• 제목/요약/키워드: Micro climate

검색결과 169건 처리시간 0.03초

단열성능향상 재료를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Insulation Performance Improve Material)

  • 박영신;김정호;강연우;염광수;전현규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.227-228
    • /
    • 2013
  • Recently, it is certain that the increase of heating and cooling energy consumption by radical change in climate condition has caused serious problems related to environmental and energy concerns associated with increase of fossil fuel usage and carbon dioxide production as well as global warming. So, various actions to reduce greenhouse gas exhaustion and energy consumption have been prepared by world developed countries. The energy consumption by buildings approximately reaches 25% of total korea energy consumption. The greatest part in the buildings of the energy consumption is building facade. but a few research projects on concrete comprising more than 70% of outsider of buildings has been tried. This research structural insulation concrete what improved insulation performance using insulation performance improve material.

  • PDF

국제표준(IEC 62305) 도입에 따른 피뢰시스템 검사 및 유지관리에 대한 연구 (A Study on a Regulation Draft of Inspection and Maintenance for Lightning Protection Facilities based on IEC 62305)

  • 이강희;이상협;구경완
    • 전기학회논문지
    • /
    • 제64권5호
    • /
    • pp.838-844
    • /
    • 2015
  • Latest development of ICT makes building, including houses, factories and public facilities, more intelligent and automatized. It follows that a wide variety of electric and ICT installations are adopted along with micro electronic equipments. Corresponding to such changes, the frequency of lightning increases due to the abnormal climate. The major damage by lightning surge is disconnection and malfunction of facilities. It is necessary, therefore, to make a regulation of inspection and maintenance for lightning protection facilities. This paper deals with main issues of a regulation draft of inspection and maintenance for lightning protection facilities based on IEC 62305

하계 동중국해 북부해역에서 종속영양박테리아의 분포 특성 및 미생물 먹이망의 역할 (Spatial distribution of heterotrophic bacteria and the role of microbial food web in the northern East China Sea in summer)

  • 김보미나;윤석현
    • 환경생물
    • /
    • 제41권1호
    • /
    • pp.89-100
    • /
    • 2023
  • 하계 동중국해 북부해역의 표층은 CDW와 HSW 해역으로 구분되며, CDW 해역은 DIN 농도, 총 Chl-a 농도 및 소형 Chl-a 비중이 높았고, 박테리아와 섬모충류 개체수도 높게 나타났다. 상대적으로 영양염 농도가 낮은 HSW 해역에서는 총 Chl-a 농도가 낮고, CDW 해역에 비해 소형 Chl-a 비중은 감소하고, 초미소 Chl-a 비중이 증가한 것으로 나타났다. 박테리아 개체수는 CDW 해역과 유의한 차이가 나타나지 않았지만, 섬모충류 개체수는 감소한 것으로 나타났다. CDW 해역에서는 박테리아가 식물플랑크톤 외에도 용존유기탄소로부터 유기물을 공급받을 것으로 생각되지만, HSW 해역에서는 박테리아가 초미소식물플랑크톤으로부터 배출되는 유기물에 의존하는 것으로 나타났다. 두 해역 모두에서 박테리아와 섬모충류 간의 유의한 상관성이 관찰되지 않아, 조사해역에서는 박테리아가 섬모충류의 주요 먹이원이 아닌것으로 여겨진다. Chl-a 농도가 감소할수록 박테리아 탄소량/식물플랑크톤 탄소량이 증가했으며, 이는 영양염이 풍부한 CDW 해역에 비해 빈영양 수괴의 영향을 받은 HSW 해역에서는 미생물 먹이망의 역할이 더욱 강하게 작용한다는 것을 가리킨다. 본 연구 결과는 CDW 및 빈영양 대마난류의 세기 변화가 식물플랑크톤의 크기 및 군집 분포에 영향을 미치며, 이에 따라 해양 먹이망 내 미생물 먹이망의 기여도가 다르게 나타난다는 것을 시사한다.

마이크로기포제를 사용한 콘크리트의 열적 특성에 관한 연구 (Study on the Thermal Characteristics of Concrete Using Micro Form Admixture)

  • 박영신;김정호;전현규;서치호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2013
  • 최근 전세계는 급격한 기후조건과 환경변화에 의해 냉난방 에너지 사용이 증가되고 있으며 이는 화석 연료 사용량 증가와 함께 $CO_2$ 배출량 상승, 지구 온난화 등 환경과 에너지에 대한 수많은 문제를 유발하고 있어 세계 각국은 온실가스 배출 및 에너지 소비 감소를 위한 대응책을 마련하고 있다. 우리나라 또한 정부의 '저탄소 녹색 성장' 및 '친환경 주택 건설기준 및 성능' 등의 정책을 선포하는 등 건물 부분에 있어 환경과 에너지 관리에 대한 노력을 하고 있다. 우리나라의 총 에너지 소비량 중 건물 부문이 차지하는 비율은 약 25%에 달하며 다른 산업 분야에 비해 연간 에너지 소비 증가율이 높은 편이다. 건물에서 에너지 손실이 가장 큰 부위는 외피로서, 이 부분의 에너지 손실을 감소하기 위한 연구가 활발히 진행되고 있으나 이는 대부분 창호 및 단열재를 사용한 연구이며 건물 외피의 70% 이상을 차지하고 있는 콘크리트에 대한 연구는 미미한 실정이다. 따라서 건물의 에너지 손실을 최소화하기 위해서는 콘크리트 자체에서 단열성능을 확보할 수 있어야 하며 이에 대한 연구가 필요하다. 따라서 본 연구는 콘크리트의 단열성능을 확보하면서 구조용으로 사용이 가능한 콘크리트를 개발하기 위한 실험을 진행하였다. Test 1의 실험결과로써, Micro Foam Admixture (MFA)를 사용한 콘크리트는 슬럼프 경시변화가 개선되었으며, MFA의 혼입율을 증가할 경우 압축강도는 감소되고 열전도율은 증가되는 결과를 나타내었다. Test 2의 실험결과에서는 물시멘트비 변화시 물시멘트비 증가에 따라 압축강도는 감소하였고 열전도율은 증가하였다. 그러나 잔골재율 변화에 대한 물성 및 열적 특성은 큰 차이를 나타내지 않았다.

폐열 회수 시스템용 공랭식 응축기의 압력 손실 저감 설계 (A Design Process for Reduction of Pressure Drop of Air-cooled Condenser for Waste Heat Recovery System)

  • 배석정;허형석;박정상;이홍열;김찬중
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.81-91
    • /
    • 2013
  • A novel design process of a parallel multi-flow type air-cooled condenser of a dual-loop waste heat recovery system with Rankine steam cycles for improving the fuel efficiency of gasoline automobiles has been investigated focusing on reduction of the pressure drop inside the micro-tubes. The low temperature condenser plays a role to dissipate heat from the system by condensing the low temperature loop working fluid sufficiently. However, the refrigerant has low evaporation temperature enough to recover the waste from engine coolant of about $100^{\circ}C$ but has small saturation enthalpy so that excessive mass flow rate of the LT working fluid, e.g., over 150 g/s, causes enormously large pressure drop of the working fluid to maintain the heat dissipation performance of more than 20 kW. This paper has dealt with the scheme to design the low temperature condenser that has reduced pressure drop while ensuring the required thermal performance. The number of pass, the arrangement of the tubes of each pass, and the positions of the inlet and outlet ports on the header are most critical parameters affecting the flow uniformity through all the tubes of the condenser. For the purpose of the performance predictions and the parametric study for the LT condenser, we have developed a 1-dimensional user-friendly performance prediction program that calculates feasibly the phase change of the working fluid in the tubes. An example is presented through the proposed design process and compared with an experiment.

Quantitative analysis of the errors associated with orbit uncertainty for FORMOSAT-3

  • Wu Bor-Han;Fu Ching-Lung;Liou Yuei-An;Chen Way-Jin;Pan Hsu-Pin
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.87-90
    • /
    • 2005
  • The FORMOSAT-3/COSMIC mission is a micro satellite mission to deploy a constellation of six micro satellites at low Earth orbits. The final mission orbit is of an altitude of 750-800 lan. It is a collaborative Taiwan-USA science experiment. Each satellite consists of three science payloads in which the GPS occultation experiment (GOX) payload will collect the GPS signals for the studies of meteorology, climate, space weather, and geodesy. The GOX onboard FORMOSAT -3 is designed as a GPS receiver with 4 antennas. The fore and aft limb antennas are installed on the front and back sides, respectively, and as well as the two precise orbit determination (POD) antennas. The precise orbit information is needed for both the occultation inversion and geodetic research. However, the instrument associated errors, such as the antenna phase center offset and even the different cable delay due to the geometric configuration of fore- and aft-positions of the POD antennas produce error on the orbit. Thus, the focus of this study is to investigate the impact of POD antenna parameter on the determination of precise satellite orbit. Furthermore, the effect of the accuracy of the determined satellite orbit on the retrieved atmospheric and ionospheric parameters is also examined. The CHAMP data, the FORMOSAT-3 satellite and orbit parameters, the Bernese 5.0 software, and the occultation data processing system are used in this work. The results show that 8 cm error on the POD antenna phase center can result in ~8 cm bias on the determined orbit and subsequently cause 0.2 K deviation on the retrieved atmospheric temperature at altitudes above 10 lan.

  • PDF

하계 한반도 해역(동해, 서해, 남해 및 동중국해)의 하위영양단계 먹이망 구조 : 탄소 및 질소 안정동위원소 활용 (Food-Web Structures in the Lower Trophic Levels of the Korean Seas (East Sea, West Sea, South Sea, and East China Sea) during the Summer Season: Using Carbon and Nitrogen Stable Isotopes)

  • 민준오;이창화;윤석현
    • 해양환경안전학회지
    • /
    • 제26권5호
    • /
    • pp.493-505
    • /
    • 2020
  • 본 연구는 2019년 8월 한반도 주변해역(동해, 서해, 남해, 동중국해)에서 탄소 및 질소 안정동위원소 기법을 활용하여 하위영양 단계에서의 먹이망 구조를 파악하였다. 입자성 유기물(POM)의 δ13C 범위는 -26.18 ~ 20.61 ‰, δ15N 범위는 5.36 ~ 15.20 ‰의 넓은 범위를 보였다. POM과 각 생물별 개체군 사이의 δ13C 분별작용의 결과는 대부분 micro-POM을 섭식하는 것으로 확인하였으나 해역 간 차이를 보였다. 각 생물별 영양단계는 chaetognaths (3.40±0.61)가 가장 높은 영양단계에 있음을 확인하였다. 동위원소 혼합모델을 적용한 결과에서 chaetognaths의 먹이원으로 copepods (13 ~ 48 %)와 euphausiids (20 ~ 51 %)가 가장 높은 기여도를 나타냈다. 본 연구결과 각 해역별 먹이원의 제한적 공급 및 다양성의 차이가 먹이망 구조 및 각 생물별 동위원소 비에 영향을 미친 것으로 판단된다.

도시 주차장내 수목그늘의 경제적 이익 연구 -미국 캘리포니아 데이비스 대학 주차장을 사례로- (A Study on the Economic Benefit of Urban Parking Lot Tree Shading -In the Case of University of California Davis Parking Lot-)

  • 장동수
    • 한국조경학회지
    • /
    • 제33권6호
    • /
    • pp.98-108
    • /
    • 2006
  • The climate of urban area is an unstable type with considerable seasonal variation in precipitation wind speed, and temperature and it grows worse. Besides, ozone is a serious air pollutant in most of large cities. So worldwide, some of large cities are investing in forestry options to offset their climate problems, but lack of information has hindered comparisons of urban un cost effectiveness to other options. This research intends to study the economic benefits of tree shading of 19 parking lots in UCD campus. The economic benefits of tree shading are air conditioning savings, air quality, stormwater run-off, and other benefits. Especially, this study focuses how much the economic benefit of parking lot shading has been increased from 1995 to 2003 year by aerophoto. Some data on dimensions of parking lots and the number, size, tree species, and location of trees around each parking lot was inventoried. Two aerophotos(1995,2003) were used in order to analyze the increasement of tree canopy in 19 parking lots for 8 years. However, increasing coverage of trees and managing them for healthy growth would not be sufficient for avoiding adverse impacts by future climate change. Additional measures should be followed such as an increase of energy use efficiency and development of substitute energy. For example, coverage of trees help to save cooling energy by blocking solar radiation reaching parking cars and building structures through shading, and creating cool micro-climates through evapotranspiration. They also reduce heating demand by decreasing air infiltration and heat conduction out of the interior of buildings. Proper arrangement of vegetation over the parking lots can reduce cooling and heating costs. So proper planting design around hard space paving including species selection and location can significantly save cooling and heating energy. And a reduction in car and building's heating and cooling costs results in the reduction in energy demand which causes to emissions of air pollutants. Total increased tree canopy from 1995 to 2003 is $8,470.45m^2$ and the economic benefits is US$ 5,282.10. The economic benefit of one tree has been US$ 7.21 for 8 years. And an annually increased benefit is US$ 0.9 per a tree. If this kind of study is applied to studying the economic benefits of tree canopy in parking lots of Korea, it could result in guidelines of tree planting of parking lots. Because the trees selected for planting in parking lots were not suitable for an environment, the guidelines should contain a recommended list of trees. The guidelines should propose the shading percentage of parking lot when we plan a parking lot and contain the maintenance of trees in order to maximize the economic benefits of tree canopy.

공간계획 활용을 위한 도시 열환경 취약성 평가 연구 - 서울시를 사례로 - (Vulnerability Assessment to Urban Thermal Environment for Spatial Planning - A Case Study of Seoul, Korea -)

  • 엄정희
    • 한국조경학회지
    • /
    • 제44권4호
    • /
    • pp.109-120
    • /
    • 2016
  • 본 연구에서는 열환경 취약성 평가에 관한 국 내외 선행연구 고찰을 바탕으로 열환경 취약성 평가에 적합하면서 도시 및 환경계획 등 공간계획 분야에서 활용할 수 있는 취약성 평가지표를 선정하고, 이를 활용하여 사례지역인 서울시의 열환경 상태를 진단하였다. 이를 위해 폭염, 도시 열섬, 도시 미기후 등 국내 외 열환경 취약성 평가에 활용된 지표들을 고찰하여 도시 열환경 취약성 평가를 위한 15개 지표를 선정하였는데, 기후노출 분야의 건물체적, 민감도 분야의 열환경 취약 건축물, 적응능력 분야의 녹지면적 등 도시구조적 공간적 지표를 포함하였다. 선정된 지표 중 사례지역인 서울지역에 대해 활용가능한 12개 지표의 공간정보를 구축하고, 퍼지이론을 활용한 GIS 공간분석을 통해 서울의 열환경 취약성을 평가하였다. 분석 결과, 강남 지역이 강북 지역보다 열환경에 더 취약한 것으로 파악되었는데, 강남 지역에서는 서초구, 강남구, 동작구, 영등포구, 강서구 일대의 열환경 취약성이 상대적으로 높게 나타났으며, 강북 지역에서는 동대문구, 강북구, 광진구, 중랑구 일대가 다른 구에 비해서 취약성이 높은 것으로 나타났다. 산림지역 및 서울시 외곽지역에 위치한 관악구, 도봉구, 은평구, 노원구 등은 관악산, 북한산 등 산림의 영향으로 인해 '기후노출'과 '민감도' 분야의 취약성이 낮았다. 하지만, 자료수집의 한계로 활용하지 않았던 '적응능력' 분야의 에어컨 보유 현황 지표가 분석에 반영된다면, 서초구, 강남구 등 취약성이 높게 평가된 지역의 결과에 영향을 미쳤을 것으로 예상된다. 본 연구는 기존의 국내 열환경 취약성 평가에서 활용하지 않았던 도시구조적 공간적 지표를 활용함으로써 도시 및 환경계획 분야에서 열취약성을 개선하기 위한 정책 마련에 기여하고, 열환경 위험성을 저감하기 위한 공간계획 수립에 기여할 수 있을 것으로 판단한다.

Environmental Monitoring Using Comfort Sensing System

  • Na, Dae-Suk;Kang, Jeong-Ho;Park, Se-Kwang
    • 센서학회지
    • /
    • 제12권1호
    • /
    • pp.24-33
    • /
    • 2003
  • This research is about a comfort sensing system for human environmental monitoring using a one-bodied humidity and temperature sensor and an air flow sensor. The thermal comfort that a human being feels in indoor environment has been known to be influenced mostly by six parameters, i.e. air temperature, radiation, air flow, humidity, activity level and clothing thermal resistance. Considering an environmental monitoring, we have designed and fabricated a one-bodied humidity and temperature sensor and an air flow sensor that detect air relative humidity, temperature and air flow in human environment using surface micromachining technologies. Micro-controller calculates a PMV (predicted mean vote) and CSV (comfort sensing vote) with sensing signals and display a PMV on LCD (liquid crystal display) for human comfort on indoor climate. Our work has demonstrated that a comfort sensing system can provide an effective means of measuring and monitoring the indoor comfort sensing index of a human being. Experimental results with simulated environment clearly suggest that our comfort sensing system can be used in many applications such as air conditioning system, feedback controlling in automobile, home and hospital etc..