• Title/Summary/Keyword: Micro flow

Search Result 1,326, Processing Time 0.047 seconds

Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 - (공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Characteristics of Micro-Particle Separation according to HRT Changes (HRT 변화에 따른 미세입자 분리 특성)

  • Ahn, Kwangho;Ahn, Jaehwan;Kim, I-Tae;Kim, Seoggu;Kang, Sungwon;Park, Eunzoo;Lee, Youngsup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.937-942
    • /
    • 2013
  • Fluid generated within the sonic or ultrasonic waves are reflected by the wall, while the opposite direction forming a predetermined sound wave to the acoustic standing wave is referred to. In this study, the frequency of 1.0 MHz and 2.0 MHz acoustic standing wave generation module is installed in a continuous particle separation device, the laminar flow of influent, taking into account the hydraulic retention time (HRT) in accordance with changes in particle separation characteristics investigated. Operation of a standing wave in the particle separation device about $1.3{\sim}2.8^{\circ}C$ temperature is increased, but did not significantly affect the formation of standing waves. During operation, the HRT 1 hr frequency 1.0 MHz 2 hr, 4 hr longer as the particle separation efficiency (turbidity) were 64.1%, 70.0%, 74.3% and, 2.0 MHz has 58.0%, respectively, depending on HRT, 61.8%, 70.7% in the respectively. That is, the same frequency, the HRT treatment efficiency is 10% or more, depending on differences in generation and, 1.0 MHz frequency, 2 hr, 2.0 MHz 4 hr at about 70% or more of the processing efficiency can be maintained. Frequency of 1.0 MHz and 2.0 MHz operation at the same time, as a result, HRT 1 hr, 2 hr, 4 hr particle separation efficiency of 63.8%, respectively, 70.6%, 77.6%, rather than the generation of standing waves appear continuous HRT is affecting a lot of particles to separate could know.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.

Recent Progress in Air Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 (공기조화, 냉동 분야의 최근 연구 동향: 2006년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.6
    • /
    • pp.427-446
    • /
    • 2008
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2006 has been accomplished. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro heat exchanger and siphon cooling device using nano-fluid. Traditional CFD and flow visualization methods were still popular and widely used in research and development. Studies about diffusers and compressors were performed in fluid machinery. Characteristics of flow and heat transfer and piping optimization were studied in piping systems. (2) The papers on heat transfer have been categorized into heat transfer characteristics, heat exchangers, heat pipes, and two-phase heat transfer. The topics on heat transfer characteristics in general include thermal transport in a cryo-chamber, a LCD panel, a dryer, and heat generating electronics. Heat exchangers investigated include pin-tube type, plate type, ventilation air-to-air type, and heat transfer enhancing tubes. The research on a reversible loop heat pipe, the influence of NCG charging mass on heat transport capacity, and the chilling start-up characteristics in a heat pipe were reported. In two-phase heat transfer area, the studies on frost growth, ice slurry formation and liquid spray cooling were presented. The studies on the boiling of R-290 and the application of carbon nanotubes to enhance boiling were noticeable in this research area. (3) Many studies on refrigeration and air conditioning systems were presented on the practical issues of the performance and reliability enhancement. The air conditioning system with multi indoor units caught attention in several research works. The issues on the refrigerant charge and the control algorithm were treated. The systems with alternative refrigerants were also studied. Carbon dioxide, hydrocarbons and their mixtures were considered and the heat transfer correlations were proposed. (4) Due to high oil prices, energy consumption have been attentioned in mechanical building systems. Research works have been reviewed in this field by grouping into the research on heat and cold sources, air conditioning and cleaning research, ventilation and fire research including tunnel ventilation, and piping system research. The papers involve the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies on indoor air quality took a great portion in the field of building environments. Various other subjects such as indoor thermal comfort were also investigated through computer simulation, case study, and field experiment. Studies on energy include not only optimization study and economic analysis of building equipments but also usability of renewable energy in geothermal and solar systems.

The Effect of CO2 Fixation for Microalgae based on CO2 Concentration and Flow Rate (이산화탄소 농도 및 유속에 따른 하천 내 미세조류의 이산화탄소 고정 효과)

  • Park, Hyomin;Lee, Sangdon
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.363-369
    • /
    • 2018
  • One of the recent environmental problems is climate change due to the increase of atmospheric $CO_2$, which causes ecological changes and various environmental problems. Therefore, various studies are being carried out to reduce $CO_2$ in the world in order to solve various environmental problems caused by increase of $CO_2$. The $CO_2$ reduction using microalgae is an environmentally friendly method by using photosynthesis reaction of microalgae. However, most studies using single species. There is no study on the $CO_2$ fixing efficiency of microalgae in natural rivers. Therefore, this study was to identify the microalgae in the Sum river and to analyze the growth characteristics of microalgae in the river to obtain optimal culture conditions. And the changes of biomass and chlorophyll-a of microalgae were analyzed according to $CO_2$ concentration and injection rate. The purpose of this study was to investigate the fixing efficiency of carbon dioxide in microalgae in natural rivers. Six kinds of dominant species were observed as a result of the identification of microalgae in Sum river(Ankistrodesmus falcatus, Scenedesmus intermedius, Selenodictyum sp., Xanthidium apiculatum var. laeve, Cosmarium pseudoquinarium, Dictyosphaerium pulchellum). All of these species were green algae. Biomass and chlorophyll-a increased with the increase of $CO_2$ concentration and biomass and chlorophyll-a increased faster flow rate at the same $CO_2$ concentration. Also, the quantity of $CO_2$ fixation on the microalgae tended to be higher when the flow rate of injected gas was faster. This study can be referred as being significant in the micro-algae in river. In addition, the optimal conditions for $CO_2$ fixation of microalgae in rivers and the quantification of the quantity of $CO_2$ fixation from microalgae in rivers can be used as basic data for future policy of $CO_2$ reduction.

Characteristic Evaluation of Optically Stimulated Luminescent Dosimeter (OSLD) for Dosimetry (광유도발광선량계(Optically Stimulated Luminescent Dosimeter)의 선량 특성에 관한 고찰)

  • Kim, Jeong-Mi;Jeon, Su-Dong;Back, Geum-Mun;Jo, Young-Pil;Yun, Hwa-Ryong;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.123-129
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate dosimetric characteristics of Optically stimulated luminescent dosimeters (OSLD) for dosimetry Materials and Methods: InLight/OSL $NanoDot^{TM}$ dosimeters was used including $Inlight^{TM}MicroStar$ Reader, Solid Water Phantom, and Linear accelerator ($TRYLOGY^{(R)}$) OSLDs were placed at a Dmax in a solid water phantom and were irradiated with 100 cGy of 6 MV X-rays. Most irradiations were carried out using an SSD set up 100 cm, $10{\times}10\;cm^2$ field and 300 MU/min. The time dependence were measured at 10 minute intervals. The dose dependence were measured from 50 cGy to 600 cGy. The energy dependence was measured for nominal photon beam energies of 6, 15 MV and electron beam energies of 4-20 MeV. The dose rate dependence were also measured for dose rates of 100-1,000 MU/min. Finally, the PDD was measured by OSLDs and Ion-chamber. Results: The reproducibility of OSLD according to the Time flow was evaluated within ${\pm}2.5%$. The result of Linearity of OSLD, the dose was increased linearly up to about the 300 cGy and increased supralinearly above the 300 cGy. Energy and dose rate dependence of the response of OSL detectors were evaluated within ${\pm}2%$ and ${\pm}3%$. $PDD_{10}$ and PDD20 which were measured by OSLD was 66.7%, 38.4% and $PDD_{10}$ and $PDD_{20}$ which were measured by Ion-chamber was 66.6%, 38.3% Conclusion: As a result of analyzing characteration of OSLD, OSLD was evaluated within ${\pm}3%$ according to the change of the time, enregy and dose rate. The $PDD_{10}$ and $PDD_{20}$ are measured by OSLD and ion-chamber were evaluated within 0.3%. The OSL response is linear with a dose in the range 50~300 cGy. It was possible to repeat measurement many times and progress of the measurement of reading is easy. So the stability of the system and linear dose response relationship make it a good for dosimetry.

  • PDF

A Study on the Prediction of Residual Probability of Fine Dust in Complex Urban Area (복잡한 도심에서의 유입된 미세먼지 잔류 가능성 예보 연구)

  • Park, Sung Ju;Seo, You Jin;Kim, Dong Wook;Choi, Hyun Jeong
    • Journal of the Korean earth science society
    • /
    • v.41 no.2
    • /
    • pp.111-128
    • /
    • 2020
  • This study presents a possibility of intensification of fine dust mass concentration due to the complex urban structure using data mining technique and clustering analysis. The data mining technique showed no significant correlation between fine dust concentration and regional-use public urban data over Seoul. However, clustering analysis based on nationwide-use public data showed that building heights (floors) have a strong correlation particularly with PM10. The modeling analyses using the single canopy model and the micro-atmospheric modeling program (ENVI-Met. 4) conducted that the controlled atmospheric convection in urban area leaded to the congested flow pattern depending on the building along the distribution and height. The complex structure of urban building controls convective activity resulted in stagnation condition and fine dust increase near the surface. Consequently, the residual effect through the changes in the thermal environment caused by the shape and structure of the urban buildings must be considered in the fine dust distribution. It is notable that the atmospheric congestion may be misidentified as an important implications for providing information about the residual probability of fine dust mass concentration in the complex urban area.

Analysis of CFD for Flow Discharge in Hard Micro-path of Drip Hose (점적 호스의 경질 미로 유량 변화에 대한 CFD 해석)

  • Kim, J.H.;Woo, M.H.;Kim, S.S.;Kim, D.E.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.58-58
    • /
    • 2017
  • 점적 호스의 원통형 미로 구조물내의 유동특성을 분석하기 위해 금속판에 동일한 구조의 미로가 가공된 시험부를 활용하여 압력과 유량의 변화에 대한 실험을 CFD 해석하였다. 해석은 미로의 길이에 따른 유량 특성을 정밀하게 분석하기 위해 전체 미로에 구간별 총 8개의 배출구를 배치하고 밸브 조절을 통해 구간별 압력에 따른 유량을 측정함으로서 실험에 의한 압력과 유량의 관계를 검증하고 새로운 경질 미로를 설계하는데 응용하고자 한다. 경질 미로의 이론적인 해석에서 정밀도가 실험을 대신할 가능성이 있는지에 관심을 두었다. 점적관수의 경질 미로는 디자인을 달리함으로써 성능이 높고 미세한 스케일이 침착되지 않는 고성능의 점적관수 장치의 개발이 가능할 것으로 판단하였다. 미로 입구의 공급 유체 압력(Gauge pressure)을 0.5, 1.5, 2.5, 3.0 bar로 나누어 공급하였으며, 8개의 구간별 유출되는 유량은 전자저울에서 측정하였다. 향후 최적 미로의 새로운 설계를 위해 미로구조 전체를 CFD 해석하였고 그 결과를 실험치와 비교 분석하였다. 또한 경질 미로내 각 구간별 세부적인 유동구조를 분석하였고 해석결과와 실험결과를 통해 향후 새로운 경질 구조의 개발이 가능 할 것으로 판단되었다. 경질 미로의 입구압력에 따른 미로의 길이 #1과 #2에 대한 CFD 분석에서는 전체적으로 경질 미로에 압력이 증가할수록 미로의 유체 속도가 증가됨을 알 수 있었으며 이것은 #2에서도 거의 같은 양상을 나타내었다. 미로 통로에서는 와류로 인한 이물질의 멈춤 현상이 발생하지 않을 만큼 흐름이 원활함을 알 수 있었다. 미로의 길이 #3과 #4에 대한 CFD 분석과 미로의 길이 #5와 #6에 대한 CFD 분석에서는 압력이 증가하고 미로의 길이가 길어질수록 속도에도 영향을 미치고 있는 것으로 나타났으며 미로와 미로 사이의 넒은 통로에서는 유속이 크게 떨어지고 있음을 알 수 있었다. 따라서 이 부분에는 유체속의 이물질이 침착할 수 있는 가능성이 있으며 통로가 좁은 곳에서는 유속이 증가되는 것으로 나타났다. #7과 #8은 미로의 상하단으로 유출되는 부분의 차이이므로 실질적으로 해석의 결과는 차이가 없었다. 경질 미로에 대한 압력에 따른 미로의 길이별 유출량은 지수적인 반비례 현상을 나타내어 앞서 실험한 연구의 결과와 1~2% 오차 범위에서 잘 일치하였다. 따라서 점적 호스의 경질 미로에 대한 설계는 이론적인 해석을 통하여 새로운 디자인이 가능할 것으로 판단되었다. 경질 미로의 미로의 길이에 따른 CFD 분석의 결과는 실험적인 유출량의 값과 거의 일치하였다. 미로와 미로 사이의 넒은 통로에서는 유속이 크게 떨어져 이물질들이 침착될 가능성이 있었으며 실질적으로 넓게 설계하는 것이 유리하지 않을 것으로 판단되었다. 경질 미로에 대한 압력에 따른 미로의 길이별 유출량은 지수적으로 반비례 하였으며 점적 호스의 경질 미로에 대한 새로운 설계는 이론적인 해석을 통하여 가능할 것으로 판단되었다.

  • PDF