• Title/Summary/Keyword: Micro-channel array

Search Result 30, Processing Time 0.047 seconds

A Study of Micro-Channel Fabrication by Micro-Milling and Magnetic Abrasive Deburring (마이크로 밀링과 자기디버링을 적용한 마이크로 유동채널 가공)

  • Kwak, Tae-Kyung;Kwak, Jae-Seob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.8
    • /
    • pp.899-904
    • /
    • 2011
  • This This study aims to verify burr formation and to remove the burrs in micro-channel fabrication using micro-machining tools. The machining processes are combined with micro-milling and magnetic abrasive deburring for AISI316 stainless steel. Depending on the micro-milling conditions that are applied, burrs are formed around the side walls. Magnetic abrasive deburring is used to remove these burrs. AISI316 stainless steel is a nonferrous material and its magnetic flux density, which is an important parameter for efficient magnetic abrasive deburring, is low. To enhance this magnetic flux density, we design and build a magnetic array table. The effect of removing burrs is evaluated via SEM and a surface tester.

Development of Multi-Array Electrode and Programmable Multi-channel Electrical Stimulator for Firing Trigger Point of Myofascial Pain Syndrome (근막통증증후군의 통증유발점 치료를 위한 멀티어레이 전극과 프로그램 가능한 다채널 전기자극기 개발)

  • Kim, SooHong;Kim, SooSung;Jeon, GyeRok
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.221-227
    • /
    • 2015
  • In this study, Multi-Array Electrodes (MAE) and Programmable Multi-channel Electrical Stimulator (PMES) were implemented for firing Trigger Points (TPs) of the patient with Myofascial Pain Syndrome (MPS). MAE has 25 Ag/AgCl electrodes arranged in the form of array ($5{\times}5$) fabricated with flexible pad, which are applicable to be easy-attached to curved specific region of the human body. PMES consisted of 25 channels. Each channel was to generate various electric stimulus patterns (ESPs) by changing the mono-phasic or bi-phasic of ESP, On/Off duration of ESP, the interval between ESP, and amplitude of ESP. PMES hardware was composed of Host PC, Stimulation Pattern Editing Program (SPEP), and Multi-channel Electrical Stimulator (MES). Experiments were performed using MAE and PMES as the following. First experiment was performed to evaluate the function for each channel of Sub- Micro Controller Unit (SMCU) in MES. Second experiment was conducted on whether ESP applied from each channel of SMCU in PMES was focused to the electrode set to the ground, after applying ESP being output from each channel of SMCU in PMES to MAE.

A study on Manufacturing of Micro Dotting Pin (바이오용 마이크로 핀의 제작에 관한 연구)

  • Lee, Young-Soo;Km, Kwang-Soon;Kim, Byeong-Hee
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.21-27
    • /
    • 2003
  • The bio-micro pin is usually used for biochemistry analysis. The capability of manufacturing the micro-pin and array with effective and low-cost way is very important to developers. The micro-pin is composed of "sample channel" putting liquid into already fixed volume, "flat tip" having connection with printing quantity, and "head part" for preventing it from rotation of pin in the holder. We analyzed out printing variation in accordance with shape and tip size of the micro-pin point channel, In this study, we suggested the manufacturing progress and shape demand condition of the micro-pin which could put $0.2{\mu}{\ell}$-biochemistry material into the sample volume, and will be able to produce the micro-pin which can put $10n{\ell}$-biochemistry material into the sample volume in the future.

  • PDF

A Study on the Ultrasonic Sensor Array for the Mobile Robot (모빌 로보트의 초음파 센서열에 관한 연구)

  • Yoon, Y.B.;Lee, S.M.;Choi, H.H.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1256-1259
    • /
    • 1987
  • This paper gives a new SRF (Sonic Range Finder) Array formation on the mobile robot. This SRF Array formation obtaine the mobile robot's environmental informations wider and faster than the other systems and detects the obstacles in the robot's path. It is processed and controlled by 8031, on-chip micro-computer. SRF Array sensors are drived by the LM1812 transceiver and selected by the 8-channel channel multiplexer. In this paper, it detects the obstacles in wider range and gives them to the MAIN to design the shortest modify path.

  • PDF

CHANGE OF CHANNEL-FLOW TOPOLOGY BY A STREAMWISE-PERIODIC ARRAY OF ROTATING CIRCULAR CYLINDERS (주기적으로 배열된 회전하는 원형 실린더를 이용한 채널유동 토폴로지 변화)

  • Jeong, Taekyeong;Yang, Kyung-Soo;Lee, Kyongjun;Kang, Changwoo
    • Journal of computational fluids engineering
    • /
    • v.18 no.4
    • /
    • pp.17-24
    • /
    • 2013
  • In this study, we consider the characteristics of channel flow in the presence of an infinite streamwise array of equispaced identical rotating circular cylinders. This flow configuration can be regarded as a model representing a micro channel or an internal heat exchanger with cylindrical vortex generators. A numerical parametric study has been carried out by varying Reynolds number based on the bulk mean velocity and the cylinder diameter, and the gap between the cylinders and the channel wall for some selected angular speeds. An immersed boundary method was employed to facilitate implementing the cylinders on a Cartesian grid system. No-slip condition is employed at all solid boundaries including the cylinders, and the flow is assumed to be periodic in the streamwise direction. The presence of the rotating circular cylinders arranged periodically in the streamwise direction causes a significant topological change of the flow, leading to increase of mean friction on the channel walls. More quantitative results as well as qualitative physical explanations are presented to justify the effectiveness of rotating cylinders to modify flow topology, which might be used to enhance heat transfer on the channel walls.

Design of the Medical Thermal Array Printer Module Based on Microcontroller (마이크로 콘트롤러를 이용한 의료용 열전식 프린터 모듈의 개발에 관한 연구)

  • Lee, Myoungho;Kong, Inwook;Kwon, Hyukje
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.129-138
    • /
    • 1996
  • This paper describes design techniques of general purpose thermal array printer, especially easily applicable to medical measurement equipment. The'general'means that the proposed thermal array printer can be applied to not only medical field but other industrial field by establishing the eligible protocol. The thermal array printer is composed of i)MPU and its peripherals ii)printer head control, iii)diverse protection circuits, and iv)serial communication. In this paper the performance of the proposed thermal array printer was evaluated by applying to an 3 channel electrocardiogram recorder. The propped system can support'Hangul'text as well as alphanumeric characters and any bitmap image.

  • PDF

Effect of surface roughness on laminar flow in a micro-channel by using lattice Boltzmann method (격자 볼츠만 방법을 이용한 미소채널 내에서의 층류 유동에 대한 표면 거칠기의 영향)

  • Shin, Myung-Seob;Yoon, Joon-Yong;Byun, Sung-Joon;Kim, Kak-Joong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.179-183
    • /
    • 2006
  • Surface roughness is present in most of the microfluidic devices due to the microfabrication techniques. This paper presents lattice Boltzmann method (LBM) results for laminar flow in a microchannel with surface roughness. The surface roughness is modeled by an array of rectangular modules placed on top and bottom side of a parallel-plate channel. In this study, LBGK D2Q9 code in lattice Boltzmann Method is used to simulate flow field for low Reynolds number in a micro-channel. The effects of relative surface roughness, roughness distribution, roughness size and the results are presented in the form of the product of friction factor and Reynolds number. Finally, a significant increase in Poiseuille number is detected as the surface roughness is considered, while the effect of roughness on the microflow field depends on the surface roughness.

  • PDF

Local heat transfer measurement inside microchannel (마이크로채널에서의 국소 열전달 측정)

  • Cho, Dae-Gwan;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1902-1907
    • /
    • 2008
  • The current work presents a design and fabrication technique for a microchannel system to measure the local temperature distribution inside microchannel. This micro channel system fabricated by MEMS technique is integrated with a heater and an array of temperature sensors so that detailed heat transfer phenomena inside micro-scale channel can be studied. Materials widely used in semiconductor process were selected to fabricate a heater and temperature sensors on a silicon wafer. On these heater and sensors a channel wall was fabricated with SU-8. The friction constant and the local Nusselt number distribution measured for the deionized water flow in the microchannel is presented.

  • PDF

A Disposable BioChip for Single Cell Manipulation

  • Yoon, Euisik
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2004.10a
    • /
    • pp.1-15
    • /
    • 2004
  • o Various microfluidic components including mixromixers and micropumps have been developed for disposable biochip applications. o Single cell capturing, positioning and nanoliter drug injection chip has been demostrated. o Multi-channel, two-dimensional micro-well array has been fabricated and cell capturing and specific reagent injection have been performed.

  • PDF

Manufacturing of Micro Dotting Pin (DNA Chip 용 마이크로 핀에 관한 연구)

  • 신홍규;이영수;남권선;김병희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.500-504
    • /
    • 2004
  • The bio-micro pin has been usually used for the biochemistry analysis. The manufacturing capability of the micro-pin and the their array with the effective and low-cost way is very important and it gives great economical benefits to developers. The micro-pin is composed of the sample channel for holding the liquid with the fixed volume, the flat tip which determines the printing quality and the pin head for preventing the rotation of the pin in the holder. In this study, we have manufactured newly designed micro-pins by the wire-EDM process with special jigs, and analyzed liquid holding and printing characteristics with respect to the variation of the shape and the tip size of the micro-pin.

  • PDF