• Title/Summary/Keyword: Meter-out control

Search Result 81, Processing Time 0.033 seconds

Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus (공기압 구동장치의 에너지효율 평가)

  • Jang, J.S.;Ji, S.W.
    • Journal of Power System Engineering
    • /
    • v.15 no.6
    • /
    • pp.95-100
    • /
    • 2011
  • In this study, an evaluation equation of energy efficiency of pneumatic driving apparatus is proposed. The evaluation equation is derived from state equation and energy equation of air in a control volume, and, the equation of motion of a moving part of a pneumatic cylinder. As a result, distribution of consumption energy and energy efficiency of pneumatic driving apparatus can be analyzed quantitatively. The effectiveness of the proposed method is proved by a pneumatic cylinder driving apparatus using a meter-out driving method.

Development and Performance of Automated Calibration System of Sound Level Meters (소음계 교정 자동화 시스템 개발 및 성능평가)

  • 김용태;조문재;이용봉;서재갑
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

Effects of Chest Compression Quality between Rescuer's Simplified Verbal-Order Method and Continued Verbal-Order Method during Cardiopulmonary Resuscitation (심폐소생술 시 구조자의 간소화된 구령방법과 연속된 구령방법 간의 가슴압박 질 효과)

  • Baek, Hong-Seok;Park, Sang-Sub
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.4
    • /
    • pp.320-330
    • /
    • 2013
  • The purpose of this study is to increase efficiency of CPR through comparing the chest-compression quality between rescuer's simplified verbal order method and the continued verbal order method by utilizing voice meter during CPR. Subjects were 89 people(45 people for the experimental group, 44 people for the control group) who completed the 15-week CPR curriculum as undergraduates for the department of Emergency Medical Technology in C Province and were carried out by being randomly extracted. The group division was set for the experimental group as the group with the simplified verbal order and for the control group as the group with the continued verbal order. The period of measurement was progressed primarily(November 10, November 28, 2011) and secondarily(September 3-September 4, 2012). An analysis was used SPSS WIN 12.0 program. As a result of research, as for the implementation of appropriate chest compression(time, %), the quality was higher(p<.05) in the experimental group(102.86 times, 67.79%) than the control group(85.31 times, 55.84%). As a result of research, the chest compression(time, %) in the experimental group(102.86 times, 67.79%) had the higher effect of chest compression quality(p<.05) than the control group(85.31 times, 55.84%). On the other hand, the operation of weak chest compression(time) was higher in control group(61.13 times) than experimental group(35.54 times). The proper chest compression was shown(p<.05) in men of the experimental group as for gender and in over 60kg of the experimental group as for weight.

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • Kim, Sung-Chan;Chae, Dong-Chul;Kim, Sung-Jun;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.11-17
    • /
    • 2003
  • This paper present a method of meter-out flow control for overload protection valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

Study on Micro Wire Straightening Process in SUS 304 (SUS 304 마이크로 와이어 직선화 처리에 관한 연구)

  • Shin, Hong-Gyu;Kim, Nam-Su;Kim, Woong-Kyum;Hong, Nam-Pyo;Kim, Byeong-Hee;Kim, Heon-Young
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.17-22
    • /
    • 2004
  • In the study, we have developed a straightening system for 304 micro wires that are normally used in the medical and semi-conductor fields. To apply heat to the micro wires, we introduced the direct wire heating method which generates the thermal energy by the electrical resistance of the wire itself. To avoid the deterioration of the wire surface by the environment, such as the oxidation or the hydration, the $N_2$ gas was filled in the glass pipe in which the straightening process was being performed. A precision tension meter was also attached to control the tension of the wire during the heating and straightening process. In order to control the straightening process, several experimental investigations with varying the tension, the feeding velocity and the temperature (current) was carried out. As a result of experiments, we obtained the optimal processing conditions satisfying the straightness requirement of the micro wires.

  • PDF

An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted. (공압 수직실린더의 쿠션특성에 관한 실험적 연구)

  • Kim, Dong-Su;Kim, Hyeong-Ui;Lee, Sang-Cheon
    • 연구논문집
    • /
    • s.28
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

Effect of Jumping Exercise on Supporting Surface on Ankle Muscle Thickness, Proprioception and Balance in Adults with Functional Ankle Instability

  • Park, Chibok;Kim, Byeonggeun
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.2
    • /
    • pp.1756-1762
    • /
    • 2019
  • Background: Functional ankle instability (FAI) indicating a decrease in muscle strength, proprioception, neuromuscular control, balance and postural control function. Objective: To investigate the effect of jumping exercise on the supporting surface on the ankle muscle thickness, proprioceptive sensation, and balance in adults with FAI. Design: Randomized Controlled Trial. Methods: Twenty young people with FAI were randomly assigned to the unstable supporting surface jump group (N=10) and the stable supporting surface jump group (N=10). The intervention was conducted three times a week for eight weeks, and for 30 minutes per session. Trampoline was used as an unstable support surface and the stable support surface was carried out on a regular floor. The thickness of the tibialis anterior muscle and medial gastrocnemius muscle was measured by ultrasonography, and the proprioception of dorsiflexion and plantarflexion was measured using an electrogoniometer. The dynamic balance was also measured with a balance meter. Results: The the muscle thickness of the medial gastrocnemius muscle was significantly higher in the stable supporting surface jump group than in the unstable supporting surface jump group (p<.05). Furthermore, the plantar flexion proprioception and dynamic balance were significantly improved in the unstable supporting surface jump group than in the stable supporting surface jump group in the intergroup comparison (p<.05). Conclusions: The conclusion has been reached in this study that the jumping exercise on the unstable supporting surface could be a more effective in improving FAI than the regular surface.

Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument (방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발)

  • Jang, Ji-Woon;Shin, Hee-Sung;Youn, Cheung;Lee, Yun-Hee;Kim, Ho-Dong;Jung, Ki-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.246-254
    • /
    • 2006
  • A computation program has been developed for automatic data processing in the calibration process of gamma survey meter. The automatic processing program has been developed based on Visual Basic. The program has been coded according to steps of calibration procedure. The OLE(object linking an embedding) Excel automation method fur automatic data processing is used in this program, which is a kind of programming technique for the Excel control. The performance test on the basis of reference data has been carried out by using the developed program. In the results of performance test, the values of calibration factors and uncertainties by the developed program were equal to those obtained from the reference data. In addition, It was revealed that the efficiency and precision of working are significantly increased by using the developed program.

A STUDY OF COMPRESSIVE STRENGTH OF PIN SUPPORTED RESTORATIONS (핀 수복물의 압축강도에 대한 실험적 연구)

  • Lee, Han-Ryong;Lee, Chung-Suck;Choi, Sung-Keun
    • Restorative Dentistry and Endodontics
    • /
    • v.5 no.1
    • /
    • pp.41-46
    • /
    • 1979
  • Silver amalgam has superior mechanical and physical properties, therefore it has been widely used in dental clinics. But we have found the silver amalgam failures frequently, its important reasons are fracture, fallen-out, tarnish, corosion and secondary caries etc. The author studied the compressive strength of silver amalgam. The author made the standardized specimen, prepared the Black's Class II cavity on chromecobalt alloy, and placed the three types of Unitek$^{(R)}$ pin (Type of pins are straight type, "ㄱ" bent type, "$\sqcap$" bent type pin. The compressive strength was measured by (Dynamic Strain Meter Shinko Co. Japan). The author took the following results by comparing with the control group, not used pin. 1) Compressive force of silver amalgam in straight type pin was $187.11{\pm}39.00kg$, $252.98{\pm}31.91kg$ in "ㄱ" type bent pin, $189.00{\pm}37.46Kg$ in "$\sqcap$" type bent pin, $172.33{\pm}28.07Kg$ in the control group. 2) The statistic significance of the compressive strnegth between each group showed that "ㄱ" type, bent pin is stronger than the control group or straight type pin. 3) There were no difference of significances between the control group and straight type pin, control group and "ㄱ" type bent pin and "$\sqap$" type bent pin, "ㄱ" type' bent pin "$\sqcap$" and type bent pin.

  • PDF