• Title/Summary/Keyword: Metal Roof

Search Result 43, Processing Time 0.021 seconds

Present Deterioration Situation and Study on the Cleaning of the Surface of the Octagonal nine storied pagoda of Woljeongsa Temple (월정사팔각구층석탑의 손상현황과 표면오염물 제거연구)

  • Hwang, Jeong Eun;Kim, Sa Dug;Jung, Hee Soo
    • 보존과학연구
    • /
    • s.33
    • /
    • pp.125-148
    • /
    • 2012
  • The Octagonal nine storied pagoda of Woljeongsa Temple consists mainly of granite with the rockforming minerals quartz, plagioclase, microcline, and biotite. The surface of the stone stupa is light brown that has been discolored by the rust from the metal ornament and aids. The surface of the stylobate and roof stone is colonized by biological contaminants. Therefore, a comprehensive deterioration diagnosis was carried out in this study, and conservation treatment was conducted. It was proven that the $Fe^{2+}$ yield increases depending on the count of poultice used with oxalic acid, but the $Mg^{2+}$, $Al^{3+}$, and $Ca^{2+}$ yields were marginal following the preliminary test. Therefore, the use of poultice is an effective way of removing the rust, and only marginally influences the rock. The biological contaminants were removed through dry cleaning, and the soil located under the contaminants was removed through wet cleaning. Based on this, the dry and wet cleaning of all the biological contaminants, and the use of poultice with oxalic acid, were done to remove the rust. For the conservation treatment of the metal ornament, the rust was removed through physical cleaning, and anticorrosion treatment was performed on the iron ornament using Renaissance wax and copper ornament by BTA.

  • PDF

Exposure status of welding fumes for operators of overhead traveling crane in a shipyard (대형조선소 천장크레인 운전원의 용접흄 노출 실태)

  • Lee, Kyeongmin;Kim, Boowook;Kwak, Hyunseok;Ha, Hyunchul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.301-311
    • /
    • 2015
  • Objectives: Operators of overhead traveling crane in a ship assembly factory perform work to transmit large vessel blocks to an appropriate working process. Hazardous matters such as metal dusts, carbon monoxide, carbon dioxide, ozone, loud noise and fine particles are generated by variable working activities in the factory. The operators could be exposed to the hazardous matters during the work. In particular, welding fumes comprised of ultra fine particles and heavy metals is extremely hazardous for humans when exposing a pulmonary through respiratory pathway. Occupational lung diseases related to welding fumes are increasingly on an upward tendency. Therefore, the objective of this study is to assess properly unknown occupational exposure to the welding fumes among the operators. Methods: This study intended to clearly determine an equivalence check whether or not chemical constituents and composition of the dusts, which existed in the driver's cab, matched up with generally known welding fumes. Furthermore, computational fluid dynamics program(CFD) was used to identify a ventilation assessment in respect of a contamination distribution of welding fumes in the air. The operators were investigated to assess personal exposure levels of welding fumes and respirable particulate. Results: The dust in an operation room were the same constituents and composition as welding fumes. Welding fumes, which caused by the welding in a floor of the factory, arose with an ascending air current up to a roof and then stayed for a long time. They were considered to be exposed to the welding fumes in the operation room. The personal exposure levels of welding fumes and respirable particulate were 0.159(n=8, range=0.073-0.410) $mg/m^3$ and 0.138(n=8, range=0.087-0.178) $mg/m^3$, respectively. They were lower than a threshold limit value level($5mg/m^3$) of welding fumes. Conclusions: These findings indicate that an occupational exposure to welding fumes can exist among the operators. Consequently, we need to be keeping the operators under a constant assessment in the operator process of overhead traveling crane.

Analysis of Surface Temperature Characteristics by Land Surface Fabrics Using UAV TIR Images (UAV 열적외 영상을 활용한 피복재질별 표면온도 특성 분석)

  • SONG, Bong-Geun;KIM, Gyeong-Ah;SEO, Kyeong-Ho;LEE, Seung-Won;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.3
    • /
    • pp.162-175
    • /
    • 2018
  • The purpose of this study was to analyze the surface temperature of surface fabrics using UAV TIR images, to mitigate problems in the thermal environment of urban areas. Surface temperature values derived from UAV images were compared with those measured in-situ during the similar period as when the images were taken. The difference in the in-situ measured and UAV image derived surface temperatures is the highest for gray colored concrete roof fabrics, at $17^{\circ}C$, and urethane fabrics show the lowest difference, at $0.3^{\circ}C$. The experiment power of the scatter plot of in-situ measured and UAV image derived surface temperatures was 63.75%, indicating that the correlation between the two is high. The surface fabrics with high temperature are metal roofs($48.9^{\circ}C$), urethane($43.4^{\circ}C$), and gray colored concrete roofs($42.9^{\circ}C$), and those with low temperature are barren land($30.2^{\circ}C$), area with trees and lawns($30.2^{\circ}C$), and white colored concrete roofs($34.9^{\circ}C$). These results show that accurate analysis of the thermal characteristics of surface fabrics is possible using UAV images. In future, it will be necessary to increase the usability of UAV images via comparison with in-situ data and linkage to satellite imagery.