• 제목/요약/키워드: Micro-contact measurement

검색결과 85건 처리시간 0.027초

Sensing Technology for Rapid Detection of Phosphorus in Water: A Review

  • Islam, Sumaiya;Reza, Md Nasim;Jeong, Jin-Tae;Lee, Kyeong-Hwan
    • Journal of Biosystems Engineering
    • /
    • 제41권2호
    • /
    • pp.138-144
    • /
    • 2016
  • Purpose: Phosphorus is an essential element for water quality control. Excessive amounts of phosphorus causes algal bloom in water, which leads to eutrophication and a decline in water quality. It is necessary to maintain the optimum amount of phosphorus present. During the last decades, various studies have been conducted to determine phosphorus content in water. In this study, we present a comprehensive overview of colorimetric, electrochemical, fluorescence, microfluidic, and remote sensing technologies for the measurement of phosphorus in water, along with their working principles and limitations. Results: The colorimetric techniques determine the concentration of phosphorus through the use of color-generating reagents. This is specific to a single chemical species and inexpensive to use. The electrochemical techniques operate by using a reaction of the analyte of interest to generate an electrical signal that is proportional to the sample analyte concentration. They show a good linear output, good repeatability, and a high detection capacity. The fluorescence technique is a kind of spectroscopic analysis method. The particles in the sample are excited by irradiation at a specific wavelength, emitting radiation of a different wavelength. It is possible to use this for quantitative and qualitative analysis of the target analyte. The microfluidic techniques incorporate several features to control chemical reactions in a micro device of low sample volume and reagent consumption. They are cheap and rapid methods for the detection of phosphorus in water. The remote sensing technique analyzes the sample for the target analyte using an optical technique, but without direct contact. It can cover a wider area than the other techniques mentioned in this review. Conclusion: It is concluded that the sensing technologies reviewed in this study are promising for rapid detection of phosphorus in water. The measurement range and sensitivity of the sensors have been greatly improved recently.

은계 필러메탈 브레이징 접합부의 특성 분석 (Analysis of Bonding Characteristics of Ag-System Brazing Filler Metal)

  • 이순길;이화인;손진오;하광일;구본흔
    • 한국재료학회지
    • /
    • 제33권5호
    • /
    • pp.214-221
    • /
    • 2023
  • As a filler metal for lowering the melting point of Ag, many alloy metal candidates have emerged, such as cadmium, with zinc, manganese, nickel, and titanium as active metals. However, since cadmium is known to be harmful to the human body, Cd-free filler metals are now mainly used. Still, no study has been conducted comparing the characteristics of joints prepared with and without cadmium. In addition, studies have yet to be conducted comparing the typical characteristics of brazing filler metals with special structures, and the joint characteristics of brazing filler metals with available frames. In this study, the characteristics of junctions of silver-based intercalation metals were compared based on the type of filler metal additives, using a special structure, a filler metal sandwich structure, to protect the internal base metal. The general filler metal was compared using the structure, and the thickness of the filler metal according to the thickness was reached. A comparison of the characteristics of the junction was conducted to identify the characteristics of an intersection of silver-based brazing filler metal and the effect on joint strength. Each filler metal's collective tensile strength was measured, and the relationship between joint characteristics and tensile joint strength was explored. The junction was estimated through micro strength measurement, contact angle measurement with the base metal when the filler metal was melted, XRD image observation, composition analysis for each phase through SEM-EDS, and microstructure phase acquisition.

자체-감지능 및 광투과도를 지닌 CNT 및 ITO/PET 다기능성 나노복합소재의 계면 조절 연구 (Interfacial Control of Multi-functional CNT and ITO/PET Nanocomposites having Self-Sensing and Transparency)

  • 왕작가;권동준;구가영;박종만
    • Composites Research
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2011
  • 자체-감지능 있는 다기능성 나노복합소재를 위해, 투명하고 전도성 있는 카본나노튜브 (CNT)로 코팅된 폴리에틸렌 테레프탈레이트(PET)를 함침 방법으로 제조하였다. CNT 코팅의 전기적 광학적 특정의 변화는 함침 횟수와 CNT용액의 농도에 주로 의존하였다. 결과적으로, CNT 코팅의 표면저항과 투과도는 제조공정의 변수들에 따라 예민하게 조절되었다. CNT 코팅의 표면저항은 4점법과 이중 배열법에 의해 측정되었으며, 광학적 투과도는 UV 스펙트럼을 사용하여 평가하였다. CNT 코팅의 표면특성을 측정한 정적 및 동적 접촉각은 상호 일치함을 보여주었다. 함침 코팅수가 증가함에 따라, CNT코팅한 PET의 표면저항은 현저하게 저하했으나, 투명도는 CNT 네트워크의 특성으로 거의 감소하지 않았다. CNT와 인듐틴옥사이드 (ITO)의 계면 및 전기적 특성들은 피로 시험을 통하여 비교하였다. CNT는 2000회 반복 후에도 표면저항의 변화가 없는 반면에, ITO는 1000회 반복까지 표면저항의 급격한 증가를 보여주었다가 안정화하였다. 이는 형상비가 큰 CNT는 전기 접촉점을 계속 유지하는 반면에, 취성이 있는 ITO는 미세 균열이 발생하여 전지 접촉점을 많이 상실하기 때문이다.

전기적-미세역학시험법과 음향방출을 이용한 단일 탄소섬유/탄소나노튜브-에폭시 나노복합재료의 자체-감지능 (Self-Sensing of Single Carbon Fiber/Carbon Nanotube-Epoxy Composites Using Electro-Micromechanical Techniques and Acoustic Emission)

  • 박종만;장정훈;왕작가;권동준;박종규;이우일
    • 비파괴검사학회지
    • /
    • 제30권5호
    • /
    • pp.411-422
    • /
    • 2010
  • 탄소나노튜브-에폭시 복합재료의 미세손상에 대한 자체-감지도와 분산도와 관련되는 특성 연구가 접촉각, 전기-미세역학 시험법 및 음향방출을 통하여 수행하였다. 시편들은 미처리와 산처리된 탄소나노튜브가 첨가된 에폭시 복합재료와 순수 에폭시로 제조되었다. 상대적인 분산도는 부피 전기저항도와 그 표준편차로 평가하였다. 응력전달을 나타내는 겉보기 탄성율은 미처리 탄소나노튜브 복합재료보다 산처리된 경우가 크게 나타났다. 단일 탄소섬유/탄소나노튜브-에폭시 복합재료는 부가한 반복 하중에 대해서 접촉저항도의 변화로 잘 감지되었다 섬유 풀-아웃 시험에서 단일 탄소섬유와 탄소나노튜브-에폭시간의 계면접착강도는 순수 에폭시의 경우보다 작았다. 음향방출과 함께 전기저항측정을 통한 미세파손 감지는, 전도성 있는 탄소나노튜브-에폭시 복합재료에서는 단일 탄소섬유 파손에 대한 단계적인 전기저항도의 증대를 보여 주었으나, 순수 에폭시의 경우는 첫번째 탄소섬유의 파단의 경우 바로 저항이 무한대로 증대함을 보여주었다. 첨가한 탄소나노튜브의 미세계면 손상으로 인하여, 음향방출 발생이 나노복합재료가 순수 에폭시에 비하여 훨씬 증대하였다.

레이저 기반 패키징 공정에서 광 다이오드 기반 플랑크 온도 측정법(PDPT)의 적용 및 성능 평가 (Application and Performance Evaluation of Photodiode-Based Planck Thermometry (PDPT) in Laser-Based Packaging Processes)

  • 위찬웅;이준원;우재형;정하경;정지훈;한승회
    • 마이크로전자및패키징학회지
    • /
    • 제31권2호
    • /
    • pp.63-68
    • /
    • 2024
  • 최근 투명 디스플레이 및 유연 소자의 활용도가 증가함에 따라 우수한 유연성과 강성을 갖는 폴리머 소재 기판의 사용이 증가하고 있다. 그러나 폴리머는 열에 취약하여 공정 중 온도 및 열 제어가 필수적이다. 이러한 폴리머 기판 활용의 단점을 해결하기 위해 본 연구에서는 레이저 기반의 선택적 가공 기술에 적용할 수 있는 폴리머 기판 내 레이저 가공영역의 온도 측정 시스템을 제안한다. 레이저 가공 영역의 국부적인 온도 변화 측정을 통해 폴리머 기판의 공정 조건을 최적화하는 가능성을 제시한다. 이를 위해 플랑크 흑체 복사 원리를 기반으로 한 PDPT(Photodiode based Planck Thermometry)를 설계 및 제작하여 레이저가 입사되는 영역의 온도를 측정하였다. PDPT는 비파괴/비접촉식 온도측정 시스템으로, 레이저가 입사되는 국부적인 온도 상승을 실시간으로 측정할 수 있다. 해당 시스템을 활용하여 폴리머 기판의 레이저 가공 공정에서 발생하는 가공영역의 온도 변화를 관측하였다. 본 연구 결과, 제안된 레이저 기반 온도측정 기술은 레이저 가공 공정 중 실시간 온도 측정이 가능하며, 이를 통해 최적의 생산 조건을 확립할 가능성을 보여주고 있다. 또한, 해당 기술은 열 제어가 필수적인 미세 레이저 가공 및 3차원 프린팅과 같은 다양한 레이저 기반 공정에 적용될 수 있을 것으로 기대된다.

도시철도 레일연마주기 산정을 위한 시험적 연구 (Experimental Study for Establishing Rail Grinding Period in the Urban Railway)

  • 성덕룡;고동춘;박용걸;공선용
    • 한국철도학회논문집
    • /
    • 제13권4호
    • /
    • pp.447-454
    • /
    • 2010
  • 레일 피로 열화손상유형들은 크게 레일표면에서 발생하는 결함들과 레일내부에서 진전되어 발생하는 결함들로 구분되어질 수 있다. 본 연구에서는 국내에서 연간 누적통과톤수가 가장 많은 도시철도의 운행조건을 고려하여 현장측정을 통해 레일표면 요철성장률을 분석하였으며, 연마 후 누적통과톤수에 따른 시험편을 현장에서 발췌하여 현미경을 이용한 조직검사, 화학성분검사, 마이크로 비커스 경도시험을 수행하였다. 시험결과 신품레일의 경우 유효탈탄층 제거를 위해 약 0.3mm의 초기연마를 시행해야하며, 예방연마의 경우 전구간을 일괄적으로 연마할 경우와 특정 구간별로 구분하여 연마할 경우에 대하여 2가지 방안을 제시하여 레일표면에서 발생하는 RCF결함을 예방하거나 제거할 수 있도록 제시하였다.

Model test on slope deformation and failure caused by transition from open-pit to underground mining

  • Zhang, Bin;Wang, Hanxun;Huang, Jie;Xu, Nengxiong
    • Geomechanics and Engineering
    • /
    • 제19권2호
    • /
    • pp.167-178
    • /
    • 2019
  • Open-pit (OP) and underground (UG) mining are usually used to exploit shallow and deep ore deposits, respectively. When mine deposit starts from shallow subsurface and extends to a great depth, sequential use of OP and UG mining is an efficient and economical way to maintain mining productivity. However, a transition from OP to UG mining could induce significant rock movements that cause the slope instability of the open pit. Based on Yanqianshan Iron Mine, which was in the transition from OP to UG mining, a large-scale two-dimensional (2D) model test was built according to the similar theory. Thereafter, the UG mining was carried out to mimic the process of transition from OP to UG mining to disclose the triggered rock movement as well as to assess the associated slope instability. By jointly using three-dimensional (3D) laser scanning, distributed fiber optics, and digital photogrammetry measurement, the deformations, movements and strains of the rock slope during mining were monitored. The obtained data showed that the transition from OP to UG mining led to significant slope movements and deformations that can trigger catastrophic slope failure. The progressive movement of the slope could be divided into three stages: onset of micro-fracture, propagation of tensile cracks, and the overturning and/or sliding of slopes. The failure mode depended on the orientation of structural joints of the rock mass as well as the formation of tension cracks. This study also proved that these non-contact monitoring technologies were valid methods to acquire the interior strain and external deformation with high precision.

전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석 (Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition)

  • 손근수;김동수;김경동;김종민
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.15-27
    • /
    • 2020
  • 하천 유량관측은 수자원의 관리를 위해 활용되는 기초적이고 대표적인 자료로 하천에서 정확한 유량을 관측하는 것은 중요하다. 따라서 최근에는 다양한 첨단 장비들이 개발되어 전통적인 하천의 유량관측을 대체하거나 보완하고 있다. 여러 최신 장비들 중 전자파표면유속계는 홍수기와 같이 하천에 접근하여 직접유량계측이 위험하고 정확도 확보가 어려울 경우전자파를 이용하여 비접촉식으로 유량을 계측하는 장비로 홍수기 및 평갈수기에도 하천 유량계측에 활용되기 시작하였다. 전자파표면유속계는 사용법이 간단하고 간접적으로 유속을 측정하기 때문에 기존의 직접측정 방법에 비해 안전한 장점이 있어 현재 국내에서는 홍수기 또는 접근이 어려운 하천의 유속 측정을 위해 사용되고 있다. 국내에서는 1993년 유량측정 장치 개발을 위해 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)를 개발을 연구를 수행하였고, 최근에는 국내에서 개발된 전자파표면유속계을 활용하여 유량측정을 위해 사용되고 있다. 하지만 국내에서 개발된 전자파표면유속계가 실제 하천에서 유속측정의 정확도에 대한 연구는 부족한 실정이다. 전자파표면유속계는 기기로부터 전자파를 이용해 유속을 측정하기 때문에 수직각과 편각과 같은 각도 변화에 따라 측정정확도가 바뀔 수 있고, 전자파표면유속계 본체에서 발사되는 전자파의 측정영역에 따라 유속측정에 오차가 발생할 수 있다. 본 연구에서는 국내에서 개발 전자파표면유속계의 측정정확도를 분석하기 위해서 실제하천과 유사한 실규모 하천수로에서 수직각과 편각을 변화시키며 측정을 수행하여 수직각과 편각에 변화에 따른 유속측정 정확도를 분석하였다. 그리고 전자파표면유속계의 측정영역의 고려를 통해서 측정영역에 따른 유속측정결과를 분석하였다. 유속측정 결과를 통해서 수직각 15° 이하에서는 유속측정의 오차가 커지게 되는 것으로 나타났고, 편각이 커질수록 유속측정의 결과의 변동계수가 커지는 것으로 나타났다. 그리고 편각에 따른 오차의 영향은 전자파표면유속계의 측정영역에 따라 결과가 달라지는 것으로 나타났다.

Research of Non-integeral Spatial Interpolation for Precise Identifying Soybean Location under Plastic Mulching

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2017년도 춘계공동학술대회
    • /
    • pp.156-156
    • /
    • 2017
  • Most crop damages have been occurred by vermin(e.g., wild birds and herbivores) during the period between seeding and the cotyledon level. In this study, to minimize the damage by vermin and acquire the benefits such as protection against weeds and maintenance of water content in soil, immediately vinyl mulching after seeding was devised. Vinyl mulching has been generally covered with black color vinyl, that crop seeding locations cannot be detected by visible light range. Before punching vinyl, non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. For this study, the spline method was relatively faster than the other polynomial interpolation methods, because it has a lower maximum order of formulation when using a system such as the tridiagonal linear equation system which provided the capability of real-time processing. The temperature distribution corresponding to the distance between the crops was 10 cm, and the more clearly the leaf pattern of the crop was visually confirmed. The frequency difference was decreased, as the number of overlapped pixels was increased. Also the wave pattern of points where the crops were recognized were reduced.

  • PDF

다양한 기판 위에서 고분자 전해질 다층 막과 폴리에틸렌글리콜 미세 구조물을 이용한 세포 패터닝 방법 (Cell Patterning on Various Substrates Using Polyelectrolyte Multilayer and Microstructure of Poly(Ethylene Glycol))

  • 심현우;이지혜;최호석;이창수
    • Korean Chemical Engineering Research
    • /
    • 제46권6호
    • /
    • pp.1100-1106
    • /
    • 2008
  • 본 연구는 표면에 세포를 부착하는데 있어서, 다양한 기판 표면에 보편적인 플랫폼으로써 적용될 수 있는 세포 부착을 위한 기능성 표면의 제작 기술 및 이를 이용한 세포의 선택적인 고정과 편리한 세포 패터닝의 방법을 보여주었다. 세포 부착에 적합한 기능성 표면의 제작은 산소 플라즈마 처리를 이용한 다양한 기판의(유리, PMMA, PS, PDMS) 표면 활성화 및 상반되는 고분자 전해질의(PAH, PDAC, PSS, PAA) 정전기적 인력을 통한 증착으로 이루어진 다층의 고분자 전해질 층을 통해 제작될 수 있었다. 또한, 고분자 전해질로 증착된 표면 위로 마이크로 몰딩 인 케필러리 방법을 사용하여 PEG 마이크로 구조물을 제작함으로써 세포의 선택적인 고정이 이루어질 수 있었다. 다층의 고분자 전해질로 증착된 표면은 세포와의 강한 정전기적 인력으로 세포 부착에 유리한 표면을 제공하였다. 반면에, 제작된 PEG 마이크로 구조물은 물리적, 생물학적인 장애물의 역할로써 세포의 비 특이적인 흡착을 방지하였다. 세포 부착을 위한 기능성 표면을 제작하는 동안 표면의 특성은 접촉각 측정을 통해 이루어 졌다. 다양한 기판 상에서 개질된 표면은 세포 부착을 위한 적합한 환경의 제공과 함께 세포의 마이크로 패터닝 기술에서 높은 수율의 세포 패터닝을 제공한다. 상기의 제안된 세포 부착을 위한 기능성 표면 제작 기술 방법은 제작 과정이 매우 간단하고, 편리하여 손쉽게 구현이 가능하며, 제작 공정에서 어떠한 해로운 용매도 사용하지 않기 때문에 친환경적이다. 또한, 이를 이용하여 세포를 이용하는 바이오 칩 및 바이오 센서, 세포를 기반으로 하는 시스템 등에서 기본이 되는 기술로 사용될 수 있는 넓은 응용 범위를 갖는다.