• 제목/요약/키워드: Minimal Invasive Surgery

검색결과 137건 처리시간 0.029초

짧은 길이의 거친 표면 임프란트에 대한 후향적 연구 (RETROSPECTIVE STUDY OF SHORT ROUGH SURFACE IMPLANTS)

  • 공준하;이백수;김여갑;권용대;윤병욱;최병준
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권1호
    • /
    • pp.41-45
    • /
    • 2009
  • Background: Reduced bone height is one of the major problems faced in restoring tooth loss with implants. By the use of short implants, it is possible to reduce complicated and invasive treatment such as bone graft, allowing more simple surgery. But short implants are generally considered to have lower success rates than that of standard implants. Purpose: To assess the results of short Straumann implants by a retrospective study of short Straumann implants with TPS(titanium plasma-sprayed) and SLA(sandblasted, large grit, acid etched) surfaces. Materials and methods: 173 implants in 106 patients who received short Straumann implant surgery(${\le}8\;mm$) in the department of oral and maxillofacial surgery, Kyunghee Dental Hospital, from February 1996 to October 2006 were selected and studied. All of the implants were followed up after prosthetic rehabilitation. The average follow-up period was 34 months with 119 months as the longest follow up period. The average follow-up period after prosthetic rehabilitation was 31 months. 64 females(60.4%) and 42 males(39.6%) participated in the research with the age range of 19 to 85(mean age 47). 20 patients(18.9%) were under 40, 85 patients(80.2%) were over 40 and under 70, and only one patient(0.9%) was over 70 years old. Results: 27 implants(15.6%) had TPS surface while 146 implants(84.4%) had SLA surface. 9 implants(5.2%) were 3.3, 108 implans(62.4%) were 4.1mm and 56 implants(32.4%) were 4.8mm in diameter. 167 implants(96.5%) were 8mm and 6 implants(3.5%) were 6mm in length. There were 24 implants(13.9%) on the maxillas and 149 implants(68.8%) on the mandibles. 119 implants(68.8%) were rehabilitated with FPD(fixed partial denture), 47 implants(27.2%) with single crowns and 4 implants(2.3%) with overdentures. Among the fixed partial dentures, 30 of them were splinted with short implants only. After over an year of follow-up period, 139 implants(96.5%) out of 144 implants showed marginal bone loss of less than 1mm. 3 out of 173 implants failed showing 98.27% survival rate. Conclusions: The use of short Straumann implants(${\le}8mm$) can be a simple and reliable treatment method in minimal residual bone height.

A STUDY ON THE CHANGE OF IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS

  • Park Chan-Jin;Kim Yung-Soo;Kim Chang-Whe;Cho Lee-Ra;Yi Yang-Jin
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.271-287
    • /
    • 2003
  • Statement of problem: Resonance frequency analysis (RFA) has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized baseline data using RFA. Purpose: This study was performed to evaluate RFA value changes in two stage surgery group and one stage surgery group in patients. Material and method: Forty-seven mandibles in consecutively implant installed patients were selected for this study and 141 fixtures were installed. Ninety-three fixtures were double threaded, machined surface design ($Br{\aa}anemark^{(R)}$ MK III, Nobel Biocare AB, Goteborg, Sweden) and 48 fixtures were root form, threaded, HA-coated surface one ($Replace^{TM}$, Steri-Oss/Nobel Biocare AB, USA). Among those, each 10 fixture was installed in one stage group patients. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, at healing abutment connection and in the loading period for two stage surgery group patients and during at each 4, 6, 8, 10, 12week and in the loading phase for one stage surgery group patients and evaluated the changes according to the time and fixture type. Results: In two stage surgery group, mean and SO of ISQ values of machined surface implants were $76.85{\pm}3.74,\;75.76{\pm}5.04,\;75.73{\pm}4.41$ and those of HA-coated surface implant were $75.05{\pm}6.23,\;77.58{\pm}5.23,\;78.32{\pm}4.29$ during fixtures installation, at healing abutment connection and in the loading period, respectively. In one-stage surgery group, the ISQ values of machined surface and HA-coated surface implants decreased until 4 or 6 week and maintained at plateau for 1-3 week and increased to the loading period. Conclusions: Machined and HA-coated surface implants showed minimal ISQ changes with time if they were installed at the sites showing at least intact cortical plate and good bone qualities. And HA-coated implants had a tendency to show somewhat increased ISQ values with time.

슬관절 연골 결손에 대한 fibrin matrix 자가 연골 세포 이식술 후 이차 관절경 소견 - 예비보고 - (Second Look Arthroscopic Finding after Fibrin Matrix Autologous Chondrocyte Implantation for the Treatment of Articular Cartilage Defect of the Knee - Preliminary Report -)

  • 최성욱;오인석;김려섭;박선원;이종민;이문;김명구
    • 대한관절경학회지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2007
  • 목적: 슬관절 연골 결손 환자 치료로 진보적으로 변형된 gel 형태의 fibrin matrix 자가 연골 세포 이식술을 시행한 후 이차 관절경을 통하여 그 단기 결과를 알아보고자 하였다. 대상 및 방법: 슬관절 연골 결손 환자 6명을 대상으로 하였으며 결손 크기는 평균 $5.13\;cm^2$ 이었다. 1차 관절경 시술시 연골 전층을 채취하여 $4{\sim}6$주간 배양하여 연골 세포를 증식한 후, 2차로 fibrin을 matrix로 하는 gel 형태의 자가 연골 세포 이식술을 시행하였다. 결과: 수술 후 Modified Cincinnati Knee Score는 6명중 4예에서 양호 이상, Lysholm function score는 수술 전 평균 59.5점에서 수술 후 평균 75.25점으로 증상이 호전되었다. ICRS grade 측정에서 6명중 4예에서 거의 정상의 결과를 보였다. 결론: Gel 형태의 fibrin matrix 자가 연골 세포 이식술은 기존의 고식적인 방법에 비해 수술시간이 짧고, 최소 절개 또는 관절경적 시술이 가능한 유용한 방법으로 사료되나, 추후 더 많은 증례 및 지속적인 장기 추시가 필요할 것으로 생각된다.

  • PDF

다한증의 제한적 교감신경절단술 (Limited Sympathetic Nervelipping of T2 Sympathetic Chain Block for Essential Hyperhidrosis)

  • 박만실;서충헌;심재천;최봉춘;이영철
    • Journal of Chest Surgery
    • /
    • 제32권9호
    • /
    • pp.813-817
    • /
    • 1999
  • 배경: 국소적 다한증의 흉강경을 이용한 통상적인 흉부교감신경절제술이나 교감신경절차단술은 효과적인 치료법이기는 하나 수술 후 심한 보상성 다한증이 많이 발생 하고 수장부 다한증의 경우 수술 후 얼굴에서 땀이 나지 않는 부작용이 발생한다. 저자들은 기존의 수술법을 개량해 제한적 흉부교감신경절단술을 고안하였다. 본 연구는 제한적 교감신경절단술의 결과를 분석하였다. 대상 및 방법: 1998년 5월부터 8월 까지 17명의 환자들에게 제한적 흉부교감신경절단술을 시행하였다. 9명의 안면부 다한증인 환자들에게 두 번째 교감신경절 위 아래의 교감신경을 절단하던 기존의 방법과는 달리 첫번째 와 두 번째 흉부교감신경절 사이의 신경절간신경만을 절단하였다. 8명의 수장부 다한증 환자에 대해서는 두 번째와 세 번째 흉부 교감신경절간신경을 절단하였다. 결과: 17명의 환자들 중 16명의 환자에서 수술 후 원하던 부위의 땀이 나지 않았으나 1명의 환자는 수술 1달 후 얼굴의 땀이 재발하였다. 안면부 다한증으로 수술을 받았던 9명의 환자들 보상성 다한증으로 4명이 심하게, 4명이 중등도로, 1명은 경미하게 불편을 호소 하였다. 그러나 수장부 다한증으로 수술을 받았던 8명의 환자들 중에서는 보상성 다한증을 3명에서 중등도로, 1명이 경미하게 호소하였으며 4명은 보상성 다한증이 없었다. 결론: 제한적 흉부교감신경절단술은 최소 침투 수술법으로 효과적인 치료법이며 특히 수장부 다한증에서는 수술 후 체간에서 발생하는 보상성 다한증의 발생을 줄이고 얼굴의 무한증을 막을 수 있을 것으로 사료된다.

  • PDF

Diagnostic Value of Clinical T Staging Assessed by Endoscopy and Stomach Protocol Computed Tomography in Gastric Cancer: The Experience of a Low-Volume Institute

  • Kim, Tae Hyeon;Kim, Jeong Jae;Kim, Seung Hyoung;Kim, Bong Soo;Song, Hyun Joo;Na, Soo Young;Boo, Sun Jin;Kim, Heung Up;Maeng, Young Hee;Hyun, Chang Lim;Kim, Kwang Sig;Jeong, In Ho
    • Journal of Gastric Cancer
    • /
    • 제12권4호
    • /
    • pp.223-231
    • /
    • 2012
  • Purpose: Clinical staging of gastric cancer appears to be important more and more for tailored therapy. This study aimed to verify the accuracy of clinical T staging in a low-volume institute. Materials and Methods: We retrospectively reviewed prospectively collected data of gastric cancer patients who underwent resection. A total of 268 patients of gastric cancer were enrolled from March 2004 to June 2012. These demographics, tumor characteristics, and clinical stages were analyzed for identification of diagnostic value of clinical T staging. Results: The predictive values for pT1 of endoscopy and computed tomography were 90.0% and 89.4%, respectively. In detail, the predictive values of endoscopy for pT1a, pT1b, and pT2 or more were 87%, 58.5%, and 90.6%, respectively. The predictive values of computed tomography for pT1a, pT1b, and pT2 or more were 68.8%, 73.9%, and 84.4%, respectively. The factors leading to underestimation of pT2 or more lesions by gastroscopy were the middle third location, the size greater than 2 cm, and younger age. Those for overestimation of pT1 lesion by computed tomography were male, age more than 70 years, elevated type, and size greater than 3 cm. Conclusions: Diagnostic accuracy of early gastric cancer was 90%, which is comparable to those of high volume center. In patients with early gastric cancer, limited gastrectomy or minimal invasive surgery can be safely introduced at a low volume center also. However, the surgeon of low-volume institute should consider the accuracy of clinical staging before extending the indication of limited treatment.

안면다한증에서 경요도 절제용 전기절제 내시경을 이용한 교감신경간 소작술 (T2 Sympathicotomy with TUR Electroresectoscope for Facial Hyperhidrosis)

  • 최봉춘;이영철;이효근;김찬
    • The Korean Journal of Pain
    • /
    • 제11권2호
    • /
    • pp.220-225
    • /
    • 1998
  • Background: The patients of facial hyperhidrosis have been known that they had much difficulties in interpersonal relationships and social activities due to excessive hidrosis when they were in stress, hot weather, or having meals. Previous drug therapy and stellate ganglion block have only temporary effects. The surgical method, $T_1$ sympathetomy has the risk of Hornor's syndrome. For that reasons, the sympathicotomy of proximal and distal portions of $T_2$ sympathetic ganglion with electroresectoscope used in transurethral resection seemed to be appropriate procedure, and we would like to report the results of our procedure. Method: Under the general anesthesia with semi-sitting position, and the portal was made through the small incision along the upper border of the 4th rib at the crossing point of mid-axillary line. After the partial collapse of lung by insufflation of 300 to 500 ml of $CO_2$, $T_2$ sympathetic ganglion was identified and resected proximally and distally with electro-cauterization. Finally the lung was expanded by limiting flow until the airway pressure reached 30 to 40 cm$H_2O$, and the wound was closed after removal of electroresectoscope. Result: There was no postoperative complication requiring surgical interventions. The facial sweating was stopped immediately after the operation and all the patients appeared to be satisfied. Conclusion: $T_2$ sympathicotomy with TUR electroresectoscope is thought be the minimal invasive and highly successful method in the treatment of facial hyperhidrosis. But longer terms follow-up will be needed to prove this result.

  • PDF

초음파 수술기의 수술 효율성 향상을 위한 진동자 임피던스 측정에 따른 조직 분류 연구 (Classification of Organs Using Impedance of Ultrasonic Surgical Knife to improve Surgical Efficiency)

  • 김홍래;김성천;김광기;김영우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.141-147
    • /
    • 2013
  • Ultrasonic shears is currently in wide use as an energy device for minimal invasive surgery. There is an advantage of minimizing the carbonization behavior of the tissue due to the vibrational energy transfer system of the transducer by applying a piezoelectric ceramic. However, the vibrational energy transfer system has a pitfall in energy consumption. When the movement of the forceps is interrupted by the tissue, the horn which transfers the vibrational energy of the transducer will be affected. A study was performed to recognize different tissues by measuring the impedance of the transducer of the ultrasonic shears in order to find the factor of energy consumption according to the tissue. In the first stage of the study, the voltage and current of the transducer connecting portion were measured, along with the phase changes. Subsequently, in the second stage, the impedance of the transducer was directly measured. In the final stage, using the handpiece, we grasped the tissue and observed the impedance differences appeared in the transducer To verify the proposed tissue distinguishing method, we used the handpiece to apply a force between 5N and 10N to pork while increasing the value of the impedance of the transducer from 400 ${\Omega}$.. It was found that fat and skin tissue, tendon, liver and protein all have different impedance values of 420 ${\Omega}$, 490 ${\Omega}$, 530 ${\Omega}$, and 580 ${\Omega}$, respectively. Thus, the impedance value can be used to distinguish the type of tissues grasped by the forceps. In the future study, this relationship will be used to improve the energy efficiency of ultrasonic shears.

Accuracy of Fine Needle Aspiration Cytology of Salivary Gland Lesions: Routine Diagnostic Experience in Bangkok, Thailand

  • Sudarat, Nguansangiam;Somnuek, Jesdapatarakul;Nisarat, Dhanarak;Krittika, Sosrisakorn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권4호
    • /
    • pp.1583-1588
    • /
    • 2012
  • Fine needle aspiration (FNA) cytology is well accepted as a safe, reliable, minimal invasive and cost-effective method for diagnosis of salivary gland lesions. This study evaluated the accuracy and diagnostic performance of FNA cytology in Thailand. A consecutive series of 290 samples from 246 patients during January 2001-December 2009 were evaluated from the archive of the Anatomical Pathology Department of our institution and 133 specimens were verified by histopathologic diagnoses, obtained with material from surgical excision or biopsy. Cytologic diagnoses classified as unsatisfactory, benign, suspicious for malignancy and malignant were compared with the histopathological findings. Among the 133 satisfactory specimens, the anatomic sites were 70 (52.6%) parotid glands and 63 (47.4 %) submandibular glands. FNA cytological diagnoses showed benign lesions in 119 cases (89.5 %), suspicious for malignancy in 3 cases (2.2 %) and malignant in 11 cases (8.3%). From the subsequent histopathologic diagnoses, 3/133 cases of benign cytology turned out to be malignant lesions, the false negative rate being 2.2 % and 1/133 case of malignant cytology turned out to be a benign lesion, giving a false positive rate was 0.8%. The overall accuracy, sensitivity, specificity, positive predictive value and negative predictive value were 97.0% (95% CI, 70.6%-99.4%), 81.3% (95% CI, 54.4%-96.0%), 99.1% (95% CI, 95.4%-100%), 92.9% (95% CI, 66.1%-99.8), 97.5% (95% CI, 92.8%-99.5%), respectively. This study indicated that FNA cytology of salivary gland is a reliable and highly accurate diagnostic method for diagnosis of salivary gland lesions. It not only provides preoperative diagnosis for therapeutic management but also can prevent unnecessary surgery.

전(全)복강경하 위절제술의 임상적 유용성 (Clinical Usefulness of a Totally Laparoscopic Gastrectomy)

  • 김진조;김성근;전경화;강한철;송교영;진형민;김욱;전해명;박조현;박승만;임근우;박우배;김승남
    • Journal of Gastric Cancer
    • /
    • 제7권3호
    • /
    • pp.132-138
    • /
    • 2007
  • 목적: 최근 우리나라에서는 복강경보조하 위절제술이 활발히 시행되고 있으나 전복강경하 위절제술은 복강 내 위장관 문합의 어려움 때문에 별로 시행되고 있지 않다. 이에 저자들은 복강경용 선형 문합기를 이용한 다양한 복강내 문합술을 통한 전복강경하 위절제술의 경험을 통하여 그 유용성을 알아보고자 하였다. 대상 및 방법: 2004년 6월부터 2007년 5월까지 000대학교 0000병원 외과에서 위암 또는 위양성종양으로 전복강경하 위절제술을 시행 받은 환자 81명을 대상으로 하였으며 위절제술 후 복강 내 문합에는 복강경용 선형 문합기 만을 사용하였다. 대상 환자에 대한 수술의 결과와 임상병리학적인 결과를 후향적으로 조사하였다. 결과: 수술 시간은 평균 287분이었고, 문합에 소요된 시간은 평균 40분이었으며 사용한 선형 문합기의 카트리지 수는 평균 7.5개였다. 수술 후 첫 가스 배출은 2.9일, 첫 유동식 섭취는 3.6일, 재원 기간은 10.3일이었다. 수술과 관련된 합병증은 11예(13.6%)에서 발생하였으나 수술로 인한 사망예나 개복수술로의 전환 예는 없었다. 75명의 위암 환자에서 절제된 림프절은 평균 38.1개였으며 병기는 I기가 72명, II기가 2명 그리고 IV기가 1명이었다. 위암 환자들의 평균 추적기간 16개월 동안에 5명의 환자가 사망하였으나 위암의 재발에 의한 사망은 없었다. 결론: 전복강경하 위절제술은 안전하고 기술적으로 용이 하였으며 위절제술이 필요한 환자들에 대한 좋은 최소침습수술 중의 하나라고 생각한다.

  • PDF

경골과 골절의 수술적 치료 결과 (Operative Treatment of Tibial Plateau Fractures)

  • 신덕섭;성병년;김동원
    • Journal of Yeungnam Medical Science
    • /
    • 제18권2호
    • /
    • pp.187-198
    • /
    • 2001
  • 저자들은 1991년 1월부터 1997년 12월까지 7년간, 수술적으로 치료한 경골과 골절 환자 중 최단 1년에서 최장 8년까지 장시 추시 관찰이 가능했던 29예를 대상으로 치료 예후에 관여하는 인자를 조사하여 다음과 같은 결과를 얻었다. 1. 20대부터 40대까지가 15명(51.7%)을 차지해 활동기 연령층에서 발생 빈도가 높았고, Schatzker의 분류에 의해 2형 골절이 11예(37.9%)로 가장 많았다. 동반 연부 조직 손상은 18예(62.1%)에서 발생되었으며, 외측 반월상 연골 손상이 6예(33.3%), 내측 측부 인대손상이 4예(22.2%)로 많았다. Blokker 평가 기준에 의해 29예 중 23예(79.3%)가 양호하였다. 2. 불량한 결과와 관련 있는 요인으로는 30대 이전의 연령층, 고 에너지 손상의 Schatzker 분류 IV형 이상의 골절, 전방 십자 인대 손상과 반월상 연골 손상 등의 동반 손상이었다. 또한 각 골절의 양상과 손상의 정도에 따라 골절면의 정확한 해부학적 정복과 견고한 내고정을 시행하여, 조기에 슬관절 운동을 시행하여야 슬관절의 기능을 향상시킬 수 있을 것으로 사료되었다.

  • PDF