• 제목/요약/키워드: Method for the outer layer of a two-layer wall

검색결과 4건 처리시간 0.021초

비경화성 점착 방수제와 보강메쉬를 이용한 지하 외방수 공법에 관한 연구 (A Study on the Outside Waterproof Method of Ground using Wire-mesh and Non-hardening Viscosity WaterproofBusiness)

  • 문유석;이신춘;권기주;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.213-217
    • /
    • 2009
  • Underground structures are built into concrete like a architecture and public works. Concrete has watertightness as such, But buildings are leaking from the cracks. Recently, construction method do a lot of close construction in the downtown area. So architects are using the method for the outer layer of a two-layer wall to save spaces. They have been using Top-down method and waterproof agent method and others to outer layer of a two-layer wall method. But, There are many leakage in underground structure from lack on requirements performance of materials. Therefore, I hope to test the outside Waterproof Method of Ground using Wire-mesh and Non-hardening Viscosity Waterproof. In addition to, I wish to apply as outside waterproof method for the section for the outer layer of a two-layer wall in underground structure.

  • PDF

주기적 후류 내의 익형 위 천이경계층에 관한 실험적 연구(II) -위상평균된 유동특성- (Experimental Study of Boundary Layer Transition on an Airfoil Induced by Periodically Passing Wake (II) -A Phase-Averaged Characteristic-)

  • 박태춘;전우평;강신형
    • 대한기계학회논문집B
    • /
    • 제25권6호
    • /
    • pp.786-798
    • /
    • 2001
  • This paper describes the phenomena of wake-induced transition of the boundary layers on a NACA0012 airfoil using measured phase-averaged data. Especially, the phase-averaged wall shear stresses are reasonably evaluated using the principle of Computational Preston Tube Method. Due to the passing wake, the turbulent patch is generated in the laminar boundary layer on the airfoil and the boundary layer becomes temporarily transitional. The patches propagate downstream with less speed than free-stream velocity and merge with each other at further down stream station, and the boundary layer becomes more transitional. The generation of turbulent patch at the leading edge of the airfoil mainly depends on velocity defects and turbulent intensity profiles of passing wakes. However, the growth and merging of turbulent patches depend on local streamwise pressure gradients as well as characteristics of turbulent patches. In this transition process, the present experimental data show very similar features to the previous numerical and experimental studies. It is confirmed that the two phase-averaged mean velocity dips appear in the outer region of transitional boundary layer for each passing cycle. Relatively high values of the phase-averaged turbulent fluctuations in the outer region indicate the possibility that breakdown occurs in the outer layer not near the wall.

이중원관 구속제트의 유동특성에 관한 연구 (A Study on Flow Characteristics of Confined Circular Jet within Pipe)

  • 서민식;최장운;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.136-142
    • /
    • 1997
  • The present study is aimed to investigate flow characteristics of confined jet flow within circular pipe. Numerical method based upon revised SOLA scheme which secures conservation form of convective terms on irregular grids by interpolating the variables appearing in staggered meshes is adopted on cylindrical coordinate formation. Computation was carried out for two kinds of Reynolds number, $10^5\;and\;1.5{\times}10^5$ defined by diameter of outer pipe and time-mean driving jet velocity. Results show that periodic vortex shedding from the jet mixing layer is profound and related unsteady flow characteristics prevail over the entire region. Spatial distribution of pressure and kinetic energy, fluctuation of static wall pressure, together with radial velocity components are examined in terms of instantaneous and time-mean point of views.

  • PDF

미세 혈관 접합술에서 봉합적 수기와 비봉합적 수기의 실험적 비교 연구 (Experimental Study of the Anastomosis with Suture vs Non-suture Techinique)

  • 정덕환;한정수;유명철;남기운;선승덕
    • Archives of Reconstructive Microsurgery
    • /
    • 제3권1호
    • /
    • pp.45-53
    • /
    • 1994
  • Suture microvascular anastomosis is time-consuming and tedious and demands long and continuous training. Techinique of anastomosis of microvessel was presented interrupted suture and continuous suture. Recently the unilink instrument system is created as a fast and simple method to achieve high patency rates without long and continuous training in the anastomosis of small vessels. The author experimentally studied the femoral artery of 20 mice(0.5-1.0mm, av. 0.7mm), the femoral vein of 20 mice(0.8-1.6mm, av. 1.2mm) after anastomosis with interrupted suture in 20 cases and continuous sutre in 20 cases. For the unilink apparatus we used the carotid arteries of 15 cases in 14 rabbits(1.0-1.6mm, av. 1.3mm) and facial veins of 12 cases in 14 rabbits(0.9mm-2.2mm, av. 1.5mm). A total of 27 arterial and venous anastomoses were performed. We examined the postoperative patency at immediate, 2 weeks, and 8 weeks. The results were as followings, 1. In the arterial anastomosis the rate of patency was 90%(18/20) in interrupted suture, 90%(18/20) in continuous suture and 93%(13/15) in unilink apparatus. In the venous anastomosis the rate of patency was 90%(18/20) in interrupted suture, 80%(16/20) in continuous suture and 100%(9/9) in unilink apparatus. 2. The mean time for completion of the arterial anastomosis were 12.2 minutes in interrupted suture group, 10.3 minutes in continouous suture group and 8.5 minutes in unillnk apparatus group. The mean time for completion of the venous anastomosis were 13.6 minutes in interrupted suture group, 11.0 minutes in continuous suture group and 6.2 minutes in unilink apparatus group. 3. At the histological examination of suture group, hyperplastic reaction of middle layer and subintimal hyperplasia were observed. In unilink apparatus group, the endothelium layer was continued and the thickness of vessel wall was decreased due to moderate atrophy of the media and mild degree of nonspecific chronic inflammation were seen around the unilink apparatus. 4. No significants was noticied in foreign body reaction among the interrupted, continuous and unilink apparatus group. 5. A case of the arterial anastomosis was released with acting out at 15 minutes after operation. 6. The important factors in the technical problems were accurate apposition of the cut vessel edges in suture group and the proper selection of the ring size and optimal fitting between two rings in unilink apparatus group. Even though the outer diamater of vessel in suture group was different from that in unilink apparatus group the unilink method provides a very safe, fast, and simple way to perform microvascular anastomoses especially in anastomosis of vein. But howerver suture was needed in vessels below 1 mm outer diamater. In that situation continuous suture was benefit than the interrupted suture in operation time.

  • PDF