• Title/Summary/Keyword: Minimally invasive dentistry

검색결과 62건 처리시간 0.029초

Management of the paralyzed face using temporalis tendon transfer via intraoral and transcutaneous approach Temporalis tendon transfer

  • Choi, Ji Yun;Kim, Hyo Joon;Moon, Seong Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제40권
    • /
    • pp.24.1-24.6
    • /
    • 2018
  • Temporalis tendon transfer is a technique for dynamic facial reanimation. Since its inception, nearly 80 years ago, it has undergone a wealth of innovation to produce the modern operation. Temporalis tendon transfer is a relatively minimally invasive technique for the dynamic reanimation of the paralyzed face. This technique can produce significant and appropriate movement of the lateral oral commissure, more closely mimicking the normal side. The aim of this article is to review the technique of temporalis tendon transfer involving transferring of the coronoid process of the mandible with the insertion of the temporalis tendon via intra-oral and transcutaneous approach.

Corticotomy for orthodontic tooth movement

  • Lee, Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제44권6호
    • /
    • pp.251-258
    • /
    • 2018
  • Corticotomy was introduced as a surgical procedure to shorten orthodontic treatment time. Corticotomy removes the cortical bone that strongly resists orthodontic force in the jaw and keeps the marrow bone to maintain blood circulation and continuity of bone tissues to reduce risk of necrosis and facilitate tooth movement. In the 21st century, the concept of regional acceleratory phenomenon was introduced and the development of the skeletal anchorage system using screw and plate enabled application of orthopedic force beyond conventional orthodontic force, so corticotomy has been applied to more cases. Also, various modified methods of minimally invasive techniques have been introduced to reduce the patient's discomfort due to surgical intervention and complications after surgery. We will review the history of corticotomy, its mechanism of action, and various modified procedures and indications.

Immediate implant placement in fresh extraction sockets

  • Lee, Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권1호
    • /
    • pp.57-61
    • /
    • 2021
  • Immediate implant placement (IIP) in fresh extraction sockets exhibits similar survival and success rates to delayed implant placement in healed sockets. Several advantages of IIP involve shortened total treatment time, reduction of the number of invasive surgeries, and subsequent reduction of patient discomfort due to lack of additional surgeries. The major shortcomings in IIP, however, include the inability to obtain early bony support, presence of a gap between the extraction socket and fixture, and the inability to cover the fixture with soft tissue, leading to increased risk of infection and implant loss. When IIP is performed, atraumatic or minimally traumatic extractions, conservation of the septal bone in molars, minimal flap elevation or flapless surgery, bone grafting the gap between the fixture and the extraction socket, and coverage with soft tissue or a membrane must be considered.

Volumizing Threads (Jamber) in the Midface and Managing Side Effects: Clinical Cases

  • Kyu-Ho Yi;Soo-Yeon Park
    • Archives of Plastic Surgery
    • /
    • 제51권4호
    • /
    • pp.350-355
    • /
    • 2024
  • The clinical application of polydioxanone (PDO) threads, traditionally utilized for tissue lifting, is now being explored for its volumizing effects in midface rejuvenation. The novel approach involves employing PDO volumizing threads to achieve physical augmentation akin to a "solid filler." The study introduces a more convenient insertion method for these threads, prioritizing ease and efficacy. Clinical cases demonstrate the efficacy of volumizing threads in addressing midface concerns, such as nasolabial folds and midcheek grooves. Additionally, the integration of volumizing threads to provide support in sagging areas is examined for achieving natural-looking enhancements. While highlighting positive outcomes, potential side effects like thread protrusion are addressed, along with strategies for their mitigation. Volumizing threads are presented as a suitable procedure for patients wary of traditional fillers or seeking subtle enhancements, with the recommendation of combining them with cog threads for those desiring more pronounced changes in facial contour. In summary, volumizing thread offers a minimally invasive alternative with fewer side effects for midface rejuvenation.

재건용금속판을 따라 하악골편 전이 골신장기를 이용한 하악골 연속성의 회복 (RESTORATION OF MANDIBULAR CONTINUITY USING MANDIBULAR TRANSPORT DISTRACTOR GUIDED BY RECONSTRUCTION PLATE)

  • 김성민;정지훈;김한석;김지혁;박영욱;이종호
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권5호
    • /
    • pp.429-438
    • /
    • 2007
  • Transport distraction osteogenesis has been introduced recently to correct skeletal malformations and discrepancies in the maxillofacial area. To reconstruct 3-dimensitonal mandibular shape, this transport distraction can be considered with the use of reconstruction plate. A 23-years-old male having unilateral mandibular body and angle defects, who had been operated of partial mandibular resection due to unicystic ameloblastoma, was treated by transport distraction procedures with ThreadLock transport $distractor^{(R)}$ (KLS Martin Co., Germany) through the rail of reconstruction plate (Osteomed Co., USA). After being distracted 35 mm defect from mandibular angle to body, and consolidated for 16 weeks, allogenic bone graft on docking site was performed with removal of transgingival pin. For more than 13 weeks follow up period after consolidation period, gradual increase of radiopacity in the radiographic examination was shown, and the curved mandibular continuity according to the reconstruction plate was made firmly. These transport distraction osteogenesis in the mandible was able to be considered as the good and minimally invasive technique for the reconstruction of mandibular discontinuity. Young patient was also very satisfactory for these results.

측두하악관절의 비정복성 관절원판변위 환자에 대한 관절강 세정술의 임상효과 : 증례보고 (Clinical Effect of Arthrocentesis for Patients with Disc Displacement without Reduction of Temporomandibular Joint : Report of Cases)

  • 김철;김영준
    • Journal of Oral Medicine and Pain
    • /
    • 제31권2호
    • /
    • pp.177-183
    • /
    • 2006
  • 관절강세정술은 통상의 보존적 치료법에 실패한 측두하악관절장애 환자에서 합병증의 위험성이 높은 침습적인 외과적 수술법에 대신하여 첫 번째로 고려될 수 있는 치료법이다. 본 증례의 환자들은 측두하악관절의 비정복성 관절원판변위로 진단되어 지속적인 교합안정장치치료, 행동요법치료, 물리치료, 약물치료 등의 보존적 치료에도 불구하고 심한 관절동통과 하악운동범위의 제한을 호소하였다. 따라서 보존적 치료법에 잘 반응하지 않는다고 판단하여 반복적인 관절강세정술을 시행하였고, 시술직후 유의한 동통감소, 하악운동범위의 개선과 함께 양호한 치료경과를 나타냈다. 관절강세정술은 최소의 침습성을 지니는 가장 보존적인 외과적 술식으로서 통법의 보존적 치료에 반응하지 않는 비정복성 관절원판변위 환자를 상기 증례와 같이 적절히 선택한다면 측두하악관절장애의 동통과 기능제한에 효과적인 보조적 치료법이라고 생각된다.

Treatment and retention of relapsed anterior open-bite with low tongue posture and tongue-tie: A 10-year follow-up

  • Seo, Yu-Jin;Kim, Su-Jung;Munkhshur, Janchivdorj;Chung, Kyu-Rhim;Ngan, Peter;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.203-216
    • /
    • 2014
  • The purpose of the current report is to present 6-year long-term stability and 10-year follow-up data for an adult patient who was treated with a tongue elevator for relapsed anterior open-bite. The 19-year-old male patient presented with the chief complaint of difficulty in chewing his food. Collectively, clinical and radiographic examinations revealed an anterior open-bite, low tongue posture, and tongue-tie. The patient opted for orthodontic treatment alone, without any surgical procedure. A lingual frenectomy was recommended to avoid the risk of relapse, but the patient declined because he was not experiencing tongue discomfort. Initial treatment of the anterior open-bite with molar intrusion and tongue exercises was successful, but relapse occurred during the retention period. A tongue elevator was used for retreatment, because the approach was minimally invasive and suited the patient's requirements regarding discomfort, cost, and time. The appliance changed the tongue posture and generated an altered tongue force, which ultimately resulted in intrusive dentoalveolar effects, and a subsequent counterclockwise rotation of the mandible. The results showed long-term stability and were maintained for six years through continual use of the tongue elevator. The results of this case indicated that a tongue elevator could be used not only as an alternative treatment for open-bite, but also as an active retainer.

In-vitro performance and fracture strength of thin monolithic zirconia crowns

  • Weigl, Paul;Sander, Anna;Wu, Yanyun;Felber, Roland;Lauer, Hans-Christoph;Rosentritt, Martin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.79-84
    • /
    • 2018
  • PURPOSE. All-ceramic restorations required extensive tooth preparation. The purpose of this in vitro study was to investigate a minimally invasive preparation and thickness of monolithic zirconia crowns, which would provide sufficient mechanical endurance and strength. MATERIALS AND METHODS. Crowns with thickness of 0.2 mm (group 0.2, n=32) or of 0.5 mm (group 0.5, n=32) were milled from zirconia and fixed with resin-based adhesives (groups 0.2A, 0.5A) or zinc phosphate cements (groups 0.2C, 0.5C). Half of the samples in each subgroup (n=8) underwent thermal cycling and mechanical loading (TCML)(TC: $5^{\circ}C$ and $55^{\circ}C$, $2{\times}3,000cycles$, 2 min/cycle; ML: 50 N, $1.2{\times}10^6cycles$), while the other samples were stored in water ($37^{\circ}C/24h$). Survival rates were compared (Kaplan-Maier). The specimens surviving TCML were loaded to fracture and the maximal fracture force was determined (ANOVA; Bonferroni; ${\alpha}=.05$). The fracture mode was analyzed. RESULTS. In both 0.5 groups, all crowns survived TCML, and the comparison of fracture strength among crowns with and without TCML showed no significant difference (P=.628). Four crowns in group 0.2A and all of the crowns in group 0.2C failed during TCML. The fracture strength after 24 hours of the cemented 0.2 mm-thick crowns was significantly lower than that of adhesive bonded crowns. All cemented crowns provided fracture in the crown, while about 80% of the adhesively bonded crowns fractured through crown and die. CONCLUSION. 0.5 mm thick monolithic crowns possessed sufficient strength to endure physiologic performance, regardless of the type of cementation. Fracture strength of the 0.2 mm cemented crowns was too low for clinical application.

Minimal invasive horizontal ridge augmentation using subperiosteal tunneling technique

  • Kim, Hyun-Suk;Kim, Young-Kyun;Yun, Pil-Young
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.41.1-41.6
    • /
    • 2016
  • Background: The goal of this study was to retrospectively evaluate the prognosis of minimal invasive horizontal ridge augmentation (MIHRA) technique using small incision and subperiosteal tunneling technique. Methods: This study targeted 25 partially edentulous patients (10 males and 15 females, mean age $48.8{\pm19.7years$) who needed bone graft for installation of the implants due to alveolar bone deficiency. The patients took the radiographic exam, panoramic and periapical view at first visit, and had implant fixture installation surgery. All patients received immediate or delayed implant surgery with bone graft using U-shaped incision and tunneling technique. After an average of 2.8 months, the prosthesis was connected and functioned. The clinical prognosis was recorded by observation of the peri-implant tissue at every visit. A year after restoration, the crestal bone loss around the implant was measured by taking the follow-up radiographs. One patient took 3D-CT before bone graft, after bone graft, and 2 years after restoration to compare and analyze change of alveolar bone width. Results: This study included 25 patients and 39 implants. Thirty eight implants (97.4 %) survived. As for postoperative complications, five patients showed minor infection symptoms, like swelling and tenderness after bone graft. The other one had buccal fenestration, and secondary bone graft was done by the same technique. No complications related with bone graft were found except in these patients. The mean crestal bone loss around the implants was 0.03 mm 1 year after restoration, and this was an adequate clinical prognosis. A patient took 3D-CT after bone graft, and the width of alveolar bone increased 4.32 mm added to 4.6 mm of former alveolar bone width. Two years after bone graft, the width of alveolar bone was 8.13 mm, and this suggested that the resorption rate of bone graft material was 18.29 % during 2 years. Conclusions: The bone graft material retained within a pouch formed using U-shaped incision and tunneling technique resulted with a few complications, and the prognosis of the implants placed above the alveolar bone was adequate.

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.