• 제목/요약/키워드: Membrane potential

검색결과 1,548건 처리시간 0.028초

Selectivity and structural integrity of a nanofiltration membrane for treatment of liquid waste containing uranium

  • Oliveira, Elizabeth E.M.;Barbosa, Celina C.R.;Afonso, Julio C.
    • Membrane and Water Treatment
    • /
    • 제3권4호
    • /
    • pp.231-242
    • /
    • 2012
  • The performance of a nanofiltration membrane for treatment of a low-level radioactive liquid waste was investigated through static and dynamic tests. The liquid waste ("carbonated water") was obtained during conversion of $UF_6$ to $UO_2$. In the static tests membrane samples were immersed in the waste for 24, 48 or 72 h. The transport properties of the samples (hydraulic permeability, permeate flow, selectivity) were evaluated before and after immersion in the waste. In the dynamic tests the waste was permeated in a permeation flow front system under 0.5 MPa, to determine the selectivity of NF membranes to uranium. The surface layer of the membrane was characterized by zeta potential, field emission microscopy, atomic force spectroscopy and infrared spectroscopy. The static test showed that the pore size distribution of the selective layer was altered, but the membrane surface charge was not significantly changed. 99% of uranium was rejected after the dynamic tests.

Applicability of low pressure membranes for wastewater treatment with cost study analyses

  • Maddah, Hisham A.;Chogle, Aman M.
    • Membrane and Water Treatment
    • /
    • 제6권6호
    • /
    • pp.477-488
    • /
    • 2015
  • This study demonstrates that low pressure membranes are the ideal choice for industrial and/or municipal wastewater treatment by showing some promising experimental results, understanding different membrane filtration models, studying the potential of membrane bioreactors (MBRs), considering ceramic membranes fabrication and illustrating the role of nanotechnology in membranes. Cost study calculations are included to determine the treatment cost as well as the initial cost of various membrane types. Results showed that integrated membranes are preferred over MBR in case of average capacities. However, higher capacity situations are the most economical choice for MBR. It is shown that the least treatment cost in MBR was about $0.13/m^3$. However, the $0.13/m^3$ is the theoretical cost which is very small compared to the actual average MBR treatment cost of $0.5/m^3$.

Antimicrobial Agents That Inhibit the Outer Membrane Assembly Machines of Gram-Negative Bacteria

  • Choi, Umji;Lee, Chang-Ro
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2019
  • Gram-negative pathogens, such as Klebsiella pneumoniae, Pseudomonas aeruginosa, and Acinetobacter baumannii, pose a serious threat to public health worldwide, due to high rates of antibiotic resistance and the lack of development of novel antimicrobial agents targeting Gram-negative bacteria. The outer membrane (OM) of Gram-negative bacteria is a unique architecture that acts as a potent permeability barrier against toxic molecules, such as antibiotics. The OM is composed of phospholipids, lipopolysaccharide (LPS), outer membrane ${\beta}-barrel$ proteins (OMP), and lipoproteins. These components are synthesized in the cytoplasm or in the inner membrane, and are then selectively transported to the OM by the specific transport machines, including the Lol, BAM, and Lpt pathways. In this review, we summarize recent studies on the assembly systems of OM components and analyze studies for the development of inhibitors that target these systems. These analyses show that OM assembly machines have the potential to be a novel attractive drug target of Gram-negative bacteria.

과염소산 이온선택성 PVC막 전극전위와 임피던스에 의한 전극특성 (Potential of Perchlorate Ion-Selective Electrode in PVC Membrane and Electrode Characteristics by ac Impedance)

  • 김경민;조경섭;강안수
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1998년도 춘계 총회 및 학술발표회
    • /
    • pp.49-52
    • /
    • 1998
  • 1. 서론 : 화약이나 고체 충진제, 고체로\ulcorner 추진제의 산화제, slurry blasting agent 및 동물사료의 식품첨가제로 사용되고 있는 과염소산은 발화나 폭발성이 매우 강한 산화제로 정확한 순도를 측정하는 것은 중요하다. 용량분석법과 중량분석법에 비교하여 조작이 간단하고 편리한 과염소산이온의 농도를 직접 측정할 수 있는 PVC막 전극에 대한 많은 연구가 진행되고 있다. (생략)

  • PDF

Bipolar Membranes and Their Applications

  • Strathmann, H.
    • 멤브레인
    • /
    • 제11권3호
    • /
    • pp.97-108
    • /
    • 2001
  • Bipolar membranes have gained increasing interest as a tool for an efficient production of acids and bases from the corresponding salts. A large number of potential applications have been identified in the chemical and biochemical industry have been identified and evaluated on a laboratory scale. In spite of extensive research efforts and laboratory and pilot plat test, there are hardly any large-scale commercial plants. In this paper the basic concept of the electrodialytic water dissociation with bipolar membranes are briefly reviewed. The limitations of today\`s bipolar membranes are indicated. Selected examples of successful applications of the bipolar membrane technology are discussed.

  • PDF

Analogs of Periplanetasin-4 Exhibit Deteriorated Membrane-Targeted Action

  • Lee, Heejeong;Hwang, Jae Sam;Lee, Dong Gun
    • Journal of Microbiology and Biotechnology
    • /
    • 제30권3호
    • /
    • pp.382-390
    • /
    • 2020
  • Periplanetasin-4 is an antimicrobial peptide with 13 amino acids identified in cockroaches. It has been reported to induce fungal cell death by apoptosis and membrane-targeted action. Analogs were designed by substituting arginine residues to modify the electrostatic and hydrophobic interactions accordingly and explore the effect of periplanetasin-4 through the increase of net charge and the decrease of hydrophobicity. The analogs showed lower activity than periplanetasin-4 against gram-positive and gram-negative bacteria. Similar to periplanetasin-4, the analogs exhibited slight hemolytic activity against human erythrocytes. Membrane studies, including determination of changes in membrane potential and permeability, and fluidity assays, revealed that the analogs disrupt less membrane integrity compared to periplanetasin-4. Likewise, when the analogs were treated to the artificial membrane model, the passage of molecules bigger than FD4 was difficult. In conclusion, arginine substitution could not maintain the membrane disruption ability of periplanetasin-4. The results indicated that the attenuation of hydrophobic interactions with the plasma membrane caused a reduction in the accumulation of the analogs on the membrane before the formation of electrostatic interactions. Our findings will assist in the further development of antimicrobial peptides for clinical use.

고온형 고분자 전해질막 연료전지(HT-PEMFC) 구동환경에 따른 탄소 담지체 부식 평가 (Effect of operating conditions on carbon corrosion in High temperature polymer electrolyte membrane fuel cells (HT-PEMFCs))

  • 이진희;김한성
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.89.1-89.1
    • /
    • 2011
  • The influence of potential and humidity on the electrochemical carbon corrosion in high temperature polymer electrolyte membrane fuel cells(HT-PEMFCs) is investigated by measuring $CO_2$ emission at different potentials for 30 min using on-line mass spectrometry. These results are compared with low tempterature polymer electrolyte membrane fuel cells(LT-PEMFCs) operated at lower temperature and higher humidity condition. Although the HT-PEMFC is operated at non humidified condition, the emitted $CO_2$ in the condition of HT-PEMFC is more than LT-PEMFC at the same potential in carbon corrosion test. Thus, carbon corrosion shows a stronger positive correlation with the cell temperature. In addition, the presence of a little amount of water activate electrochemical carbon corrosion considerably in HT-PEMFC. With increased carbon corrosion, changes in fuel cell electrochemical characteristics become more noticeable and thereby indicate that such corrosion considerably affects fuel cell durability.

  • PDF

Effects of Hesperidin Are Not Associated with Changes in Basal Synaptic Transmission, Theta-burst LTP, and Membrane Excitability in CA1 Neuron

  • Baek, Jin-Hee;Kim, Jae-Ick;Kaang, Bong-Kiun
    • Animal cells and systems
    • /
    • 제13권4호
    • /
    • pp.357-362
    • /
    • 2009
  • Hesperidin, the most abundant polyphenolic compound found in citrus fruits, has been known to possess neuroprotective, sedative, and anticonvulsive effects on the nervous system. In a recent electrophysiological study, it was reported that hesperidin induced biphasic change in population spike amplitude in hippocampal CA1 neurons in response to both single spike stimuli and theta-burst stimulation depending on its concentration. However, the precise mechanism by which hesperidin acts on neuronal functions has not been fully elucidated. Here, using whole-cell patch-clamp recording, we revealed that hesperidin did not affect excitatory synaptic activities such as basal synaptic transmission and theta-burst LTP. Moreover, in a current injection experiment, spike number, resting membrane potential and action potential threshold also remained unchanged. Taken together, these results indicate that the effects of hesperidin on the neuronal functions such as spiking activity might not be attributable to either modification of excitatory synaptic transmissions or changes in membrane excitability in hippocampal CA1 neuron.

A small-scale membrane electro-dialyser for domestic use

  • Chaalal, Omar;Hossain, Md.M.
    • Membrane and Water Treatment
    • /
    • 제6권1호
    • /
    • pp.43-52
    • /
    • 2015
  • A small-scale electro-dialysis system was constructed for domestic use. It is composed of six compartments in which five special polystyrene ionic membranes are housed. A series of experiments on the transport of sodium and chloride ions through polystyrene membranes was performed and the effects of electric current and voltage on the pH of water were investigated. This electrodialyser could reduce the NaCl content to an acceptable level (5307 mg/L) when water containing 9945 mg/L of sodium chloride is fed to the electrodialyser. The reduction was by the action of direct current 60 mA/100 mA when a 15 V / 20 V potential is maintained across the membrane. The results showed that the pH of the treated water attained a value in the range of 7-8, with the chloride concentration of 5307 mg/L when the voltage was in the range of 20 volts. This was achieved when two of the small-scale electro-dialysers were placed in series and the solutions from the respective compartments were mixed. This is considered useful because this complies to the requirement of drinking water standard both in terms of chloride and pH. Therefore, this type electrodialyserhas the potential for domestic uses in isolated houses where potable water supply is not available.