• 제목/요약/키워드: Micro-Post

검색결과 324건 처리시간 0.023초

miR-153 Silencing Induces Apoptosis in the MDA-MB-231 Breast Cancer Cell Line

  • Anaya-Ruiz, Maricruz;Cebada, Jorge;Delgado-Lopez, Guadalupe;Sanchez-Vazquez, Maria Luisa;Perez-Santos, Jose Luis Martin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권5호
    • /
    • pp.2983-2986
    • /
    • 2013
  • MicroRNAs (miRNAs) are small, non-coding RNAs (18-25 nucleotides) that post-transcriptionally modulate gene expression by negatively regulating the stability or translational efficiency of their target mRNAs. In this context, the present study aimed to evaluate the in vitro effects of miR-153 inhibition in the breast carcinoma cell line MDA-MB-231. Forty-eight hours after MDA-MB-231 cells were transfected with the miR-153 inhibitor, an MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was utilized to determine the effects of miR-153 on cell viability. Flow cytometry analysis and assessment of caspase 3/7 activity were adopted to determine whether miR-153 affects the proliferation rates and apoptosis levels of MDA-MB-231 cells. Our results showed that silencing of miR-153 significantly inhibited growth when compared to controls at 48 hours, reducing proliferation by 37.6%, and inducing apoptosis. Further studies are necessary to corroborate our findings and examine the potential use of this microRNA in future diagnostic and therapeutic interventions.

miR-27a as an Oncogenic microRNA of Hepatitis B Virus-related Hepatocellular Carcinoma

  • Wu, Xin-Jun;Li, Yan;Liu, Dong;Zhao, Lun-De;Bai, Bin;Xue, Ming-Hui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권2호
    • /
    • pp.885-889
    • /
    • 2013
  • microRNAs (miRNAs) are small non-coding RNAs that regulate gene expression through post-transcriptional interactions with mRNA. miRNAs have recently emerged as key regulators of various cancers. Although miR-27a has been implicated in several other cancers, its role in hepatitis B virus-related hepatocellular carcinoma (HCC) is unknown. In this study, we showed miR-27a to be frequently up-regulated in HCC tissues and HCC cell lines (HepG2 and Huh7). Overexpression of miR-27a enhanced cell proliferation, promoted migration and invasion, and activated cell cycling in HepG2 and Huh7 cells. In summary, our results suggest that up-regulation of miR-27a may play an oncogenic role in the development of HCC and might thus be a new therapeutic target in HCC patients.

Al-Fe 레이저 오버레이층 경계면에서의 금속간화합물 거동 (Intermetallic Compounds Behavior at Laser Overlay Interface of Aluminum and Fe-based Powder)

  • 강남현;유연곤;이창우;김정한
    • Journal of Welding and Joining
    • /
    • 제25권3호
    • /
    • pp.51-56
    • /
    • 2007
  • A $CO_2$ laser overlay was conducted by using a Fe-based powder on the AC2B aluminum substrate. Cracks and intermetallic compounds (IMC) were observed inconsistently along the interface between the overlay and post-molten layer. A scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) detected some Fe-rich IMC ($Fe_3Al$, FeAl) as well as the brittle Al-rich IMC ($Fe_2Al_5,\;FeAl_3$). Micro vickers hardness proved the formation of Al-rich IMC ($FeAl_3$) along the interface by showing HV0.1 $800{\sim}900$. Furthermore, nano indentation was successfully applied to investigate the behavior of IMC more precisely than the micro vickers hardness.

The effect of different confluence confirmation strategies on the obturation of Vertucci type II canal: micro-CT analysis

  • Seungjae Do ;Min-Seock Seo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.12.1-12.9
    • /
    • 2021
  • Objectives: The present study aims to compare the obturation quality of 2 confluence confirmation techniques in artificial maxillary first premolars showing Vertucci type II root canal configuration. Materials and Methods: Thirty artificial maxillary premolars having Vertucci type II root canal configuration were made. They were divided into 3 groups according to the confluence confirmation technique as follows. Gutta-percha indentation (GPI) group (confluence confirmation using a gutta-percha cone and a K file); electronic apex locator (EAL) group (confluence confirmation using K files and EAL); and no confluence detection (NCD) group. In the GPI group and the EAL group, shaping and obturation were performed with the modified working length (WL). In the NCD group, shaping was performed without WL adjustment and obturation was carried out with an adjusted master cone. Micro-computed tomography was used before preparation and after obturation to calculate the percentage of gutta-percha occupied volume (%GPv) and the volume increase in the apical 4 mm. Data were analyzed using 1-way analysis of variance and post hoc Tukey's test. Results: Statistically significant difference was not found in terms of the %GPv from the apex to apical 4 mm. However, the NCD group showed a statistically significant volume increase compared with the EAL group (p < 0.05). Conclusions: In terms of gutta-percha occupied volume, no significant difference was observed among the 3 groups. Confluence confirmation using an EAL in teeth with Vertucci type II configuration showed less volume increase during canal shaping compared with no confluence confirmation.

Influence of reconstruction parameters of micro-computed tomography on the analysis of bone mineral density

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Brasil, Danieli Moura;Madlum, Daniela Verardi;Haiter-Neto, Francisco;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.153-159
    • /
    • 2020
  • Purpose: This study was conducted evaluate the influence of reconstruction parameters of micro-computed tomography (micro-CT) images on bone mineral density (BMD) analyses. Materials and Methods: The sample consisted of micro-CT images of the maxillae of 5 Wistar rats, acquired using a SkyScan 1174 unit (Bruker, Kontich, Belgium). Each acquisition was reconstructed following the manufacturer's recommendations(standard protocol; SP) for the application of artifact correction tools(beam hardening correction [BHC], 45%; smoothing filter, degree 2; and ring artifact correction [RAC], level 5). Additionally, images were reconstructed with 36 protocols combining different settings of artifact correction tools (P0 to P35). BMD analysis was performed for each reconstructed image. The BMD values obtained for each protocol were compared to those obtained using the SP through repeated-measures analysis of variance with the Dunnett post hoc test(α=0.05). Results: The BMD values obtained from all protocols that used a BHC of 45% did not significantly differ from those obtained using the SP (P>0.05). The other protocols all yielded significantly different BMD values from the SP(P<0.05). The smoothing and RAC tools did not affect BMD values. Conclusion: BMD values measured on micro-CT images were influenced by the BHC level. Higher levels of BHC induced higher values of BMD.

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.

Retreatability of two endodontic sealers, EndoSequence BC Sealer and AH Plus: a micro-computed tomographic comparison

  • Oltra, Enrique;Cox, Timothy C.;LaCourse, Matthew R.;Johnson, James D.;Paranjpe, Avina
    • Restorative Dentistry and Endodontics
    • /
    • 제42권1호
    • /
    • pp.19-26
    • /
    • 2017
  • Objectives: Recently, bioceramic sealers like EndoSequence BC Sealer (BC Sealer) have been introduced and are being used in endodontic practice. However, this sealer has limited research related to its retreatability. Hence, the aim of this study was to evaluate the retreatability of two sealers, BC Sealer as compared with AH Plus using micro-computed tomographic (micro-CT) analysis. Materials and Methods: Fifty-six extracted human maxillary incisors were instrumented and randomly divided into 4 groups of 14 teeth: 1A, gutta-percha, AH Plus retreated with chloroform; 1B, gutta-percha, AH Plus retreated without chloroform; 2A, gutta-percha, EndoSequence BC Sealer retreated with chloroform; 2B, gutta-percha, EndoSequence BC Sealer retreated without chloroform. Micro-CT scans were taken before and after obturation and retreatment and analyzed for the volume of residual material. The specimens were longitudinally sectioned and digitized images were taken with the dental operating microscope. Data was analyzed using an ANOVA and a post-hoc Tukey test. Fisher exact tests were performed to analyze the ability to regain patency. Results: There was significantly less residual root canal filling material in the AH Plus groups retreated with chloroform as compared to the others. The BC Sealer samples retreated with chloroform had better results than those retreated without chloroform. Furthermore, patency could be re-established in only 14% of teeth in the BC Sealer without chloroform group. Conclusion: The results of this study demonstrate that the BC Sealer group had significantly more residual filling material than the AH Plus group regardless of whether or not both sealers were retreated with chloroform.

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.

마이크로머시닝 기술을 이용한 새로운 형태의 고주파 저손실 Microstrip 전송선의 제작 (Fabrication of novel micromachined microstrip transmission line for millimeter wave applications)

  • 이한신;김성찬;임병옥;신동훈;김순구;박현창;이진구
    • 대한전자공학회논문지SD
    • /
    • 제41권8호
    • /
    • pp.37-44
    • /
    • 2004
  • 본 논문에서는 RF 부품 수동소자 중 가장 기본적인 요소가 되는 전송선로를 DAML(Dtelectric-supported Airbridge Microstrip Line) 형태의 새로운 구조로 제안하였으며, DAMS(Micro Electro Mechanical System) 기술 중 표면 마이크로머싱닝(surface micromachining) 기법을 이용하여 구현하였다. 제안된 구조는 마이크로스트립 라인(microstrip line)의 응용 형태로서 기존의 신호선(signal line)과 ground 사이에 유전체 지지대(dielectric post)를 사용하였고, 신호선을 공중으로 띄우면서 넓은 범위의 임피던스에서 유전체 손실(dielectric loss)을 최소화하였다. 본 논문에서 제작된 전송선로는 10 ㎛의 신호선의 높이와 10 ㎛ × 10 ㎛의 지지대(Post) 면적과 9 ㎛의 지지대(post)의 높이와 5 mm의 길이로 제작되었다. 50 GHz에서 일반적인 마이크로스티립(microstrip) 전송선의 손실이 약 7.5 dB/cm 이상 되는 것과 비교하여 본 논문에서 제안한 구조에서는 50 GHz에서 전송선의 손실이 약 1.1 dB/cm가 되는 것을 얻었다.

다이아몬드 와이어에 의해 절단된 다결정 실리콘 태양전지의 나노텍스쳐링 및 후속 식각 연구 (Nanotexturing and Post-Etching for Diamond Wire Sawn Multicrystalline Silicon Solar Cell)

  • 김명현;송재원;남윤호;김동형;유시영;문환균;유봉영;이정호
    • 한국표면공학회지
    • /
    • 제49권3호
    • /
    • pp.301-306
    • /
    • 2016
  • The effects of nanotexturing and post-etching on the reflection and quantum efficiency properties of diamond wire sawn (DWS) multicrystalline silicon (mc-Si) solar cell have been investigated. The chemical solutions, which are acidic etching solution (HF-$HNO_3$), metal assisted chemical etching (MAC etch) solutions ($AgNO_3$-HF-DI, HF-$H_2O_2$-DI) and post-etching solution (diluted KOH at $80^{\circ}C$), were used for micro- and nano-texturing at the surface of diamond wire sawn (DWS) mc-Si wafer. Experiments were performed with various post-etching time conditions in order to determine the optimized etching condition for solar cell. The reflectance of mc-Si wafer texturing with acidic etching solution showed a very high reflectance value of about 30% (w/o anti-reflection coating), which indicates the insufficient light absorption for solar cell. The formation of nano-texture on the surface of mc-Si contributed to the enhancement of light absorption. Also, post-etching time condition of 240 s was found adequate to the nano-texturing of mc-Si due to its high external quantum efficiency of about 30% at short wavelengths and high short circuit current density ($J_{sc}$) of $35.4mA/cm^2$.