• Title/Summary/Keyword: Miniature

Search Result 814, Processing Time 0.026 seconds

The Development of Ultra-Miniature / Wideband VCO (초소형/광대역 VCO 개발)

  • 변상기;강용철;황치전;안태준
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.183-186
    • /
    • 1999
  • The Ultra-miniature and low phase noise Colpitts VCO of 0.06㏄ in size has been developed using the high Q resonator and phase compensation technique. This type is one transistor VCO without a buffer. To design and simulate the VCO accurately, nolinear model parameters of a bipolar transistor are extracted using the measured I-V data and S parameters based on the Gummel-Poon model. Design and simulation have been done by Serenade 7.5 design tool using the extracted nonlinear model parameters. The wideband VCO has been designed using two varactor diodes and open loop gain compensation technique to improve the operating frequency range. The ultra-miniature VCO has shown the phase noise of -91㏈c/Hz at 10KHz offset and output power of -3㏈m The wideband VCO has shown the tuning frequency bandwidth of 150MHz phase noise of -95㏈c/Hz at 10KHz offset and output power of 5㏈m.

  • PDF

A novel miniature condenser microphone with a hinge diaphragm (힌지구조를 갖는 초소형 콘덴서 마이크로폰)

  • Kim, Hye-Jin;Lee, Sung-Q;Park, Kang-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.174-178
    • /
    • 2007
  • This paper presents a novel, highly sensitive condenser microphone with a flexure hinge diaphragm. We used the finite-element analysis (FEA) to evaluate the mechanical and acoustic performance of the condenser microphone with a hinge diaphragm. And we fabricated the miniature condenser microphones with area of 1.5 mm${\times}$1.5 mm. From the simulation results, we confirmed that the maximum displacements at the center of flexure hinge diaphragms are several hundred times, compared with flat diaphragms. The sensitivities of fabricated miniature microphones are about $12.87{\mu}V/Pa$ at 1 kHz under a low bias voltage of 1 V, and the frequency response is flat upto 13 kHz.

The Experimental Study of Miniature Heat Pipes for Cooling Microprocessor Chips (전자칩 냉각을 위한 소형 히트 파이프에 대한 실험적 연구)

  • Lee, S.M.;Kim, H.B.;Yang, J.S.;Lee, K.B.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.353-358
    • /
    • 2000
  • This paper presents the experimental investigation about miniature heat pipe for notebook PC. The focus of analysis is the operating temperature not to exceed $65^{\circ}C$ maximum allowable CPU surface temperature. Copper is used to heat pipe material and brass is wick material, and working fluid is selected to water. This cooling system is heat spreader method using a aluminum plate, since this method is most commonly used. According to the present study, heat for 3mm heat pipe, 8W, and for 4mm heat pipe, 10W, is found to power dissipation limit respectively, Soon after this investigation, sufficient long term life test should be followed.

  • PDF

An Experimental Study on the Flow Motion of the Working Fluid in Miniature Thermosyphons (미세 서모사이폰 내의 작동유체의 유동에 대한 실험적 연구)

  • Oh, K.Y.;Kim, K.N.;Jang, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.341-346
    • /
    • 2000
  • This experimental study investigated the flow motion of the working fluid for various diameters of miniature thermosyphons and the performance characteristics for the various amount of the working fluid. The temperatures of condenser surface were measured and visual observations were conducted. The test results show that some fluid condensed in the tube diameters of 0.18cm and 0.22cm is not returned to the evaporator section due to capillary effect so that large temperature gradients are measured. To enhance returning the working fluid, one copper wire of 0.5mm diameter was inserted and the test results show good performance. When the liquid charge was less than 10% in volume dry-out was occurred fur the thermosyphons of the inner diameter of 1.8mm and 2.2mm.

  • PDF

Construction Technique of Miniature Rumen for the Absorption Test in the Ruminants (반추수(反芻獸)의 흡수시험(吸收試驗)을 위한 소형위(小型胃)의 조성술(造成術))

  • Kim, Kyo-joon
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.105-109
    • /
    • 1984
  • Five Korean native goats were employed to test the effectiveness of the two modified techniques (Method I and II) of Pawlow's pouch method, Both methods turned out to be successful and simpler than the original pawlow's pouch method. In both methods, the miniature rumens were formed on the junction of two veins; versa ruminalis sinistra and vena ruminalis dextra. Both method I and II have the advantage of shortening the operation time, but caution is necessary to prevent the fistula formation between the rumen and miniature rumen in Method I.

  • PDF

Effect of a Thin Wire Insert on the Bubble Rise in a Miniature Tow-Phase Closed Thermosyphon (소형 밀폐형 이상 열싸이펀에서 삽입 세선이 기포상승에 미치는 영향)

  • 김원태;이윤표
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.99-109
    • /
    • 1996
  • Experimental investigations are carried out for the characteristics of bubble rise in the Miniature Two-Phase closed Thermosyphon(MTPCT) with a thin wire insert. The working fluids applied as experimental media are of three kinds: water, methanol, and ethanol. The effects of combination of the inclination with diametric ratio $\alpha$(=d$_{0}$/D$_{I}$) on rising velocity of a large bubble in the thermosyphon are explicitly analyzed. The realm of a movable bubble and the critical value of $\alpha$ are iteratively pursued to interpret the region Figures-of-Break, rooted in the governing physics relations, according to the application of working fluid. Experimental results are compared with those of analysis and critical ranges for $\alpha$ and D$_{I}$ were ascertained from comparisons.isons.

  • PDF

A Study on the Development of Dual-band PLL Frequency Synthesizer for miniature Repeater (초소형 중계기용 듀얼 밴드 주파수합성기 개발에 관한 연구)

  • 나영수;김진섭;강용철;변상기;나극환
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.37-40
    • /
    • 2003
  • The 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer has been developed for applications to the miniature repeater. The miniature dual-band repeater will be used at shopping mall, basements and underground parking lots. The in-loop 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer has been developed by designing Si BJT VCO and PLL loop circuits with Colpitts. The prototype of 1.63㎓, 2.33㎓ dual-band PLL frequency synthesizer of size 19${\times}$19${\times}$8(mm) has shown operating frequencies of 1.63㎓, 2.33㎓ ranges, RF output of 1dBm(PCS), 1dBm(IMT-2000), phase noise of -100 dBc/Hz(PCS), -95dBc/Hz(IMT-2000) at 10KHz offset, harmonics suppression of -24dB c(PCS), -15dBc(IMT-2000).

  • PDF

A Review on Cooling Technologies for Micro and Miniature Devices and Systems

  • Yoon, Jae-Sung;Choi, Jong-Won;Kim, Min-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.2
    • /
    • pp.70-77
    • /
    • 2007
  • As electric and mechanical devices have been miniaturized and highly integrated, heat generation per unit volume has been greatly increased. Therefore, effective cooling methods for micro and miniature systems have emerged as critical issues nowadays and a lot of studies have been carried out to find an optimum cooling strategy. This paper reviews recent researches on the cooling technologies which are mainly based on micro-fabrication processes. Design, development, experiments and numerical analysis of various cooling devices are discussed and their characteristics, problems and advantages are compared.

Radiography and ct features of atherosclerosis in two miniature schnauzer dogs

  • Lee, Eunji;Kim, Hyun Woo;Bae, Hyeona;Yu, DoHyeon;Choi, Jihye
    • Journal of Veterinary Science
    • /
    • v.21 no.6
    • /
    • pp.89.1-89.6
    • /
    • 2020
  • Two miniature Schnauzer dogs with chronic pancreatitis were investigated. Both dogs showed systemic hypertension and increased concentrations of triglycerides and C-reactive protein. Abdominal radiography revealed cylindrical calcification in the retroperitoneum, and computed tomography (CT) showed extensive calcification of the abdominal and peripheral arteries in both dogs. Metastases and other dystrophic conditions that can cause arterial calcification were excluded based on the laboratory tests, and the dogs were diagnosed with atherosclerosis ante mortem. Atherosclerosis should be considered when extensive arterial calcification is observed on abdominal radiography or CT in miniature Schnauzers.

Miniature J-T cryocooler using argon and nitrous oxide mixture

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.38-42
    • /
    • 2008
  • Miniature J-T cryocooler using nitrogen or argon has been widely adopted in cooling infrared sensor for space/military application and cryosurgery. Argon or nitrogen, however, has relatively low specific cooling power compared to nitrous oxide, but the ultimate operating temperature is much lower than nitrous oxide. On the other hand, nitrous oxide has large specific cooling power, but the operating temperature is limited to its boiling point (>183K). To compromise the different characteristics of these gases, the performance of miniature J-T cryocooler using argon and nitrous oxide mixture is investigated in this paper. Three different compositions of mixture (25/75, 50/50, and 75/25 molar fraction) are blended and tested. The results are compared with the experiments of pure argon and pure nitrous oxide. The experimental results show some encouraging potentiality of mixed refrigerant J-T cryocooler. The critical clogging problem, however, was observed with argon and nitrous oxide mixture, and the lowest achievable temperature with this mixture was limited to the freezing point of nitrous oxide. The paper discusses detailed clogging process of the mixture and suggests an alternative.