• Title/Summary/Keyword: Micro-strip

Search Result 103, Processing Time 0.026 seconds

A Study on the Linearization of Power Amplifier (전력 증폭기의 선형화 기술에 관한 연구)

  • Lee Seung-Dae;Han Yung-Oh
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.3
    • /
    • pp.429-436
    • /
    • 2005
  • The linear modulation method which has high spectrum efficiency when applying in mobile communication system, the problem occurs. In order to solve like this problem non-linearity characteristic of the power amplifier linearity against the method which it does it investigated. It used a design objection and it implemented the microwave power amplifier. The amplifier which it produces used the micro-strip line and when it imput power 13 dBm from center frequency, the possibility of getting the output power of 28 dBm.

  • PDF

Simultaneous Quantitative Determination of Multiple Analytes with Fluorescence- Tagged Probes by Immunochromatogratphy

  • Jeong, Dong-Seok;Choi, Eui-Yul
    • Animal cells and systems
    • /
    • v.7 no.1
    • /
    • pp.89-92
    • /
    • 2003
  • Immunoassays have become indispensable tools and achieved great importance in scientific and medical research. However, typical immunoassays are time-consuming and use complex, multi-step procedures. In this study, we introduce a new immunoassay system for the quantification of several analytes at a time without any washing steps. It is comprised of a detector solution with fluorescence-labeled antibodies and a test strip with immobilized capture antibodies. Using a micro-array scanner, the antigen-antibody complex was quantitatively determined by measuring the intensities of fluorescence on the capture lines or dots of nitrocellulose membrane. This method demonstrated its rapid quantitative determination of analytes without many processing steps as well as specific identification of multiple analytes in biological specimens.

Base Station Antenna of Radiation Pattern for the Cruciform using Monopole Array (도심지 교차로 지형에 맞는 방사패턴 형성을 위한 기지국용 모노폴 어레이 안테나)

  • 문상만;우종명;신헌철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.964-970
    • /
    • 2002
  • In this paper, cruciform radiation pattern antenna was designed and fabricated. The fabricated antenna is applicable to intersections which is composed of four eight-lane roads each having 60 m of width and 200 m of length. The design theory was based on Woodward-Lawson method and the 6 monopole elements with the strip feeding network are made by linear array on the micro-strip board. In the results, - 13.5 dB of return loss and 120 MHz(6 %) of -10 dB bandwidth were obtained at the 2 GHz. Also, at 1.95 GHz, -6 dB of gain fall was seen at $\pm$45$^{\circ}$ and thus, it is possible to say that the presented antenna has well-shaped cruciform radiation pattern.

EVALUATION AND DEVELOPMENT OF DIGITAL DEVICE FOR MEASURING PROXIMAL TOOTH CONTACT TIGHTNESS (디지털 방식의 인접면 접촉강도 측정장치의 개발 및 평가)

  • Choi, Woo-Jin;Kim, Kyung-Hwa;Kim, Jin-A;Kang, Dong-Wan;Oh, Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.5
    • /
    • pp.687-695
    • /
    • 2007
  • Statement of problem: The proper contact relation between adjacent teeth in each arch plays an important role in the stability and maintenance of the integrity of the dental arches. Proximal contact has been defined as the area of a tooth that is in close association, connection, or touch with an adjacent tooth in the same arch. Purpose: The aim of this study was to develop a digital device for measuring the proximal tooth contact tightness by pulling a thin stainless steel strip (2mm wide, 0.03mm thick) inserted between proximal tooth contact. Material and method: This device consists of measuring part, sensor part, motor part and body part. The stainless steel strip was connected to a stain gauge. The strain gauge was designed to convert the frictional force into a compressive force. This compressive force was detected as a electrical signal and the electrical signal was digitalized by a A/D converter. The digital signals were displayed by a micro-processor. The pulling speed was 8mm/s. Results: For testing reliability of the device in vivo, two healthy young adults (A, B) participated in this experiment. The tightness of proximal tooth contact between the second premolar and the first molar of mandible (subject A) and maxilla (subject B) was measured fifteen times for three days at rest. We double-checked the accuracy of the device with a Universal Testing Machine. Output signals from the Universal Testing Machine and the measuring device were compared. Regression analysis showed high linearity between these two signals. In vivo test, no significant differences were found between measurements. Conclusion: This device has shown to he capable of producing reliable and reproducible results in measuring proximal tooth contact. Therefore, it was considered that this device was appropriate to apply clinically.

Calculation of Primary Electron Collection Efficiency in Gas Electron Multipliers Based on 3D Finite Element Analysis (3차원 유한요소해석을 이용한 기체전자증폭기의 1차 전자수집효율의 계산)

  • Kim, Ho-Kyung;Cho, Min-Kook;Cheong, Min-Ho;Shon, Cheol-Soon;Hwang, Sung-Jin;Ko, Jong-Soo;Cho, Hyo-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • Gas avalanche microdetectors, such as micro-strip gas chamber (MSGC), micro-gap chamber (MGC), micro-dot chamber (MDOT), etc., are operated under high voltage to induce large electron avalanche signal around micro-size anodes. Therefore, the anodes are highly exposed to electrical damage, for example, sparking because of the interaction between high electric field strength and charge multiplication around the anodes. Gas electron multiplier (GEM) is a charge preamplifying device in which charge multiplication can be confined, so that it makes that the charge multiplication region can be separate from the readout micro-anodes in 9as avalanche microdetectors possible. Primary electron collection efficiency is an important measure for the GEM performance. We have defined that the primary electron collection efficiency is the fractional number of electron trajectories reaching to the collection plane from the drift plane through the GEM holes. The electron trajectories were estimated based on 3-dimensional (3D) finite element method (FEM). In this paper, we present the primary electron collection efficiency with respect to various GEM operation parameters. This simulation work will be very useful for the better design of the GEM.

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.

An optical true time delay for 10 GHz linear phased array antennas composed of optical 2×2 MEMS switches and fiber delay lines (광 2×2 MEMS 스위치와 광섬유 지연선로를 이용한 10 GHz 선형 위상배열 안테나용 광 실시간 지연선로)

  • 이백송;신종덕;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.466-472
    • /
    • 2003
  • In this paper, we proposed an optical true time-delay (TTD) feeder system for phased array antennas (PAAs). The system possesses high-speed beam scan capability since, in this scheme, different lengths of fiber delay-lines are selected by optical 2${\times}$2 MEMS switches at high speed. An optical TTD capable of beam scanning in one of eight different directions has been built for 10 GHz linear PAA systems. Experimental results on time delay measurements show that the maximum time delay error is less than 0.2 ps corresponding to a scan angle error of less than 0.84o. We have also designed a 10 GHz linear PAA composed of eight micro-strip patch antenna elements driven by the proposed TTD, and the radiation patterns of this PAA have been analyzed by simulation.

Fabrication of Micro Patterned Fibronectin for Studying Adhesion and Alignment Behavior of Human Dermal Fibroblasts

  • Lee, Seung-Jae;Son, Young-Sook;Kim, Chun-Ho;Choi, Man-Soo
    • Macromolecular Research
    • /
    • v.15 no.4
    • /
    • pp.348-356
    • /
    • 2007
  • The aim of this study was to fabricate a submicro-and micro-patterned fibronectin coated wafer for a cell culture, which allows the positions and dimensions of the attached cells to be controlled. A replica molding was made into silicon via a photomask in quartz, using E-beam lithography, and then fabricated a polydimethylsiloxane stamp using the designed silicon mold. Hexadecanethiol $[HS(CH_2){_{15}}CH_3]$, adsorbed on the raised plateau of the surface of polydimethylsiloxane stamp, was contact-printed to form self-assembled monolayers (SAMs) of hexadecanethiolate on the surface of an Au-coated glass wafer. In order to form another SAM for control of the surface wafer properties, a hydrophilic hexa (ethylene glycol) terminated alkanethiol $[HS(CH_2){_{11}}(OCH_2CH_2){_6}OH]$ was also synthesized. The structural changes were confirmed using UV and $^1H-NMR$ spectroscopies. A SAM terminated in the hexa(ethylene glycol) groups was subsequently formed on the bare gold remaining on the surface of the Aucoated glass wafer. In order to aid the attachment of cells, fibronectin was adsorbed onto the resulting wafer, with the pattern formed on the gold-coated wafer confirmed using immunofluorescence staining against fibronectin. Fibronectin was adsorbed only onto the SAMs terminated in the methyl groups of the substrate. The hexa (ethylene glycol)-terminated regions resisted the adsorption of protein. Human dermal fibroblasts (P=4), obtained from newborn foreskin, only attached to the fibronectin-coated, methyl-terminated hydrophobic regions of the patterned SAMs. N-HDFs were more actively adhered, and spread in a pattern spacing below $14{\mu}m$, rather than above $17{\mu}m$, could easily migrate on the substrate containing spacing of $10{\mu}m$ or less between the strip lines.

Material Properties of Ni-P-B Electrodeposits for Steam Generator Tube Repair

  • Kim, Dong Jin;Seo, Moo Hong;Kim, Joung Soo
    • Corrosion Science and Technology
    • /
    • v.3 no.3
    • /
    • pp.112-117
    • /
    • 2004
  • This work investigated the material properties of Ni-P-B alloy electrodeposits obtained from a Ni sulfamate bath as a function of the contents of the P and B sources($H_3PO_3$ and dimethyl amine borane complex(DMAB), respectively) with/without additives. Chemical composition, residual stress, microstructure and micro hardness were investigated using ICP(inductively coupled plasma) mass spectrometer, flexible strip, XRD, TEM and micro Vickers hardness tester, respectively. From the results of the compositional analysis, it was observed that P and B are incorporated competitively during the electrodeposition and the sulfur from the additive is codeposited into the electrodeposit. The measured residual stress value increased in the order of Ni, Ni-P, Ni-B and Ni-P-B electrodeposits indicating that boron affects the residual tensile stress greater than phosphorus. As the contents of the alloying element sources of P and B increased, crystallinity and the grain size of the electrodeposit decreased. The effect of boron on crystallinity and grain size was also relatively larger than the phosphorus. It can be explained that the boron with a smaller atomic radius contributes to the increase of residual stress in the tensile direction and the larger restraining force against the grain growth more significantly than the phosphorus with a larger atomic radius. Introduction of an additive into the bath retarded crystallization and grain growth, which may be attributed to the change of the grain growth kinetics induced by the additive adsorbed on the substrate and electrodeposit surfaces during electrodeposition.

A Study of the Properties of Optically Induced Layers in Semiconductors Aided by the Reflection of Optically Controlled Microwave Pulses

  • Wang, Xue;Choi, Yue-Soon;Park, Jong-Goo;Kim, Yong-K.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.4
    • /
    • pp.111-115
    • /
    • 2009
  • We present a study on the reflection of optically controlled microwave pulses from non uniform plasma layers in semiconductors. The transient response of the microwave pulses in different plasma layers has been evaluated by means of the reflection function of dielectric microstrip lines. The lines were used with an open-ended termination containing an optically induced plasma region, which was illuminated by a light source. The reflection characteristics impedance resulting from the presence of plasma is evaluated by means of the equivalent transmission line model. We have analyzed the variation of the transient response in a 0.01 cm layer with a surface frequency in the region of 128 GHz. In the reflection the variation of the diffusion length $L_D$ is large compared with the absorption depth $1/{\alpha}_l$. The variation of the characteristic response of the plasma layer with differentially localized pulses has been evaluated analytically. The change of the reflection amplitude has been observed at depths of 0.1 cm, 0.01 cm and $0.1{\times}10^{-5}$ cm respectively.