• Title/Summary/Keyword: Minimum Flow Rate

Search Result 334, Processing Time 0.028 seconds

Study of Ejector System for Pressure Recovery of Chemical Lasers (화학레이저 압력회복용 이젝터 시스템 연구)

  • 김세훈;김춘택;권세진
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.49-53
    • /
    • 2003
  • In this study, the geometric design parameters of ejector system were investigated. The critical parameters were primary nozzle area ratio, 2nd-throat cross sectional area and 2nd-throat L/D ratio. At every geometry cases, primary pressure and secondary pressure were measured simultaneously according to secondary mass flow rate. From the results, the ejector starting pressure, unstarting pressure and minimum secondary flow pressure were found and we got the effect of geometric parameters to ejector performance and the way to optimal design of ejector system for chemical lasers operating. Also the experiments of changing secondary flow temperature were carried out.

  • PDF

Seepage and Slope Stability Analysis on the Site of Debris-flow at Jinbu Area (진부지역 토석류발생 사면에 대한 침투 및 사면안정 연계해석)

  • Jun, Kyoung-Jea;Yune, Chan-Young;Seo, Heung-Seok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.369-376
    • /
    • 2009
  • Field investigation was performed right after the occurrence of debris flow at Jinbu area. Geomorphic and geotechnical characteristics were investigated and rain fall data were collected. Based on these data, seepage and slope stability analysis was performed to verify the behavior of ground water and factor of safety of the slope according to the rainfall intensity and time. As a results, the minimum value of factor of safety achieved in long time after the moment of maximum precipitation rate. And it is confirmed that the factor of safety is susceptible to ground water level rather than rainfall intensity.

  • PDF

Design of Centrifugal Impeller for Passenger Car by Flow Field Analysis (유동장 해석을 통한 승용차 원심 회전차의 형상 설계)

  • Lee, Dong-Ryul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.49-55
    • /
    • 2011
  • For the purpose of the enhancement of the air conditioner performance and fuel effciency, several cases of centrifugal impeller for passenger car air conditioner have been numerically analyzed by changing central angle of blades and length of outlet for shape optimization of the impeller. Commercial CFD program Fluent 6.3.26 has been used to compute velocity, temperature, pressure and turbulence intensity that can lead numerous results. The central angles of two blades and three cases of outlet length led 4~12% and 3.5~6.4% differences of velocity and flow rate, respectively. The velocity distribution near the blade surface was axisymmetric and had a maximum value of 22.19 m/s and velocity of the vertical direction of the impeller showed linear increase with horizontal direction. At case 3 of oultet length, there existed a a minimum pressure value of -133320 Pa.

Assessment of Design Method about Sanitary Sewer Network according to RDII and Established Scenario (RDII발생 및 기존 시나리오에 따른 오수간선 네트워크 설계방법 검토)

  • Kim, Jungryul;Oh, Jeill
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.4
    • /
    • pp.367-374
    • /
    • 2016
  • In this study, the RDII impact on sewer designing in the upstream monitoring area (A site) was considered. Based on the long-term (1/1/2011~12/31/2011) rainfall and flow data consisting of 10-min interval sampling in the nearby design area (B site), the maximum RDII/DWF ratio was selected. The sewer network system at B site was evaluated by the Manning equation. Scenario 1 considering the hourly maximum flow with respect to the flow velocity showed that none of the sewer pipes satisfied the minimum flow velocity condition (0.6 m/s), and 40 pipes did not achieve half of the velocity condition. In scenario 2 considering I/I, 1 the pipes satisfied 0.6 m/s, and 35 pipes showed 0.3 m/s. Scenario 3 reflected the effect of RDII. Velocities in 26 pipes were less than 0.3 m/s, and 4 pipes satisfied the velocity condition. With respect to the allowance rate, 17 pipes were shown to have more than 99%, and none of the pipes satisfied less than 95% of the allowance rate in scenario 1. In scenario 2, 17 Ed: Per the Table pipes showed more than 99% and one pipe showed less than 95%. In scenario 3, 16 pipes showed more than 99% of the allowance rate, and 19 pipes showed less than 95%. Based on these results, it is predicted that deposition would occur due to the slow flow velocity; however, capacity would not be a problem.

Performance of Airlift Pumps for Water Circulation and Aeration (물 순환 및 에어레이션용 에어리프트 펌프의 성능)

  • OH Se-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.25 no.6
    • /
    • pp.529-537
    • /
    • 1992
  • Airlift pumps were tested to evaluate their pumping and aeration capacities. The pumps were 34.5 inch long made of 2, 3, 4 and 6 inch nominal diameter PVC pipes. An one hp air blower was used to supply the air. The air-flow rate was measured by an anemometer type air-flow meter and air pressure was level changes in a water tank from which water was pumped. Aeration by the pumps was tested by the standard aeration test method with the center of pump outlet positioned 3 inches above water surface. Oxygen concentrations in water were measured to determine aeration rate. As pumping head increased by water level draw-down in the tank water flow decreased while air flow increased. The reduction rate of water flow was higher with 4 and 6-inch pumps. Small pumps showed very minor changes in the reduction. Aeration rates were similar among 3, 4, and 6 inch pumps. With one hp air blower 6-inch pump at the minimum pumping head achieved the best performance in terms of water circulation.

  • PDF

Modelling of Thermal Discharge Performance for Ice-on-coil Type Ice-Storage Tank (관외착빙형 빙축열조의 방열성능 모델링)

  • Lee, Sang-Ryoul;Lee, Kyoung-Ho;Choi, Byoung-Youn;Han, Seong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.280-285
    • /
    • 2001
  • This paper presents a modelling of thermal discharge performance for a static ice-on-coil ice-storage tank. Through the present study, discharging characteristics were examined with the existing results of theoretical and numerical heat transfer analyses. Also, an experiment was conducted to obtain a real set of discharge performance. The thermal effectiveness, the ratio of the actual heat transfer rate to the maximum possible heat transfer rate, decreased when the stored energy decreased during discharging period. And the effectiveness increased as the coolant flow rate through the storage increased, of which increasing rate decreased abruptly near the maximum and the minimum stored energy. An empirical correlation was obtained from the experimental and the numerical analysis data.

  • PDF

Effects of Nucleation Layer's Surface Roughness on the Quality of InP Epitaxial Layer Grown on GaAs Substrates (Nucleation Layer의 표면 거칠기가 GaAs 기판 위에 성장된 InP 에피층의 품질에 미치는 영향)

  • Yoo, Choong-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.8
    • /
    • pp.575-579
    • /
    • 2012
  • Heteroepitaxial InP films have been grown on GaAs substrates to study the effects of the nucleation layer's surface roughness on the epitaxial layer's quality. For this, InP nucleation layers were grown at $400^{\circ}C$ with various ethyldimethylindium (EDMIn) flow rates and durations of growth, annealed at $6200^{\circ}C$ for 10 minutes and then InP epitaxial layers were grown at $550^{\circ}C$. It has been found that the nucleation layer's surface roughness is a critical factor on the epitaxial layer's quality. When a nucleation layer is grown with an EDMIn flow rate of 2.3 ${\mu}mole/min$ for 12 minutes, the surface roughness of the nucleation layer is minimum and the successively grown epitaxial layer's qualities are comparable to those of the homoepitaxial InP layers reported. The minimum full width at half maximum of InP (200) x-ray diffraction peak and that of near-band-edge peak from a 4.4 K photoluminescence are 60 arcmin and 6.33 meV, respectively.

Estimation of Unprotected Left-Turn Saturation Flows (비보호 좌회전 포화유률 추정)

  • 김경환
    • Proceedings of the KOR-KST Conference
    • /
    • 1998.10a
    • /
    • pp.236-244
    • /
    • 1998
  • When the capacity and traffic operation at signalized intersections are analyzed in Korea, the unprotected left-turn saturation flow rate, which is an important parameter for the analysis, is estimated form the USHCM model. thus, exact analysis of the left-turn is not possible because of the difference of traffic environments between two contries. In order to improve this problem, it is undertaken in this study to develop techniques for the estimation of unprotected left-turn saturation flows based on Korean drivers' data. As study intersections, signalized or unsignalized intersections on the 6, 4 and 2 lane streets are selected. the data for the saturation flow measurement and gap-acceptance behavior analysis are inputed in a notebook computer on the sites. The critical acceptance gaps of the 6, 4, and 2 lane streets are analyzed to be 6.0 secs, 4.6 secs, and 4.3 secs respectively. the average minimum headway of the left-turn vehicle was observed to be 2.6 secs. As the model to estimate unportected left-turn saturation flows, the drew model is recommended for 6 and 4 lane streets, and a graph is suggested for the 2-lane street. As the values of the parameters of the Drew model, the 2.6 secs of this study is recommended for the average minimum headway of the left-turn. But, the critical acceptance gap varies according to the approach speed of opposing traffic and driver population, it requires field survey to measure the gap of an intersection; however, the values of the gaps studied in this study may be used for the general intersections in urban area in Korean.

  • PDF

Reduction of Power Consumption for Constant Pressure Control of Variable Swash Plate-type Piston Pump by Varying the Pump Speed (가변 용적형 사판식 피스톤 펌프의 회전 속도 조절에 의한 정압 제어 소비 동력 절감)

  • Kim, J.H.;Hong, Y.S.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.53-60
    • /
    • 2014
  • This paper proposes a control scheme to reduce the power consumption of a variable displacement swash-plate type piston pump supplying oil to a valve-controlled hydraulic cylinder at constant pressure. Whenever flow rate demand was absent, the swash plate angle and the pump speed were changed to the minimum values required to compensate for the internal leakage flow. In response to command signals, the pump speed was changed in proportion to the absolute mean value of the speed component for position commands. At the same time, a pressure regulator was activated to maintain constant system pressure by precisely adjusting the pump speed with the swash plate angle fixed at the maximum. The conventional system consisting of a pressure-compensated variable displacement type pump is driven at a constant speed of 1,800rpm. By comparison, computer simulation and experimental results showed that idling power at stand-by status could be reduced by up to 70% by reducing the pump speed from 1,800rpm to 300rpm and the swash plate angle to the minimum.

Discharge Computation from Float Measurement in Vegetated Stream (부자 측정 시 식생을 고려한 유량산정에 관한 연구)

  • Lee, Tae Hee;Jung, Sung Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.307-316
    • /
    • 2019
  • Development of vegetation in stream channel increases resistance to flow, resulting in increase in river stage upon flood and affecting change in stage-discharge relationship. Vegetation revealed in stream by water level reaching a peak and then declined upon flood is mostly found as prone. Taking an account of flow distribution with the number of vegetation, prone vegetation layer might be at height where discharge rate is zero (0) (Stephan and Guthnecht, 2002). However, there is a tendency that flow rate is overestimated when applying the height of river bed to flow area with no consideration of the height of vegetation layer in flow rate by float measurement. In this study, reliable flow measurement in stream with vegetation was calculated by measuring the height of vegetation layer after flood and excluding the vegetation layer-projected area from the flow area. The result showed the minimum 4.34 % to maximum 10.82 % of flow deviation depending on the scale of discharge. Accordingly, reliable velocity-area methods would be determined if vegetation layer-projected area in stream is considered in flow rate estimation using the flow area during the flood.