• 제목/요약/키워드: Micro cone

검색결과 71건 처리시간 0.032초

다층지반 탐지를 위한 광섬유 마이크로콘의 개발 (Development of FBG Micro Cone Penetrometer for Layered Soil Detection)

  • 김래현;이우진;윤형구;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.341-348
    • /
    • 2009
  • Various types of micro cone penetrometers have been developed by using strain gages for the layered soil detection. Strain gages, however, are affected by several factors such as temperature, self heating and lead wire length. In this study, micro cone penetrometers with 3~7mm in diameter, are developed by using FBG sensor to overcome the defects of the strain gage, and compensate the effect of temperature during penetration. In order to verifiy the accuracy and reliability of the developed FBG cone, the cone penetration test is performed on the layered soil. The tip resistance of FBG snesor shows excellent sensitivity, and can detect the interface of the layered soils with higher resolution. In addition, the 3mm micro cone penetrometer which is impossible cone diameter by using strain gages presents much higher sensitivity than the 7mm cone penetrometer. This study suggests that FBG sensor is a useful sensor for manufaturing the ultra small sized cone, and effectively detects the interface of the layered soil.

  • PDF

초소형 마이크로콘 관입시험기의 개발 및 적용 (Development and Application of Ultra Small Micro-Cone Penetrometer)

  • 이종섭;신동현;윤형구;이우진
    • 한국지반공학회논문집
    • /
    • 제24권2호
    • /
    • pp.77-86
    • /
    • 2008
  • 흙의 교란영역과 측정값은 관입시험기의 크기에 영향을 받는다. 관입기의 크기가 작을수록 더 국부적인 값을 얻을 수 있다. 관입시험 시 흙의 교란을 최소화하면서 흙의 특성을 파악하기 위하여 극소형 마이크로콘(외경 5mm)을 설계 및 제작하였다. 선단저항력은 마이크로콘 선단부에 설치된 변형률계를 이용하여 측정하였다. 뿐만 아니라 선단 저항력으로부터 마찰저항력 성분을 효과적으로 제거하기 위하여 이중관 형식의 마찰 슬리브를 채택하였다. 설계 시 변형률계의 설치, 회로구성, 관입시스템, 관입속도, 측정률, 작동 온도, 그리고 calibration 과정이 고려되었다. 점토의 경계면, 점토-모래지반의 경계면을 마이크로콘을 적용함으로써 효과적으로 찾아 낼 수 있었다. 뿐만 아니라, 마이크로 콘과 직경 16mm의 미니어처 콘을 이용하여 측정한 선단저항력이 매우 유사하지만, 마이크로 콘의 해상도가 매우 높은 것으로 나타났다. 본 논문은 마이크로 콘이 매우 높은 해상도 그리고 주변지반의 변형을 최소화하면서 흙의 경계면을 효과적으로 감지할 수 있음을 보여준다.

Bacterial leakage and micro-computed tomography evaluation in round-shaped canals obturated with bioceramic cone and sealer using matched single cone technique

  • Yanpiset, Kallaya;Banomyong, Danuchit;Chotvorrarak, Kanet;Srisatjaluk, Ratchapin Laovanitch
    • Restorative Dentistry and Endodontics
    • /
    • 제43권3호
    • /
    • pp.30.1-30.12
    • /
    • 2018
  • Objectives: To evaluate sealing ability of root canals obturated with bioceramic-impregnated gutta percha cone (BCC) or gutta percha (GP), with bioceramic sealer (BCS) or AH Plus (AH; Dentsply-Maillefer), in roundly-prepared canals using matched single-cone technique, based on bacterial leakage test, and to analyze obturation quality using micro-computed tomography (CT) analysis. Materials and Methods: Ninety-two distobuccal roots of maxillary molars were prepared using nickel-titanium files to apical size 40/0.06. The roots were divided into 4 groups (n = 20) that were obturated with a master cone and sealer: GP/AH, BCC/AH, GP/BCS, and BCC/BCS. Bacterial leakage model using Enterococcus faecalis was used to evaluate sealing ability for 60-day period. Obturated samples from each group (n = 4) were analyzed using micro-CT. Results: All groups showed bacterial leakage at 20%-45% of samples with mean leakage times of 42-52 days. There were no significant differences in bacterial leakage among the groups. Micro-CT showed minimal gaps and voids in all groups at less than 1%. Conclusions: In roundly-prepared canals, the single cone obturation with BCC/BCS was comparable to GP/AH for bacterial leakage at 60 days.

유리의 미세구멍 가공시 출구 크랙 발생 방지 (Prevention of Exit Crack in Mirco-drilling of Soda-lime Glass)

  • 박병진;최영준;주종남
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.1052-1055
    • /
    • 2001
  • In micro-drilling of brittle materials including glass, cracks occur at the exit surface. In drilling glass, the main type of crack is cone crack. Cone crack is generated by thrust force acting at the bottom surface of the workpiece. Cone crack size could be reduced by changing cutting conditions, but cone crack still existed. Two methods were proposed to prevent crack formation and perfect hole shapes were obtained. One method is attaching two glass plates with water and the other method is constraining two glass plates. The proposed methods eliminated tensile stress acting on the exit surface of glass and prevented crack propagation.

  • PDF

CRPT를 이용한 연약지반 협재층 탐지 (Detection of thin-layered soil using CRPT in soft soil)

  • 윤형구;김준한;김래현;최용규;이종섭
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.117-125
    • /
    • 2008
  • The detection of thin-layered soil is important in soft soils to evaluate the soil behavior. The smaller diameter cone penetrometer have been commonly used to detect the layer with increasing sensitivity. The objective of this study is to detect the thin-layered soil using cone resistance and electrical resistance. The cone resistivity penetration test (CRPT) is developed to evaluate the cone tip resistance and electrical resistance at the tip. The CRPT is a micro-cone which has a $0.78cm^2$ in projected area. The application test is conducted in a laboratory large-scale consolidometer (calibration chamber). The kaolinite, sand and water are mixed to make the specimen at the liquid limit of 46% using a slurry mixer. It takes two months for the consolidation of the specimen. After consolidation, the CRPT test is carried out. Furthermore the standard CPT results are compared with the electrical resistance measured at the tip in the field. This study suggests that the CRPT may be a useful tool for detecting thin-layers in soft soils.

  • PDF

Non-Destructive Detection of Hertzian Contact Damage in Ceramics

  • Ahn, H.S.;Jahanmir, S.
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.114-121
    • /
    • 1995
  • An ultrasonic technique using normal-incident compressional waves was used to evaluate the surface and subsurface damage in ceramics produced by Hertzian indentation. Damage was produced by a blunt indenter (tungsten carbide ball) in glass-ceramic, green glass and silicon nitride. The damage was classified into two types; (1) Hertzian cone crack, in green glass and fine grain silicon nitride, and (2) distributed subsurface micro fractures, without surface damage, produced in glass ceramic. The ultrasonic technique was successful in detecting cone craks. The measurement results with the Hertzian cone cracks indicated that cracks perpendicular to the surface could be detected by the normal-incident compressional waws. Also shown is the capability of normal-incident compressional waves in detection distributed micro-sized cracks size of subsurface microfractures.

교류 구동형 박막 전계 발광 소자용 원추형 Si micro-tip 반사체 어래이의 제작 (Fabrication of Cone-shaped Si Micro-tip Reflector Array for Alternating Current Thin Film Electroluminescent Device Application)

  • 주병권;이윤희;오명환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권9호
    • /
    • pp.662-664
    • /
    • 1999
  • We fabricated AC-TFEL device having cone-shaped Si micro-tip reflector array based on the process which have been conventionally employed for the Si-tip field emitter array in FED system. As a result, the AC-TFEL device having a new geometrical structure could generate well concentrated visible white-light from 3600 reflectors/pixel under bipolar pulse excitation mode only by edge-emission mechanism.

  • PDF

Micro Reverse-pyramid Array를 이용한 일체형 Sheetless LCD Backlight의 광학적 특성 (Optical Characteristics of Sheetless LCD Backlight Using Micro Reverse-pyramid Array)

  • 전화준;임교성;곽진석;권진혁
    • 한국광학회지
    • /
    • 제23권3호
    • /
    • pp.119-123
    • /
    • 2012
  • LCD backlight unit (BLU)에서 도광판 상부에 micro reverse-pyramid array (MRPA) 또는 micro reverse-cone array (MRCA)을 설치함으로써 기존의 확산 시트와 프리즘 시트를 없애고 구조를 단순화하였으며, 광학적 시뮬레이션을 통하여 새로운 도광판의 최적 조건을 얻었다. MRPA와 MRCA의 측면각과 높이, 윗변의 반지름이나 윗변의 길이에 따라 휘도와 시야각의 변화를 구하였다. MRPA와 MRCA 구조물의 최적의 형상은 측면각이 각각 59도와 57도이었으며, 시야각은 68도와 64도이었다. 구조물의 높이는 큰 영향을 주지 않았다.

소 동물 촬영을 위한 Micro-CT의 개발 (Development of a Micro-CT System for Small Animal Imaging)

  • Sang Chul Lee;Ho Kyung Kim;In Kon Chun;Myung Hye Cho;Min Hyoung Cho;Soo Yeol Lee
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권2호
    • /
    • pp.97-102
    • /
    • 2004
  • 소 동물 촬영에 이용될 수 있는 고해상도의 x-선 cone-beam micro computed tomography (micro-CT) 시스템을 개발하였다 Micro-CT 시스템은 120${\times}$120 mm2 의 2차원 평판 x-선 감지기, micro-focus x-선 발생장치, 주사 기구부, 병렬처리 영상 재구성 시스템으로 이루어져 있다. 개발된 시스템의 성능을 평가하기 위해 대조도와 공간해상도를 측정하였다. 대조도 실험에서는 95 mGy 에서 36 CT-번호를 구별할 수 있음을 확인하였고, 공간 해상도 실험에서는 14 lp/mm 의 성능을 확인하였다. 소 동물 촬영 결과로 실험용 쥐의 대퇴부, 심장 그리고 복부 동맥 혈관을 촬영한 경상을 제시하였다. 개발된 micro-CT 시스템은 소 동물을 이용한 생명공학 분야 연구에 널리 이용될 수 있을 것으로 기대된다.

광섬유를 이용한 온도 보상형 마이크로콘의 개발 (Development of Temperature Compensated Micro Cone by using Fiber Optic Sensor)

  • 김래현;이우진;윤형구;이종섭
    • 대한토목학회논문집
    • /
    • 제29권4C호
    • /
    • pp.163-174
    • /
    • 2009
  • 온도 변화에 의하여 로드셀이나 스트레인 게이지의 결과값이 변하기 때문에 로드셀이나 전기저항식 변형율계를 이용하는 기계적 장치는 주변 온도의 변화에 의하여 영향을 받는다. 본 연구에서는 기존의 전기저항식 변형율계 타입의 콘이 가지는 문제점과 한계를 극복하고 관입과 동시에 연속적으로 온도보상이 가능한 직경 1~7mm의 초소형 광섬유 마이크로콘을 개발하였다. 광섬유는 머리카락 굵기의 작은 직경을 가지고 있어 원하는 크기의 센서를 구성할 수 있고 전기적 신호인 전압을 측정하는 것이 아니라 빛의 파장변화를 감지하여 변형율로 변환하게 되므로 주변 조건에 의한 간섭 영향이 거의 없다. 개발된 콘의 온도보상 효과를 검증하기 위해 외력이 없는 상태에서 콘 주변의 온도를 변화시키는 온도시험을 실시하였다. 주변 온도에 따라 측정전압이 변화되는 전기저항식 변형률계 콘과는 달리 광섬유 센서를 적용한 콘은 일정한 값을 유지하는 것으로 나타났으며 관입과 동시에 지중의 온도변화를 연속적으로 확인할 수 있었다. 또한, 다층지반 콘관입시험에서는 관입되는 동안 교란영역이 적고 분해능이 뛰어나 선단지지력의 변화만으로도 다층지반의 경계를 명확하게 탐지할 수 있는 것으로 분석되었다. 본 연구에서는 광섬유 센서를 이용한 초소형 마이크로콘으로 다층지반을 효과적으로 탐지할 수 있으며 지중의 온도 영향이 고려된 순수한 선단저항력을 획득할 수 있음을 보여준다.