TX) and DCCD for measurement of membrane permeability and inhibitor of ATPase. As a result, antimicrobial activity of Ipyo-san water extract was affected by the cell membrane. Conclusions : We suggest that the Ipyo-san water extract lead the treatment of bacterial infection to solve the resistance and remaining side-effect problems that are the major weak points of traditional antibiotics.

감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로 (A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design)

  • 한수하;윤형진
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제24권3호
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.

Low doses of amitriptyline, pregabalin, and gabapentin are preferred for management of neuropathic pain in India: is there a need for revisiting dosing recommendations?

  • Kamble, Sanjay Vasant;Motlekar, Salman Abdulrehman;D'souza, Lyndon Lincoln;Kudrigikar, Vinay Nanda;Rao, Sameer Eknath
    • The Korean Journal of Pain
    • /
    • 제30권3호
    • /
    • pp.183-191
    • /
    • 2017
  • Background: Current therapy for the treatment of neuropathic pain is often unsatisfactory. Considerable variation in treatment pattern still exists in spite of availability of sufficient literature from various guidelines. Recent Indian market data suggested that the utilization (sale) of drugs such as amitriptyline, pregabalin, and gabapentin was more for low-dose unit packs than that of the high-dose unit packs, raising the belief that these drugs are prescribed at a lower dose than is actually recommended in the guidelines. To test this hypothesis, a survey was conducted across speciality throughout the country to observe the prescription pattern of these drugs amongst the health care providers in India. Methods: Three hundred fifty survey forms were distributed of which 281 forms were included for analysis. Results: It was observed that the commonly used initiation and maintenance dose for amitriptyline, pregabalin, and gabapentin was 5-10 mg/day, 50-75 mg/day, and 100-300 mg/day, respectively. The reason to select the lower dosages was to have a balancing effect to achieve good efficacy with minimum side effects. Care-givers reported no side effects/not many side effects as a reason in 22.2%, 16.88%, and 23.86% patients with amitriptyline, pregabalin, and gabapentin, respectively. Sedation and giddiness were commonly reported with all three drugs. Conclusions: Commonly prescribed drugs for management of neuropathic pain, such as amitriptyline, pregabalin, and gabapentin are preferred at lower doses in Indian clinical settings. Acceptable efficacy and low tolerance to the standard dosage is believed to be the reason behind the prescribed dose.

불확도를 고려한 Class I 부정교합 환자의 측방두부방사선영상 계측값 (Lateral Cephalometric Measurements of Class I Malocclusion Patients with Uncertainty)

  • 이지민;송지수;현홍근;김영재;김정욱;장기택;이상훈;김호재;조효민;신터전
    • 대한소아치과학회지
    • /
    • 제45권1호
    • /
    • pp.65-74
    • /
    • 2018
  • 본 연구의 목표는 측방 두부계측방사선 사진의 분석에 이용되는 소프트웨어의 소급성 확보와 측정값의 불확도를 계산하는 것이다. 또한 이를 이용해 소아에서 교정치료를 위한 계측값의 참고 표준을 얻기 위한 기반을 마련하고자 하였다. 교정치료를 위해 서울대학교 치과병원 소아치과에 내원한 6세에서 13세 사이 환아 중 1급 부정교합으로 진단 받은 환아 100명의 데이터를 수집하였다. 소급성 확보를 위해 방사선 촬영이 가능한 phantom 장비를 제작하였으며, 현재 사용중인 계측 소프트웨어를 이용하여 phantom 장비의 길이와 각도를 측정하여 소프트웨어의 교정값을 계산하였다. 불확도 계산을 위해 100명의 측방두부방사선영상 계측값과 반복측정에 의한 불확도와(A형 불확도) 최소분해능과 두부의 위치에 의한 불확도를(B형 불확도) 계산하였다. 이를 통해 합성표준불확도를 얻었으며 최종적으로 확장불확도를 계산하였다. 본 연구 결과 현재 사용중인 측방두부방사선사진 계측 프로그램이 높은 정확성과 신뢰도를 가지는 것을 확인하였다. 또한 교정값을 이용하여 계측값을 교정하였으며, 6 - 13세 한국인 소아에서의 교정계측치의 불확도를 계산하여 1급 부정교합 환아의 교정계측값의 95% 신뢰도를 가지는 분포범위를 제시하였다.

잔류 항균물질에 대한 미생물학적 간이검사법의 검출감도 비교 (Comparison of Detectable Levels for Screening Residual Antibacterial Agents by Bioassay)

  • 정승희;김진우;손상규
    • 한국수산과학회지
    • /
    • 제32권3호
    • /
    • pp.256-260
    • /
    • 1999
  • 본 연구는 EEC 4-plate법과 그 변법 그리고 식품공전상 간이검사법으로써 어류질병의 예방 및 치료에 사용되는 28종류의 항균물질에 대한 최저 검출한계를 서로 비교하여 어체내 잔류 항균물질의 최적 간이검사법 (bioassay)으로서의 유효성을 확인하고자 하였다. 식품공전상 간이검사법은 PCs에 뛰어난 검출감도를 나타내었으며 AGs에 대하여 좋은 감도를 보였으나 TCs, MLs, NFs, QNs에 대해서는 낮은 검출감도를 나타내었다. 한편, SAs에 대하여는 대단히 저조한 감도를 보였다. EEC 4-plate변법은 TCs에 대하여 우수한 검출감도를 나타내었다. EEC 4-plate법 및 그 변법은 PCs, MLs, NFs, QNs, SAs에 대하여 상대적으로 높은 검출감도를 나타내었다. 시험법들은 모두 CMs에 대하여는 검출감도가 낮았다. 결국 EEC 4-plate 변법이 여러계열의 항균물질에 대해 검출감도가 뛰어나고 항균활성의 범위가 넓어 어체내 잔류 항균성물질을 가장 유효하게 스크리닝할 수 있는 간이검사법으로 확인되었다.

  • PDF

폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가 (The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer)

  • 홍미란;김철종;박수연;최재원;표홍렬
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.149-159
    • /
    • 2016
  • 목 적 : 폐암환자의 호흡동조 방사선 치료 계획 시 호흡 훈련 전후 RPM 신호와 횡격막 위치 변화를 분석하여 호흡 훈련의 유용성을 평가하고자 한다. 대상 및 방법 : 2016년 4월부터 8월까지 호흡 동조 방사선 치료를 받는 환자 11명을 대상으로 호흡 훈련을 시행하였고 동시에 RPM 신호 및 횡격막 영상을 획득하였다. 호흡 훈련은 총 3단계로 1단계 자유 호흡 상태의 신호 획득, 2단계 호흡 신호 가이드를 통한 1차 호흡 신호 획득, 3단계 설명과 반복 훈련으로 규칙성과 안정을 유도한 최종 호흡 신호를 획득 하였다. 각 단계의 흡기와 호기시 RPM 신호와 투시 영상의 횡격막 위치의 평균값, 표준편차, 최대값, 최소값을 구하고, 이를 1단계 값으로 표준화 하여 2, 3단계를 상대분포 백분율(%)로 변환하여 환자의 호흡 변화와 내부 움직임을 분석 함으로써 각 환자의 호흡훈련 유용성을 평가 하였다. 결 과 : RPM 신호와 횡격막 진폭을 측정한 뒤, 1단계를 100%으로 표준화하여 각 단계의 평균값과 표준편차의 오차 평균을 구하였다. 그 결과, 3단계 최종호흡 획득 시 진폭의 상대평균 및 표준편차 모두 감소가36.4%, 표준편차만 감소가 18.2%, 진폭만 감소가 36.4%로 나타났으며, 횡격막 영상의 위치 측정 시 3단계에서 전체 81.8%의 환자에게서 상대평균 진폭 값이 30% 감소함을 보였다. 그러나 모든 환자들에게서 2단계 대비 3단계의 RPM 신호와 횡격막 진폭이 각각 평균 52.6%, 42.1% 감소함을 보였다. 또한, RPM 신호와 횡격막 영상 진폭 차이의 연관성은 2번 10번 환자를 제외하고 각각 1, 2, 3단계 움직임의 패턴이 상관관계를 보였다. 결 론 : 호흡 동조 방사선치료에서 호흡 훈련을 시행하였을 때 최적화된 호흡 주기를 유도할 수 있었으며, 모의 호흡 훈련을 치료 전 시행함으로써 불규칙적인 호흡에 의한 환자의 호흡을 제어해 폐의 움직임을 예측 가능 하게 해주는 효과를 기대할 수 있었다. 궁극적으로는 방사선 치료의 체계적 오류를 최소화해 보다 정확한 치료를 기대할 수 있어 호흡 훈련이 유용하다고 할 수 있겠다.그러나 본 연구는 치료 전 호흡 훈련을 시행한 자료를 바탕으로 분석한 연구로 제한되어 있으며 추후 실제 CT 계획과 치료 시 획득한 자료를 가지고 검증하는 것도 필요할 것으로 사료된다.

  • PDF

흡착제를 이용한 침강 HNS 처리 및 현장적용 가능성 연구 - 현장 처리를 위한 활성탄소 활용 조건 검토 및 제안 - (Feasibility of Activated-Carbon Adsorbent to Sequester Sunken Hazardous and Noxious Substances (HNS))

  • 최기영;김창준;김혜은;정준모;황호진;이문진
    • 해양환경안전학회지
    • /
    • 제26권7호
    • /
    • pp.858-863
    • /
    • 2020
  • 본 연구에서는 활성탄소를 이용하여 해양환경으로 유출된 침강 HNS를 현장에서 대응하기 위한 기술 개발을 목적으로, 활용 가능한 활성탄소의 조건을 검토하고 예상 소요량을 산출하였다. 입자 크기별 7종의 활성탄소들을 대상으로 침강 속도를 측정하였고, 침강 HNS로 분류된 클로로포름(CHCl3)에 대한 흡착용량을 실험실 규모 실험(lab-scale test)으로 측정하였다. 또한 7종 활성탄소들에 대하여 유해물질함량과 용출 실험을 실시하여 용출된 유해물질 함량을 정량 분석하였다. 평균 침강속도(Mean particle-settling velocity)는 0.5~8 cm/sec의 범위로 8-20 mesh 경우를 제외하고 입자의 크기가 클수록 침강속도가 빨랐으며, 클로로포름에 대한 흡착효율은 대체로 입자가 작을수록 표면적이 넓어져 증가되었다. 또한 현장 투입 후 2차 오염가능성 확인을 위한 유해물질함량과 용출 실험 실험에서 >100 mesh의 활성탄소는 전함량분석결과가 아연(Zn)과 비소(As)가 수처리제기준보다 높고, 용출실험결과에서도 크롬(Cr), 아연(Zn), 비소(As)가 다른 활성탄소에 비해 높은 농도로 용출되었다. 흡착효율, 침강속도, 유해성분 용출량 등을 종합적으로 고려하여 현장 처리 적용 가능한 활성탄소는 20-60, 20-40, 2mm&down mesh 이었으며, 흡착용량을 최우선으로 판단하여 투입물량을 계산하면 최소 현장 투입 물량은 각각 0.82, 0.90, 1.28 ton/㎘ 이다.

멜론 수경재배 시 배액제로화가 근권환경 및 수량에 미치는 영향 (Effects of Non-drainage Hydroponic Culture on Growth, Yield, Quality and Root Environments of Muskmelon (Cucumis melo L.))

  • 장영호;황연현;안철근;윤혜숙;안재욱;임채신;손길만
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.348-353
    • /
    • 2012
  • 폐양액을 발생시키지 않는 배액제로형 수경재배기술을 개발하기 위하여 멜론 수경재배 시 표준배액량(배액률 20~40%), 배액최소화(5~10%), 배액제로화(0%) 등으로 배액량을 달리하여 근권환경 변화와 재배기간 동안의 급액량과 배액량, 과실품질 등에 미치는 영향을 구명하였다. 재배기간 동안 표준배액에서는 함수률 60~70%, EC $1.5{\sim}2.5dS{\cdot}m^{-1}$ 수준으로 되어 근권환경이 적정범위로 유지되었다. 배액제로 처리에서는 함수률 30~50%, EC $2{\sim}6dS{\cdot}m^{-1}$로 변화가 심하였으나 과실품질에는 크게 영향을 미치지 않았다. 1과중은 표준배액 처리가 1,990g인데 비하여 배액제로 처리는 1,836g으로 다소 가벼웠으나 규격품(1.8~2.0kg) 생산에는 문제가 없었다. 상품과율은 처리 간에 차이가 없었으며 당도는 배액제로처리가 배액최소와 표준배액에 비하여 높았다. 주당 배액량은 표준배액 처리가 27,718mL, 배액최소 처리가 15,769mL, 배액제로 처리가 2,346mL 이었다. 폐양액 발생량은 표준배액 처리가 10a당 $83.2m^3$로 양액공급량의 34.5% 인데 비하여 배액제로 처리는 $7.0m^3$로 나타나 멜론 수경재배에서 배액제로화의 가능성을 확인할 수 있었다.