• Title/Summary/Keyword: Membrane contamination

Search Result 110, Processing Time 0.025 seconds

Preparation and Radionuclide Detection Analysis of Inorganic Fluor Impregnated Double-layered Membranes (이중구조 무기형광 함침막 제조 및 방사성핵종 탐지능력의 분석)

  • 이근우;서범경;박진호;남석태;한명진
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.240-246
    • /
    • 2002
  • New polysulfone scintillation proximity membranes were prepared by impregnating Cerium Activated Yttrium Silicate (CAYS), an inorganic fluor, in a membrane structure. The membranes were applied to detect the radionuclide contamination directly without the aid of a scintillation cocktail. The preparation of membranes was divided into two processes. A supporting polymer film was made of casting solutions consisting of polysulfone and solvent, their cast film being solidified by vacuum evaporation. CAYS-dispersed polymer solutions were cast over the first, solidified polymer films and coagulated either by evaporating solvent or by exchanging solvent in the solution with nonsolvent in a coagulation bath. The prepared membranes had two distinguished, but tight1y attached, double layers: one is the supporting layer of dense polymer film and the other the detecting layer consisting of CAYS and polymer. The radionuclide counting results revealed that the prepared membranes were efficient to monitor radioactivity contamination with reliable counting ability.

Numerical study of effect of membrane properties on long-cycle performance of vanadium redox flow batteries

  • Wei, Zi;Siddique, N.A.;Liu, Dong;Sakri, Shambhavi;Liu, Fuqiang
    • Advances in Energy Research
    • /
    • v.4 no.4
    • /
    • pp.285-297
    • /
    • 2016
  • Fundamental understanding of vanadium ion transport and the detrimental effects of cross-contamination on vanadium redox flow battery (VRFB) performance is critical for developing low-cost, robust, and highly selective proton-conducting membranes for VRFBs. The objective of this work is to examine the effect of conductivity and diffusivity, two key membrane parameters, on long-cycle performance of a VRFB at different operating conditions using a transient 2D multi-component model. This single-channel model combines the transport of vanadium ions, chemical reactions between permeated ions, and electrochemical reactions. It has been discovered that membrane selecting criterion for long cycles depends critically on current density and operating voltage range of the cell. The conducted simulation work is also designed to study the synergistic effects of the membrane properties on dynamics of VRFBs as well as to provide general guidelines for future membrane material development.

Removal of safranin from aqueous solution through liquid emulsion membrane

  • Lohiya, Roshni;Goyal, Arihant;Dohare, Rajeev Kumar;Agarwal, Madhu;Upadhyaya, Sushant
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.373-379
    • /
    • 2019
  • One of the real issues of the recent years is water contamination because of harmful synthetic dyes. Liquid Membranes (LM) resemble a promising alternative to the current separation processes, demonstrating various points of interest as far as effectiveness, selectivity, and operational expenses. The improvement of various Liquid Membranes designs has been a matter of examination by few researchers, particularly for the expulsion of dyes from aqueous solutions. The choice of organic surfactants plays an essential role in the efficiency of the dye removal. In LM design, the most significant step towards productivity is the decision of the surfactant type and its concentration. Liquid emulsion membrane (LEM) was used to remove safranin from aqueous solutions in which the emulsion was made with the help of D2EHPA as carrier, kerosene was used as a diluent and Span 80 (Sorbiton monooleate) was used as an emulsifying agent or surfactant. Various sorts of internal stages were utilized, to be specific sulphuric acid and sodium hydroxide. The impact of parameters influencing extraction efficiency such as pH of feed solution, concentrations of surfactant and emulsifying agent in membrane phase, volume ratio of internal phase to membrane phase, internal phase concentration, agitation speed and time of extraction were analyzed.

Heavy metals removal from aqueous solution through micellar enhanced ultrafiltration: A review

  • Yaqub, Muhammad;Lee, Seung Hwan
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.363-375
    • /
    • 2019
  • Micellar-enhanced ultrafiltration (MEUF) is a surfactant-based separation technique and has been investigated for the removal of heavy metals from wastewater. The performance of heavy metals removal from wastewater through MEUF relies on membrane characteristics, surfactant properties, various operational parameters including operating pressure, surfactant and heavy metal concentration, pH of the solution, temperature, and presence of dissolved solutes and salts. This study presents an overview of literature related to MEUF with respect to the all significant parameters including membranes, surfactants, operating conditions and MEUF hybrid processes. Moreover, this study illustrates that MEUF is an adaptable technique in various applications. Nowadays water contamination caused by heavy metals has become a serious concern around the globe. MEUF is a significant separation technique in wastewater treatment that should be acknowledged, for the reason that removal of heavy metals contamination even at lower concentrations becomes achievable, which is evidently made known in the presented review. Hybrid processes presented the better results as compared to MEUF. Future studies are required to continue the experimental work with various combinations of surfactant and heavy metals, and to investigate for the treatment of concentrated solutions, as well as for real industrial wastewater.

Development of Remote Monitoring System for groundwater purifier apparatus for community wells (마을 공동 우물용 지하수 정수 장치의 원격 모니터링 시스템 개발)

  • Kim, Dong-Jin;park, Sang-heup;Lee, Hong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.224-231
    • /
    • 2019
  • Recently, the pollution of groundwater has become serious. In particular, the contamination of groundwater near livestock farms is becoming increasingly severe and it is difficult to drink with drinking water. In this paper, a groundwater purifier apparatus that can be installed in a community well was designed. The designed groundwater purifier apparatus enables a RO membrane filter and UV sterilization to remove pollutants, such as heavy metals, bacteria, and organic compounds. In addition, electrical conductivity, pressure, and flow sensors were added for remote monitoring. Remote monitoring of the system can determine the level of fouling and contamination of RO membrane filters through pressure and flow sensor data, and can record changes in the contamination and condition of groundwater through the electrical conductivity of the feed water. The designed groundwater purifier apparatus was installed at a farmhouse and remote monitoring. The result after 15 days of operating a groundwater purifier apparatus and analyzing the monitoring data revealed an average permeate water flow rate of 2.67L/min and an average water pressure of 7.09kgf/㎠, indicating that the RO Membrane filtered without fouling and clogging. The average electrical conductivity was 796.6 S/㎠ of the feed water and 55.6 S/㎠ of permeate water, which is similar to that of general tap water. Through this, it was confirmed that no pollutant occurred in the surroundings. Therefore, the designed groundwater purifier apparatus can confirm the replacement time of the RO membrane filter in advance through remote monitoring, and check the pollution state of the groundwater.

Minimization of Asymmetry Potential in ETH 129-Based Calcium-Selective Membrane Electrodes

  • 박성배;정사라;차근식;김해동
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.11
    • /
    • pp.1033-1037
    • /
    • 1995
  • PVC-based calcium-selective electrodes doped with ETH 129 usually suffer from a shift in the standard potential when they are in contact with protein-containing solutions (e.g. blood serum) after being calibrated with aqueous standards. The shift is due to the development of asymmetry potential in inherently symmetric PVC membranes through the contamination of outer membrane surface by proteins in the biological samples. Membranes prepared with polyurethane showed much reduced shifts in terms of standard potential. This study was performed with a flow-injection system following a protocol designed to observe minor shifts in baseline potential. Other electrochemical properties of the system, including selectivity and response slope, were similar to those obtained with regular PVC-based ones. PVC-based calcium selective membrane electrodes, doped with commonly used ETH 1001, were also tested to compare their electrochemical performances.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

In Vitro Study Of Salivary Bacterial Adherence On e-PTFE Membrane According To Periodontal Status. (치주조직 상태에 따른 e-PTFE막 부착에 관한 연구)

  • Ju, Jae-Ig;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.117-132
    • /
    • 1996
  • The purpose of this study was to evaluate the bacterial adherence on e-PTFE membrane immersed in whole saliva from subjects with different periodontal status. Experiment involved 3 subject groups: 5 persons with healthy periodontium(probing depth below 3mm and no signs of gingival inflammation including bleeding on probing), 10 patients with gingivitis(probing depth below 3mm and apparent signs of gingival inflammation), and 10 patients with advanced periodontitis(probing depth over 7mm and apparent signs of gingival inflammation). Each disease group was included before and after scaling and root planing treatment. After obtaining whole saliva from each subject, e-PTFE membrane(Gore-Tex periodontal membrane : $GTPM^{(R)}$, W.L. Gore & Associates, Flagstaff, USA) specimens were immersed at room temperature in the saliva aliqouts for 1, 3, 7 days. The weight between pre - and post - immersion in saliva was measured with the analytical balance and the difference was recorded. The specimens were processed for SEM observation. The bacterial adherence on the membrane specimens was evaluated using the scanning electron microscope images. The obtained results were as follows : 1. There was no difference in the weight of bacteria adherent to e-PTFE membrane specimens according to the periodontal status and the immersion periods. 2. As the exposure time to saliva increased, the bacterial adherence to the membrane specimen significantly increased in all groups(P<0.005). 3. As the severity of periodontal disease increased, the bacterial adherence to the membrane specimens significantly increased(p<0.001). 4. After scaling and root planing, the bacterial adherence to the membrane specimens significantly decreased in gingivitis and periodontitis patient group(P<0.001). These results suggest that bacterial contamination on exposed barrier membrane surface be reduced through improvement of periodontal status and oral health environment before and after GTR procedure for the successful outcome.

  • PDF

Characteristics of Microbial Fuel Cells Using Livestock Waste and Degradation of MEA (가축 분뇨를 이용한 미생물 연료전지의 특성 및 MEA 열화)

  • Kim, Young-Sook;Chu, Cheun-Ho;Jeong, Jae-Jin;Ahn, Myung-Won;Na, Il-Chai;Lee, Jeong-Hoon;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.52 no.2
    • /
    • pp.175-181
    • /
    • 2014
  • Microbial fuel cells (MFC) were operated with livestock wastes and PEMFC (Proton Exchange Membrane Fuel Cells) MEA (Membrane and Electrode Assembly). OCV of MFC with mixtures of microbial was higher than that of MFC with single microbial. MFC using pig wastes showed highest OCV (540 mV) among cow waste, chicken waste and duck waste. And the power density of MFC using pig waste was $963mW/m^2$. Contamination of MEA with $Na^{2+}$, $Ca^{2+}$, $K^+$ ion and impurities was the one cause for low performance of MFC during operation.

Effects of F/M ratio on the EPS production and fouling at MBR (MBR에서 F/M비가 EPS 생성 및 fouling에 미치는 영향)

  • Kim, Yun-Ji;Choi, Yun-Jeong;Hwang, Sun-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.3
    • /
    • pp.197-204
    • /
    • 2021
  • In MBR, extracellular polymeric substance (EPS) is known as an important factor of fouling; soluble EPS (sEPS) affects internal contamination of membrane, and bound EPS (bEPS) affects the formation of the cake layer. The production of EPS changes according to the composition of influent, which affects fouling characteristics. Therefore, in this study, the effects of the F/M ratio on the sEPS concentration, bEPS content, and fouling were evaluated. The effects of F/M ratio on the amount and composition of EPS were confirmed by setting conditions that were very low or higher than the general F/M ratio of MBR, and the fouling occurrence characteristics were evaluated by filtration resistance distribution. As a result, it was found that the sEPS increased significantly with the increase of the F/M ratio. When the substrate was depleted, bEPS content decreased because bEPS was hydrolyzed into BAP and seemed to be used as a substrate. In contrast, when the substrate is sufficient, UAP (utilization-associated products) was rapidly generated in proportion with the consumption of the substrate. UAP has a relatively higher Protein/Carbohydrate ratio (P/C ratio) than BAP, and this means, it has a higher adhesive force to the membrane surface. As a result, UAP seems like causing fouling rather than BAP (biomass-associated products). Therefore, Rf (Resistance of internal contamination) increased rapidly with the increase of UAP, and Rc (Resistance of cake layer) increased with the accumulation of bEPS in proportion, and as a result, the fouling interval was shortened. According to this study, a high F/M ratio leads to an increment in UAP generation and accumulation of bEPS, and by these UAP and bEPS, membrane fouling is promoted.