• 제목/요약/키워드: Meter-out control

검색결과 81건 처리시간 0.017초

공기압 구동장치의 에너지효율 평가 (Evaluation of Energy Transfer Efficiency of Pneumatic Driving Apparatus)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제15권6호
    • /
    • pp.95-100
    • /
    • 2011
  • In this study, an evaluation equation of energy efficiency of pneumatic driving apparatus is proposed. The evaluation equation is derived from state equation and energy equation of air in a control volume, and, the equation of motion of a moving part of a pneumatic cylinder. As a result, distribution of consumption energy and energy efficiency of pneumatic driving apparatus can be analyzed quantitatively. The effectiveness of the proposed method is proved by a pneumatic cylinder driving apparatus using a meter-out driving method.

소음계 교정 자동화 시스템 개발 및 성능평가 (Development and Performance of Automated Calibration System of Sound Level Meters)

  • 김용태;조문재;이용봉;서재갑
    • 소음진동
    • /
    • 제8권5호
    • /
    • pp.879-886
    • /
    • 1998
  • An automated calibration system of sound level meters was developed and tested. As a standard sound source, the speaker unit(Forstex FE208) cabineted by 440$\times$390$\times$490 $\textrm{mm}^3$(LHW) volume wood box was adopted. Including this source, the driving part was found out to have a good linearity of sound pressure output vs AC voltage input. The Hybrid-Bisect/Newton-Raphson method modified by the linearity was adopted as a searching algorithm. Uisng GPIB interface, the console PC make the control, measurements, and calculations and finally make the accumulation of useful data and results automatically by the instructon in the program coded by C languate. Several trials of automatic calibration using this developed system give the reliable results.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발- (Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • 제20권1호
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

심폐소생술 시 구조자의 간소화된 구령방법과 연속된 구령방법 간의 가슴압박 질 효과 (Effects of Chest Compression Quality between Rescuer's Simplified Verbal-Order Method and Continued Verbal-Order Method during Cardiopulmonary Resuscitation)

  • 백홍석;박상섭
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.320-330
    • /
    • 2013
  • 본 연구는 심폐소생술 시 음성측정기를 활용하여 구조자의 간소화된 구령방법과 연속된 구령방법과의 가슴압박 질 비교를 통해 심폐소생술의 효율성을 높이고자 한다. 대상자는 C도 소재 응급구조과 재학생으로 심폐소생술 15주 교육과정을 이수한 89명(실험군 45명, 대조군 44명)을 무작위추출 하여 시행하였다. 집단 구분은 간소화된 구령집단을 실험군, 연속적 구령집단을 대조군으로 하였다. 실험측정 기간은 1차(2011년 11월 10일, 11월 28일)와 2차(2012년 9월3일-9월4일)로 진행하였다. 분석은 SPSS WIN 12.0 program을 사용하였다. 연구결과 적절한 가슴압박(회, %)은 실험군(102.86회, 67.79%)이 대조군(85.31회, 55.84%) 보다 가슴압박 질 효과가 높았다(p<.05). 반면, 약한 가슴압박(회) 시행은 실험군(35.54회) 보다 대조군(61.13회)이 높았다. 성별에 있어서는 실험군의 남자가, 체중에 있어서는 실험군의 60kg이상이 적절한 가슴압박을 보였다(p<.05).

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • 김성찬;채동철;김성준;황인희
    • 항공우주기술
    • /
    • 제2권2호
    • /
    • pp.11-17
    • /
    • 2003
  • 항공기 전기체 구조시험에 과하중 방지 밸브로 사용되는 미터-아웃방식의 유량제어 방법을 본 보고서로 소개하고자 한다. 전기체 구조시험에서는 여러 요인에 의해 비상시험 중지상태(덤프상태)가 발생하며, 이 상태가 되면 서보밸브의 전원이 차단되어 하중을 가하던 실린더의 양단에 외부조건에 따른 급격한 압력변화가 발생되고, 이 변화는 시험체에 과하중으로 가해진다. 본 연구에서는 덤프로 기인한 하중으로부터 시험체를 보호하기 위해 사용되는 오리피스 면적조절 기술에 대해 소개하였고 실제 시험에서 유압작동기의 덤프특성이 효과적으로 감소되고 있음을 확인하였다.

  • PDF

SUS 304 마이크로 와이어 직선화 처리에 관한 연구 (Study on Micro Wire Straightening Process in SUS 304)

  • 신홍규;김남수;김웅겸;홍남표;김병희;김헌영
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.17-22
    • /
    • 2004
  • In the study, we have developed a straightening system for 304 micro wires that are normally used in the medical and semi-conductor fields. To apply heat to the micro wires, we introduced the direct wire heating method which generates the thermal energy by the electrical resistance of the wire itself. To avoid the deterioration of the wire surface by the environment, such as the oxidation or the hydration, the $N_2$ gas was filled in the glass pipe in which the straightening process was being performed. A precision tension meter was also attached to control the tension of the wire during the heating and straightening process. In order to control the straightening process, several experimental investigations with varying the tension, the feeding velocity and the temperature (current) was carried out. As a result of experiments, we obtained the optimal processing conditions satisfying the straightness requirement of the micro wires.

  • PDF

공압 수직실린더의 쿠션특성에 관한 실험적 연구 (An Experimental Study on Cushion Characteristics of pneumatic Cylinder for Vertically-Mounted.)

  • 김동수;김형의;이상천
    • 연구논문집
    • /
    • 통권28호
    • /
    • pp.73-87
    • /
    • 1998
  • A pneumatic control system of compressed air as a working fluid has a variety of advantages such as low price, high respondence, non-explosion and good control performance and thus has many applications in the field of automobile, electronic and semiconductor industry. However, it has a difficulty in contolling a precise position due to quick response of system and compressibility of working fluid and. in particular, shock stress may occur due to an external load, resulting in fracture of a cylinder cap unless cushion device is equipped in the linear actuator. To avoid this, a cushion device should be installed for damping effect of the external load and the supply pressure as well as for decreasing shock stress and vibration caused by high speed rotation. Previous studies include dimensionless analyses and computer simulations of cushion capability and experiments of horizontally-mounted cylinder performances. A new attempt is experimentally made in this study using a vertically-mounted cylinder under an operation condition of 4, 5 and 6 (bar) as supply pressure and 40, 70 and 100 (kgf) as external load. It turns out that the cushion pressure is mainly a function of the external load rather than the supply pressure. The cushion characteristics was also revealed in the meter-in circuit.

  • PDF

Effect of Jumping Exercise on Supporting Surface on Ankle Muscle Thickness, Proprioception and Balance in Adults with Functional Ankle Instability

  • Park, Chibok;Kim, Byeonggeun
    • 국제물리치료학회지
    • /
    • 제10권2호
    • /
    • pp.1756-1762
    • /
    • 2019
  • Background: Functional ankle instability (FAI) indicating a decrease in muscle strength, proprioception, neuromuscular control, balance and postural control function. Objective: To investigate the effect of jumping exercise on the supporting surface on the ankle muscle thickness, proprioceptive sensation, and balance in adults with FAI. Design: Randomized Controlled Trial. Methods: Twenty young people with FAI were randomly assigned to the unstable supporting surface jump group (N=10) and the stable supporting surface jump group (N=10). The intervention was conducted three times a week for eight weeks, and for 30 minutes per session. Trampoline was used as an unstable support surface and the stable support surface was carried out on a regular floor. The thickness of the tibialis anterior muscle and medial gastrocnemius muscle was measured by ultrasonography, and the proprioception of dorsiflexion and plantarflexion was measured using an electrogoniometer. The dynamic balance was also measured with a balance meter. Results: The the muscle thickness of the medial gastrocnemius muscle was significantly higher in the stable supporting surface jump group than in the unstable supporting surface jump group (p<.05). Furthermore, the plantar flexion proprioception and dynamic balance were significantly improved in the unstable supporting surface jump group than in the stable supporting surface jump group in the intergroup comparison (p<.05). Conclusions: The conclusion has been reached in this study that the jumping exercise on the unstable supporting surface could be a more effective in improving FAI than the regular surface.

방사선 측정기 교정 데이터의 자동처리를 위한 전산프로그램 개발 (Development of a Computation Program for Automatic Processing of Calibration Data of Radiation Instrument)

  • 장지운;신희성;윤청;이윤희;김호동;정기정
    • 비파괴검사학회지
    • /
    • 제26권4호
    • /
    • pp.246-254
    • /
    • 2006
  • 방사선 측정분야에서 사용되는 감마 서베이미터의 교정데이터 자동처리를 위한 전산 프로그램을 개발하였다. 전산 프로그램은 Visual Basic을 기반으로 개발되었으며, 교정과정에 따라 단계별로 윈도우를 제작하고 코드화하였다. 교정 데이터의 자동처리를 위해 Microsoft Excel 프로그램을 제어하여 미리 자동 연산된 엑셀 셀 내에 데이터가 입력되도록 하였다. 개발프로그램 성능평가의 일환으로 검증된 데이터와 프로그램에서 출력된 데이터를 비교한 결과, 교정인자 산출 및 불확도 평가에서 동일한 결과가 나왔다. 또한, 개발프로그램을 교정업무에 적용시킨 결과, 업무의 효율성 및 정확성은 증가하였다.

핀 수복물의 압축강도에 대한 실험적 연구 (A STUDY OF COMPRESSIVE STRENGTH OF PIN SUPPORTED RESTORATIONS)

  • 이한용;이정석;최성근
    • Restorative Dentistry and Endodontics
    • /
    • 제5권1호
    • /
    • pp.41-46
    • /
    • 1979
  • Silver amalgam has superior mechanical and physical properties, therefore it has been widely used in dental clinics. But we have found the silver amalgam failures frequently, its important reasons are fracture, fallen-out, tarnish, corosion and secondary caries etc. The author studied the compressive strength of silver amalgam. The author made the standardized specimen, prepared the Black's Class II cavity on chromecobalt alloy, and placed the three types of Unitek$^{(R)}$ pin (Type of pins are straight type, "ㄱ" bent type, "$\sqcap$" bent type pin. The compressive strength was measured by (Dynamic Strain Meter Shinko Co. Japan). The author took the following results by comparing with the control group, not used pin. 1) Compressive force of silver amalgam in straight type pin was $187.11{\pm}39.00kg$, $252.98{\pm}31.91kg$ in "ㄱ" type bent pin, $189.00{\pm}37.46Kg$ in "$\sqcap$" type bent pin, $172.33{\pm}28.07Kg$ in the control group. 2) The statistic significance of the compressive strnegth between each group showed that "ㄱ" type, bent pin is stronger than the control group or straight type pin. 3) There were no difference of significances between the control group and straight type pin, control group and "ㄱ" type bent pin and "$\sqap$" type bent pin, "ㄱ" type' bent pin "$\sqcap$" and type bent pin.

  • PDF