• Title/Summary/Keyword: Metal casting

Search Result 593, Processing Time 0.019 seconds

Radiation Therapy Using M3 Wax Bolus in Patients with Malignant Scalp Tumors (악성 두피 종양(Scalp) 환자의 M3 Wax Bolus를 이용한 방사선치료)

  • Kwon, Da Eun;Hwang, Ji Hye;Park, In Seo;Yang, Jun Cheol;Kim, Su Jin;You, Ah Young;Won, Young Jinn;Kwon, Kyung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.75-81
    • /
    • 2019
  • Purpose: Helmet type bolus for 3D printer is being manufactured because of the disadvantages of Bolus materials when photon beam is used for the treatment of scalp malignancy. However, PLA, which is a used material, has a higher density than a tissue equivalent material and inconveniences occur when the patient wears PLA. In this study, we try to treat malignant scalp tumors by using M3 wax helmet with 3D printer. Methods and materials: For the modeling of the helmet type M3 wax, the head phantom was photographed by CT, which was acquired with a DICOM file. The part for helmet on the scalp was made with Helmet contour. The M3 Wax helmet was made by dissolving paraffin wax, mixing magnesium oxide and calcium carbonate, solidifying it in a PLA 3D helmet, and then eliminated PLA 3D Helmet of the surface. The treatment plan was based on Intensity-Modulated Radiation Therapy (IMRT) of 10 Portals, and the therapeutic dose was 200 cGy, using Analytical Anisotropic Algorithm (AAA) of Eclipse. Then, the dose was verified by using EBT3 film and Mosfet (Metal Oxide Semiconductor Field Effect Transistor: USA), and the IMRT plan was measured 3 times in 3 parts by reproducing the phantom of the head human model under the same condition with the CT simulation room. Results: The Hounsfield unit (HU) of the bolus measured by CT was $52{\pm}37.1$. The dose of TPS was 186.6 cGy, 193.2 cGy and 190.6 cGy at the M3 Wax bolus measurement points of A, B and C, and the dose measured three times at Mostet was $179.66{\pm}2.62cGy$, $184.33{\pm}1.24cGy$ and $195.33{\pm}1.69cGy$. And the error rates were -3.71 %, -4.59 %, and 2.48 %. The dose measured with EBT3 film was $182.00{\pm}1.63cGy$, $193.66{\pm}2.05cGy$ and $196{\pm}2.16cGy$. The error rates were -2.46 %, 0.23 % and 2.83 %. Conclusions: The thickness of the M3 wax bolus was 2 cm, which could help the treatment plan to be established by easily lowering the dose of the brain part. The maximum error rate of the scalp surface dose was measured within 5 % and generally within 3 %, even in the A, B, C measurements of dosimeters of EBT3 film and Mosfet in the treatment dose verification. The making period of M3 wax bolus is shorter, cheaper than that of 3D printer, can be reused and is very useful for the treatment of scalp malignancies as human tissue equivalent material. Therefore, we think that the use of casting type M3 wax bolus, which will complement the making period and cost of high capacity Bolus and Compensator in 3D printer, will increase later.

Comparison on the Fracture Strength Depending on the Fiber Post and Core Build-up (섬유 강화 포스트와 코어 축성 방법에 따른 파절 강도에 관한 비교)

  • Lee, Ja-Hyoung;Shin, Sooyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.225-235
    • /
    • 2009
  • A common procedure of restoration of endodonticlly treated tooth with fiber-reinforced post is followed by core build-up after post cementation. However, this technique is complex and time-consuming. The aim of this study was to compare fracture strength of premolar, restored with various methods of core fabrications on fiber-reinforced posts and casting metal restoration. Forty five freshly extracted human mandibular premolars were obtained and devided into 5 groups acconding to the type of post and methods of core build-up. In Group A, D.T. $Light-post^{(R)}$ were cemented with $DUO-LINK^{TM}$ and then $LIGHT-CORE^{TM}$ was used for core restoration. In Group B, D.T. $Light-post^{(R)}$ and $DUO-LINK^{TM}$ were used for cementing in the postspace, and $DUO-LINK^{TM}$ was used again for core restoration. In Group C, $Light-post^{(R)}$ bonding and the core build-up were performed simultaneously by using $DUO-LINK^{TM}$. In Group D, $LuxaPost^{(R)}$ was bonded by using $LuxaCore^{(R)}-Dual$. Again, $LuxaCore^{(R)}-Dual$ was used for core restoration. In Group E, $LuxaPost^{(R)}$ bonding and the core build-up were performed simultaneously by using $LuxaCore^{(R)}-Dual$. Axial reduction was formed parallelly as possible and 45 degree bevel was made at buccal occlusal surface. Crowns were fabricated and cemented. Each tooth was embedded in self-curing acrylic resin to the level of 2mm below the CEJ. Specimens were fixed on universal testing machin such that the axis of the tooth was at 45 degree inclination to the horizontal plane, and compressive force was applied at a crosshead speed of 1mm/min until failure occurred. The mean fracture strength was the highest in group A followed by descending order in group B, D, E and C. However, there were no statistically significant differences between groups with regard to the fracture strength. The type of the post or build-up methods of the core does not seem to influence the fracture strength.

A Study of the Bracelets Excavated from Fifth-and Sixth-century Silla Kingdom Tombs: Physical Characteristics and Wearing Practices (신라 5~6세기 무덤 출토 팔찌에 대한 연구 -물리적·형태적 특성 및 착장 양상을 중심으로)

  • Yoon Sangdeok
    • Bangmulgwan gwa yeongu (The National Museum of Korea Journal)
    • /
    • v.1
    • /
    • pp.174-197
    • /
    • 2024
  • Personal ornaments made from precious metals that have been excavated from tombs dating to the Maripgan period (4th-6th century) of the Silla Kingdom are a major subject of analysis in the study of gender and hierarchy among the tomb occupants. Nonetheless, bracelets had been neglected until Ha Daeryong's recent research on determining gender through bracelets attracted attention. Accordingly, an examination and organization of the fundamental elements of Silla bracelets was needed. In response, this paper examines their physical characteristics, appearance, changes over time, and related wearing practices. The data for this study is derived from 176 bracelets, mostly made from silver or gold. Copper and glass bracelets are also included. Many of them were cast in a single-use earthen mold. Even the notched and protruding designs were created by casting rather than carving. Glass bracelets and bracelets with dragon designs were made using molds with round cavities. Excluding those produced using metal sheets, the rest of the bracelets are thought to have been cast in a mold with a long-string-shaped cavity and then bent round. After being bent, the two ends were either soldered together (closed type) or left open (open type). As demonstrated in the study by Lee Hansang, Silla bracelets evolved from plain rounded rod-shaped bracelets, such as the one excavated from the Northern Mound of Hwangnamdaechong Tomb, to versions with notched designs, and eventually to those with protruding designs, which gained popularity by the sixth century. The precedents of plain rounded rod-shaped bracelets are presumed to have been thin rod-shaped bracelets from the Proto-Three Kingdoms period. Bracelets need to be fit to the wrists so that they do not slip off easily when worn. The open type design was the preferable way to achieve this. Moreover, given the ductility of gold, silver, and copper, it seems that it would have been possible to stretch or deform them. In the end, I concluded that even if a bracelet is too small to pass man's hand, the open type could have been worn. Furthermore, if a closed-type bracelet were pressed into an oval shape, it would not be impossible for a man to put it on. When bracelets are divided according to their degree of deformability into type A (the open type) through type D, which is almost impossible to deform, type A is commonly found with wearers of thin hollow earrings, and types C and D (which are difficult to deform) are not found with wearers of thin hollow earrings, but only with wearers of thick hollow earrings. Therefore, it can be seen that men were allowed to wear bracelets, and the existing studies that differentiate between men and women based on the wearing of thin hollow earrings, thick hollow earrings, and swords remain valid.