• 제목/요약/키워드: Membrane resistance

검색결과 862건 처리시간 0.026초

Happel Cell 모델을 이용한 막오염 지수 예측 (Prediction of Membrane Fouling Index by Using Happel Cell Model)

  • 박찬혁;김하나;홍승관
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.632-638
    • /
    • 2005
  • Membrane fouling index such as Silt Density Index (SDI) and Modified Fouling Index (MFI) is an important parameter in design of the integrated RO/NF membrane processes for drinking water treatment. In this study, the effect of particle, membrane and feed water characteristics on membrane fouling index were investigated systematically. Higher fouling index values were observed when filtering suspensions with smaller particle size and higher feed particle concentration. Larger membrane resistance due to smaller pore size resulted in an increased membrane fouling index. The variations of feed water hardness and TDS concentrations did not show any impact on fouling index, suggesting that there were no significant colloidal interactions among particles and thus the porosity of particle cake layer accumulated on the membrane surface could be assumed to be 0.36 according to random packing density. Based on the experimental observations, fundamental membrane fouling index model was developed using Happel Cell. The effect of primary model parameters including particle size ($a_p$), particle concentration ($C_o$), membrane resistance ($R_m$), were accurately assessed without any fitting parameters, and the prediction of membrane fouling index such as MFI exhibited very good agreement with the experimental results.

Kanendomycin이 토끼 적혈구막의 포타슘 투과에 미치는 영향 (The Effects of Kanendomycin on the Potassium Permeability of the Rabbit Erythrocyte Membrane)

  • 김정한
    • The Korean Journal of Physiology
    • /
    • 제8권1호
    • /
    • pp.45-53
    • /
    • 1974
  • The effects of kanendomycin on the potassium permeability in the rabbit erythrocyte membrane are investigated and the results are summarized as follows. 1. Kanendomycin causes the efflux of $K^+\;and\;influx\;of\;Na^+$ across the rabbit erythrocyte membrane. 2. Osmotic resistance of kanendomycin treated erythrocytes is diminished. This diminution of osmotic resistance is more pronounced by increasing concentration of kanendomycin and longer incubation time. But osmotic resistance is rather increased in the presence of lower concentration of kanendomycin. 3. Cysteine and glutathione have little influence on $K^+$ efflux induced by kanendomycin. 4. EDTA has no effect on the increase in $K^+$ outflux by kanendomycin while PCMB augments slightly on $K^+$ outflux. 5. Kanendomycin inhibits $Ca^{++}$ binding competitively to rabbit erythrocyte membrane fragments.

  • PDF

Pervaporation Separation of Water/Ethanol Mixtures through PBMA/anionic PAA IPN Membrane

  • Jin, Young-Sub;Kim, Sung-Chul
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1996년도 추계 총회 및 학술발표회
    • /
    • pp.86-87
    • /
    • 1996
  • IPN (Interpenetrating Polymer Network) is a mixture of two or more crosslinked polymers with physically interlocked network structures between the component polymers. IPN can be classified as an alloy of thermosets and has the characteristics of thermosets such as the thermal resistance and chemical resistance and also has the characteristics of polymer alloys with enhanced impact resistance and amphoteric properties. The physical interlocking during the synthesis restricts the phase separation of the component polymer with chemical pinning process, thus the control of morphology is possible through variations of the reaction temperature and pressure, catalyst concentration and crosslinking agent concentration. Finely dispersed domain structure can be obtained through IPN synthesis of polymer components with gross immiscibility. In membrane applications, particularly for the separation of liquid mixtures, crosslinked polymer component with specific affinity to the permeate is needed. With the presence of the permeant-inert polymer component, the mechanical strength and the selectivity of the membranes are enhanced by restricting the swelling of the transporting polymer component networks.

  • PDF

계면활성제의 분리막에 대한 투과거동 (Permeation Behavior of Surfactant through Membrane)

  • 안순철;이광래;김기창
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.259-265
    • /
    • 1998
  • The molecular weights of surfactant SDS(M.W. 288) and SLS(M.W. 420) are smaller than the molecular weigh cut-off of cellulose acetate membrane used in this study. However, 20% of SDS and 67% of SLS were rejected by cellulose aectate membrane. The higher rejection rate of SLS than that of SDS is due to the longer hydrophobic chain and greater molecular weight. There was no resistance to permeation rate by membrane fouling. Most of permeation resistance was due to the concentration polarization. Permeation rate was declined with operating time and with increase in concentration of surfactant due to concentration polarization.

  • PDF

Fouling behaviours of two stages microalgae/membrane filtration system applied to palm oil mill effluent treatment

  • Teow, Yeit Haan;Wong, Zhong Huo;Takriff, Mohd Sobri;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • 제9권5호
    • /
    • pp.373-383
    • /
    • 2018
  • Fouling by solids and microorganisms is the major obstacle limiting the efficient use of membrane wastewater treatment. In our previous study, two stages microalgae/membrane filtration system was proposed to treat anaerobic digested palm oil mill effluent (AnPOME). This two stages microalgae/membrane filtration system had showed great potential for the treatment of AnPOME with high removal of COD, $NH_3-N$, $PO_4{^{3-}}$, TSS, turbidity, and colour. However, fouling behavior of the membrane in this two stages microalgae/membrane filtration system was still unknown. In this study, empirical models that describe permeate flux decline for dead-end filtration (pore blocking - complete, intermediate, and standard; and cake layer formation) presented by Hermia were used to fit the experimental results in identifying the fouling mechanism under different experimental conditions. Both centrifuged and non-centrifuged samples were taken from the medium with 3 days RT intervals, from day 0 to day 12 to study their influence on fouling mechanisms described by Hermia for ultrafiltration (UF), nanofiltration (NF), and reverse osmosis (RO) filtration mode. Besides, a more detailed study on the use of resistance-in-series model for deadend filtration was done to investigate the fouling mechanisms involved in membrane filtration of AnPOME collected after microalgae treatment. The results showed that fouling of UF and NF membrane was mainly caused by cake layer formation and it was also supported by the analysis for resistance-in-series model. Whereas, fouling of RO membrane was dominated by concentration polarization.

막 오염 저항성이 우수한 분리막을 이용한 MBR 시스템의 실증화 기술개발 (Development of MBR System Commercialization Technology Using a Membrane with a Good Fouling Resistance)

  • 최정환;이정빈;김인철
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2008
  • 본 연구를 통하여 나노입자를 분리막의 표면에 함침시킴으로써 MBR 공정상에서 가장 큰 문제인 막 오염 문제를 해결하고자 하였고 실제 제작된 분리막의 현장적용 테스트를 거쳐서 개발된 분리막의 막 오염 저항성질을 확인하였다. 실험과정은 본 연구를 통한 티타니아가 함침된 분리막 제품과 국외의 타사 제품과의 장시간 현장적용 테스트를 통해 본 연구 제품의 우수성을 확인할 수 있었다. 본 연구 제품은 활성슬러지의 농도가 $7,000{\sim}13,000mg/L$의 고농도인 조건에서 $20{\sim}25L/m^2{\cdot}hr$의 투과유량을 꾸준하게 유지하는 것을 확인할 수 있었다. 이와 아울러 막과 막사이의 배치거리, 막과 산기관의 배치거리, 산기관의 홀 크기, 세정액의 농도 및 처리 방법 등에 따른 분리막의 투과유량의 거동 등을 살펴보았다. 즉 이들 부수적인 변수들의 최적화를 통해 분리막의 물성을 극대화할 수 있는 방법을 모색해 보았다.

불균질 이온교환막의 제조와 축전식 탈염에서의 탈염 성능 평가 (Preparation of Heterogeneous Ion Exchange Membranes and Evaluation of Desalination Performance in Capacitive Deionization)

  • 최재환;이주봉
    • 멤브레인
    • /
    • 제26권3호
    • /
    • pp.229-237
    • /
    • 2016
  • 막결합 축전식 탈염에 적용하기 위하여 불균질 이온교환막을 제조하였다. 이온교환수지 분말과 LLDPE (linear low density polyethylene) 혼합물을 압착시켜 불균질 이온교환막을 제조하였다. 제조한 막의 막 특성 분석과 MCDI 탈염실험을 실시하였다. 이온교환수지의 함량이 증가할수록 막의 전기저항은 감소하였고 함수율은 증가하였다. 그러나 막의 이온선택성을 나타내는 이온 수송수는 상업용 균질 막과 유사한 성능을 나타냈다. MCDI 탈염실험 결과 탈염량은 불균질 막의 높은 전기저항으로 인해 균질 막을 이용한 셀의 탈염량의 90% 수준을 나타냈다. 불균질 이온교환막은 균질 막에 비해 탈염성능은 다소 감소하였지만 제조가 간편하고 가격이 저렴하여 MCDI에 적용이 가능할 것으로 판단되었다.

회분식 막여과 시스템에서 약품역세가 여과성능에 미치는 영향 (The Effect of Chemical Backwash on Filtration Performance of Batch Membrane Filtration System)

  • 김관엽;이의종;권진섭;김형수
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.855-864
    • /
    • 2009
  • The main object of this work was to determine the influence of periodic chemical backwash on filtration resistance in membrane filtration system. In this work Hermia's models were used to investigate the fouling mechanisms involved in the microfiltration of $0.45{\mu}m$ filtered sewage feed. Batch microfiltration experiments were performed at transmembrane pressure 0.4 bar and different feed SCOD concentration (9~67 mgSCOD/L). The results showed that the best fit to experimental data corresponded to the intermediate blocking model followed by the standard and complete blocking model for all the experimental conditions tested. From the simulation results of filtration performance, it was found that in order to maintain sustainable operation of membrane filtration system, irreversible foulant component accumulated continuously on membrane surface and/or pore must be effectively removed. In addition, it was verified that periodic chemical backwash using NaOCl or NaOH effectively improved filtration performance of membrane.

유기염화물 수용액의 투과증발에 미치는 농도분극의 영향 (Effect of Concentration Polarization on The Pervaporation of Aqueous Chlorinated-Organic Solution)

  • 조민석;김승재;김진환
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.698-703
    • /
    • 1998
  • 실리콘고무 (polydimethylsiloxane, PDMS)막에 의한 trichloroethylene (TCE)과 chlorobenzene (CB)수용액의 투과증발실험을 수행하고 농도분극이 분리특성에 미치는 영향을 연구하였다. 경계층저항은 직렬저항모델을 사용하여 설명하였으며, 수용액으로부터 미량의 유기염화물을 제거하는 투과증발에서는 농도분극현상이 투과거동에 중요한 영향을 미치고 있음을 확인할 수 있었다. 같은 막두께에서, 막에 대한 친화력이나 선택투과성이 더 큰 TCE가 CB수용액보다 경계층저항의 영향이 더 크게 나타났다. 막두께가 증가할수록 경계층저항의 영향은 감소하고 막저항이 지배적이 되며, 겉보기분리계수는 증가하여 막의 고유분리계수에 가까워졌다.

  • PDF

Basalt Woven Fabric을 적용한 건축용 막재의 난연특성 (Flame Resistance Performance of Architectural Membranes Using Basalt Woven Fabric)

  • 김지현;송훈;신현욱
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.35-42
    • /
    • 2016
  • 막구조 건축물은 경량의 건축용 막재를 사용하므로 자유로운 곡면표현이 가능하고 시각적인 만족도가 높아 그 사용이 점차 확대되고 있다. 하지만 건축용 막재를 구성하는 직물이 화재에 취약하므로 용도에 적합하며 보다 높은 난연성능을 가지는 불연성 막재의 개발이 요구되고 있다. 따라서 본 연구에서는 단열성, 내열성, 불연성이 우수한 현무암섬유를 건축용 막재의 직포로 적용하고 PTFE 분산 수지를 함침 코팅하여 DSC/TGA 열분석, 강도특성, 방염 및 난연특성을 평가하였다. 또한, 일반적으로 사용되는 건축용 막재 중 성능이 가장 우수한 유리섬유 직포 막재와 난연특성을 비교하였으며 평가결과 현무암섬유 직포의 건축용 막재로서의 가능성을 확인할 수 있었다.