유암의 방사선치료방법에 대한 고찰 (Radiotherapy Techniques for Breast Cancer)

  • 김정만;홍영락;박흥득;정호용
    • 대한방사선치료학회지
    • /
    • 제1권1호
    • /
    • pp.79-83
    • /
    • 1985
  • Carcinoma of the breast has been treated by surgery followed by irradiation of the chest wall and regional lymphatics treatment planning of the breast cancer is required that lung must be spared as much as possible. However megavoltage irradiation of the internal mammary chain results in high dose to underlying heart, esophagus and spinal cord. Electron beam can be used for the irradiation of the internal mammary chain instead of megavoltage beam. We studied dose distribution of single anterior electron field, compared with traditional treatment methods. 12 and 15MeV electron beam with bolus has good dose distribution to spare underlying lung tissue and other organs.

  • PDF

방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교 (Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;정회원;권경태;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.99-105
    • /
    • 2016
  • 잡음전력스펙트럼 (noise power spectrum, NPS)는 noise 진폭의 측정과 균일한 방사선 영역으로부터 획득된 영상의 품질에 가장 일반적인 방법 중 하나이다. 이 연구의 목적은 megavoltage X-ray 에너지를 사용하여 다른 잡음 전력스펙트럼 방법론들을 비교하는 것이다. 진단 영역에서의 잡음전력스펙트럼 평가 방법들은 국제 전기 규격 international electro-technical commission(IEC 62220-1) 기준을 사용하여 치료 영역에 적용되었다. 우리가 사용한 전자포털영상장치(electronic portal imaging device, EPID)는 Varian TrueBeam$^{TM}$, Siemens BEAMVIEW$^{PLUS}$, Elekta iViewGT 그리고 Varian Clinac$^R$ iX aS1000이었다. 잡음전력스펙트럼의 관심영역을 측정하기 위해, 우리는 겹침 (overlapping), 비겹침 (non-overlapping), 평탄도 (flatness), 반음영 (penumbra) 4가지 인자를 사용하였다. 결과적으로는 Siemens BEAMVIEW$^{PLUS}$, Varian TrueBeam$^{TM}$ flattening filter, Varian Clinac$^R$ iX aS1000, Varian TrueBeam$^{TM}$ flattening filter free에서의 잡음 (noise) 분포는 기존의 첫번째, 두번째, 세번째 실험방법보다는 Elekta iViewGT보다 현격하게 높은 noise 분포가 나타남을 알 수 있다. 이번 연구는 다양한 인자들이 잡음전력스펙트럼의 megavoltage imaging (MVI)영상에서 MVI영역에서 잡음전력 스펙트럼의 기준의 방법론으로 사용되어질 수 있다는 것을 보여주었다.

6 MV 광자선치료에서 안구차폐기구의 제작과 선량분포 측정 (Dose Distribution for Eye Shielding Block In 6 MV Photon Beam Therapy)

  • 이경자
    • Radiation Oncology Journal
    • /
    • 제10권2호
    • /
    • pp.155-161
    • /
    • 1992
  • 눈의 수정체는 방사선에 매우 예민한 장기이며 비교적 적은 선량에서도 백내장의 원인이 될 수 있다. 그러므로 두경부암의 방사선치료에서 수정체를 최대한 차폐하면서 병소에 집중 조사하는 방법이 개발되어야 한다. 저자는 안구의 표면에서 0.5 cm 깊이에 위치하며 폭 1 cm인 눈의 수정체를 최대한 차폐하면서 주위 병소를 치료하기 위하여 원자번호가 높은 차폐물질을 이용하였으며 최적조사조건은 측정실험을 통하여 결정하였고 이를 임상치료에 응용하였다. 수정체의 차폐기구는 제작하기 쉽고 차폐효과가 큰 혼합금속(Cerrobend)이 적당하였으며 두께 7.5 cm와 직경 1 cm의 원뿔기둥모양이 가장 이상적이었다. 차폐기둥의 밑면과 표면과의 거리가 l0 cm일 때 수정체에 가장 적은 선량이 부여되며 병소에는 비교적 많은 선량이 부여된다. 이때 각막(Cornea, 1 mm), 수정체 (Eye Lens, 5 mm), 망막(Retina, 25 mm) 및 병소(Tumor, 50 mm 이상)의 선량은 차폐물이 없을 때와 비교하여 각각 $10.0\%$, $15.2\%$, $21.5\%$$23.2\%$로 측정되었다.

  • PDF

Photon Beam Commissioning for Monte Carlo Dose Calculation

  • Cho, Byung-Chul;Park, Hee-Chul;Hoonsik Bae
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.106-108
    • /
    • 2002
  • Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. Monte Carlo treatment planning requires accurate beam information as input to generate accurate dose distributions. The procedures to obtain this accurate beam information are called "commissioning", which includes accelerator head modeling. In this study, we would like to investigate how much accurately Monte Carlo based dose calculations can predict the measured beam data in various conditions. The Siemens 6MV photon beam and the BEAM Monte Carlo code were used. The comparisons including the percentage depth doses and off-axis profiles of open fields and wedges, output factors will be presented.

  • PDF

Megavoltage Cone-beam CT 영상의 변환을 이용한 변환 영상 정합의 정확도 향상 (Enhancement of the Deformable Image Registration Accuracy Using Image Modification of MV CBCT)

  • 김민주;장지나;박소현;김태호;강영남;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제22권1호
    • /
    • pp.28-34
    • /
    • 2011
  • 적응 방사선 치료(Adaptive Radiation Therapy, ART)를 실행하기 위한 고도의 정확성을 갖는 변형 영상 정합 방법은 필수이다. 본 연구의 목적은 Megavoltage cone-beam CT (MV CBCT)영상의 Intensity 변화를 통한 영상 정합의 정확성의 향상이다. Intensity 변화 값을 도출 하기 위해 kilovoltage CT (kV CT)와 MV CBCT를 이용하여 12 종류의 전자 밀도 바를 제공하는 Cheese 팬텀의영상을 획득하고, 영상들로부터 kV CT와 MV CBCT의 Hounsfield Unit (HU)값들의 관계를 도출하였다. MV CBCT 영상의 잡음을 감소하기 위해 Gaussian smoothing 필터를 적용하였다. MV CBCT영상의 intensity는 마치 동일한 모달리티에서 획득된 영상과 같은 kV CT와 동일한 범위의 intensity로 변화시켰다. 이후 두 영상에 효율적이고 사용하기 쉬운 intensity 기반의 데몬 영상 정합이 적용되었다. 본 연구실에서 인체 내 폐를 모사하도록 제작된 변형 폐 팬텀을 이용하여 위와 같은 방법을 적용하여 영상 정합을 하였다. Cheese 팬텀 영상, 변형 폐 팬텀 영상을 이용한 변형영상 정합 결과는 상관 계수가 각각 6.07%, 18% 향상되었다. 변형 폐 팬텀 영상의 변형 영상 정합 정확성을 평가하기 위해 추가적으로 측정된 팬텀 내부에 삽입한 표적의 중심 좌표를 이용하여vector 차이를 계산하였다. 벡터 차이는 $2.23{\pm}1.19mm$, $1.39{\pm}0.97mm$였다. 본 연구에서 사용한 intensity 변화 방법을 통해 변형 영상 정합의 정확성이 향상됨을 확인 하였고, 본 연구는 영상 정합 정확성을 향상시키기 위한 해결 방법이 될 수 있다. 차후 연구 계획도 본 연구 내용에 의해 제안되었다.

경계-적응 칼만필터를 이용한 Port Films의 영상개선에 관한 연구 (A Study on the Image Enhancement of Port Films using Edge-Adaptive Kalmsn filter)

  • 박순옥
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.427-432
    • /
    • 1996
  • The primary purpose of port filming is to verify the treatment volume under treatment. Although the image quality with the megavoltage x-ray beam is poorer than with the diagnostic or the simulator film. This paper proposes an edge-adaptive Kalman filter for the image enhancement of port films. Suggested filtering procedure preserves edge information and eliminates edge noise and inside and outside treatment area preserving treatment boundary.

  • PDF

POLARITY AND ION RECOMBINATION CORRECTION FACTORS OF A THIMBLE TYPE IONIZATION CHAMBER WITH DEPTH IN WATER IN THE MEGAVOLTAGE BEAMS

  • Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
    • Journal of Radiation Protection and Research
    • /
    • 제34권2호
    • /
    • pp.43-48
    • /
    • 2009
  • When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.

Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상 (Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing)

  • 김민주;조웅;강영남;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.62-69
    • /
    • 2012
  • 적응 방사선 치료(Adaptive Radiation Therapy, ART)를 실행하기 위한 매 치료 마다 획득되는 Megavoltage cone-beam CT (MVCBCT) 영상을 이용한 재 선량 계산 과정은 필수적이다. 본 연구의 목적은 intensity 보정 방법을 적용한 MVCBCT 영상 기반의 선량 계산 결과와 kilo-voltage CT (kV CT) 영상 기반의 선량 계산 결과의 비교 및 MVCBCT 영상 기반의 선량계산 정확성의 향상이다. MVCBCT 영상의 intensity 교정을 위해 kV CT와 MVCBCT을 이용하여 12 종류의 전자밀도 바를 제공하는 Cheese 팬텀 영상을 획득하고, Cheese 팬텀 영상의 동일한 전자밀도 바에서 표현되는 kV CT 영상과 MVCBCT 영상의 intensity 관계를 도출하였다. 이후 kV CT, MVCBCT를 이용한 Rando 팬텀 영상을 획득하여 MVCBCT 영상은 3차원 강체 정합을 수행하였고 본 과정을 통해 MVCBCT 영상은 kV CT 영상과 마치 동일한 모달리티에서 획득한 영상과 같은 위치 및 intensity 분포로 변환되었고, MVCBCT 영상의 잡음을 없애기 위한 Gaussian smoothing 필터를 적용하였다. 위의 과정을 거친 MVCBCT 영상을 토대로 intensity 교정을 적용한 영상과, intensity 교정을 적용하지 않은 영상, kV CT영상을 기반으로 방사선 치료 계획 시스템을 이용한 선량 계산을 시행 하였다. 선량 계산의 결과는 선량 분포의 차이 및 Percentage difference로 평가되었다. Intensity 보정을 적용한 MVCBCT 영상의 선량 계산 결과의 경우 kV CT 영상 기반의 선량 계산 결과와의 Percentage difference가 두경부 영상의 경우 1.08%, 흉부 영상의 경우 2.44%였다. 본 연구에서 적용한 intensity 변환을 통해 MVCBCT 영상을 이용한 선량 계산의 정확성이 향상됨을 확인하였고, 본 연구 방법은 실제 선량 계산에 적용 및 사용의 편리성을 확인하였다. 차후 연구 계획도 본 연구 내용에 의해 제안되었다.

방사선치료의 다양한 EPID 영상 질평가 (Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy)

  • 손순룡;최관우;김정민;정회원;권경태;조정희;이제희;정재용;김기원;이영아;손진현;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.451-461
    • /
    • 2015
  • MV방사선 치료는 둘러싸여 있는 정상조직의 피폭선량을 최소화 하면서, target volume 내에 정확하게 선량을 전달하는데 있어 중요한 요인이다. 본 연구에서는 방사선 치료의 높은 정확성을 유지하기 위하여 megavoltage X-ray imaging (MVI)에서 edge block 을 사용한 digital radiography (DR) system 검출기의 modulation transfer function (MTF: 변조전달함수), the noise power spectrum (NPS: 잡음전력스펙트럼) and the detective quantum efficiency (DQE: 양자검출효율)를 측정하고자 한다. 우리는 텅스텐으로 구성된 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$의 edge block을 사용하였으며, 다음과 같은 setting들로 pre-sampling modulation transfer function (MTF)를 계산하였다: 6-megavolt (MV) energy를 사용하고, 다양한 Radiotherapy장비인 TrueBeamTM (Varian), BEAMVIEWPLUS (Siemens), iViewGT (Elekta), ClinacR iX (Varian) 를 사용하였다. MTF결과에서 Varian TrueBeamTM flattening filter free가 MTF의 50% ($mm^{-1}$)에서 0.46, 10% ($mm^{-1}$) 에서 1.40로 가장 highest value를 보였다. Noise 분포는 Elekta iViewGT가 가장 낮은 분포를 보였다. DQE에서는 E lekt a iViewGT가 peak DQE에서 0.0026 그리고 $1mm^{-1}$ DQE 에서 0.00014로 가장 높았다. 본 연구는 Edge method를 이용하여 MTF와 DQE산출을 재현하였으며, 현재 임상에서 사용되는 DR 시스템 측정의 높은 정확성을 유지할 수 있었으며 이러한 연구는 전통적인 QA 영상화뿐만 아니라 검출기 개발 연구에 있어서 정량적인 MTF, NPS, DQE 측정에 더욱 더 효율적으로 사용될 수 있다는 것을 알 수 있다.