• Title/Summary/Keyword: Minimal Cut-Set

Search Result 42, Processing Time 0.026 seconds

A Systems Approach to Press Injuries Using Fault Tree Analysis (Fault Tree Analysis에 의한 Press 안전사고의 체계적 분석)

  • Lee, Myeon-U;Yun, Jo-Deok
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.6 no.2
    • /
    • pp.1-11
    • /
    • 1980
  • The purpose of this study is to attempt a systems approach to press injuries using Fault Tree Analysis. Three major techniques were used: Industrial Accident Dynamics (IAD) by which accident analysis can be made, Fault Tree Analysis (FTA) by which quantification of accident analysis can be made, Computerized Algorithm by which minimal cut set to accident can be identified. A survey has been made of ninety two cases of press injuries from seven industrial firms. All cases of the accident are analyzed using the three techniques. According to the analysis, lack of safety knowledge and improper scaffold seem to be the primal cause of accident. Comparisons of the accident causes to actual accident reports (National Institute of Labor Science) demonstrates that the FTA is a powerful tool for industrial accident prevention. On the basis of this result, some countermeasures are discussed.

  • PDF

A Analysis of a Pointed-end Equipment Arm Safety-Accident for Fault Tree Analysis (Fault Tree Analysis에 의한 첨단설비 Arm 안전사고의 분석)

  • Yun Yong-Gu;Park Beom
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2005.05a
    • /
    • pp.279-290
    • /
    • 2005
  • The purpose of this study is to attempt a Analysis of a pointed-end Equipment Arm Safety-Accident for Fault Tree Analysis. Three major techniques were used first problem is Z-Model by which accident Analysis & prevention of a pointed-end Industry can be made, Fault Tree Analysis(FTA) bywhich quantification of a pointed-end Equipment accident Analysis can be made it 5 years in past and the third, manual-written by which minimal cut set to accident can be Identified. A example has been made of issue point a pointed-end Equipment that the Arm in loader happen to Injuries. According to the Analysis lack of safety knowledge, unsafety-behavior seem to be the primal cause of accident. Comparision of the accident cause to actual report demonstratesthat the FTA a efficient tool for Industrial Accident prevention.

  • PDF

A Study on the Availability Prediction of Start-up Power Supply in Nuclear Power Plant by FTAMethod (FTA기법에 의한 원전기동전원의 이용율 예측에 관한 연구)

  • Che, Gyu-Shik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.517-523
    • /
    • 1999
  • The Start-up transformers or on-site stand-by transformers are installed for the start-up and shut-down of generator and emergency status in unclear power plant. The on-site power supply configuration using these transformers must be detemined by considering configuration requirements, site characteristics, reliability and availability severely because it is remarkably important for safety and benefit of plant. The start-up or stand-by power supply configuration has been determined considering only safety requirements and construction cost up to now in Korea. I study various reliability estimating methods for the prediction of availability, and estimate the unavailability for the start-up power supply system of two 1,000㎿ unclear power plants. I also detemine the reliability and unavailability and unavailavility of equipment, system and configuration using FTA method.

  • PDF

Risk Assessment and Application in Chemical Plants Using Fault Tree Analysis (FTA를 이용한 화학공장의 위험성 평가 및 응용)

  • Kim Yun-Hwa;Kim Ky-Soo;Yoon Sung-Ryul;Um Sung-In;Ko Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.81-86
    • /
    • 1997
  • This study is to estimate the possibility of accident in chemical plants from the analysis of system component which affects the occurrence of top event. Among the various risk assessment techniques, the Fault Tree Analysis which approaches deductively on the route of accident development was used in this study. By gate-by-gate method and minimal cut set, the qualitative and quantitative risk assessment for hazards in plants was performed. The probability of occurrence and frequency of top event was calculated from failure or reliability data of system components at stage of the quantitative risk assessment. In conclusion, the probability of accident was estimated according to logic pattern based on the Fault Tree Analysis. And the failure path which mostly influences on the occurrence of top event was found from Importance Analysis.

  • PDF

A Study on the Reliability Analysis and Risk Assessment of Liquefied Natural Gas Supply Utilities (천연가스 공급설비에 대한 기기신뢰도 분석 및 위험성 평가)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.8-20
    • /
    • 2003
  • Natural gas has been supplied through underground pipelines and valve stations as a new city gas in Seoul. In contrast to its handiness the natural gas has very substantial hazards due to fires and explosions occurring from careless treatments or malfunctions of the transporting system. The main objectives of this study are to identify major hazards and to perform risk assessments after assessing reliabilities of the composing units in dealing with typical pipeline networks. there-fore two method, fault tree analysis ;1nd event tree analysis, are used here. Random valve stations are selected and considered its situation in location. The value of small leakage, large rupture, and no supply of liquefied natural gas is estimated as that of top event. By this calculation the values of small leakage are 3.29 in I)C valve station, 1.41 in DS valve station, those of large rup-lure are $1.90Times10_{-2}$ in DC valve station, $2.32$\times$10^{-2}$ in DS valve station, and those of no supply of LNG to civil gas company are $2.33$\times$10 ^{-2}$ , $2.89$\times$10^{-2}$ in each valve station. And through minimal cut set we can find the parts that is important and should be more important in overall system. In DC valve station one line must be added between basic event 26,27 because the potential hazard of these parts is the highest value. If it is added the failure rate of no supply of LNG is reduced to one fourth. In DS valve station the failure rate of basic event 4 is 92eye of no supply of LNG. Therefore if the portion of this part is reduced (one line added) the total failure rate can be decreased to one tenth. This analytical study on the risk assessment is very useful to prepare emergency actions or procedures in case of gas accidents around underground pipeline networks and to establish a resolute gas safety management system for loss prevention in Seoul metropolitan area.

A Study on the Standard Setting for the Basic Skills Competency Test: Focusing on 3rd Grade Basic Mathematics (기초학력 진단평가의 성취수준 설정에 관한 연구: 초등학교 3학년 '기초수학' 사례를 중심으로)

  • Kim, HeeKyoung;Cho, Seongmin
    • Journal of the Korean School Mathematics Society
    • /
    • v.16 no.3
    • /
    • pp.479-498
    • /
    • 2013
  • As education is one of key factors to improve national competitiveness, quality education becomes a top priority in all countries around the world. In South Korea, The Basic Skills Competency Test is administered annually to select below-basic third graders and provide intervention programs. The Basic Skills Competency Test was designed to diagnose the minimal competency of third graders according to a national-level standards. The purpose of this study was to analyze standard-setting procedures and set cut-off scores. This study offered the empirical evidence that standard-setting is generally applicable in schools by the modified Ebel method. More future researches addressing appropriate and efficient standard-setting methods in real school situations are needed to be taken in.

  • PDF

A Reliability Analysis in LVDC Distribution System Considering Power Quality (전력품질을 고려한 LVDC 배전계통의 신뢰도 분석)

  • Noh, Chul-Ho;Kim, Chung-Mo;Kim, Doo-Ung;Gwon, Gi-Hyeon;Oh, Yun-Sik;Han, Jun;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.54-61
    • /
    • 2015
  • Recently, DC-based power system is being paid attention as the solution for energy efficiency. As the example, HVDC (High Voltage DC) transmission system is utilized in the real power system. On the other hand, researches on LVDC (Low Voltage DC) distribution system, which are including digital loads, are not enough. In this paper, reliability in LVDC distribution system is analyzed according to the specific characteristics such as the arrangement of DC/DC converters and the number of poles. Furthermore, power quality is also taken account of since LVDC distribution system includes multiple sensitive loads and electric power converters. In order to achieve this, LVDC distribution systems are modeled using ElectroMagnetic Transient Program (EMTP) and both the minimal cut-set method and Customer Interruption Cost (CIC) are used in the reliability analysis.

Vital Area Identification of Nuclear Facilities by using PSA (PSA기법을 이용한 원자력시설의 핵심구역 파악)

  • Lee, Yoon-Hwan;Jung, Woo-Sik;Hwang, Mee-Jeong;Yang, Joon-Eon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • The urgent VAI method development is required since "The Act of Physical Protection and Radiological Emergency that is established in 2003" requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The VAI methodology is developed to (1) make a sabotage model by reusing existing fire/flooding/pipe break PSA models, (2) calculate MCSs and TEPSs, (3) select the most cost-effective TEPS among many TEPSs, (4) determine the compartments in a selected TEPS as vital areas, and (5) provide protection measures to the vital areas. The developed VAI methodology contains four steps, (1) collecting the internal level 1 PSA model and information, (2) developing the fire/flood/pipe rupture model based on level 1 PSA model, (3) integrating the fire/flood/pipe rupture model into the sabotage model by JSTAR, and (4) calculating MCSs and TEPS. The VAT process is performed through the VIPEX that was developed in KAERI. This methodology serves as a guide to develop a sabotage model by using existing internal and external PSA models. When this methodology is used to identify the vital areas, it provides the most cost-effective method to save the VAI and physical protection costs.

FMEA and FTA for Reliability Analysis of Hybrid Rocket Motor (하이브리드 로켓 모터의 신뢰성 분석을 위한 FMEA 및 FTA)

  • Moon, Keun Hwan;Kim, Dong Seong;Choi, Joo Ho;Kim, Jin Kon
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.4
    • /
    • pp.27-33
    • /
    • 2013
  • In this study, the FMEA and FTA for reliability analysis of hybrid rocket motor are performed, that was designed in the Hybrid Rocket Propulsion Laboratory of Korea Aerospace University. In order to carry out these analyses the structure of the hybrid rocket motor is hierarchically divided into 36 parts down to the component level and FMEA is carried out with 72 failure modes. Reliability is assessed based on the FMEA, and the results are used in the FTA to evaluate the overall system reliability. In the FMEA, the relationship between the cause and failure modes, effects and their risk priorities are evaluated qualitatively. 27 failure modes are chosen as those with the critical severity that should be improved with priority. As a result of the FMEA / FTA study, a series of design or material changes are made for the improvement of reliability.

Feasibility Study on the Fault Tree Analysis Approach for the Management of the Faults in Running PCR Analysis (PCR 과정의 오류 관리를 위한 Fault Tree Analysis 적용에 관한 시범적 연구)

  • Lim, Ji-Su;Park, Ae-Ri;Lee, Seung-Ju;Hong, Kwang-Won
    • Applied Biological Chemistry
    • /
    • v.50 no.4
    • /
    • pp.245-252
    • /
    • 2007
  • FTA (fault tree analysis), an analytical method for system failure management, was employed in the management of faults in running PCR analysis. PCR is executed through several processes, in which the process of PCR machine operation was selected for the analysis by FTA. The reason for choosing the simplest process in the PCR analysis was to adopt it as a first trial to test a feasibility of the FTA approach. First, fault events-top event, intermediate event, basic events-were identified by survey on expert knowledge of PCR. Then those events were correlated deductively to build a fault tree in hierarchical structure. The fault tree was evaluated qualitatively and quantitatively, yielding minimal cut sets, structural importance, common cause vulnerability, simulation of probability of occurrence of top event, cut set importance, item importance and sensitivity. The top event was 'errors in the step of PCR machine operation in running PCR analysis'. The major intermediate events were 'failures in instrument' and 'errors in actions in experiment'. The basic events were four events, one event and one event based on human errors, instrument failure and energy source failure, respectively. Those events were combined with Boolean logic gates-AND or OR, constructing a fault tree. In the qualitative evaluation of the tree, the basic events-'errors in preparing the reaction mixture', 'errors in setting temperature and time of PCR machine', 'failure of electrical power during running PCR machine', 'errors in selecting adequate PCR machine'-proved the most critical in the occurrence of the fault of the top event. In the quantitative evaluation, the list of the critical events were not the same as that from the qualitative evaluation. It was because the probability value of PCR machine failure, not on the list above though, increased with used time, and the probability of the events of electricity failure and defective of PCR machine were given zero due to rare likelihood of the events in general. It was concluded that this feasibility study is worth being a means to introduce the novel technique, FTA, to the management of faults in running PCR analysis.