• 제목/요약/키워드: Membrane fouling

검색결과 651건 처리시간 0.026초

하수방류수 재이용을 위한 Birm filter + UF 적용시 용도별 사용 가능성 및 막오염 특성 (Possible Uses of Reclaimed Wastewater Effluent Treated Using Birm Filtration Along UF, and Analysis on Membrane Fouling)

  • 정진희;이승철;성낙창;최영익
    • 한국환경과학회지
    • /
    • 제25권11호
    • /
    • pp.1467-1474
    • /
    • 2016
  • In response to the water shortage problem, continued attempts are being made to secure consistent and reliable water sources. Among various solutions to this problem, wastewater effluent is an easy way to secure the necessary supply, since its annual output is consistent. Furthermore, wastewater effluent has the advantage of being able to serve various purposes, such as cleaning, sprinkling, landscaping, river management, irrigation, and industrial applications. Therefore, this study presents the possible use of reclaimed industrial wastewater treated with Birm filters and a UF membrane, along with an analysis on membrane fouling. The preprocessing stage, part of the reclamation process, used Birm filters to minimize membrane fouling. Since this study did not consider heavy metal levels in the treated water, the analyses did not include the criterion for irrigation water quality. However, the wastewater reclaimed by using Birm filters and a UF membrane met every other requirement for reclaimed water quality standards. This indicated that the treated water could be used for cleaning, channel flow for maintenance, recreational purposes, and industrial applications. The analysis on the fouling of the Birm filter and UF membrane required the study of the composition and recovery rate of the membrane. According to SEM and EDX analyses of the UF membrane, carbon and oxygen ion composition amounted to approximately 57%, whereas inorganic matter was not detected. Furthermore, the difference in the recovery rates of the distressed membrane between acidic and alkaline cleaning was more than ~78%, which indicated that organic rather than inorganic matter contributed to membrane fouling.

막 오염 저항성이 우수한 분리막을 이용한 MBR 시스템의 실증화 기술개발 (Development of MBR System Commercialization Technology Using a Membrane with a Good Fouling Resistance)

  • 최정환;이정빈;김인철
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.35-43
    • /
    • 2008
  • 본 연구를 통하여 나노입자를 분리막의 표면에 함침시킴으로써 MBR 공정상에서 가장 큰 문제인 막 오염 문제를 해결하고자 하였고 실제 제작된 분리막의 현장적용 테스트를 거쳐서 개발된 분리막의 막 오염 저항성질을 확인하였다. 실험과정은 본 연구를 통한 티타니아가 함침된 분리막 제품과 국외의 타사 제품과의 장시간 현장적용 테스트를 통해 본 연구 제품의 우수성을 확인할 수 있었다. 본 연구 제품은 활성슬러지의 농도가 $7,000{\sim}13,000mg/L$의 고농도인 조건에서 $20{\sim}25L/m^2{\cdot}hr$의 투과유량을 꾸준하게 유지하는 것을 확인할 수 있었다. 이와 아울러 막과 막사이의 배치거리, 막과 산기관의 배치거리, 산기관의 홀 크기, 세정액의 농도 및 처리 방법 등에 따른 분리막의 투과유량의 거동 등을 살펴보았다. 즉 이들 부수적인 변수들의 최적화를 통해 분리막의 물성을 극대화할 수 있는 방법을 모색해 보았다.

분리공정을 위한 패턴화 멤브레인 최근 연구 동향 (Recent Progress in Patterned Membranes for Membrane-Based Separation Process)

  • 헤인 탯 엉;라즈쿠마 파텔
    • 멤브레인
    • /
    • 제31권3호
    • /
    • pp.170-183
    • /
    • 2021
  • 파울링은 멤브레인 성질의 효과를 저해한다는 점에서 큰 문제다. 멤브레인의 표면적인 특성에 파울링의 영향이 감소하는 문제를 해결하기 위해 다양하고 기발한 멤브레인의 패턴화가 제시되었다. 패턴화된 멤브레인의 진행 과정과 멤브레인의 파울링 효과의 분리 과정을 이 글을 통해 짚어보려 한다. 패턴화된 멤브레인의 효과를 최대한 활용하는 다양한 분리 과정을 분석해야 하는데 바로 나노여과, 역삼투, 미세여과, 한외여과, 투과증발이다. 이러한 분리 과정들을 사용하면 파울링 효과를 줄이는데 큰 효과가 있다는 점이 증명되었다. 또한, 패턴화된 멤브레인에 이로운 요소도 더해진다. 각각의 패턴화된 멤브레인과 분리 과정들은 플럭스, 염 제거율, 친수성 등에 대한 임계값을 구하는데 주목할 만한 결과가 나왔지만, 아직 파악되지 않은 부분을 확인할 필요도 있다. 본 총설에서는 분리공정을 위한 패턴화된 멤브레인의 효과에 대해 논의할 것이다.

Performance of a submerged membrane bioreactor for wastewater mimicking fish meal processing effluent

  • Lopez, Guadalupe;Almendariz, Francisco J.;Heran, Marc;Lesage, Geoffroy;Perez, Sergio
    • Membrane and Water Treatment
    • /
    • 제9권4호
    • /
    • pp.263-271
    • /
    • 2018
  • The objective of this work was to analyze organic matter removal, nitrification, biomass growth and membrane fouling in a submerged flat-sheet membrane bioreactor, fed with synthetic wastewater, of similar composition to the effluents generated in a fish meal industry. After biomass acclimatization with saline conditions of 12 gNaCl/L and COD/N ratio of 15 in the bioreactor, results showed that the organic matter removal was higher than 90%, for all organic loading rates (0.8, 1, 1.33 and $2gCOD/L{\cdot}d$) and nitrogen loading rates (0.053, 0.067, 0.089 and $0.133gN/L{\cdot}d$) tested during the study. However, nitrification was only carried out with the lowest OLR ($0.8gCOD/L{\cdot}d$) and NLR ($0.053gN/L{\cdot}d$). An excessive concentration of organic matter in the wastewater appears as a limiting factor to this process' operating conditions, where nitrification values of 65% were reached, including nitrogen assimilation to produce biomass. The analysis of membrane fouling showed that the bio-cake formation at the membrane surface is the most impacting mechanism responsible of this phenomenon and it was demonstrated that organic and nitrogen loading rates variations affected membrane fouling rate.

역삼투막을 이용한 음식폐기물 액비의 농축 (Accumulation of Food Wastes Liquid Fertilizer using Reverse Osmosis Membrane System)

  • 차기철;황명구;이명규;태민호
    • 한국물환경학회지
    • /
    • 제18권2호
    • /
    • pp.159-168
    • /
    • 2002
  • A lab-scale Reverse Osmosis(RO) membrane reactor was installed to investigate the membrane permeability, characteristics of membrane fouling at each conditions, and performance of elimination at different trans-membrane pressure(TMP) in the liquid fertilizer accumulated system. Experimental setup was divided to three different TMP conditions. As a result of experiment, permeability of RO membrane was proportional to the increase of TMP and temperature. After experiment was completed, two types chemical cleaning(remove the organic foulant and inorganic foulant) was done, and recover rate of permeability was each 99.8, 99.7 and 99.7%, respectively. From this experimental data, membrane fouling could be determined that the most of it was recoverable in this system, and major reason of fouling was concentration polarization. Elimination rate of solute substance in the liquid fertilizer indicated very stable(above 99%), except ammonia nitrogen, and the most stable elimination rate was investigated at the highest TMP condition (Run 3).

Investigation of influence of temperature and solid retention time on membrane fouling in MBR

  • Mirzavandi, Atoosa;Hazrati, Hossein;Ebrahimi, Sirous
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.179-189
    • /
    • 2019
  • This study aimed to investigate the effect of temperature and solid retention time (SRT) on membrane fouling in a membrane bioreactors (MBRs). For this purpose, a lab-scale submerged MBR system was used. This system operated at two SRTs of 15 and 5 days, three various temperatures (20, 25 and $30^{\circ}C$) and hydraulic retention time (HRT) of 8 h. The results indicated that decreased the cake layer resistance and increased particles size of foulant due to increasing temperature and SRT. Fourier transform infrared (FTIR) analysis show that the cake layer formed on the membrane surface, contained high levels of proteins and especially polysaccharides in extracellular polymeric substances (EPS) but absorbance intensity of EPS functional groups decreased with temperature and SRT. EEM analysis showed that the peak on the range of Ex/Em=220-240/350-400 in SRT of 15 and temperature of $30^{\circ}C$ indicates the presence of fulvic acid in the cake. In addition, as the temperature rise from 20 to $30^{\circ}C$, concentration of soluble microbial products (SMP) increased and COD removal reached 89%. Furthermore, the rate of membrane fouling was found to increase with decreasing temperature and SRT.

Cleaning agents efficiency in cleaning of polymeric and ceramic membranes fouled by natural organic matter

  • Urbanowska, Agnieszka;Kabsch-Korbutowicz, Malgorzata
    • Membrane and Water Treatment
    • /
    • 제7권1호
    • /
    • pp.1-10
    • /
    • 2016
  • Ultrafiltration is known to be one of the most commonly applied techniques in water treatment. Membrane fouling is the main limiting factor in terms of process efficiency and restricting it to the manageable degree is crucial. Natural organic matter is often found to be a major foulant in surface waters. Among many known fouling prevention techniques, the membrane chemical cleaning is widely employed. This study focuses on evaluating the cleaning efficiency of polymeric and ceramic membranes with the use of various chemicals. The influence of cleaning agent type and its concentration, membrane material and its MWCO, and cleaning process duration on the recovery of membrane flux was analyzed. Results have shown that, regardless of membrane type and MWCO, the most effective cleaning agent was NaOH.

하수처리수 재이용을 위한 RO 공정의 타당성 및 막오염 평가 (Evaluation of RO Process Feasibility and Membrane Fouling for Wastewater Reuse)

  • 홍기웅;이상엽;김창우;부찬희;박명균;안호철;홍승관
    • 한국물환경학회지
    • /
    • 제26권2호
    • /
    • pp.289-296
    • /
    • 2010
  • The purpose of this study is to evaluate various pre-treatment methods and proprieties of water quality for wastewater reuse using reverse osmosis (RO) processes. Secondary effluents were sampled from wastewater treatment plants and lab scale pre-treatments and RO filtration test were conducted systematically. Specifically, different types of pre-treatments, such as coagulation, microfiltration and ultrafiltration, were employed to evaluate the removal efficiency of particle and organic matters which may affect the membrane fouling rate. RO process was later added to eliminate trace amounts of remaining organic matters and salt from the raw water for wastewater reclamation. The permeate through the RO process satisfied water quality regulations for industrial water uses. The experimental results showed that the initial fouling tendency differed not only by the feed water properties but also by the membrane characteristics. Membrane fouling was greater for the membranes with large surface roughness, regardless of the hydrophobicity and zeta potentials. Thus both careful consideration of pre-treatment options and proper selection of RO membrane are of paramount importance for an efficient operation of wastewater treatment.

침지식 중공사 정밀여과 분리막에서 무기혼합입자 여과에 대한 단계별 공기세정의 영향 (Effect of Step-aeration on Inorganic Particle Mixtures Filtration in a Submerged Hollow Fiber Microfiltration Membrane)

  • 최영근;김현철;노수홍
    • 멤브레인
    • /
    • 제25권3호
    • /
    • pp.256-267
    • /
    • 2015
  • 침지식분리막 오염을 최소화하기 위한 두 가지 공기세정방식을 비교하였다. 연속적인 공기세정과 단계별 공기량을 증가시키는 방식을 연구하였다. 15분의 여과 중에 세정공기의 증가는 5분마다 단계별로 공기량을 증가시켜주었다. 모의 여과 원수에 분말활성탄을 10 g/L 이하 그리고 카올린은 20 g/L 이하로 준비하였으며, 플러스는 80 LMH로 하였다. 단계별 공기세정방식은 연속적인 공기세정 방식보다 분리막 오염억제에 효과적이었다. 추가적으로 주입된 응집제는 분리막 오염저감을 보다 향상시켰다. 연속적인 공기세정의 오염현상은 공경막힘과 분리막 표면에 지속적인 입자의 축적에 기인하였다.

PVDF막 표면에 폴리비닐알코올 코팅을 통한 분리막의 투과특성 및 막오염 제어 (Membrane Permeation Characteristics and Fouling Control through the Coating of Poly(vinyl alcohol) on PVDF Membrane Surface)

  • 장한나;김인철;이용택
    • 멤브레인
    • /
    • 제24권4호
    • /
    • pp.276-284
    • /
    • 2014
  • 본 연구에서는 소수성 PVDF막 표면에 중성 친수성 고분자인 Poly(vinyl alcohol) (PVA)를 코팅한 후 순수 투과도를 측정하고 대표적인 단백질 오염물질인 bovin serum albumin (BSA)에 대하여 파울링 실험을 수행하였다. BSA 용액 20 ppm 조건에서 파울링 실험을 수행한 결과, 코팅 전 막에 비하여 순수 투과도는 감소하였지만 내오염성은 현저히 증가됨을 알 수 있었다. 코팅된 PVA의 분자량이 커질수록 순수 투과도는 감소하였으나, 내오염성이 증가하는 경향을 보였다. 또한, 코팅된 PVA의 농도가 높아질수록 순수 투과도는 감소하였고, 내오염성이 증가하였다. 이는 접촉각과 AFM 측정 결과와 관련하여 코팅 후 막 표면에 친수성의 증가와 거칠기가 감소했기 때문으로 여겨진다.