• Title/Summary/Keyword: Midline

Search Result 567, Processing Time 0.019 seconds

Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences

  • Choi, Won-joon;Lee, Su-jung;Moon, Cheol-Hyun
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.20-28
    • /
    • 2022
  • Objective: Although, digital models have recently been used in orthodontic clinics, physical models are still needed for a multitude of reasons. The purpose of this study was to assess whether the printed models can replace the plaster models by evaluating their accuracy in reproducing intermaxillary relationships and by appraising the clinicians' ability to measure the printed models. Methods: Twenty sets of patients' plaster models with well-established occlusal relationships were selected. Models were scanned using an intraoral scanner (Trios 3, 3Shape Dental System) by a single operator. Printed models were made with ZMD-1000B light-curing resin using the stereolithography method 3-dimensional printer. Validity, reliability, and reproducibility were evaluated using measurements obtained by three operators. Results: In evaluation of validity, all items showed no significant differences between measurements taken from plaster and printed models. In evaluation for reliability, significant differences were found in the distance between the gingival zeniths of #23-#33 (DZL_3) for the plaster models and at #17-#43 (DZCM_1) for the printed models. In evaluation for reproducibility, the plaster models showed significant differences between operators at midline, and printed models showed significant differences at 7 measurements including #17-#47 (DZR_7). Conclusions: The validity and reliability of intermaxillary relationships as determined by the printed model were clinically acceptable, but the evaluation of reproducibility revealed significant inter-operator differences. To use printed models as substitutes for plaster models, additional studies on their accuracies in measuring intermaxillary relationship are required.

Skeletal stability after 2-jaw surgery via surgery-first approach in facial asymmetry patients using CBCT

  • Hwang, Dae Seok;Seo, Jeong Seok;Choi, Hong Seok
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.11.1-11.8
    • /
    • 2020
  • Background: The purpose of this study is to compare the skeletal stability of two-jaw surgery via surgery-first approach with conventional two-jaw surgery in facial asymmetry patients by measuring the skeletal changes after surgery from a three-dimensional analysis. From January 2010 to January 2014, 40 patients with facial asymmetry who underwent two-jaw surgery in Pusan National University Hospital were included in this study. They were classified into experimental group (n = 20) who underwent two-jaw surgery via surgery-first approach and control group (n = 20) who underwent conventional two-jaw surgery. After selection of 24 landmarks and the construction of horizontal and sagittal, coronal reference planes, changes in 10 linear measurements and 2 angular measurements were compared between the surgery-first approach and conventional groups in the preoperative, immediate postoperative, and postoperative periods. The paired t test and Student t test were used for statistical analysis. The mean and standard deviation of the measurement were calculated for the experimental and control groups. Results: The statistical analysis showed that changes in skeletal measurements were similar between the surgery-first approach and conventional groups, according to each period. However, U1-SRP measurement showed statistically significant changes in surgery-first approach groups at postsurgical change (T1 to T2). Also, the mean treatment duration in the treatment group was 15.9 ± 5.48 months whereas that in the control group was 32.9 ± 14.05 months. Conclusion: In facial asymmetry patients, similar results were observed in the postoperative skeletal stability when 2-jaw surgery via surgery-first approach was compared with conventional 2-jaw surgery. However, significant lateral deviation of upper incisor midline was observed. In addition, a shorter average treatment duration was observed. To stabilize the unstable occlusion after surgery, increased wearing of the stent and proactive rubber guidance will be needed.

Clinical Management and Micro-Computed Tomography Analysis of Supernumerary Teeth in Infancy: A Case Report (영유아기 과잉치의 임상적 처치 및 micro-computed tomography 분석: 증례 보고)

  • Chaehyun, Na;Hana, Lee;Hansung, Kim;Jihun, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.348-356
    • /
    • 2022
  • Supernumerary teeth develop from excessive proliferation and development of the dental lamina. Supernumerary teeth can cause several problems, including ectopic eruption, delayed eruption, root resorption of adjacent teeth, and diastema. Supernumerary teeth in infancy are rare and have rarely been reported. Case of a 2-day-old infant with 3 supernumerary teeth is presented here and the patient was followed up for 21 months. The erupted supernumerary tooth in the primary dentition was extracted under moderate sedation at the age of 14 months. Microcomputed tomography analysis of the extracted tooth confirmed microscopic root malformation. After extraction, the midline diastema was reduced and oral hygiene improved. Early diagnosis and prompt treatment can prevent complications of supernumerary teeth.

The Protective Effects of Acupressure at Feng Shi against Chronic Alcohol-induced Muscle Atrophy in Rats (흰쥐의 풍시(風市)혈(GB31) 자극이 알콜성 근위축에 미치는 효과)

  • Bum-Hoi Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.1
    • /
    • pp.63-70
    • /
    • 2023
  • Purpose : Excessive alcohol causes damage to skeletal muscles, leading to the development of a specific disease entity called alcoholic myopathy. Chronic inflammation is related as an underlying mechanism for the loss of muscle mass induced by alcohol. Pro-inflammatory cytokines such as TNF-α (tumor necrosis factor-α) and IL-6 (interleukin-6) play a role in this process. The acupuncture point Feng Shi (GB 31) is located on the midline of the lateral aspect of the thigh, above the transverse popliteal crease. This acupoint is used for the treatment of weakness, atrophy, numbness, and post-stroke symptoms of lower limbs. The purpose of this study was to investigate the effect of Feng Shi stimulation on muscle atrophy caused by chronic alcohol administration. Method : Young male Sprague-Dawley rats were randomly divided into three groups of eight each: Normal, Control, and GB31. The rats in the Control and GB31 groups were orally given 25 % ethanol (5 ㎖/kg, body weight) daily for 4 weeks. The Normal group was similarly administered saline. The acupressure at Feng Shi was treated to rats in the GB31 group. After 4 weeks, the body weight, muscle weight and cross-sectional area of gastrocnemius were assessed and the histological changes in gastrocnemius muscle fiber were observed by hematoxylin and eosin staining. Moreover, TNF-α and IL-6 expressions were immunohistochemistrically evaluated. Results : Acupressure stimulation at Feng Shi had a protective effect on the weight reduction of the gastrocnemius muscle caused by alcohol intake, and had an effect of suppressing anatomical change in muscle fiber and decreasing the average cross-sectional area. Also, the immunoreactivities of TNF-α and IL-6 in the GB31 group were decreased. Conclusion : These results suggest that acupressure at Feng Shi has protective effects on chronic alcohol-induced muscle atrophy by inhibiting pre-inflammatory proteins such as TNF-α and IL-6.

Sutureless Laparoscopic Ovariectomy in Small Dogs Using Two 3-mm Portal Sites

  • Hyeon-Han Ku;Ho Hyun Kwak;Jun-Hyung Kim;Kyung-Mee Park;Heung Myong Woo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.319-325
    • /
    • 2022
  • Two-port laparoscopic ovariectomy (Lap-OVE) has been performed in small dogs, using 3-mm and 5-mm portal sites, and is associated with reduced surgical stress and postoperative pain. However, extension of the incision is often needed to extract the ovaries. In this study, we aimed to minimize invasiveness by using smaller-sized cannulas as well as a novel technique for ovary extraction. Lap-OVE was performed on six, healthy female dogs (range, 3 to 7.2 kg) using two 3-mm midline portals. The middle finger of a size M nitrile glove was cut at its base and sterilized preoperatively. The ovary was suspended at the body wall using a 1-0 blue nylon needle, and the ovarian pedicle and ligaments were transected using a 3-mm bipolar forceps. To facilitate the glove passing through the 3.9-mm port, it was turned inside out to expose the smooth inner surface, before being inserted into the abdominal cavity with an applicator. Both ovaries were placed inside, and the mouth of the glove was exteriorized through the port with a laparoscopic grasping forceps. The ovaries were morcellated inside the glove, using Adison-Brown tissue forceps and iris scissors, which enabled safe extraction without incision enlargement. Median incision lengths were 4.3 mm (3.5-mm cranial cannula) and 4.8 mm (3.9-mm caudal cannula). An advantage of this procedure was that there was no need for skin sutures. In conclusion, using our novel technique, sutureless Lap-OVE was possible in small dogs using two 3-mm portal sites without additional incision.

Fractal dimension, lacunarity, and cortical thickness in the mandible: Analyzing differences between healthy men and women with cone-beam computed tomography

  • Ingrid Garcia Santos;Fernanda Ramos de Faria;Marcio Josse da Silva Campos;Beatriz Alvares Cabral de Barros;Gustavo Davi Rabelo;Karina Lopes Devito
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.153-159
    • /
    • 2023
  • Purpose: The objective of this study was to assess the fractal dimension, lacunarity, trabecular microarchitecture parameters, and cortical linear measurements in the mandibles of male and female individuals to identify differences between them. Materials and Methods: In total, 116 cone-beam computed tomography scans of healthy individuals of different ages (57 men and 59 women, aged between 20 and 60 years) were selected. The following bone parameters were measured: 1) buccal, lingual, and basal cortical bone thickness in 5 standard parasagittal sections (the midline, the left and right sides of the lower lateral incisors, and the left and right sides of the lower canines); 2) the bone volume fraction of 10 sequential axial sections from each patient by creating a volume of interest in the area between the lower canines; and 3) fractal dimension and lacunarity using grayscale images of the same region of the volume of interest in the anterior mandible. Spearman correlation coefficients and the Mann-Whitney test were used. Results: A significant and positive correlation was found between age and cortical thickness, especially in the region of the central incisors. Significant differences between sexes in terms of fractal dimension, lacunarity, and bone volume were found. Women revealed lower fractal dimension values and higher lacunarity and bone volume ratio values than men. Conclusion: Fractal dimension, lacunarity, trabecular bone volume, and cortical thickness were different between men and women of different ages.

The use of precontoured plates for midshaft clavicle fractures is not always the best course of treatment

  • Manmohan Patel;Mohtashim Ahmad;Natwar Agrawal;Sumit Tulshidas Patil;John Ashutosh Santoshi;Bertha Rathinam;Kusum Rajendra Gandhi
    • Anatomy and Cell Biology
    • /
    • v.56 no.4
    • /
    • pp.456-462
    • /
    • 2023
  • Plate fixation has become the preferred approach for treating displaced midshaft clavicle fractures. However, plate fixation of the clavicle presents several unique challenges, including its complex bony architecture and its immediate subcutaneous location. In many cases, we have observed that precontoured implants do not conform to the clavicular anatomy, and many patients complain of postoperative implant-related discomfort. A total of 111 clavicles, both left and right sides, were examined to match two commonly used designs of anatomical pre-contoured superior anterior clavicle plates, with and without lateral extension. The anteroposterior (AP) plane congruence of the plate to the underlying bone, the vertical gap between the bone and plate, and the length of the plate that was off the bone either anteriorly and/or posteriorly at both ends of the clavicle were measured. The scoring system was used to determine the fit of the implant on the clavicle as anatomic, good, or poor. We found that the maximum superior bow of the clavicle was lateral to the midline by 30.75 mm and 30.5 mm on the right and left sides, respectively. The magnitude of the bow was 4.28 mm and 4.46 mm on the right and left sides, respectively. We also found that the plate was a poor fit in 75.86% of cases on the left side and 73.5% of cases on the right side. Manipulating the plates during surgery was very difficult in the AP plane.

A Patient with Spinal Accessory Neuropathy after Self Neck Massage Treated with TMJ Balancing Therapy: A Case Report (경부 자가 마사지 후 척수부신경병증을 호소하는 환자의 턱관절균형요법 치험례)

  • Hakwon Kim;Jung Eun Choi;Sang Soo Park;Wang Jung Hur;Horyong Yoo;Miso S. Park
    • Journal of TMJ Balancing Medicine
    • /
    • v.13 no.sup
    • /
    • pp.27-33
    • /
    • 2023
  • The purpose of this study is to describe the effects of temporomandibular joint balancing therapy on a patient with a spinal accessory neuropathy. A patient reported sternocleidomastoid muscle and trapezius muscle weakness after self-massage. The patient was instructed to wear the Accurate Balancing Appliance (ABA) for at least 8 hours per day and maintain an upright posture. The patient received cervical spine manipulation on day 2, 4, and 6. The patient's progress was tracked based on the angle at which the head turned to the right from the midline when she lifted her head while lying down, as well as the muscle strength and pain in the right trapezius muscle. The patient recovered spontaneously after 7 days. The ABA and cervical spine manipulation assisted the patient in reducing fatigue and discomfort during daily activities.

  • PDF

DaVinci SP-based simultaneous bilateral partial nephrectomy from the midline transperitoneal approach: a case report

  • Young Hwii Ko;Jong Gyun Ha;Jae Yoon Jang;Yeung Uk Kim
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.1
    • /
    • pp.48-52
    • /
    • 2024
  • While simultaneous bilateral partial nephrectomy with a conventional multiport robot has been consistently reported since the 2010s, the introduction of the DaVinci SP system (Intuitive Surgical, Sunnyvale, CA, USA) could provide a novel way to perform surgery on bilateral kidneys while innovatively reducing the number of incisions. In our first report worldwide, the patient with bilateral small renal mass (2.0 cm for the left and 1.5 cm for the right side) and preoperative normal renal function was placed in the lateral decubitus position on an inverted bed. After tilting the bed to be as horizontal as possible, a 4-cm incision was made in the lower part of the umbilicus for the floating trocar technique. The partial nephrectomy was performed reliably as with the conventional transperitoneal approach, and then the patient could be repositioned to the contralateral side for the same procedure, maintaining all trocars. Total operation time (skin to skin), total console time, and the left- and right-side warm ischemic times were 260, 164, 27, and 23 minutes, respectively, without applying the early declamping technique. The estimated blood loss was 200 mL. The serum creatinine right after the operation, on the first day, 3 days, and 90 days after surgery were 0.92, 0.77, 0.79, and 0.81 mg/dL, respectively. For 90 days after the procedure, no complications or radiologic recurrence were observed. Further clinical studies will reveal the advantages of using the DaVinci SP device for this procedure over traditional multiport surgery, maximizing the benefit of a single port-based approach.

Utilization of Tissue Compensator for Uniform Dose Distribution in Total Body Irradiation (전신방사선조사시 균등한 선량분포를 이루기 위한 조직보상체의 이용)

  • Park, Seung-Jin;Chung, Woong-Ki;Ahn, Sung-Ja;Nam, Taek-Keun;Nah, Byung-Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.233-241
    • /
    • 1994
  • Purpose : This study was performed to verify dose distribution with the tissue compensator which is used for uniform dose distribution in total body irradiation(TBI). Materials and methods : The compensators were made of lead(0.8mm thickness) and aluminum(1mm or 5mm thickness) plates. The humanoid phantom of adult size was made of paraffin as a real treatment position for bilateral total body technique. The humanoid phantom was set at 360cm of source-axis distance(SAD) and irradiated with geographical field size(FS) $144{\times}144cm^2(40{\times}40cm^2$ at SAD 100cm) which covered the entire phantom. Irradiation was done with 10MV X-ray(CLINAC 1800, Varian Co., USA) of linear accelerator set at Department of Therapeutic Radiology, Chonnam University Hospital. The midline absorbed dose was checked at the various regions such as head, mouth, mid-neck, sternal notch, mid-mediastinum, xiphoid, umbilicus, pelvis, knee and ankle with or without compensator, respectively. We used exposure/exposure rate meter(model 192, Capintec Inc., USA) with ionization chamber(PR 05) for dosimetry, For the dosimetry of thorax region TLD rods of $1x1x6mm^3$ in volume(LiF, Harshaw Co., Netherland) was used at the commercially available humanoid phantom. Results : The absorbed dose of each point without tissue compensator revealed significant difference(from $-11.8\%\;to\;21.1\%$) compared with the umbilicus dose which is a dose prescription point in TBI. The absorbed dose without compensator at sternal notch including shoulder was $11.8\%$ less than the dose of umbilicus. With lead compensator the absorbed doses ranged from $+1.3\%\;to\;-5.3\%$ except mid-neck which revealed over-compensation($-7.9\%$). In case of aluminum compensator the absorbed doses were measured with less difference(from $-2.6{\%}\;to\;5.3\%$) compared with umbilicus dose. Conclusion : Both of lead and aluminum compensators applied to the skull or lower leg revealed a good compensation effect. It was recognized that boost irradiation or choosing reference point of dose prescription at sternal notch according to the lateral thickness of patient in TBI should be considered.

  • PDF