고성능 서지보호 시스템 개발 및 성능 평가 (Development and/or Characteristics Evaluation of High Performance SPD(Surge Protective Device))

  • 김재훈;김주한;한상옥;김선호;구경완
    • 전기학회논문지P
    • /
    • 제58권3호
    • /
    • pp.328-333
    • /
    • 2009
  • In this paper, we have developed high performance SPD(surge protective device) and evaluated the characteristics in comparison with typical SPD used in the inside and outside of the country. The new SPD was composed of MOV(metal oxide varistor), GDT(gas discharge tube) and impedance such as resistors, capacitors or varistors. To estimate operating the characteristic of the SPD which was developed, it was measured surge voltage caused by fault current or surge according to IEC 61000-4-5. As a result it was found that the power supply was cut off by high performance SPD when caused a short-circuit. In addition we could know that it could prevent ELB(earth leakage breaker)'s malfunction caused by surge.

서지보호기의 상태 감시를 위한 MOV의 고장률 예측 (Failure Rate Estimation of MOV for Condition Monitoring of Surge Protective Devices)

  • 김동진;김영선;박재준;이기식
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1302-1307
    • /
    • 2013
  • MOV(Metal Oxide Varistor) is the most important part of SPD(Surge Protective Device) which can protect electric facilities from an impulse current such as a lightning. So far, the fault of MOVs have decided only by surge count without considering magnitude of surge current and an amount of input energy. This paper proposed the fault prediction algorithm for the MOV using look up table made by surge count and input current data which have non-linear characteristics for input current and are estimated by high voltage experimental results. Proposed algorithm was proved by experiment on verification at a high voltage laboratory.

옥외용 전자장비의 낙뢰 서지 대책 (Protecting electronic equipment against lightning surge)

  • 임순재;이주광;이완규;최만용
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.29-36
    • /
    • 1997
  • Precision electronic equipments for outdoor use are composed of sophisticated microcircuits that are extremely vulnerable to lightning-caused voltage spike. This transient voltage spike may cause upset, latent failure or Interference on electronic equipments. In order to develop efficient lightning protection measures on AC power lines of a road traffic controller as a electronic equipment for outdoor use, experimental surge immunity tests were conducted according to IEC standard 801-5. The combination of gas tube arrester and metal-oxide varistor was installed at the input of AC power lines and the silicon avalanche suppressor installed at the output of DC power supply for the lightning protection measures.

  • PDF

전류구동형 서지카운터 (Current Driving Type Surge Counter)

  • 이복희;안창환;장석훈;정관모;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1712-1714
    • /
    • 1997
  • This paper deals with the surge counter drived by lightning and switching currents. In order to install the effective surge protective devices, it is important to find the parameters of incident surges. In this paper, for the purpose of protecting the electronic circuits and counting the occuring frequency, the current driving type surge counter is designed and fabricated. The surge counter consists of surge protective divices, current detector, metal oxide varistor(MOV), rectifier, capacitor, and electromagnetic counter. This surge counter is able to count the occuring frequency of surges and to clamp lightning surge current. To evaluate the performance of the surge counter, impulse voltage and current were applied at the surge counter by the surge generator. As a result, applied surges were exactly counted and clamped.

  • PDF

건물의 직격뢰시 본딩 방식에 따른 서지 진압 분포 (Surge Voltage Distribution at the Different Bonding Practice During a Direct Lightning Stroke to Building)

  • 이재복;장석훈;명성호;조연규
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.444-450
    • /
    • 2008
  • There are several ways to bond to building grounding systems for reducing GPR(ground potential rise) and EMI resulting from power system faults or lightning stroke to building. In order to verify effective bonding practice, the GPR and voltage of equipment due to the direct stroke to building are calculated with ATP-EMTP model for transformer, transmission line and MOV(Metal oxide varistor). The simulated model shows a satisfactory accuracy compared with experimental result for the $8/20{\mu}s$ simulated current pulse. It is observed that separate grounding can cause dangerous voltage to the building equipment and the performance of surge protective device can improve when it is installed to the protected equipment in distance as short as possible.

초고압용 피뢰기 산화아연소자의 전기적 특성 평가 (Evaluation of Electrical Characteristics of Metal Oxide Varistors for Surge Arresters)

  • 조한구;윤한수;김석수;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.46-49
    • /
    • 2005
  • This paper presents the electrical characteristics of metal oxide varistors for lightning surge arresters. ZnO varistors were fabricated with typical ceramic production methods and two types of varistors were also prepared to be compared. The nominal discharge current and line discharge class of those varistors are $10kA(8/20{\mu}s)$ and class 3, respectively. The diameter of varistors manufactured and prepared were in the range of 61.6~65.0mm and the thickness of those were in the range of 27~42.52mm. The reference and residual voltage were tested and reference and residual voltage per 1mm and the ratio of reference and residual voltage were calculated. The reference voltage per 1mm of varistors manufactured was about 175V/mm but that of A's and B's varistors was nearly 200V/mm. The residual voltage exhibited the same trends as the reference voltage, so the reference and residual voltage per 1mm of domestic varistors should be increased. According to the results of tests, it is thought that if the reference and residual voltage per 1mm were increased to 200V/mm and 330V/mm, domestic ZnO varistors would be possible to apply to the station class arresters in the near future.

  • PDF

피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구 (A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester)

  • 정기석;길형준
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

MOV 기반 서지보호기의 일시과전압 특성에 대한 실험적 연구 (Experimental Study on Temporary Overvoltage Characteristics of MOV Based Surge Protective Devices)

  • 심해섭;전태현
    • 조명전기설비학회논문지
    • /
    • 제24권1호
    • /
    • pp.71-77
    • /
    • 2010
  • 뇌서지 보호는 오늘날 대부분의 전기전자기기에 있어 중요한 문제 중 하나이다. 그리고 뇌서지 보호를 위한 대다수 SPD의 가장 주요 부품으로 MOV가 사용된다. 본 논문에서는 다양한 타입의 MOV 기반 SPD를 조사하고 낮은 MLV특성의 부작용에 대하여 실험하였다. 실험결과로서 상대적으로 낮은 MLV특성은 실제 현장에서 발생 가능한 TOV 고장 상태하에서 더 큰 고장률로 나타날 수 있으며, 피보호기기보다 우선하여 소손될 수 있음을 알 수 있다. 결국 안전면에서 SPD는 높은 TOV내력과 신속한 단로기의 동작이 요구된다.

저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조 (Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations)

  • 이복희;김회구;박희열;안창환
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

누전차단기의 뇌써지 동작특성 분석 및 오동작 대책 (Analysis and Countermeasures for False-Tripping of Earth Leakage Breaker Due to Lightning Surge)

  • 이재복;명성호;조연규;장석훈;김점식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.479-484
    • /
    • 2002
  • Recently it is reported that many a malfunction of ELB which is represented by non-operated type ELB for an impulse wave, is caused by lightning impulse and transient ground potential rise due to nearby lightning strokes. In order to examine the cause of malfunction, 5 samples were investigated experimentally in this study. As each ELB has a different leakage current detecting circuit and wiring method, various characteristics were measured. As a result, all of them brought about malfunctions under the lightning impulse voltage less than 7 kV and the surge current less than 3 kA. Also the different aspects were measured with a polarity of injected surge and a position of MOV to protect the inner circuit of ELB. The Position and effects of protecting devices were suggested as a remedy.