• 제목/요약/키워드: Micro-particle

검색결과 737건 처리시간 0.024초

Mn계 합금의 수소 저장에 대한 입자크기의 영향 (The effect of particle size on hydrogen storage of Mm-based alloys)

  • 박찬교;배장순;조범식
    • 한국수소및신에너지학회논문집
    • /
    • 제11권4호
    • /
    • pp.171-177
    • /
    • 2000
  • Metal hydride used as hydrogen storage material usually needs the activating process to store the hydrogen at high temperature or high pressure. In general as the particle size of metal hydride becomes smaller, approached to the micro, furthermore, nano scale, storage ability and reaction kinetics are reported to be increased, because the specific surface is extremely increased. But the experimental results demonstrated that the optimum particle size is existed for the best absorbing performance, opposite to the usual expectation. This results from the particles to be come amorphous with their approaching to micro and nano scale, in the storage site within the metal hydride lattice is decreased, which is proved by XRD and SEM.

  • PDF

A systematic approach to the calibration of micro-parameters for the flat-jointed bonded particle model

  • Zhou, Changtai;Xu, Chaoshui;Karakus, Murat;Shen, Jiayi
    • Geomechanics and Engineering
    • /
    • 제16권5호
    • /
    • pp.471-482
    • /
    • 2018
  • A flat-jointed bonded-particle model (BPM) has been proved to be an effective tool for simulating mechanical behaviours of intact rocks. However, the tedious and time-consuming calibration procedure imposes restrictions on its widespread application. In this study, a systematic approach is proposed for simplifying the calibration procedure. The initial relationships between the microscopic, constitutive parameters and macro-mechanical rock properties are firstly determined through dimensionless analysis. Then, sensitivity analyses and regression analyses are conducted to quantify the relationships, using results from numerical simulations. Finally, four examples are used to demonstrate the effectiveness and robustness of the proposed systematic approach for the calibration procedure of BPMs.

마이크로 미립 이송시스템 개발에 관한 연구 (Development of Feeding System by Micro Particle Powder)

  • 박정수
    • 한국산업정보학회논문지
    • /
    • 제8권3호
    • /
    • pp.105-110
    • /
    • 2003
  • 본 연구에서는 마이크로미립 이송시스템의 에어 누수가 과다함으로 인해 압축에어를 사용하는 큰 문제점을 발생되어 로터리피더의 에어누수를 기존대비 50% 감소시켰으며 생산제조원가 면에서도 기존가격의 60%수준으로 개발함으로써 원료의 원활한 이송이 될 수 있는 장치의 개발에 대해 입증하였다.

  • PDF

New Retention System Using Branched Polymer

  • Son, Dong-Jin;Kim, Bong-Yong
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2006년도 PAN PACIFIC CONFERENCE vol.2
    • /
    • pp.251-256
    • /
    • 2006
  • The purpose of this study was to confirm multiple retention system of C-PAM, A-PAM and Inorganic micro particles vs. traditional micro particle system and dual polymer system by measuring retention, drainage and formation using RDA HSF and Techpap 2D -F Sensor The benefits of dual polymer system were easy to use, low chemical consumption and good retention property but defect was worse drainage property than inorganic microparticle systems. On the other hand, Inorganic microparticle system had benefit of good drainage effect but defects were difficult to use, high chemical consumption. Therefore, we tried to find optimal morphology of polyacrylamide and applied to multiple retention system of C-PAM, A-PAM and inorganic microparticles to compensate defects of both of retention systems. As a result, we found the performance of branched C-PAM, branched A-PAM and inorganic micro particle triple system was more appropriate than traditional inorganic mircoparticle systems or dual polymer systems by comparing retention, drainage and formation.

  • PDF

Innovations in Micro Metal Injection Molding Process by Lost Form Technology

  • Nishiyabu, Kazuaki;Kanoko, Yasuhiro;Tanaka, Shigeo
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.43-44
    • /
    • 2006
  • The production method of micro sacrificial plastic mold insert metal injection molding, namely ${\mu}-SPiMIM$ process has been proposed to solve specific problems involving the miniaturization of MIM. Two types of sacrificial plastic molds (SP-mold) with fine structures were used: 1) PMMA resist, 2) PMMA mold injected into Ni-electroform, which is a typical LIGA (${\underline{L}}ithographie-{\underline{G}}alvanoformung-{\underline{A}}bformung$) process. Stainless steel 316L feedstock was injection-molded into the SP-molds with multi-pillar structures. This study focused on the effects of metal particle size and processing conditions on the shrinkage, transcription and surface roughness of sintered parts.

  • PDF

Characteristics of micro-plastics in stormwater sediment basin: Case study of J wetland

  • Jiyeol Im;Kyungik Gil
    • Membrane and Water Treatment
    • /
    • 제14권4호
    • /
    • pp.147-153
    • /
    • 2023
  • Urbanization has been causing such new pollutants as micro-plastic, thus the environmental impact of new pollutants on ecosystem is rapidly increasing. When it comes to micro-plastic, a representative artificial trace pollutant, its risk has been increased at a much faster rate, however the depth study associated with stormwater sediment and wetland was relatively rare. In this research, soil samples from storm water sediment were analyzed for distribution characteristics of micro-plastics in the J wetland (registered as Ramsar wetland, May 2021 and a representative environmental site in South Korea). Analyzed soil samples found approximately 201 ± 93 particle/kg (based on unit weight, Total micro plastic particles / Total Sample weight) micro-plastics in the samples. When considering the total quantitative numbers in stormwater sediment in the entire area of the J wetland, over 15,000 micro-plastics were estimated to be contaminating such area. In addition, in terms of qualitative numbers, micro-plastics were contaminating the J wetland with 94.7 % ratio of styrofoam type (43.9%) and polyethylene type (50.8%). These research results can be used as base data sets for controlling micro-plastics in the J wetland.

Distributions of Mean Particle Size and Age on the Lunar Surface

  • Jung, Min-Sup;Kim, Sung-Soo S.;Min, Kyoung-Wook
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.103.2-103.2
    • /
    • 2011
  • We measure the degree of polarization of the lunar regolith to map the distributions of the age and the particle size. We use a 12cm refracting telescope with a 2k-square pixel color CCD (R band) and a polarization filter. The angular resolution obtained is 3.02 km/pixel. Our goal is to obtain a map of the lunar particle size distribution on the lunar regolith and then that of the age distribution. Polarization of the light scattered by lunar surface contains information on their mean particle size. The mean particle size of the lunar surface has been decreased by continued micro-meteoroid impact over a long period. One can estimate the age of the lunar surface if the mean particle size is known. Particle sizes can be measured through observations of polarization because the mean particle size is related to the maximum polarization and albedo. The age and the particle size of the lunar regolith can give vital information for the future lunar exploration.

  • PDF

Visualization of micro-interfacial conditions using Micro PIV

  • OKAMOTO Koji;SHINOHARA Kyosuke;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.111-118
    • /
    • 2004
  • A new micro-resolution PIV (Particle Image. Velocimetry) has been developed. To investigate transient phenomena in a microfluidic device, Dynamic micro-PIV system was realized by combining a high-speed camera and a CW(Continuous Wave) laser. The technique was applied to a micro-counter-current flow, consisting of water and butyl acetate. The velocity fields of water in the micro counter-current flow were visualized for a time resolution of 500 $\{mu}s$ and a spatial resolution of 2.2 x 2.2 $\{mu}m$. Using the Dynamic micro-PIV technique, the vortex-like motions of fluorescent particles at the water-butyl acetate interface were captured clearly

  • PDF

Numerical Simulation of the Effect of Finite Diaphragm Rupture Process on Micro Shock Tube Flows

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.309-317
    • /
    • 2012
  • Recent years have witnessed the use of micro shock tube in various engineering applications like micro combustion, micro propulsion, particle delivery systems etc. The flow characteristics occurring in the micro shock tube shows a considerable deviation from that of well established conventional macro shock tube due to very low Reynolds number and high Knudsen number effects. Also the diaphragm rupture process, which is considered to be instantaneous process in many of the conventional shock tubes, will be crucial for micro shock tubes in determining the near diaphragm flow field and shock formation. In the present study, an axi-symmetric CFD method has been applied to simulate the micro shock tube, with Maxwell's slip velocity and temperature jump boundary conditions. The effects of finite diaphragm rupture process on the flow field and the shock formation was investigated, in detail. The results show that the shock strength attenuates rapidly as it propagates through micro shock tubes.

  • PDF

미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명 (Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip)

  • 이재우;곽태준;윤대성;이상우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권4호
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.