• Title/Summary/Keyword: Micro Display

Search Result 479, Processing Time 0.029 seconds

A Portable Micro-display Driver and Device for Vision Improvement (시력 향상을 위한 휴대형 마이크로디스플레이 구동 드라이버 및 장치)

  • Ryu, Young-Kee;Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.129-135
    • /
    • 2016
  • There are many visual enhancement devices for people with low vision. However, almost conventional devices have been simple magnifying and high cost. The symptoms of people with low vision are very variety. It needs to control of image magnifying, brightness, and contrast to improve the visuality. We developed a portable microdisplay driver and device for visual enhancement. This device based on our suggested four methods such as image magnifying, specific color control, BLU brightness control, and visual axis control using a prism. The basic clinical experiments of the proposed Head Mounted Visual Enhancement Device (HMVED) have been performed. The results show beneficiary effects compared with conventional devices, and improve the life quality on people with low vision on account of low weight, low cost, and easy portability.

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

A Study on the Characteristics of High Pressure DC Glow Discharge with a Narrow Gap (좁은 간격의 고압 DC 글로우 방전에서의 방전물성에 관한 연구)

  • Park, Jae-Seong;Jeong, Heui-Seob;Shin, Buhm-Jae;Whang, Ki-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.435-437
    • /
    • 1995
  • It is important to understand tile behaviours of tile high pressure DC glow discharge with a micro gap inside a pixel of the plasmas display panel. We prepared a narrow gap discharge system and have measured electron temperature and density by means of double probe methods in high pressure which was between 100torr and 200torr. And the electrode gap was 7mm. When the pressure varied from 100torr to 200torr, the negative glow was created at a distance less than 1mm from the cathode. And the length of the faraday dark space decreased from 8mm to 5mm. Hence probe measurements was mainly, performed in the region of the Faraday dark space. The dependence of electron temperature and density on the pressure and current density was same with that of the general flow discharge, i.e. as the pressure increased the electron temperature decreased and the density increased. But the spatial electron density distribution in the Faraday dark space was highly distorted because of the effect of high pressure.

  • PDF

An analysis of Current Science Instruction Adequacy by Micro Instructional Design Theory (내용요소제시이론에 의한 과학교수제시의 적절성 분석 - 과학 I (하) 'V.1.태양계' 단원을 중심으로 -)

  • Paik, Seoung-Hey;Hong, Sung-Il;Yang, Il-Ho;Lee, Jae-Chun
    • Journal of The Korean Association For Science Education
    • /
    • v.14 no.2
    • /
    • pp.184-191
    • /
    • 1994
  • In this study, a part of high school science instructional materials is evaluated by Instructional Quality Profile(IQP) based on the Merrill's Component Display Theory(CDT). The CDT is based on the Gagne assumption of different conditions of learning for different outcomes. The IQP enables the user to check both the consistency and adequacy of existing cognitive instruction. The IQP can be used to predict student performance, and also to design and develop new insturctional materials. The instructional components are classified according to 5 task levels; An Use-Generalities on Newly Encountered Examples(UGeg), A Remember-Paraphrased -Generalities (RpG), A Remember-Verbatim-Generalities (RvG), A Remember-Paraphrased -Examples (Rpeg), A Remember-Verbatim-Examples(Rveg). And the instructional presentations are classified according to 4 levels: Explain Generalities(EG), Explain examples(Eeg), Inquiry Generalities(IG), Inquiry examples(Ieg). The instructional presentations are determined by instructional components of a related test item, and indexes of the presentation adequacy are calculated by the instructional presentations. The indexes of this study(0.17 - 0.44) were very low and it indicates that the instructional presentations were not adequate to the instructional components of the related text item.

  • PDF

A Study on Processing Shape and Overcutting of Invar Sheet by Pulse Electrochemical Machining (펄스전해가공을 이용한 인바 박판의 가공 형상 및 Overcutting 현상에 관한 연구)

  • Yang, Bu-Yeol;Kim, Seong-Hyun;Choi, Seung-Geon;Choi, Woong-Hirl;Chun, Kwang-Ho;Lee, Eun-Sang
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.314-319
    • /
    • 2015
  • Invar is a compound metal of Fe-Ni system contained 36.5% Ni. The characteristic of invar is that the coefficient of thermal expansion is $1.0{\times}10^{-6}cm/^{\circ}C$. It is approximately 10 times smaller than series of steel. Because of this low thermal expansion characteristic of Invar, it is used to shadow mask of display device such as UHDTV or OLED TV. In this study, pulse current from pulse generator instead of DC current is used to overcome the disadvantages of the conventional electrochemical machining. Pulsed current with different duty factor in PECM affect the precise geometry. Pulse electrochemical machining is conducted to machine the micro hole to the invar sheet with different duty factor. The machined shape and overcut of invar sheet with different duty factor is observed by optical microscope and scanning electron microscope (SEM).

Development of a LDI System for the Maskless Exposure Process and Energy Intensity Analysis of Single Laser Beam (Maskless 노광공정을 위한 LDI(Laser Direct Imaging) 시스템 개발 및 단일 레이저 빔 에너지 분포 분석)

  • Lee, Soo-Jin;Kim, Jong-Su;Shin, Bong-Cheol;Kim, Dong-Woo;Cho, Meyong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.834-840
    • /
    • 2010
  • Photo lithography process is very important technology to fabricate highly integrated micro patterns with high precision for semiconductor and display industries. Up to now, mask type lithography process has been generally used for this purpose; however, it is not efficient for small quantity and/or frequently changing products. Therefore, in order to obtain higher productivity and lower manufacturing cost, the mask type lithography process should be replaced. In this study, a maskless lithography system using the DMD(Digital Micromirror Device) is developed, and the exposure condition and optical properties are analyzed and simulated for a single beam case. From the proposed experimental conditions, required exposure experiments were preformed, and the results were investigated. As a results, 10${\mu}m$ spots can be generated at optimal focal length.

Development of 64 channel Cardiac Happing System Using Microcomputer (마이크로 컴퓨터를 이용한 64 채널 심장 전기도 시스템 개발)

  • Cho, Bum-Gu;Chang, Byung-Chul;Kim, Won-Ky;Huh, Jae-Man;Jung, Sung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.142-144
    • /
    • 1991
  • In this study, we have developed 64 channel computerized cardiac mapping system using micro-computer for basic research of electrophysiology and electrical propagation in cardiac arrhythmias. The significant problems of this study are the simultaneous acquisition of large amount data at 64 sites, the need of accurate and rapid analysis, and the effective display of the analyzed data. To solve these problems, we made 64 channel signal pre-processing board in order to amplify and filter the raw signals. And the software for cardiac isochronous mapping which were presented immediately via computer-generated graphics has been developed. This system is expected to enable us to study pathophysiology of cardiac arrhythmia and to improve the results of diagnosis and surgical treatment for cardiac arrhythmia.

  • PDF

Characteristics of Parylene Polymer and Its Applications (파릴렌 고분자의 특성 및 응용)

  • Yoon Young-Soo;Choi Sun-Hee;Kim Joo-Sun;Nam Sang-Cheol
    • Korean Journal of Materials Research
    • /
    • v.14 no.6
    • /
    • pp.443-450
    • /
    • 2004
  • Parylene polymer thin film shows excellent homogeneous coverage chracteristics when it was deposited onto very complex three dimensional solid matters, such as deep hole and micro crack. The parylene deposition process can be conducted at room temperature although most of chemical vapor deposition processes request relatively high processing temperature. Therefore, the parylene coating process does not induce any thermal problems. Parylene thin film is transparent and has extremly high chemical stability. For example, it shows high chemical stability with high reactive chemical solutions such as strong acid, strong alkali and acetone. The bio-stability of this material gives good chances to use for a packaging of biomedical devices and electronic devices such as display. In this review article, principle of deposition process, properties and application fields of parylene polymer thin film are introduced.

Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems (배전원격관리를 위한 차세대 디지털 적산전력계 개발)

  • 고윤석;윤상문;서성진;강태규
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.6
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

Micro replication quality of Fresnel lens using UV imprinting process (UV 임프린팅을 통한 프레넬 렌즈 제작 시 미세 복제 특성에 관한 연구)

  • Lim,, Ji-Seok;Kim, Byung-Wook;Kang, Shin-Ill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.37-40
    • /
    • 2010
  • Fresnel lens is a kind of refractive optical lens with various advantages. It has nearly flat shaped optical lens that has small mass. Fresnel lens has number of applications in the compact optical systems. Recently, demands of high quality Fresnel lens for small size optical systems such as illumination units, compact imaging systems, display units, information storage systems, optical detecting units had increased rapidly. Conventional manufacturing process of high quality Fresnel lens is direct machining. However, it is not suitable for mass production because of high cost and long cycle time. Replication method can provide cost effective mass production process. However, there are various issues about replication of Fresnel lens. Fresnel lens has number of sharp blade shape prism. In the replication process, this blade shape causes defects that can affect optical efficiency. In this study, replication processes; injection molding process and UV imprinting process, were developed and evaluated using Fresnel lens that has maximum pattern height of $250\;{\mu}m$ and aspect ratio of 1.5.