• Title/Summary/Keyword: Microguidewire

Search Result 2, Processing Time 0.013 seconds

Microguidewire Looping to Traverse Stented Parent Arteries of Intracranial Aneurysms

  • Cho, Young Dae;Rhim, Jong Kook;Yoo, Dong Hyun;Kang, Hyun-Seung;Kim, Jeong Eun;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.2
    • /
    • pp.262-268
    • /
    • 2017
  • Objective : Stents are widely used in coil embolization of intracranial aneurysms, but on occasion, a microcatheter must traverse a stented segment of artery (so-called trans-cell technique) to select an aneurysm, or double stenting may necessary. In such situations, microguidewire passage and microcatheter delivery through a tortuous stented parent artery may pose a technical challenge. Described herein is a microguidewire looping technique to facilitate endovascular navigation in these circumstances. Methods : To apply this technique, the microguidewire tip is looped before entering the stented parent artery and then advanced distally past the stented segment, with the loop intact. Rounding of the tip prevents interference from stent struts during passage. A microcatheter is subsequently passed into the stented artery for positioning near the neck of aneurysm, with microguidewire assistance. The aneurysm is then selected, steering the microcatheter tip (via inner microguidewire) into the dome. Results : This technique proved successful during coil embolization of nine saccular intracranial aneurysms (internal carotid artery [ICA], 6; middle cerebral artery, 2; basilar tip, 1), performing eight trans-cell deliveries and one additional stenting. Selective endovascular embolization was enabled in all patients, resulting in excellent clinical and radiologic outcomes, with no morbidity or mortality directly attributable to microguidewire looping. Conclusion : Microguidewire looping is a reasonable alternative if passage through a stented artery is not feasible by traditional means, especially at paraclinoid ICA sites.

Use of a Rigid-Tipped Microguidewire for the Endovascular Treatment of Cavernous Sinus Dural Arteriovenous Fistulas with an Occluded Inferior Petrosal Sinus

  • Deniwar, Mohamed Adel;Kwon, Boseong;Song, Yunsun;Park, Jung Cheol;Lee, Deok Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.688-696
    • /
    • 2022
  • Objective : Transvenous embolization (TVE) via an occluded inferior petrosal sinus (IPS) in a cavernous sinus dural arteriovenous fistula (CSDAVF) is challenging, often requiring navigation of a microcatheter through resistive obstacles between the occluded IPS and shunted pouch (SP), although the reopening technique was successfully performed. We report five cases of successful access to the cavernous sinus (CS) or SP using the rigid-tipped microguidewire such as chronic total occlusion (CTO) wire aiming to share our initial experience with this wire. Methods : In this retrospective study, four patients with CSDAVF underwent five procedures using the CTO wire puncture during transfemoral transvenous coil embolization. Puncture success, shunt occlusion, and complications including any hemorrhage and cranial nerve palsy were evaluated. Results : Despite successful access through the occluded IPS, further entry into the target area using neurointerventional devices was impossible due to a short-segment stricture before the CS (three cases) and a membranous barrier within the CS (two cases). However, puncturing these structures using the rigid-tipped microguidewire was successful in all cases. We could advance the microcatheter over the rigid-tipped microguidewire for the navigation to the SP and achieved complete occlusion of the SP without complications. Conclusion : The use of the rigid-tipped microguidewire in the TVE via the occluded IPS of the CSDAVF would be feasible and safe.