• 제목/요약/키워드: Medison

검색결과 64건 처리시간 0.02초

국내산 토마토 품종의 생리활성 물질의 특성 (Characterization of Bioactive Compounds of Domestic Tomato Varieties)

  • 안준배
    • 한국조리학회지
    • /
    • 제24권1호
    • /
    • pp.63-72
    • /
    • 2018
  • The aim of this study was to investigate bioactive compounds from three domestic tomato varieties (Rafito, Momotaro TY Winner, and Medison). Lycopene, ${\beta}-carotene$ and polyphenols were quantified and identified using HPLC and LC-MS/MS. The levels of lycopene ranged from 28.36 mg/100 g to 60.18 mg/100 g. The content of ${\beta}-Carotene$ ranged from 2.00 mg/100 g to 2.92 mg/100 g. Ten kinds of polyphenol compounds were identified: caffeic acid-hexose isomer (I), caffeic acid-hexose isomer (II), 3-caffeoylquinic acid, 5-caffeoylquinic acid, caffeoylquinic acid isomer, quercetin-3-apiosylrutinoside, quercetin-3-rutinoside, di-caffeoylquinic acid, tri-caffeoylquinic acid, and naringenin chalcone. The level of 5-caffeoylquinic acid was the highest in domestic tomato varieties, ranging from 12.71 mg/100 g to 28.40 mg/100 g. The content of quercetin-3-rutinoside ranged from 3.74 mg/100 g to 17.64 mg/100 g. The contents of 3-caffeoylquinic acid and quercetin-3-apiosylrutinoside were 1.01~2.31 mg/100 g and 5.84~6.83 mg/100 g, respectively. Arrestingly naringenin chalcone was found only in Medison variety (36.82 mg/100 g). These results revealed that domestic tomato can be a good source of bioactive compounds for human health.

Implementation of an Ultrasound Elasticity Imaging System

  • Cho Gae-Young;Yoon Ra-Young;Park Jeong-Man;Kwon Sung-Jae;Ahn Young-Bok;Bae Moo-Ho;Jeong Mok-Kun
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권3호
    • /
    • pp.117-124
    • /
    • 2006
  • Recently, active research has been going on to measure the elastic modulus of human soft tissue with medical ultrasound imaging systems for the purpose of diagnosing cancers or tumors which have been difficult to detect with conventional B-mode imaging techniques. In this paper, a real-time ultrasonic elasticity imaging system is implemented in software on a Pentium processor-based ultrasonic diagnostic imaging system. Soft tissue is subjected to external vibration, and the resulting tissue displacements change the phase of received echoes, which is in turn used to estimate tissue elasticity. It was confirmed from experiment with a phantom that the implemented elasticity imaging system could differentiate between soft and hard regions, where the latter is twice harder than the former, while operating at an adequate frame rate of 20 frames/s.

Localized MRI/MRS를 위한 차폐된 두뇌촬영용 $R^{2}$-경사자계코일 (Actively-Shielded Brain-Only $R^{2}$-Gradient Coil for Localized MRI/MRS)

  • 오창현;양윤정;김선경;이윤;이흥규;안창범
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.161-164
    • /
    • 1996
  • An actively-shielded $r^{2}$-gradient coil has been developed for brain localized MRI or MRS. Spatial localization is very useful for spatial volume selection in MRI or MR Spectroscopy(MRS). The radial(or $R^{2}-$) gradient coil is useful in reducing the artifact or in improving the SNR by selecting the volume with less number of RF pulses. It is, however, difficult to implement the coil with a gradient intensity strong enough to use it for practical whole-body MRI system. For example, the smallest volume size for selection is just 6 cm in diameter with a 250 Ampere of current driving for a whole-body system (in case of 70-cm-diameter). In this study, an asymetric $r^{2}$-coil with a small diameter of 35 cm has been designed and implemented for brain localized MRI or MRS. An 8-rod high-pass-type birdcage RF coil has also been implemented. The coil set has been developed for 1.0 Tesla Medison MRI system and its performance has been verified experimentally.

  • PDF

단일전력단 고역률 AC/DC Two-Switch Forward 컨버터 (Single-Stage High Power Factor AC/DC Two-Switch Forward Converter)

  • 배진용;김용;권순도;이규훈;계상범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

Three-Level 컨버터의 효율특성에 관한 연구 (Efficiency Characteristic of Three-Level Converter)

  • 배진용;김용;이은영;계상범;엄태민;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.187-193
    • /
    • 2007
  • This paper presents the Efficiency Characteristic of Three-Level Converter. Three-Level DC/DC Converter Presented in this paper is used a phase shift control with a flying capacitor in the primary side to achieve ZVS for the outer switch. This converter reduces the voltage stress across the main switch to half of input voltage. This paper analyses the loss of each component and the various losses for efficiency variation. The result of the analysis are verified using 3kW prototype.

  • PDF

첨단기술 기반기업(NTBF)의 성장 요인 분석 - 역동적 기업 역량(DFC)의 시각에서 -

  • 손찬;정재용
    • 한국기술혁신학회:학술대회논문집
    • /
    • 한국기술혁신학회 2003년도 춘계학술대회
    • /
    • pp.369-388
    • /
    • 2003
  • This research has been focused upon and analyzing Medison, once a leading New Technology-Based Firm (NTBF) in Korea with exceptionally advanced technology in 3D ultrasound diagnostic imaging devices (UDIDs) (armored with 23 subsidiaries at its peak expansion), from the perspective if Dynamic Firm Capability(DFC). The underlying hypothesis is that the various problems from its pointless pursuit of the business styles or precedents of the existing large firms might be traced to its specific characteristics as an NTBF, which should have more preferably been based upon the distinctive competences such as differentiated technologies, institutional linkages, organizational routines, and complementary assets, etc. In conclusion, for the NTBFs with different DFC domains from those of the large firms, the optimal external linkages and comprehensive integration efforts (Process) under their specific organizational characteristics and constraints (Path) are highly recommended for the continuous accumulation of their core capabilities based upon the technological assets (Position).

  • PDF

RC 기둥의 겹침이음파괴 시 철근의 응력 산정 (Calculation of Rebar Stress at Splice Failure of RC Columns)

  • 조재열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.446-449
    • /
    • 2006
  • Several experimental investigations have been carried out to study the behavior of reinforced concrete columns with short lap splices. However, very few analytical models have been developed for the analysis of such columns subjected to earthquakes. As nonlinear analysis procedures become more common in practice (such as those outlined in the Guidelines for Seismic Rehabilitation of Buildings published by the Federal Emergency Management Agency in the United States), the need for an accurate and reliable representation of the nonlinear response of strength degrading systems becomes more important. In this study, an analytical model for estimating the complete response of reinforced concrete columns with short lap splices is presented. The model is based on local bond stress-slip relationships and is validated against independent experimental data from cyclic loading tests on reinforced concrete columns with typical construction details of the 1960s. In this paper a simple equation for calculating the bar stress at splice failure is presented. Use of the proposed equation resulted in excellent agreement between the measured and calculated strength at splice failure.

  • PDF

새로운 자기공명영상촬영용 Quadrature Breast RF 코일 (A New Quadrature Breast RF Coil for MRI)

  • 김선경;양윤정;이덕래;이윤;안창범;오창현
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.291-293
    • /
    • 1997
  • A new quadrature RF coil is designed for Breast MR Imaging. Quadrature RF coils for MRI have been useful to improve the signal-to-noise ratio (SNR) by "$\sqrt{2}$" using two orthogonal RF coils in combination. A modified Breast Quadrature coil is designed. It is a modified type of the high-pass birdcage coil. To reduce the field distortion, by using current feeding, the field pattern is optimized to achieve a quadrature circularly-polarized field pattern. The coil has been implemented for receive-only mode, and tested by phantom imaging. The experimental results show the utility of the proposed RF coil.

  • PDF