• Title/Summary/Keyword: Medium- and low-rise

Search Result 73, Processing Time 0.039 seconds

Electron Transport Activities of Chloroplasts Isolated from the Detached Rice Leaves Stored under Low Temperature with Illumination (광 및 저온처리한 벼잎 절편에서 분이한 엽록체의 전자전달 활성)

  • 문병용
    • Journal of Plant Biology
    • /
    • v.31 no.4
    • /
    • pp.299-307
    • /
    • 1988
  • The electron transport activities of choloroplasts isolated from hte detached rise (Oryza sativa L. cv. Chucheong) leave stored under low temperature(4$^{\circ}C$) with light illumination were investigated to understand the role of light in the low temperature inhibition of photosynthesis in the chilling-sensitive plants. Chlorophyll content of the detached leaves upon incubation at 28$^{\circ}C$ and 4$^{\circ}C$ in the dark was also measured. The rice seedlings were grown with Hoagland medium in the growth chamber of 28$^{\circ}C$ temperature and 400 ft.c fluorescent light with the photoperiod of 16 h. Although chlorophyll content of the detached leaves stored in the dark declined by 61.7% after 28$^{\circ}C$ treatement, there occurred only 5.2% decrease of chlorophyll with 4$^{\circ}C$ treatment. Low temperature treatment(4$^{\circ}C$) for 6 days brought about decreases in total photosystem(PS II+PS I) activities by 35.2% and 73.6% in te presence and absence of light, respectively, while after 28$^{\circ}C$ treatment of the detached leaves for 6 days in the dark there was only 27.6% decrease in PS II+PS I activity. PS II activities were also decreased by 35.6% and 72.2% in the light and dark, respectively. PS I activities were decreased slightly, however, by 7.6% and 16.2% in the light and dark, respectively. Investigations into DPClongrightarrowDCPIP and NH2OHlongrightarrowDCPIP activities revealed that low temperature inhibition of PS II activities was not due to the inactivation of the water oxidation capacity at low temperature. It was concluded that light protects the electron transport activities of isolated rice chloroplasts from the inhibitory effect of low temperature in the detached leaves.

  • PDF

Retrofitting of vulnerable RC structures by base isolation technique

  • Islam, A.B.M. Saiful;Jumaat, Mohd Zamin;Ahmmad, Rasel;Darain, Kh. Mahfuz ud
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.603-623
    • /
    • 2015
  • The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.

Hydraulic & Hydrologic Design Criteria for an Emergency Drainage of Reservoir (II) (댐 비상방류 설계기준 선정을 위한 수리수문학적 검토(II))

  • Yi, Jaeeung;Son, Kwangik;Kang, Min Suk
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.3
    • /
    • pp.159-167
    • /
    • 2015
  • Low-level outlets are necessary to empty reservoir storage in case of emergency such as abrupt storage level rise due to storm, dam body inspection as well as initial reservoir storage filling. However, the Korean standard for low-level outlet should be complemented. In this study, the HEC-ResSim model is utilized to simulate and calculate the capacity of the outlets and the days of release in order to evacuate reservoir storage safely. Three cases are analyzed according to its capacity. As a large dam with more than $1,000{\times}106m^3$ total capacity, Soyanggang Dam is selected and as a medium dam between $100{\times}106m^3$ and $1,000{\times}106m^3$ total capacity, Habcheon Dam is selected. Finally as a small dam with a total capacity less than $100{\times}106m^3$, Daegok Dam is selected. The size of low-level outlet and days of storage evacuation is estimated and the applicability of the analysis method is studied.

Estimation of earthquake induced story hysteretic energy of multi-Story buildings

  • Wang, Feng;Zhang, Ning;Huang, Zhiyu
    • Earthquakes and Structures
    • /
    • v.11 no.1
    • /
    • pp.165-178
    • /
    • 2016
  • The goal of energy-based seismic design is to obtain a structural design with a higher energy dissipation capacity than the energy dissipation demands incurred under earthquake motions. Accurate estimation of the story hysteretic energy demand of a multi-story structure is the key to meeting this goal. Based on the assumption of a mode-equivalent single-degree-of-freedom system, the energy equilibrium relationship of a multi-story structure under seismic action is transformed into that of a multi-mode analysis of several single degree-of-freedom systems. A simplified equation for the estimation of the story seismic hysteretic energy demand was then derived according to the story shear force and deformation of multi-story buildings, and the deformation and energy relationships between the mode-equivalent single-degree-of-freedom system and the original structure. Sites were categorized into three types based on soil hardness, namely, hard soil, intermediate hard (soft) soil, and soft soil. For each site type, a 5-story and 10-story reinforced concrete frame structure were designed and employed as calculation examples. Fifty-six earthquake acceleration records were used as horizontal excitations to validate the accuracy of the proposed method. The results verify the following. (1) The distribution of seismic hysteretic energy along the stories demonstrate a degree of regularity. (2) For the low rise buildings, use of only the first mode shape provides reasonably accurate results, whereas, for the medium or high rise buildings, several mode shapes should be included and superposed to achieve high precision. (3) The estimated hysteretic energy distribution of bottom stories tends to be underestimated, which should be modified in actual applications.

Measurement of Effective Refractive Index of Anodic Aluminum Oxide Using a Prism Coupler

  • Gong, Su-Hyun;Cho, Y.H.;Stolz, Arnaud;Gokarna, Anisha;Dogheche, Elhadj;Ryu, Sang-Wan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.195-195
    • /
    • 2010
  • In recent years, Anodic aluminum oxide(AAO) has become popular and attractive materials. It can be easily fabricated and self-organized pore structures. It has been widely used as a biosensor membrane, photonic crystal for optical circuit and template for nanotube growth etc. In previous papers, the theory was developed that AAO shows anisotropic optical properties, since it has anisotropic structure with numerous cylindrical pores. It gives rise to the anisotropy of the refractive index called as birefringence. It can be used as conventional polarizing elements with high efficiency and low cost. Therefore, we would like to compare the theory and experimental results in this study. One method which can measure effective refractive index of thin film is the prism coupling technique. It can give accurate results fast and simply. Furthermore, we can also measure separately the refractive index with different polarization using polarization of the laser (TE mode and TM mode). We calculated the effective refractive index with effective medium approximations (EMAs) by pore size in the SEM image. EMAs are physical models that describe the macroscopic system as the homogeneous and typical method of all mean field theories.

  • PDF

Evaluation of Sampling Methodology for the Measurement of Polycyclic Aromatic Hydrocarbons in the Atmosphere (대기 중 다환방향족 탄화수소의 측정을 위한 시료포집방법의 비교평가)

  • 백성옥;최진수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.1
    • /
    • pp.43-62
    • /
    • 1998
  • This study was carried out to investigate the influence of different sampling methods on the measured concentrations of polycyclic aromatic hydrocarbons (PAH) both in the vapor and particulate phases, and to evaluate the effects of ambient temperature and sampling duration on the losses of PAH associated with particle samples due to volatilization. The experimental protocol of this study is consisted of two parts. The first part is related to the comparison of PAH concentrations measured by 4 different sampling systems, each of which involves different sampling principles for comparison purposes, including a medium-volume sampler with XAD-2 adsorbent, a high-volume sampler with polyurethane foam (PUF), two identical low-volume samplers: one with XAD-2 and the other with PUF, respectively. The second part of this study is to quantitatively estimate the losses of particulate PAH samples by volatilization during sampling, using two identical low-volume samplers: one was used for changing the filters every 3 hrs, 6 hrs, 12 hrs, and 24 hrs sampling, while the other was maintained for continuous 48 hours sampling without changing the filter. The concentrations of volatile PAH including 2-3 rings appeared to be significantly affected by the type of adsorbent. Measured levels of these lower-molecular weight PAH by XAD-2 adsorbent were much higher than those by PUF for both high-volume and low-volume sampling. PUF was found to give rise to unknown components that interfered with the PAH analysis, even after extensive clean-up. In addition, the retention efficiency of PUF for lower molecular weight PAH was subject to a large variation, being significantly influenced by sampling conditions such as ambient temperature. However, the effect of sampling methods with different adsorbents on the measured levels of semi-volatile compounds including 4 rings PAH such as fluoranthene, pyrene, BaA and chrysene, was not so much significant as more volatile PAH compounds. It was also clear from this study that volatilization losses of the semi-volatile PAH collected on the filters were inevitably occurred during prolonged sampling, and hence the results obtained from conventional sampling methods may not be expected to yield an accurate distribution of PAH between the vapor and particulate phases.

  • PDF

Feasibility study for blind-bolted connections to concrete-filled circular steel tubular columns

  • Goldsworthy, H.M.;Gardner, A.P.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.4
    • /
    • pp.463-478
    • /
    • 2006
  • The design of structural frameworks for buildings is constantly evolving and is dependent on regional issues such as loading and constructability. One of the most promising recent developments for low to medium rise construction in terms of efficiency of construction, robustness and aesthetic appearance utilises concrete-filled steel tubular sections as the columns in a moment-resisting frame. These are coupled to rigid or semi-rigid connections to composite steel-concrete beams. This paper includes the results of a pilot experimental programme leading towards the development of economical, reliable connections that are easily constructed for this type of frame. The connections must provide the requisite strength, stiffness and ductility to suit gravity loading conditions as well as gravity combined with the governing lateral wind or earthquake loading. The aim is to develop connections that are stiffer, less expensive and easier to construct than those in current use. A proposed fabricated T-stub connection is to be used to connect the beam flanges and the column. These T-stubs are connected to the column using "blind bolts" with extensions, allowing installation from the outside of the tube. In general, the use of the extensions results in a dramatic increase in the strength and stiffness of the T-stub to column connection in tension, since the load is shared between membrane action in the tube wall and the anchorage of the bolts through the extensions into the concrete.

Fragility assessment of RC-MRFs under concurrent vertical-horizontal seismic action effects

  • Farsangi, Ehsan Noroozinejad;Tasnimi, Abbas Ali;Mansouri, Babak
    • Computers and Concrete
    • /
    • v.16 no.1
    • /
    • pp.99-123
    • /
    • 2015
  • In this study, structural vulnerability of reinforced concrete moment resisting frames (RC-MRFs) by considering the Iran-specific characteristics is investigated to manage the earthquake risk in terms of multicomponent seismic excitations. Low and medium rise RC-MRFs, which constitute approximately 80-90% of the total buildings stock in Iran, are focused in this fragility-based assessment. The seismic design of 3-12 story RC-MRFs are carried out according to the Iranian Code of Practice for Seismic Resistant Design of Buildings (Standard No. 2800), and the analytical models are formed accordingly in open source nonlinear platforms. Frame structures are categorized in three subclasses according to the specific characteristics of construction practice and the observed seismic performance after major earthquakes in Iran. Both far and near fields' ground motions have been considered in the fragility estimation. An optimal intensity measure (IM) called Sa, avg and beta probability distribution were used to obtain reliable fragility-based database for earthquake damage and loss estimation of RC buildings stock in urban areas of Iran. Nonlinear incremental dynamic analyses by means of lumped-parameter based structural models have been simulated and performed to extract the fragility curves. Approximate confidence bounds are developed to represent the epistemic uncertainties inherent in the fragility estimations. Consequently, it's shown that including vertical ground motion in the analysis is highly recommended for reliable seismic assessment of RC buildings.

Shear behavior of exposed column base connections

  • Cui, Yao
    • Steel and Composite Structures
    • /
    • v.21 no.2
    • /
    • pp.357-371
    • /
    • 2016
  • Column base connections are critical components in steel structures because they transfer axial forces, shear forces and moments to the foundation. Exposed column bases are quite commonly used in low- to medium-rise buildings. To investigate shear transfer in exposed column base plates, four large scale specimens were subjected to a combination of axial load (compression or tension) and lateral shear deformations. The main parameters examined experimentally include the number of anchor rod, arrangement of anchor rod, type of lateral loading, and axial force ratio. It is observed that the shear resisting mechanism of exposed column base changed as the axial force changed. When the axial force is in compression, the resisting mechanism is rotation type, and the shear force will be resisted by friction force between base plate and mortar layer. The specimens could sustain inelastic deformation with minimal strength deterioration up to column rotation angle of 3%. The moment resistance and energy dissipation will be increased as the number of anchor rods increased. Moreover, moment resistance could be further increased if the anchor rods were arranged in details. When the axial force is in tension, the resisting mechanism is slip type, and the shear force will be resisted by the anchor rods. And the shear resistance was reduced significantly when the axial force was changed from compression to tension. The test results indicated that the current design approach could estimate the moment resistance within reasonable acceptance, but overestimate the shear resistance of exposed column base.

An Analysis of Floor layout and Fashion Brands -Focused on Adjacent Department Stores within 3 Division- (인접한 백화점간의 MD현황 비교분석 -서울시내 3개 지역 백화점을 중심으로-)

  • 유지헌
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.5
    • /
    • pp.139-153
    • /
    • 2004
  • The first purpose of this study was to compare the fashion zones and fashion brands on the floors in small and medium volume department store with those of big department stores within adjacent trading area. The second purpose was to find out similarity and differentiation of near-by department stores. The third one was to propose the future fashion marketing strategies of the department stores. The methods used were references, internet, field observation, and interview in 2002. Eight department stores within adjacent trading area were classified and analysed In "Gangnam division", "Seocho division'. and "Youngdeungpo division". The results were as follows : Firstly, there was a low relationship between the degrees of brand equalization of each department store in the "Gangnam, Seocho. and Youngdeungpo division". Secondly, there was an alteration on the floor layout of each department store. It was layed out in a way that allowed for customers, who wanted to just purchase specific items, to go upstairs and look around several stores, which allowed for not only rise in the amount of sales but also offer the convenience of one stop shopping for the customers. Thirdly I proposed several marketing strategies such as lifestyle marketing, relationship marketing, and compile marketing which solves everyday life agenda. I also proposed the solution selling education to develop service education of salesperson. I finally proposed the overriding priority policy by sales record of each store.licy by sales record of each store.