• 제목/요약/키워드: Micro-RIA

검색결과 3건 처리시간 0.019초

Development of Microfluidic Radioimmunoassay Platform for High-throughput Analysis with Reduced Radioactive Waste

  • Jin-Hee Kim;So-Young Lee;Seung-Kon Lee
    • 대한방사성의약품학회지
    • /
    • 제8권2호
    • /
    • pp.95-101
    • /
    • 2022
  • Microfluidic radioimmunoassay (RIA) platform called µ-RIA spends less reagent and shorter reaction time for the analysis compared to the conventional tube-based radioimmunoassay. This study reported the design of µ-RIA chips optimized for the gamma counter which could measure the small samples of radioactive materials automatically. Compared with the previous study, the µ-RIA chips developed in this study were designed to be compatible with conventional RIA test tubes. And, the automatic gamma counter could detect radioactivity from the 125I labeled anti-PSA attached to the chips. Effects of the multi-layer microchannels and two-phase flow in the µ-RIA chips were investigated in this study. The measured radioactivity from the 125I labeled anti-PSA was linearly proportional to the number of stacked chips, representing that the radioactivity in µ-RIA platform could be amplified by designing the chips with multi-layers. In addition, we designed µ-RIA chip to generate liquid-gas plug flow inside the microfluidic channel. The plug flow can promote binding of the biomolecules onto the microfluidic channel surface with recirculation in the liquid phase. The ratio of liquid slug and air slug length was 1 : 1 when the 125I labeled anti-PSA and the air were injected at 1 and 35 µL/min, respectively, exhibiting 1.6 times higher biomolecule attachment compared to the microfluidic chip without the air injection. This experimental result indicated that the biomolecular reaction was improved by generating liquid-gas slugs inside the microfluidic channel. In this study, we presented a novel µ-RIA chips that is compatible with the conventional gamma counter with automated sampler. Therefore, high-throughput radioimmunoassay can be carried out by the automatic measurement of radioactivity with reduced radiowaste generation. We expect the µ-RIA platform can successfully replace conventional tube-based radioimmunoassay in the future.

Technology Acceptance Model of Financial Technology in Micro, Small, and Medium Enterprises (MSME) in Indonesia

  • PURNAMASARI, Pupung;PRAMONO, Irena Paramita;HARYATININGSIH, Ria;ISMAIL, Shahifol Arbi;SHAFIE, Rohami
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권10호
    • /
    • pp.981-988
    • /
    • 2020
  • Seeing the existence of MSME needs that have still not been met although this sector is undeniably important in Indonesian economy, changes in community behaviour and the intensity of the use of technology in the community, financial technology (fintech) has a lot of potentials to become a part of the solution of the problem commonly faced by MSMEs. Therefore this research needs to be done to observe the potential of fintech in integrating MSMEs in terms of the application of technology and knowledge from the community related to fintech. By using Technology Acceptance Model, this research tries to understand the determinant factors of the fintech application used by MSME. Based on the research framework and model, path analysis method used in this research. This research uses primary data gathered by the questioner, which was distributed to MSME. From the analysis conducted, we can conclude that the external factors tested in this research could have an effect on the behaviour intention through perceived usefulness in MSME practice of financial technology. Large variation in MSME educational background, busineess age and size would become a challenge in promoting fintech application, therefore this finding suggests that fintech should be promoted by highlighting what benefits can be obtained by using fintech application.

Anti-ds DNA 항체 검사 시 Lipemic 검체의 영향에 관한 보고 (Report on the Effects Lipemic Specimen in Anti-ds DNA Antibody Test)

  • 천준홍;김외정;김성호;문형호;유선희
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.153-157
    • /
    • 2014
  • Anti double-stranded DNA (Anti-ds DNA)항체의 검출은 SLE의 진단에 중요하며 American College of Rheumatologists의 SLE 진단기준에 포함되어 있다. 또한 SLE 질병의 활성도와 Anti-ds DNA 항체 수준의 상관성이 보고되어 있으며 Anti-ds DNA 항체 정량검사는 SLE의 치료 전, 후 추적에 매우 유용하다. Anti-ds DNA 항체의 검출을 위한 검사 방법으로 방사면역측정법(radioimmunoassay, RIA)을 이용한 Farr assay, Crithidia luciliae를 이용한 면역형광 측정법(immunofluorescence Test, CLIFT), 효소면역측정법(enzyme-linked immunosorbent assay, ELISA), 화학발광면역 측정법(chemiluminescence immunoassay, CLIA)이 있다. 본원에서 방사면역측정법(radioimmunoassay, RIA)으로 Anti-ds DNA 항체 검사 과정에서 lipemic한 검체의 경우 침전물의 형성이 원활하지 않거나 침전물도 같이 흡입되는 상황이 발생 하였고, 이러한 문제점을 해결하기 위해 lipemic 검체가 분석 결과에 미치는 영향 정도를 평가하였다. 2012년 9월부터 2013년 2월까지 Anti-ds DNA 항체 검사가 의뢰된 검체 중 lipemic한 검체(n=81)를 선택하여 마이크로 원심분리기로 전처리(고속 원심분리: 14,000 rpm 5 mins)한 후 동시에 Anti-ds DNA 항체 검사(Anti-ds DNA kit, Trinity Biotech, Ireland)를 시행하였다. 실험군 1 (lipemic 검체의 Anti-ds DNA 항체 농도 ${\leq}7IU/mL$)에서 y=0.3636x+4.7322, $R^2=0.0238$, Pearson 상관계수는 0.154, paired t-test (P=0.003), Difference (%) mean 65.7의 결과를 얻었으며 통계적으로 유의한 차이를 보였다. 그러나 실험군 2 (lipemic 검체의 Anti-ds DNA 항체 농도 ${\geq}8IU/mL$)에서 y=0.9837x+0.2982, $R^2=0.994$, Pearson 상관계수는 0.997, paired t-test (P=0.181), Difference (%) mean -5.53을 보였고 통계적으로 유의한 차이가 없음을 확인할 수 있었다. 임상에서 SLE (systemic lupus erythematosus)의 진단에 중요한 역할을 하는 Anti-ds DNA 항체 검사는 lipemic 검체의 영향을 배제하기 위해서 반드시 전처리(고속 원심분리: 14,000 rpm 5 mins) 과정을 통해 혈청 내 지질 성분을 제거한 후 검사를 시행하여야 한다.

  • PDF