• Title/Summary/Keyword: Microwave-irradiation

Search Result 287, Processing Time 0.032 seconds

Microwave-assisted Weak Acid Hydrolysis of Proteins

  • Seo, Mi-Yeong;Kim, Jin-Hee;Park, Se-Hwan;Lee, Ji-Hye;Kim, Tae-Hee;Lee, Ji-Hyeon;Kim, Jeong-Kwon
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.47-49
    • /
    • 2012
  • Myoglobin was hydrolyzed by microwave-assisted weak acid hydrolysis with 2% formic acid at $37^{\circ}C$, $50^{\circ}C$, and $100^{\circ}C$ for 1 h. The most effective hydrolysis was observed at $100^{\circ}C$. Hydrolysis products were investigated using matrixassisted laser desorption/ionization time-of-flight mass spectrometry. Most cleavages predominantly occurred at the C-termini of aspartyl residues. For comparison, weak acid hydrolysis was also performed in boiling water for 20, 40, 60, and 120 min. A 60- min weak acid hydrolysis in boiling water yielded similar results as a 60-min microwave-assisted weak acid hydrolysis at $100^{\circ}C$. These results strongly suggest that microwave irradiation has no notable enhancement effect on acid hydrolysis of proteins and that temperature is the major factor that determines the effectiveness of weak acid hydrolysis.

Clinical Result of Combined Radiotherapy and Hyperthermia Induced by 915 MHz Microwave and Ultrasound in Locally Advanced Malignant Tumors of Head and Neck (915 MHz 극초단파 및 초음파를 이용한 온열치료와 방사선치료 병합치료에 의한 두경부암의 치료성적)

  • Koh Kyoung-Hwan;Park Young-Hwan;Cho Chul-Koo;Yoo Seong-Yul
    • Korean Journal of Head & Neck Oncology
    • /
    • v.6 no.1
    • /
    • pp.40-45
    • /
    • 1990
  • Thirty five lesions of 35 patients with locally advanced malignant tumors of head and neck were received thermoradiotherapy with ultrasound and/or 915 MHz microwave. Most of all patients were failed with previous conventional therapeutic trial. Hyperthermia had been done immediately after radiotherapy, twice a week, $43^{\circ}C$ for one hour and radiotherapy had been done 5 fractions per week with a fraction size of 2 Gy up to total 30 to 60 Gy. Conclusions are as follows; 1) Total response rate (CR+PR) of thermoradiotherapy with microwave and ultrasound was 80%. 2) Tumor depth, minimum temperature of tumor center, number of heat fraction and irradiation dose were statistically significant factors affecting response. 3) Hyperthermia with microwave and ultrasound can be used efficiently to control locally advanced malignant tumors in head and neck whether previously received near tolerance dose of radiotherapy or not.

  • PDF

Luminescent Properties of Y2O3:Eu Red Phosphor Particles Prepared by Microwave Synthesis (마이크로웨이브 합성법으로 제조한 Y2O3:Eu 적색 형광체의 발광 특성)

  • Maniquiz, Meriel Chua;Kang, Tae-Won;Ahn, Jin-Han;Jung, Kyeong-Youl
    • Journal of Powder Materials
    • /
    • v.16 no.3
    • /
    • pp.203-208
    • /
    • 2009
  • $Y_2O_3$:Eu red phosphor was prepared by microwave synthesis. The crystal phase, particle morphology, and luminescent properties were characterized by XRD, SEM, and spectrofluorometer, respectively. The prepared $Y_2O_3$:Eu particles had good crystallinity and strong red emission under ultravioletet excitation. The crystallite size increased with calcination temperature and satuarated at $1200^{\circ}C$. The primary particle size initially formed was varied from 30 to 450 nm with microwave-irradiation (MI) time. It was found that the emission intensity of $Y_2O_3$:Eu phosphor strongly depends on the MI time. In terms of the emission intensity, it was recommended that the MI time should be less than 15 min. The emission intensity of $Y_2O_3$:Eu phosphor prepared by microwave syntehsis strongly depended on the crystallite size of which an optimal size range was 50-60 nm.

Improvement of Histopathological Sample Preparation by Employing Microwave Heating Method on Frozen Section Specimens

  • Ahn, Seung-Ju
    • Biomedical Science Letters
    • /
    • v.13 no.4
    • /
    • pp.361-368
    • /
    • 2007
  • Biological samples can be fixed either by chemical method by using chemical solution or physical methods by using heat treatment. The problem in traditional heat fixation is unsatisfactory quality due to uneven heat conduction in specimen and loss of inner cell contents. Chemical fixation method also bears several intrinsic problems like the limit in specimen size, time consumption in fixative impregnation, and loss of low molecular weight cell components. These factors deteriorate the quality of fixed specimen, thus limit the magnification and contrast of tissue pictures. Microwave heat has been reported to be a good alternative to current chemical methods to overcome these problem. In this study, we tried to introduce the microwave energy method to routine fixation work in hospital. We replaced chemical fixative with saline to provide moderate reaction condition, and used frozen section to reduce time for sample preparation. Temperature was measured at each experiment. The fixation of rat kidney tissue with 2.45 GHz electromagnetic wave and saline showed similar result to the control group fixed with traditional chemical method. Human tumor tissue fixed with 2.45 GHz electromagnetic in frozen section was improved in terms of histochemistry of PAS and immunohistochemistry of tumor marker like cytokeratin. Total turnaround time was reduced from $24\sim38$ h to to $2\sim4$ h. In conclusion, the quality of samples prepared by microwave heating method was at least as good as that of traditional method. If the condition for the fixation of different specimens is standardized, this new method could be applied to routine work in hospital, and could save working time as well.

  • PDF

Optimization of Pre-Treatment Conditions for Hydrocarbons Detection from Irradiated Soybean Using Microwave-Assiated Extraction (마이크로파 추출법을 이용한 방사선 조사 대두의 Hydrocarbons 분석 전처리조건 최적화)

  • Lee, Jeong-Eun;Kwon, Joong-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.612-621
    • /
    • 2013
  • Microwave-assisted extraction (MAE), which is known as less time and less solvent than current extraction methods, was applied to hydrocarbons extraction from irradiated soybean. Among the transported agricultural products, soybean was selected as representative samples for possible application of irradiated treatment and identification of radiation-induced markers. Using 4 kGy-irradiated soybean, different microwave extraction conditions (extraction time and microwave power) were applied and the changes in hydrocarbon concentrations were monitored. The predicted optimum extracted condition for hydrocarbon analysis of soybean was found to be microwave extraction with a microwave power of 97 W and extraction time of 2.2 min. This extraction time was significantly lower compared to the common extraction time of 12-24hr.

The Microwave-assisted Photocatalytic Degradation of Methylene Blue Solution Using TiO2 Balls Prepared by Chemical Vapor Deposition (CVD법으로 제조된 산화티탄 볼과 마이크로웨이브를 이용한 메틸렌블루 수용액의 광촉매분해)

  • Park, Sang-Sook;Park, Jae-Hyeon;Kim, Sun-Jae;Jung, Sang-Chul
    • Korean Chemical Engineering Research
    • /
    • v.46 no.6
    • /
    • pp.1063-1068
    • /
    • 2008
  • The photocatalytic degradation of methylene blue water solution was carried out by irradiating microwave and UV light simultaneously using $TiO_2$ photocatalyst balls prepared by Chemical Vapor Deposition method. A microwave-discharged electrodeless UV lamp was developed to use microwave and UV simultaneously for photocatalytic reactions. The results of photocatalytic degradation of methylene blue showed that the decomposition rate increased with the microwave intensity, the circulating fluid velocity and auxiliary oxidizing agents added. Especially, the rate constant of $H_2O_2$-added photocatalytic reaction increased about three times from $0.0061min^{-1}$ to $0.0197min^{-1}$ when microwave was additionally irradiated. This study demonstrates that the microwave irradiation can play a very important role in photocatalytic degradation using peroxides although it is not easy to quantitatively assess the effect of microwave on photocatalytic reactions from the experimental data of this study.

Changes of Microorganisms and Active Compounds in Glycyrrhizae Radix as Affected by Drying Method and Gamma Ray Treatments (건조 방법 및 감마선 조사에 따른 감초의 미생물 저감효과 및 유효성분 변화)

  • Kim, Joon-Hee;Kang, Byoung-Man;Kim, Jun Yong;Kim, Ryu-Dam;Hwang, Hyun Chul;Lee, Jae-Woong
    • Korean Journal of Plant Resources
    • /
    • v.35 no.4
    • /
    • pp.428-434
    • /
    • 2022
  • Glycyrrhizae Radix is an herbal medicine vulnerable to fungi. So there are regulations on mycotoxins. Therefore, in this study, the affect of various drying methods and additional gamma irradiation (10 kGy) was studied to suppress the microbial generation of Glycyrrhizae Radix. As a result of detecting and comparing microorganisms using the dry film method for samples prepared by each of natural, hot air, freezing, microwave drying and gamma irradiation, the affect of reducing microorganisms by microwave drying and gamma irradiation was confirmed. There was no statistically significant change in the content of the active compounds between the treatment groups.

Peroxidative Damage in Rat Liver Exposed to Microwave (전자기파 조사 흰쥐 간조직에서의 과산화적 손상)

  • Choi, Jeong-Hwa;Shin, Hyun-Jin;Yu, Heum;Lee, Jun-Ha;Rhee, Soon-Jae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.6
    • /
    • pp.1262-1266
    • /
    • 1998
  • The purpose of this study was to investigate peroxidative damage and antioxidative defense systems such as superoxide dismutase(SOD), glutathione peroxidase(GSH Px), glutathione S transferase (GST) and vitamin E of liver in rat exposed microwave. Sprague Dawley male rats 200$\pm$10gm were randomly assigned to normal and microwave(MW) groups. After rats were irradiated with microwave at frequency of 2.45GHz for 15min, the change patterns of antioxidative defense system and peroxidative damage of liver tissue in MW group were investigated for 16 days(the 2nd, 4th, 6th, 8th and 16th days) compared with those of normal group. The activity of superoxide dismutase(SOD) in MW group was increased at the 2nd day compared with that of normal group, but not significantly. The glutathione peroxidase(GSH Px) in MW group was decreased to 24% and 25% at the 4th and 6th days, respectively, compoared with that of normal group, but GSH Px was increased to level of normal group at the 16th day. The activity of glutathione S transferase(GST) in MW group was decreased at the 2nd day after irradiated with microwave, but GST showed to that of normal group at the 16th day. The content of vitamin E in MW group was lower than that of normal group at the 6th and 8th days after the irradiation, but was recovered to the level of normal group at the 16th days. The content of thi obarbituric acid reactive substances(TBARS) of liver in MW group was increased to 28.9%, 53.8%, 69.7% and 30.2% of normal group at the 2nd, 4th, 6th and 8th days after the irradiation, respectively, but recovered to the level of normal group at the 16th day. The present results indicated that antiox idative defense systems of rats irradiated microwave was weaken more than that of normal group, which lead to acceleration of lipid peroxidation.

  • PDF

Moisture Content Change and Heat Distribution Characteristics of Veneer Heated by Microwave (마이크로파 가열 단판의 함수율 변화 및 열분포 특성)

  • Shin, Ki-Hoon;Suh, Jin-Suk;Park, Cheul-Woo;Lim, Nam-Gi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.407-419
    • /
    • 2014
  • The analysis of shape before and after heating, Surface moisture content, Moisture weight change and surface heat distribution by fixed type microwave heating in forms of flat veneer and veneer roll of Korean pine, pitch pine, larch and yellow poplar was conducted. The results were as follows: In case of flat veneer, the quality after microwave heating was comparatively good, but it was somewhat warped. These phenomena may be due to transformation by nonuniform drying stress and stronger effect of local irradiation on the veneers when heating veneer owing to the characteristics of fixed type microwave equipment. In case of the features of roll-shaped veneer heated by microwave, the quality after heating was comprehensively excellent. Especially there was no warping unlike flat veneer. Heat distribution and diffusion were also very stable for roll-shaped veneer and such heat distribution had much influence on surface moisture content and moisture weight loss. Accordingly, the veneer roll would show sufficient drying efficiency in fixed type microwave equipment through a scrutinized examination on generating power and irradiation time according to species and thickness of veneer.

Dispersion Effect Based on Irradiation Dose and Position of QRD Microwave in Sealed Chamber (밀폐된 챔버의 QRD 마이크로파 조사용량과 위치에 따른 분산효과)

  • Kim, Jin Hyun;Han, Chung Su;Lee, Keun Woo;Lim, Kyoung Ho;Lee, Jae Hyun;Kim, Kyung Min;Ha, Yu Shin
    • Journal of Bio-Environment Control
    • /
    • v.23 no.1
    • /
    • pp.1-10
    • /
    • 2014
  • This study analyzed the efficiency and uniformity by measuring the temperature change depending on the position in the chamber with the use of QRD (quadratic residue diffusor) microwave capable of inducing even sterilization by changing wavelength phase difference and enhancing the effect on low power. The results are summarized as follows: When irradiating 7 kW of QRD microwave, the highest efficiency was obtained at 35 cm height and in the center of the chamber. When irradiating 5 kW of QRD microwave, high efficiency was obtained on the sides of the chamber. When irradiating 3 kW of QRD microwave to Magnetrons 1, 2 and 3, the temperature uniformity according to the position of the bars was similar in the position of Bar 1 and 2. When irradiating 3 kW of QRD microwave to Magnetrons 3, 4 and 5, the temperature increased by approximately 10 to 20% in Bar 3. When irradiating 5, 7 and 9 kW of magnetron, the average temperature during the irradiation time increased in a similar form independently of the position of the bars. On the other hand, the efficiency of the chamber's proper internal volume was not necessarily proportional to the irradiation dose. When irradiating 3 kW of magnetron for 60 120 and 180 seconds, the temperature increased by approximately 5 to 10 at the edge of the chamber according to the irradiation position of magnetron. The temperature distribution for each position in the horizontal plane was relatively uniform, and the temperature had a tendency to slightly increase at the edge. When irradiating 5, 7 and 9 kW of magnetron, the temperature relatively evenly increased independently of the position of the bars. It was thought necessary to increase the irradiation dose by approximately 10 to 20% by considering the difference in temperature rise according to the position of magnetron.