• Title/Summary/Keyword: Metal mesh

Search Result 299, Processing Time 0.027 seconds

Adsorption of Hg(I), Pb(II), and U(VI) ions using from Fruits of Schizandra Chinensis (오미자를 이용한 Hg(I), Pb(II), U(VI) 이온들의 흡착)

  • Kim, Kwan-Chun;Kim, Joon-Tae
    • Journal of environmental and Sanitary engineering
    • /
    • v.22 no.1 s.63
    • /
    • pp.29-35
    • /
    • 2007
  • This study was examined adsorption ability of heavy metal Hg(I), Pb(II), and U(Vl) ion use of fruit from schizandra chinensis, The fruits of schizandra chinensis sample used breaking into fragments $50{\sim}100$ mesh. The sample solution was mixed fruits of schizandra chinensis and heavy metal ion. Each heavy metal ion of into solution was quantum analysis with ICP-AES. As the result, each condition of maxium adsorption ability of heavy metal ion was high in the range of pH 5-7, adsorption time was about 15 minutes, and the optimum temperature was $100^{\circ}C$. The heavy metal ion was increased adsorption in order of increasing concentration and in ethanol solution better than in aqueous solution.

Molten Metal Flow Analysis of Casting Process Using SPH Method (SPH 기법을 이용한 주조공정 용탕 주입 유동 해석)

  • Park, Byung Lae;Lee, Sang Wook
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.1
    • /
    • pp.54-60
    • /
    • 2018
  • It is important to develop more efficient and productive casting processes for an automated high precision molten-metal casting system. Detailed analysis of molten-metal flow in the casting process by the numerical approach will help to optimize the control of a ladle. In this study, the smoothed particle hydrodynamics method was applied to analyze casting flow characteristics with different tilting angular speed and initial molten-metal level. The smoothed particle hydrodynamics technique has advantages to easily handle non-linear free surface behavior with the absence of a computational mesh. We found that tilting angular speed has relatively greater effect on the casting flowrate and that the effect of the initial molten-metal level is only minor. Further extensive study will be necessary to find an optimal condition for high efficient casting system.

Synthesis of TCO-less Solar Cell using Metal Mesh Type Electrode and its Photovoltaic Characteristics (금속 메쉬 전극을 이용한 TCO-less 광전변환소자 제작 및 광전변환 특성)

  • Park, Min-Woo;Sung, Youl-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.126-130
    • /
    • 2011
  • Transparent conductive oxide (TCO) is an important part in the construction of dye-sensitized solar cells (DSCs) because of its low sheet resistance, sufficient light transparent ability and high photoelectrical response as a porous photo-electrode material of DSCs. However, the use of TCO for the two DSC electrodes can result in significant cost increase for the less effective DSCs compared to Si based solar cell. Therefore, the replacement of TCO is required for the commercial production of DSCs. In this study, TCO electrodes are replaced by stainless steel mesh. The 3.44[%] efficiency of the prepared TCO-less DSCs sample was obtained.

A meshfree method based on adaptive refinement method and its application for deformation analysis (변형해석을 위한 적응적 세분화방법에 기초한 무요소법)

  • Han, Kyu-Taek
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • The finite element method(FEM) presents some limitations when the mesh becomes highly distorted. For analysis of metal forming processes with large deformation, the conventional finite element method usually requires several remeshing operations due to severe mesh distortion. The new computational method developed in the recent years, usually designated by meshfree method, offers an attractive approach to avoid those time-consuming remeshing efforts. This new method uses a set of points to represent the problem domain with no need of an additional mesh. Also this new generation of computational method provides a higher rate of convergence than that of the conventional finite element methods. One of the promising applications of meshfree methods is the adaptive refinement for problems having multi-scale nature. In this study, an adaptive node generation procedure is proposed and also to illustrate the efficiency of proposed method, several numerical examples are presented.

  • PDF

Formation of Metal Mesh Electrodes via Laser Plasmonic Annealing of Metal Nanoparticles for Application in Flexible Touch Sensors (금속 나노 파티클의 레이저 플라즈모닉 어닐링을 통한 메탈메쉬 전극 형성과 이를 활용한 유연 터치 센서)

  • Seongmin Jeong;Yun Sik Hwang;Yu Mi Woo;Yong Jun Cho;Chan Hyeok Kim;Min Gi An;Ho Seok Seo;Chan Hyeon Yang;Kwi-Il Park;Jung Hwan Park
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.2
    • /
    • pp.223-229
    • /
    • 2024
  • Laser-induced plasmonic sintering of metal nanoparticles (NPs) holds significant promise as a technology for producing flexible conducting electrodes. This method offers immediate, straightforward, and scalable manufacturing approaches, eliminating the need for expensive facilities and intricate processes. Nevertheless, the metal NPs come at a high cost due to the intricate synthesis procedures required to ensure long-term reliability in terms of chemical stability and the prevention of NP aggregation. Herein, we induced the self-generation of metal nanoparticles from Ag organometallic ink, and fabricated highly conductive electrodes on flexible substrates through laser-assisted plasmonic annealing. To demonstrate the practicality of the fabricated flexible electrode, it was configured in a mesh pattern, realizing multi-touchable flexible touch screen panel.

Recovery of Tantalum Anode from Waste Tantalum Condenser by Air Classification (공기분급에 의한 폐콘덴서로부터 탄탈륨 회수)

  • Kim Sang-Bae;Cho Sung-Baek;Cho Keon-Joon;Kim Yoon-Jong;Lee Jae-Chun;Kim Won-Baek
    • Resources Recycling
    • /
    • v.12 no.3
    • /
    • pp.3-12
    • /
    • 2003
  • Physical separation containing grinding, sieving, dry magnetic separation and air classification were carried out in order to recover Ta anode from waste Ta condenser. Roll crusher wat used for the liberation of resin and metals in closed circuit system. The liberation between Ta anode and resin was easily achieved, whereat some of metals did not liberated from the Ta anode when the waste condenser was crushed below 8 mesh. When the crushed sample were divided into 8/10 mesh, 10/18 mesh and -18 mesh, metals was mainly remained in 8/10 mesh in contrast to Ta anode was in +18 mesh. It was shown that resin was more easily crushed rather than metals from the result of that resin content was 71.5% in -18 mesh. The liberation efficiency was different with the input size of the crushed sample and average efficiency was 62.3% due to the locked Ta anode particles. The results of air classification test for the crushed samples showed that optimal air flow are 39㎥/h, 32㎥/h, 20㎥/h. respectively. When the sample were separated with optimal condition, 94.45% Ta anode containing 97.47 wt.% Ta anode, 0.93 wt.% resin. 1.61 wt.% metal was recovered with 49.39 wt.% yield.

Effects of Mesh Structure Variations of Meshed Ground on Microstrip Comb Array Antenna (그물망 접지의 그물망 구조의 변화가 MCAA에 미치는 영향)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.69-74
    • /
    • 2018
  • In this paper, We investigated the effects of mesh structure variations of meshed ground on MCAA(Microstrip Comb Array Antenna). First, we designed MCAA in 24GHz ISM band and we investigated the variations of the gain and the SLL(Side Lobe Level) of the MCAA as we varied the mesh structure of the meshed ground. We varied two variables, mesh size and unfilled rato, which is defined as no metal area ratio in mesh for the investigation. We investigated two types of MCAA. Those are flat MCAA composed of flat radiator and tapered MCAA composed of tapered radiator. Both the antenna gains of flat MCAA and tapered MCAA are decreased as the unfilled rato increased. However, increase of mesh size made more dramatic decrease in antenna gain than increase of unfilled rato. The antenna SLL showed similar trend. But tapered MCAA affected more severely by variation of mesh size than flat MCAA.

PM Reduction Efficiency using Metal Type DPF (금속 DPF를 이용한 입자상물질의 저감효율에 관한 연구)

  • Rah, Wan Yong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.176-180
    • /
    • 2013
  • After-treatment apparatus ceramic DPF (diesel particulate filter) have been applied to reduce harmful particulate matters(PM) among emissions from diesel engines so far, but they are easy to be fragile and weak in thermal shock. This research aims to investigate a metal type filter which is superior in mechanical strength and heat conduction rate and is beneficial economically in manufacturing. Basic performance of metal DPF such asloading test, temperature gradient test, thermal shock test, heat resistant test and back pressure was carried out. And then their experimental data provided key informations in designing and manufacturing such as detailed structures of metal mesh filter. Also diesel engine and vehicle of 2957cc displacement was tested under lug-down 3 mode and CVS-75 mode. PM reduction efficiency was 54.5% using metal DPF without loss of performance and fuel consumption.

Effects of Korea Lycium chinense Miller, Schizandra chinensis Baillon, Pueraria thunbergiana Benth, Eucommia ulmoides Oliv Tea Beverage on the Removal of Heavy Metal (한국산 구기자, 오미자, 갈근, 두충차 음료의 중금속 흡착율)

  • 한성희;신미경;김용욱
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.9 no.3
    • /
    • pp.363-369
    • /
    • 1999
  • The heavy metal removability of four kinds of tea was investigated in the various conditions: particle size of tea(10, 35. 70, 100 mesh), concentration of heavy metal(25, 50, 100ppm) and extraction temperature(30. 50, 70. 10$0^{\circ}C$). The removabilities by the tea solids were increased as the particle size decreased, concentration of heavy metal increased, and extracting temperature increased. Of the four kinds of tea Pb, Cd and Cu removability by Eucommia ulmoides Oliv tea was the highest. In addition, heavy metal removability by Schizandra chinensis Baillon tea was better than that of other tea as extraction temperature was increased.

  • PDF

A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests (PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석)

  • Yun, Sun-Hee;Kim, Yang-Jung;Kang, Young-Jik;Park, Su-Young;Kim, Ho-Sin;Ryu, Hyoung-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF