• Title/Summary/Keyword: Micro-Doppler Effect

Search Result 6, Processing Time 0.016 seconds

Modeling Method of Receiving Radar Signals from Warhead and Decoy with Micro-Motion (미세운동을 가지는 탄두 및 기만체의 새로운 레이다 수신신호 모델링 방법)

  • Choi, In-Oh;Park, Sang-Hong;Kang, Ki-Bong;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.3
    • /
    • pp.243-251
    • /
    • 2019
  • Recently, several studies were conducted on the micro-Doppler(MD) phenomenon to identify a warhead from decoys. Both, the warhead and decoy, can be modeled as various shapes and maneuver with their own micro-motion. Their MD phenomenon can be demonstrated by amplitude modulation and phase modulation. Most studies have utilized approximate solutions to express the amplitude modulation regardless of various warhead and decoy shapes. However, the exact solution of the amplitude modulation is required for more effective warhead identification. In this study, we proposed a new modeling method of receiving radar signals from warheads and decoys based on physical optics. The proposed solution was evaluated using an electromagnetic prediction technique and computer-aided design models.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.

Investigation of Proton Irradiated Effect on n, p type Silicon by Positron Annihilation Method (양전자 소멸 측정에 의한 n, p형 실리콘 구조 특성)

  • Lee, C.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.225-232
    • /
    • 2012
  • It is described that the proton beam induceds micro-size defects and electronic deep levels in n or p type single crystal silicon. Positron lifetime and Coincidence Doppler Broadening Positron Annihilation Spectroscopy were applied to study of characteristics of p type and n type silicon samples. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. The samples were exposed by 3.98 MeV proton beams ranging between 0 to ${\sim}10^{14}$ particles. The S-parameter values strongly depend on the irradiated proton beam, that indicated the defects generate more. Positron lifetime shows that positrons trapped in vacancies and lifetime ${\tau}_2$ increased according to proton irradiation.

The use of laser Doppler blood flow to assess the effect of acute administration of vitamin D on micro vascular endothelial function in people with diabetes

  • Petrofsky, Jerrold;Alshammari, Faris;Khowailed, Iman Akef;Lodha, Riya;Deshpande, Pooja;Rajaram, Praveen;Gaikwad, Mahendra;Vadera, Vidhi
    • Physical Therapy Rehabilitation Science
    • /
    • v.2 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • Objective: To assess the effect of vitamin D administration on the skin blood flow response to occlusion and heat. Design: Cross-sectional study. Methods: Twenty age matched subjects; 10 who had diabetes and 10 who were controls were administered 4,000 IU of vitamin D3 for 3 weeks at breakfast. The function of the endothelial cells was evaluated in 2 ways; first, the response to 4 minutes of vascular occlusion of the skin was measured with a laser Doppler flow meter. Second, the skin blood flow response to local heat at 42 degrees C for 6 minutes was examined. Results: The results of the experiments showed that the blood flow response to heat was reduced after 3 weeks administration of vitamin D in the subjects with diabetes and in the control subjects (p<0.05). The response to occlusion was not significantly different within each group before and after vitamin D administration, but the group with diabetes had a significantly lower blood flow response to occlusion than did the controls (p<0.05). Conclusions: Acute doses of vitamin D may impair nitric oxide production and reduce blood flow to tissue during stressors in people with diabetes.

The Effect of Intake Port Configurations on the Turbulence Characteristics During Compression Stroke in a Motored Engine (흡입포트형상에 따른 모터링엔진내 압축과정 난류특성 연구)

  • 강건용;이진욱;정석용;백제현
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.920-932
    • /
    • 1994
  • The combustion phenomena of a reciprocating engine is one of the most important processes affecting performance and emissions. One effective way to improve the engine combustion is to control the motion of the charge inside a cylinder by means of optimum induction system design, because the flame speed is mainly determined by the turbulence at compression(TDC) process in S.I. engine. It is believed that the tumble and swirl motion generated during intake breaks down into small-scale turbulence in the compression stroke of the cycle. However, the exact nature of their relationship is not well known. This paper describes cycle resolved LDV measurement of turbulent flow inside the cylinder of a 4-valve engine under motoring(non-firing) conditions, and studies the effect of intake port configurations on the turbulence characteristics using following parameters ; Eulerian temporal autocorrelation coefficient, turbulence energy spectral density function, Taylor micro time scale, integral time scale, and integral length scale.

Angiogenic factor-enriched platelet-rich plasma enhances in vivo bone formation around alloplastic graft material

  • Kim, Eun-Seok;Kim, Jae-Jin;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • Although most researchers agree that platelet-rich plasma (PRP) is a good source of autogenous growth factors, its effect on bone regeneration is still controversial. The purpose of this study was to evaluate whether increasing angiogenic factors in the human PRP to enhance new bone formation through rapid angiogenesis. MATERIAL AND METHODS. In vitro, the human platelets were activated with application of shear stress, $20\;{\mu}g/ml$ collagen, 2 mM $CaCl_2$ and 10U thrombin/$1\;{\times}\;10^9$ platelets. Level of vascular endothelial growth factor (VEGF) and platelet microparticle (PMP) in the activated platelets were checked. In the animal study, human angiogenic factors-enriched PRP was tested in 28 athymic rat's cranial critical bone defects with $\beta$-TCP. Angiogenesis and osteogenesis were evaluated by laser Doppler perfusion imaging, histology, dual energy X-ray densinometry, and micro-computed tomography. RESULTS. In vitro, this human angiogenic factors-enriched PRP resulted in better cellular proliferation and osteogenic differentiation. In vivo, increasing angiogenic potential of the PRP showed significantly higher blood perfusion around the defect and enhanced new bone formation around acellular bone graft material. CONCLUSION. Angiogenic factor-enriched PRP leads to faster and more extensive new bone formation in the critical size bone defect. The results implicate that rapid angiogenesis in the initial healing period by PRP could be supposed as a way to overcome short term effect of the rapid angiogenesis.