• 제목/요약/키워드: Methods for prosthesis in implants

검색결과 145건 처리시간 0.034초

상악동저 거상술 후 상악 구치부에 식립된 임플란트의 생존율에 대한 연구 (Survival analysis of implants placed in the sinus floor elevated maxilla)

  • 박종연;김옥수;류경호
    • Journal of Periodontal and Implant Science
    • /
    • 제37권2호
    • /
    • pp.151-164
    • /
    • 2007
  • Objective: The sinus floor elevation procedures have been used to facilitate implant placement in the severely atrophic posterior maxilla. Many variables may have an influence on the outcomes of the sinus floor elevation in combination with implant treatment. The aim of this study was to analyze survival rate of implants placed in the edentulous maxillae of patients in whom sinus floor elevation was undertaken according to variables. Materials and Methods: It consisted of 96 patients(50 male and 46 female), ranging in age from 31 to 70 years(mean 49 years), who underwent sinus floor elevation procedure(94 implants in left side and 106 implants in right side) from 2001 to 2002. A total of 200 implants were placed in the grafted sinus(73 implants in lateral approach and 127 implants in crestal approach). All implants were restored by fixed prosthesis. All patients were healthy. Follow-up periods for implants were between 48 to 60 months. Results: The cumulative survival rate of implants was 91.5%. Gender, age and operation site did not have an influence on the survival rate. There was statistically significant differences for the implants which placed in less than 4 or 5 rom residual bone height, the survival rate was 60%, 81.4% respectively (p<0.05). There was no statistically significant difference of implants survival rate ac- cording to approach technique. The survival rate for 100% autogenous bone grafts was lower with respect to composite grafts containing autogenous bone and 100% substitutes. The survival rate for hydroxyapatite-coated implants was statistically significant lower than other textured group (p<0.05). Conclusion: Residual bone height, surface texture and graft materials have an influence on the survival rate. To use autogenous bone as a part of a composite bone replacement, implant texture which leads to more favorable implant-bone interface were necessary. To determine residual bone height for initial implant stability was important.

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

  • Kim, Hyun-Joo;Kim, Yeun-Kang;Joo, Ji-Young;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • 제47권2호
    • /
    • pp.106-115
    • /
    • 2017
  • Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in ${\varnothing}5.0mm$ implants than in ${\varnothing}4.0mm$ implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.

임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도 (Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods)

  • 차지애;한경순
    • 치위생과학회지
    • /
    • 제17권2호
    • /
    • pp.175-182
    • /
    • 2017
  • 본 연구는 성인 375명을 대상으로 임플란트 주위염 자각증상과 만족도를 파악하여 다음과 같은 결과를 얻었다. 임플란트 주위염 자각자율은 식편압입이 40.5%, 출혈 49.1%, 통증 61.1%, 입냄새 61.9%였고, 만족도는 3.95점이었다. 보철방식에서 임플란트-자연치 연결군이 식편 압입(21.3%), 통증(35.5%), 입냄새(36.6%) 모두 가장 낮았고(p<0.001), 출혈은 임플란트 단일군(33.8%)이 가장 낮았다(p<0.05). 만족도는 임플란트-자연치 연결군(4.06점)과 골 이식을 하지 않은 군(4.03점)이 높았다(p<0.01). 요인분석 결과 임플란트 만족도는 임플란트-자연치 연결군에 비해 단일 임플란트군은 0.43배, 임플란트-임플란트 연결군은 0.44배 낮을 가능성을 나타냈다. 이상의 결과를 통해 인접한 자연치의 수명을 최대한 연장하면서 치아결손 부위의 기능을 회복할 수 있는 방법은 임플란트-자연치 연결방식이므로 다각적 검토를 통해 적극 활용할 수 있기를 기대한다.

Clinical outcome of immediately and early loaded implants with laser treated surface: a 3-year retrospective study

  • Leesungbok, Richard;Seo, Jin-Ho;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권2호
    • /
    • pp.163-166
    • /
    • 2018
  • PURPOSE. The marginal bone loss of implants with laser treated surface was investigated after six weeks of loading after implant installation to the mandible molar area. MATERIALS AND METHODS. A total of 23 implants were placed in the edentulous molar area of the mandible: 13 implants were immediately loaded and 10 implants were early loaded. The implants used were made of titanium grade 23, screw shaped, 4.2 mm in diameter, and 10 mm in length. Patients were evaluated with resonance frequency analysis at implant fixture installation and 1, 2 (final prosthesis installation), 3, 5, 8, and 14 months later. X-rays were taken at 2 months after fixture installation and 1, 2, 3 years after to measure the marginal bone loss. RESULTS. The mean ISQ value measured at the implant installation was over 70 at all-time points. The average of marginal bone loss was average 0.33 mm. CONCLUSION. Immediate implant loading for laser treated implants would be possible.

국내에서 치료된 고정성, 가철성, 그리고 임플란트 보철물의 수명 및 성공률 분석 (Analysis of longevity and success rate of fixed, removable, and implant prostheses treated in Korea)

  • 윤준호;박영범;오남식
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.95-104
    • /
    • 2018
  • 목적: 이 연구의 목적은 새롭게 개발된 대한치과보철학회의 보철물 평가 기준을 적용하여 고정성, 가철성 그리고 임플란트 보철물의 성공과 실패를 평가함으로써 보철물의 수명과 이에 관련된 요인을 분석하는 데 있다. 대상 및 방법: 전국 13개 대학/종합병원 보철과에 내원한 환자들을 대상으로 구강내 사용중인 보철물을 평가하였다. 대한치과보철학회의 기준에 따라, 수는 성공, 우, 양, 가는 실패로 규정하고, 실패한 보철물의 평균 사용기간과 실패와 관련된 요인을 분석하였다. Kaplan-Meier 분석에 의한 성공률을 분석하였다. 결과: 고정성 보철 810 증례, 가철성 보철 519 증례, 그리고 임플란트 보철 475 증례, 총 1,804 증례가 연구에 포함되었다. 검사 시점에 실패로 판정된 보철물의 평균 사용기간은 고정성 보철물은 $11.41{\pm}0.30$년, 중간값은 10년이었고, 가철성 보철물은 $8.18{\pm}0.29$년, 중간값 7년이었으며, 임플란트 보철물은 $7.99{\pm}0.30$년, 중간값은 7년이었다. 실패와 관련있는 요인 중 고정성보철물은 유닛 수, 지대치 수, 근관치료된 지대치 수, 치태지수였고, 가철성 보철물의 경우 대합치였으며 임플란트 보철의 경우 임플란트 개수, 사용기간, 치태지수였다. 결론: 대한치과보철학회의 기준으로 보철물을 평가한 결과, 실패한 보철물의 평균수명은 고정성 11.41년, 가철성 8.18년, 그리고 임플란트 보철물은 7.99년이었다.

연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석 (A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH)

  • 정회열;최민호;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

완전 무치악 환자에서 상악 총의치와 하악 임플란트 지지 고정성 보철 치료를 위한 치료법 비교: 증례 보고 (Comparison of treatments for maxillary full denture and mandibular implant-supported fixed prosthesis in completely edentulous patients: A case report)

  • 한진원;표세욱;장재승;김선재
    • 대한치과보철학회지
    • /
    • 제61권1호
    • /
    • pp.73-81
    • /
    • 2023
  • 완전 무치악 환자에서 상악은 전통적인 총의치 치료를 통해 충분한 안정, 지지 및 유지를 얻기 용이하지만, 하악은 해부학적 한계로 인하여 치료에 어려움이 있기 때문에 임플란트를 동반한 치료를 고려할 수 있다. 구치부에 임플란트 식립이 어려운 경우에는 이공 전방에 4 - 5개의 임플란트를 이용하여 하악의 의치를 고정해주는 하이브리드 형 고정성 총의치로 치료할 수 있고, 구치부에 임플란트 식립이 가능한 경우라면 다수 유닛으로 구성되는 임플란트 지지 고정성 보철물을 고려할 수 있다. 이러한 접근방식은 시대가 지남에 따라 수술방식이나 사용하는 재료 등이 다양하게 변해왔다. 본 증례에서는 상악 총의치를 사용하는 완전 무치악 환자의 하악에서 임플란트를 이용한 고정성 보철 치료의 증례를 중심으로 치료 방법을 비교해 보고자 한다.

Masticatory function following implants replacing a second molar

  • Kim, Moon-Sun;Lee, Jae-Kwan;Chang, Beom-Seok;Um, Heung-Sik
    • Journal of Periodontal and Implant Science
    • /
    • 제41권2호
    • /
    • pp.79-85
    • /
    • 2011
  • Purpose: The aim of this study was to obtain objective and standardized information on masticatory function and patient atisfaction following second molar single implant therap. Methods: Twenty adult patient, who had restored second molar single implants more than 1 month before the study, were enrolled in this stud. All patients received a chewing test using peanuts before and after insertion of the implant prosthesi, with a questionnaire and visual analogue scale (VAS) to evaluate the effect of second molar single implant therap. Results: his study obtained standardized information on the masticatory function objectively (e.g., P, R, $X_{50}$) before (Pre-insertion) and after insertion (Post-insertion) of the implant prosthesis. Masticatory performance (P) after insertion of the implant prosthesis significantly increased from $67.8{\pm}9.9$ to $84.3{\pm}8.5$% (P<0.0001). With the implant prosthesis, the P value increased by 24%. The masticatory efficiency index (R) of Post-insertion is higher than that of Pre-insertion (P<0.0001). With the implant prosthesis, the R value increased by 29%. The median particle size ($X_{50}$) of Post-insertion is lower than that of Preinsertion (P<0.0001). More than 90% of the patients were satisfied with the second molar single implant therapy from a functional point of view. Conclusions: These findings indicate that a second molar single implant can increase masticatory function.

요골두 치환술의 임상적 적용 (Clinical Application of Radial Head Prosthesis)

  • 문준규
    • Clinics in Shoulder and Elbow
    • /
    • 제14권1호
    • /
    • pp.140-145
    • /
    • 2011
  • 목적: 금속 요골두 치환술은 주관절 불안정성을 동반한 고정할 수 없는 분쇄된 요골두 골절의 치료로 최근 다양한 임플란트의 개발로 널리 사용되고 있다. 저자는 금속성 요골두 치환술의 적응증과 국내에 사용중인 임플란트의 종류와 수술 술기를 문헌 고찰과 함께 기술하고자 한다. 대상 및 방법: 요골두 치환술의 주 적응증은 동반된 연부조직 손상으로 인한 주관절의 불안정성이 있고, 요골두의 분쇄 골절로 안정적인 내고정이 불가능한 골절이다. 이러한 경우 과거 시행되었던 요골두 절제술은 많은 합병증의 발생으로 금기시되고 있다. 현재 국내에서는 양극성, 압박 고정 단극성 및 이완 고정 단극성 임플란트의 3종류가 수입되어 사용되고 있다. 요골두 치환술은 궁극적으로 원래의 요골두의 크기와 길이로 복원하는 것이 중요하다. 과도하게 긴 요골두의 삽입은 흔한 합병증으로 수술 시 주의가 필요하다. 결과 및 결론: 요골두 치환술은 적절한 적응증과 정확한 수술 술기로 만족할 만한 임상적 결과를 얻을 수 있다. 향후 장기추시 연구와 다양한 치환물들의 임상적인 비교 연구가 필요하다.

Prevalence and risk indicators of peri-implantitis in Korean patients with a history of periodontal disease: a cross-sectional study

  • Goh, Mi-Seon;Hong, Eun-Jin;Chang, Moontaek
    • Journal of Periodontal and Implant Science
    • /
    • 제47권4호
    • /
    • pp.240-250
    • /
    • 2017
  • Purpose: The aim of this study was to analyze the prevalence and risk indicators of peri-implantitis in Korean patients with history of periodontal disease. Methods: A total of 444 patients with 1,485 implants were selected from patients who had been treated at the Department of Periodontology, Chonbuk National University Dental Hospital between July 2014 and June 2015. A group with a history of peri-implantitis (HP) (370 patients with 1,189 implants) and a group with a current peri-implantitis (CP) (318 patients with 1,004 implants) were created based on the radiographic and clinical assessments of implants. The prevalence of peri-implantitis was calculated at both the patient and implant levels. The influence of risk variables on the occurrence of peri-implantitis was analyzed using generalized estimating equations analysis. Results: The prevalence of peri-implantitis in the HP and CP groups ranged from 6.7% to 19.7%. The cumulative peri-implantitis rate in the HP group estimated with the Kaplan-Meier method was higher than that in the CP group over the follow-up period. Among the patient-related risk variables, supportive periodontal therapy (SPT) was the only significant risk indicator for the occurrence of peri-implantitis in both groups. In the analysis of implant-related variables, implants supporting fixed dental prosthesis (FDP) and implants with subjective discomfort was associated with a higher prevalence of peri-implantitis than single implants and implants without subjective discomfort in the HP group. The presence of subjective discomfort was the only significant implant-related variable predictive of peri-implantitis in the CP group. Conclusions: Within the limitations of this study, the prevalence of peri-implantitis in Korean patients with a history of periodontal disease was similar to that reported in other population samples. Regular SPT was important for preventing peri-implantitis. Single implants were found to be less susceptible to peri-implantitis than those supporting FDP. Patients' subjective discomfort was found to be a strong risk indicator for peri-implantitis.