• 제목/요약/키워드: Micro cone

검색결과 71건 처리시간 0.021초

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

FBG센서를 이용한 콘 선단저항력의 온도영향 보상 (Temperature Compensation on the Cone Tip Resistance by Using FBG Temperature Transducer)

  • 김래현;이종섭;안신환;이우진
    • 한국지반공학회논문집
    • /
    • 제25권10호
    • /
    • pp.31-40
    • /
    • 2009
  • 전기저항식 변형율계를 이용한 콘 관입시험기는 온도 변화에 의해 선단저항력이 달라진다-본 연구에서는 FBG센서를 이용하여 직경 0.5mm의 온도센서와 직경 7mm의 마이크로콘을 제작하여 온도의 변화가 콘 선단저항력에 미치는 영향을 평가하고 이를 효과적으로 보상하고자 하였다-광섬유 마이크로콘과 온도센서는 콘의 구조, 센서 부착 위치 및 광섬유를 이용한 온도보상법 등을 고려하여 제작하였다-온도영향 시험결과, 전기저항식 변형율계의 콘 선단저항력은 온도에 의해 영향을 받으며 온도 차이가 클수록 오차도 증가하는 것으로 나타났다. 반면, FBG센서에서 측정된 콘 선단저항력은 FBG 온도센서를 이용하여 효과적으로 온도의 영향을 보상할 수 있었다. 또한 온도 보상을 실시한 전기저항식 변형율계의 콘 선단저항력은 심도에 따라 일정한 분포를 보였으며 관입과 동시에 온도의 영향이 보상되는 FBG센서의 결과와도 매우 유사한 것으로 나타났다. 본 연구를 통해 온도 변화가 선단저항력에 미치는 영향을 평가하였으며, FBG센서를 이용하여 효과적으로 온도 영향을 보상할 수 있음을 확인하였다.

Comparison of limited- and large-volume cone-beam computed tomography using a small voxel size for detecting isthmuses in mandibular molars

  • de Souza Tolentino, Elen;Andres Amoroso-Silva, Pablo;Alcalde, Murilo Priori;Yamashita, Fernanda Chiguti;Iwaki, Lilian Cristina Vessoni;Rubira-Bullen, Izabel Regina Fischer;Duarte, Marco Antonio Hungaro
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.27-34
    • /
    • 2021
  • Purpose: This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars. Materials and Methods: Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05). Results: The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (P>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat(P<0.05). Conclusion: Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

Accuracy verification of dental cone-beam computed tomography of mandibular incisor root canals and assessment of its morphology and aging-related changes

  • Katsuyuki Aoki;Masamitsu Serikawa;Takuya Harada;Akinobu Usami
    • Anatomy and Cell Biology
    • /
    • 제56권2호
    • /
    • pp.185-190
    • /
    • 2023
  • The root canal morphology undergoes aging-related changes, and relevant quantitative analyses have not yet been reported. We compared the cone beam computed tomography (CBCT) and micro-computed tomography (microCT) scans of extracted mandibular incisors to check the accuracy of morphological measurements. Thereafter, the root canal morphology and aging-related changes in the mandibular incisors of Japanese individuals were assessed using CBCT. Six extracted teeth were fixed in a phantom head and imaged using CBCT and micro-CT. The correlation between the findings of the two imaging modalities was examined. Further, CBCT reconstructed images of the mandibular incisors of 81 individuals were observed. Age-related changes of the root canals were compared between participants aged <30 years and those aged ≥30 years. The CBCT and micro-CT findings regarding the root canals of the extracted teeth coincided in 94.4% of the cases. Mandibular incisors exhibiting two root canals in either cross-section accounted for 9.9% of central incisors and 12.4% of lateral incisors. Mandibular central incisors with two root canals were observed in two (6.3%) individuals aged <30 years and six (12.2%) aged ≥30 years. Mandibular lateral incisors with two root canals were observed in one (3.1%) individual aged <30 years and nine (18.4%) aged ≥30 years. CBCT allows accurate evaluation of complex root canal morphologies and is useful for endodontic preoperative assessment. Mandibular incisors have more frequent occurrence of two root canals with aging.

마이크로 휜 표면의 분무냉각 열전달에 관한 실험적 연구 (Experimental Study on Spray Cooling Heat Transfer of Micro-Fins Surfaces)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제14권4호
    • /
    • pp.178-183
    • /
    • 2009
  • Spray cooling heat transfer was experimentally investigated for water sprays impacting on mico-fins structured surfaces in the single phase and nucleate boiling regions. The heat transfer surfaces consist of cubic fins and triangular grooved fins. The spray produced using full cone spray nozzles, and experiments were made under the test condition of $Q=4.92{\times}10^{-6}{\sim}15.83{\times}10^{-6}\;m^3/s$, $T_f=35{\sim}55^{\circ}C$. From the experimental results, it was found that cubic fins surface had the largest heat flux enhancement relative to the smooth surface.

  • PDF

Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study

  • Tayman, Mahmure Ayse;Kamburoglu, Kivanc;Ocak, Mert;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.171-179
    • /
    • 2022
  • Purpose: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. Materials and Methods: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075mm(high: HI) and 0.2mm(standard: Std), while microCT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor(TbPf), and structure model index (SMI). Results: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different(P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods(P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. Conclusion: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.

배기노즐 형상변화에 따른 마이크로 터보제트 엔진의 성능 및 적외선신호 실험연구 (Experimental Study of a Micro Turbo Jet Engine Performance and IR Signal with Nozzle Configuration)

  • 박규상;김선미;최성만;명노신;김원철
    • 한국추진공학회지
    • /
    • 제20권5호
    • /
    • pp.1-8
    • /
    • 2016
  • 배기노즐 형상변화에 따른 엔진성능특성 변화와 그에 따른 적외선 신호특성을 이해하기 위하여 마이크로 터보제트 엔진을 이용한 성능특성 및 적외선 신호 측정 연구를 수행하였다. 엔진 배기노즐은 원형노즐과 가로세로비가 서로 다른 5개의 사각형 노즐을 제작하여 실험을 진행하였다. 엔진의 추력 및 연료소모율은 배기노즐 형상에 따라 큰 차이를 나타내지는 않았다. 그러나 배기가스에서 방출되는 적외선 신호의 경우 가로세로비가 큰 사각형 노즐에서 적외선 신호가 점차 감소하는 경향을 확인하였다.

The effect of different confluence confirmation strategies on the obturation of Vertucci type II canal: micro-CT analysis

  • Seungjae Do ;Min-Seock Seo
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.12.1-12.9
    • /
    • 2021
  • Objectives: The present study aims to compare the obturation quality of 2 confluence confirmation techniques in artificial maxillary first premolars showing Vertucci type II root canal configuration. Materials and Methods: Thirty artificial maxillary premolars having Vertucci type II root canal configuration were made. They were divided into 3 groups according to the confluence confirmation technique as follows. Gutta-percha indentation (GPI) group (confluence confirmation using a gutta-percha cone and a K file); electronic apex locator (EAL) group (confluence confirmation using K files and EAL); and no confluence detection (NCD) group. In the GPI group and the EAL group, shaping and obturation were performed with the modified working length (WL). In the NCD group, shaping was performed without WL adjustment and obturation was carried out with an adjusted master cone. Micro-computed tomography was used before preparation and after obturation to calculate the percentage of gutta-percha occupied volume (%GPv) and the volume increase in the apical 4 mm. Data were analyzed using 1-way analysis of variance and post hoc Tukey's test. Results: Statistically significant difference was not found in terms of the %GPv from the apex to apical 4 mm. However, the NCD group showed a statistically significant volume increase compared with the EAL group (p < 0.05). Conclusions: In terms of gutta-percha occupied volume, no significant difference was observed among the 3 groups. Confluence confirmation using an EAL in teeth with Vertucci type II configuration showed less volume increase during canal shaping compared with no confluence confirmation.

용액 미립화공정 기반의 마이크로 스텐실 프린팅에 관한 연구 (A Study of Micro Stencil Printing based on Solution Atomization Process)

  • 당현우;김형찬;고정범;양영진;양봉수;최경현;도양회
    • 한국정밀공학회지
    • /
    • 제31권6호
    • /
    • pp.483-489
    • /
    • 2014
  • In this study, experiments were conducted for micro pattern printing to combine solution atomization process and stencil printing based on electrospray deposition. The stencil mask fabricated by etching the photosensitive glass placed below 0.3 mm distance to substrate has 100 um line width. The process parameters of electrospray deposition system for the atomization of the solution are applied voltage and supply flow rate of the solution. Meniscus angle of cone-jet was optimized by varying the supply flow rate from 0.3 ml/hr to 0.7 ml/hr. Voltage condition was verified having symmetric cone-jet angle and no pulsation at 8.5 kV applied voltage. In addition, a number of micro patterns are printed using a single 1 step process by solution atomization process. Variable line width of approximate 100 um was confirmed by changing conditions of solution atomization regardless of the pattern size of stencil mask.

A micro-computed tomographic evaluation of root canal filling with a single gutta-percha cone and calcium silicate sealer

  • Kim, Jong Cheon;Moe, Maung Maung Kyaw;Kim, Sung Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.18.1-18.9
    • /
    • 2020
  • Objectives: The purpose of this study was to evaluate the void of root canal filling over time when a calcium silicate sealer was used in the single gutta-percha cone technique. Materials and Methods: Twenty-four J-shaped simulated root canals and twenty-four palatal root canals from extracted human maxillary molars were instrumented with ProFile Ni-Ti rotary instruments up to size 35/0.06 or size 40/0.06, respectively. Half of the canals were filled with Endoseal MTA and the other half were with AH Plus Jet using the single gutta-percha cone technique. Immediately after and 4 weeks after the root canal filling, the samples were scanned using micro-computed tomography at a resolution of 12.8 ㎛. The scanned images were reconstructed using the NRecon software and the void percentages were calculated using the CTan software, and statistically analyzed by 1-way analysis of variance, paired t-test and Tukey post hoc test. Results: After 4 weeks, there were no significant changes in the void percentages at all levels in both material groups (p > 0.05), except at the apical level of the AH Plus Jet group (p < 0.05) in the simulated root canal showing more void percentage compared to other groups. Immediately after filling the extracted human root canals, the Endoseal MTA group showed significantly less void percentage compared to the AH Plus Jet group (p < 0.05). Conclusions: Under the limitations of this study, the Endoseal MTA does not seem to reduce the voids over time.