• Title/Summary/Keyword: Micro-Thermopile

Search Result 11, Processing Time 0.042 seconds

Characteristics and Fabrication of Optimal Thermopile on SiNx Membrane for Microspectrometer (마이크로 스펙트로미터 적외선 센서용 저응력 SiNx Membrane상에서의 최적화된 Thermopile 제작 및 특성)

  • Kim, Dong-Sik
    • 전자공학회논문지 IE
    • /
    • v.44 no.1
    • /
    • pp.6-9
    • /
    • 2007
  • Twenty four types of thermopile for micro spectrometer infrared sensors were fabricated on low-stress Si3N4 membranes with $l.2{\mu}m-thickness$ using MEMS technology. Thermopile were designed and fabricated for optimum conditions by five parameters of thermocouple numbers $(16\sim48)$, thermocouple line widths $(10{\mu}m-25{\mu}m)$, thermocouple lengths $(100{\mu}m-500{\mu}m)$, membrane areas $(12mm2\sim2.52mm2)$ and junction areas $(150{\mu}m2\sim750{\mu}m2)$, respectively. It was thought that measurement results could be used for thermopile infrared sensors optimum structure for micro spectrometers.

Fabrication and evaluation of a micro heat flux sensor using thermopile (열전대를 이용한 미세 열유속 센서의 제작 및 평가)

  • Kim Jung-Hoon;Kim Bum-Seok;Cho Hyung-Hee;Kim Yong-Jun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1210-1213
    • /
    • 2005
  • Micro heat flux sensor is used in various industries to measure heat flux. In this study, a micro heat flux sensor is fabricated using the MEMS (Micro Electro Mechanical Systems) techniques. The fabricated sensor is composed in thermopile for sensor and SU-8 for thermal resistance layer. The new method of fabrication SU-8 is proposed in this study. The sensitivity is $44\;\mu{V/(W/cm^2)}$ at steady state and Reynolds number is 91322.

  • PDF

Fabrication and Characterization of Thermopile on Low-Stress $Si_3N_4$ Membrane for Microspectrometer Infrared Sensor (마이크로 스펙트로미터 적외선 센서용 저응력 $Si_3N_4$ Membrane 상에서의 Thermopile 제조 및 특성)

  • Choi, Gong-Hee;Park, Kwang-Bum;Park, Joon-Shik;Chung, Kwan-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.781-784
    • /
    • 2005
  • Twenty four types of thermopile for micro spectrometer infrared sensors were fabricated on low-stress $Si_3N_4$ membranes with $1.2{\mu}m-thickness$ using MEMS technology. Poly-Si thin film with thickness of 3500 ${\AA}$ as the first thermocouple material, was deposited by LPCVD method. And aluminum thin film with thickness of 6000 ${\AA}$ as the second thermocouple material, was deposited by sputtering method. Thermopile were designed and fabricated for optimum conditions by five parameters of thermocouple numbers (16 ${\sim}$ 48), thermocouple line widths (10 ${\mu}m$ ${\sim}$ 25 ${\mu}m$), thermocouple lengths (100 ${\mu}m$ ${\sim}$ 500 ${\mu}m$), membrane areas ($1^2\;mm^2$ ${\sim}$ $2.5^2\;mm^2$) and junction areas (150 ${\mu}m^2$ ${\sim}$ 750 ${\mu}m^2$), respectively. Electromotive forces of fabricated thermopile were measured 1.1 mV ${\sim}$ 7.4 mV at $400^{\circ}C$. It was thought that measurement results could be used for thermopile infrared sensors optimum structure for micro spectrometers.

  • PDF

THE STUDY OF HEAT TRANSFER IN THERMOPILE THERMOMETER

  • Youn, ChongHo;Fujita, Toshinori;Kawashima, Kenji;Kagawa, Toshiharu;Ichida, Syuji;Tomohito, Hayashi
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.387-390
    • /
    • 2001
  • Thermopile thermometer can measure the temperature of an object without attaching the object. It measures the temperature by receiving the radiation energy from objects. The idea of this is from the law of Stefan-Boltzmann. In the past it was not used well because the size was big and the cost was too expensive. But, In these days it can be used many field because the size become smaller and advantage of cost by using micro machine technology. However, The accuracy of measuring is not better than electric type. So we want to improve the accuracy of sensor by analyzing the heat transfer of the thermopile. To analyze temperature distribution in the thermopile sensor, we use the FEM software which is named ANSYS. The conduction and radiation heat transfer is considered to simulate the temperature distribution and time response inside of the sensor.

  • PDF

Fabrication of MEMS Devices Using SOI(Silicon-On-Insulator)-Micromachining Technology (SOI(Silicon-On-Insulator)- Micromachining 기술을 이용한 MEMS 소자의 제작)

  • 주병권;하주환;서상원;최승우;최우범
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.874-877
    • /
    • 2001
  • SOI(Silicon-On-Insulator) technology is proposed as an alternative to bulk silicon for MEMS(Micro Electro Mechanical System) manufacturing. In this paper, we fabricated the SOI wafer with uniform active layer thickness by silicon direct bonding and mechanical polishing processes. Specially-designed electrostatic bonding system is introduced which is available for vacuum packaging and silicon-glass wafer bonding for SOG(Silicon On Glass) wafer. We demonstrated thermopile sensor and RF resonator using the SOI wafer, which has the merits of simple process and uniform membrane fabrication.

  • PDF

The Micro Heat Flux Sensor using Electroplated Copper layers (구리 도금층을 이용한 미세 열유속 센서)

  • 오석환;전재철;김무환;이승섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.226-231
    • /
    • 2000
  • New types of the micro heat flux sensor are designed and fabricated using SU-8 and Cu electroplating. And then calibrated under convection environment. The thermal path was made by SU-8 structure and electroplated Cu layers. The bottom surface of the micro heat flux sensor receives the heat flux from the wall, Then the heat flows along the Cu layers and drains out to the environment with producing the temperature difference at the upper layer of Cu. By measuring this temperature difference, the heat flux from the wall can be obtained. The temperature difference is measured by thermopile which is composed of Ni-Cr pairs or Al-chromel pairs. The calibration is accomplished under convection environment because it is most frequent situation. The range of the sensitivity is 0.11~2.02$\mu$V/(㎽/$\textrm{cm}^2$) for the various heat flux and Reynolds numbers.

  • PDF

Design of The Micro Fluidic Heat Flux Sensor (유동형 미세 열유속 센서의 설계)

  • Kim, Jung-Kyun;Cho, Sung-Cheon;Lee, Sun-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.11
    • /
    • pp.138-145
    • /
    • 2009
  • A suspended membrane micro fluidic heat flux sensor that is able to measure the heat flow rate was designed and fabricated by a complementary-metal-oxide-semiconductor-compatible process. The combination of a thirty-junction gold and nickel thermoelectric sensor with an ultralow noise preamplifier, low pass filter, and lock-in amp has enabled the resolution of 50 nW power and provides the sensitivity of $11.4\;mV/{\mu}W$. The heater modulation method was used to eliminate low frequency noises from sensor output. It is measured with various heat flux fluid of DI-water to test as micro fluidic application. In order to estimate the heat generation of samples from the output measurement of a micro fluidic heat-flux sensor, a methodology for modeling and simulating electro-thermal behavior in the micro fluidic heat-flux sensor with integrated electronic circuit is presented and validated. The electro-thermal model was constructed by using system dynamics, particularly the bond graph. The electro-thermal system model in which the thermal and the electrical domain are coupled expresses the heat generation of samples converts thermal input to electrical output. The proposed electro-thermal system model shows good agreement with measured output voltage response in transient state and steady-state.

Numerical Analysis on the Design of a Thermal Mass Air Flow Sensor with Various Heating Modes (가열모드에 따른 열식 질량유량센서의 설계 해석)

  • Jeon, Hong-Kyu;Lee, Joon-Sik;Park, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.876-883
    • /
    • 2007
  • Numerical simulations are conducted for the design of a micro thermal mass air flow sensor (MAFS), which consists of a microfabricated heater and thermopiles on the silicon-nitride ($Si_3N_4$) thin membrane structure. It is important to find the proper locations of these thermal elements in the design of MAFS with improved sensitivity. Three heating modes of the micro-heater are considered: constant temperature, constant power and heating pulses. The analyses are focused on the membrane temperature profile near the sensing section. Considered are the practical flow velocities, ranging from 3 m/s to 35 m/s, and the corresponding Reynolds numbers from 1000 to 10000. The results show that one of optimum sensing locations is about $100{\mu}m$ away from the microheater. It is concluded that the heating mode and configurations of thermal elements are the main factors for the MAFS with higher sensitivity.