• 제목/요약/키워드: Medical ultrasound system

검색결과 160건 처리시간 0.027초

초음파 간영상의 특징벡터 분류 및 진단시스템 구현에 관한 연구 (A Study on the Classification of Ultrasonic Liver Image Feature Vectors and the Design of Diagnosis System)

  • 정정원;김동윤
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.177-182
    • /
    • 1995
  • Since one property(i.e. coarseness, orientation, regularity, granularity etc.) of ultrasound liver images was not sufficiently enough to classify the characteristics of livers, we used the multi-feature vectors from ultrasound images to diagnose the liver disease. The proposed classifier, which uses the multi-feature vectors and Bayes decision rule, performed well for the classification of normal, fat and cirrhosis liver. In our simulation, we used the Battacharyya distance and Hotelling Trace Criterion to select the best multi-feature vectors for the classifier and obtained less classification errors than other methods using single feature vector.

  • PDF

대동맥분기에서의 혈액유동: 맥도플러초음파 및 레이저도플러계측기를 사용한 연구 (Blood Flow in an Aortic Bifurcation Model: Pulsed Doppler Ultrasound and Laser Doppler Anemometry Studies)

  • 김영호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 추계학술대회
    • /
    • pp.43-46
    • /
    • 1992
  • $\underline{In\;vitro}$ velocity measurements were made using both the pulsed Doppler ultrasound (PDU) machine and laser Doppler anemometer (LDA) system in order to investigate the flow characteristics near the aortic bifurcation. Velocities measured from the PDU machine was in good agreement with those from the LDA. The flow in the daughter branches was three-dimensional with a secondary flow. The oscillating wall shear stress with this secondary fluid motion is well correlated with the localization of the atherosclerosis.

  • PDF

Performance Enhancement of Ultrasonic Sensitivity by Improving the Transmitter Circuit

  • Lee, Cheul-Won;Kim, Young-Kil
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권4호
    • /
    • pp.164-169
    • /
    • 2006
  • We have developed the spirometer system; many patients having weak respiration have difficulties in using conventional spirometers in hospitals, because their weak breath can be affected by the errors of inertia and instrumental pressure. We have developed a new ultrasound spirometer using an ARM 920T processor. To detect weak respiratory signals, we add a comparator circuit, which can afford more information of respiration characteristics such as respiration volume, directions, and velocities. We have also developed Gill for graphical display of respiration characteristics. Through the pilot test, it has been verified that the developed spirometer is operating reliably.

PW 도플러 시스템에서 Base Line 이동 기법을 이용한 오디오 신호 처리 방법 (Audio Processing Algorithm Using Base Line Shift Method in Pulsed Doppler Systems)

  • 김기덕;송태경
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권3호
    • /
    • pp.275-281
    • /
    • 1999
  • 현재 널리 쓰이고 있는 PW 도플러 시스템 주파수가 나이퀴스트 주파수를 초과할 경우 스텍트럼 aliasing 현상에 의하여 정확한 혈류 속도의 측정을 할 수 없다는 문제점을 가지고 있다 . 도플러 스펙트럼의 aliasing 현상을 극복하기 위하여 통상적으로 기준선 (Base Line) 이동기법을 사용하고 있으나 도플러 오디오 신호는 aliasing 된채로 남게 된다. 이 논문에서는 주파수 천이 및 필터링 기법들을 적절히 적용하여 기준선 이동시 도플러 스텍트럼과 오디오 신호의 aliasing 현상을 함께 제거할 수 있는 기법을 제안한다. 제안된 방법은 단방향 혈류 성분을 검사하는 경우 aliasing 현상 없이 측정 가능한 도플러 주파수를 나이퀴스트 주파수의 두배인 PRF 까지 증가되도록 한다. 실제 시스템에서 얻어진 신호를 이용하여 제안된 방법을 실험적으로 검증하였다.

  • PDF

Human Fibroblast-derived Multi-peptide Factors and the Use of Energy-delivering Devices in Asian Patients

  • Suh, Sang Bum;Ahn, Keun Jae;Chung, Hye Jin;Suh, Ji Youn;Cho, Sung Bin
    • Medical Lasers
    • /
    • 제9권1호
    • /
    • pp.12-24
    • /
    • 2020
  • Human fibroblast-derived multi-peptide factors (MPFs) have been used during treatments with energy-delivering modalities to enhance energy-induced tissue reactions. Human fibroblast-derived MPFs, which include a range of growth factors and chemoattractive factors, activate and recruit fibroblasts and endothelial cells, as well as promote extracellular matrix deposition, all of which are crucial to wound repair. Interestingly, fibroblasts from different species or anatomical sites exhibit distinct transcriptional properties with high heterogeneity. In addition, the patterns of MPF secretion can differ under a range of experimental conditions. Therefore, the use of allogeneic fibroblasts and proper cultivation thereof are necessary to obtain MPFs that can enhance the epithelial-mesenchymal interactions during wound repair. Moreover, energy-delivering devices should be selected according to evidence demonstrating their therapeutic efficacy and safety on a pathological skin condition and the major target skin layers. This paper reviewed the histologic patterns of post-treatment tissue reactions elicited by several energy sources, including non-ablative and ablative fractional lasers, intense focused ultrasound, non-invasive and invasive radiofrequency, picosecond-domain lasers, and argon and nitrogen plasma. The possible role of the immediate application of human fibroblast-derived MPFs during wound repair was proposed.

Effect of a Deep Learning Framework-Based Computer-Aided Diagnosis System on the Diagnostic Performance of Radiologists in Differentiating between Malignant and Benign Masses on Breast Ultrasonography

  • Ji Soo Choi;Boo-Kyung Han;Eun Sook Ko;Jung Min Bae;Eun Young Ko;So Hee Song;Mi-ri Kwon;Jung Hee Shin;Soo Yeon Hahn
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.749-758
    • /
    • 2019
  • Objective: To investigate whether a computer-aided diagnosis (CAD) system based on a deep learning framework (deep learning-based CAD) improves the diagnostic performance of radiologists in differentiating between malignant and benign masses on breast ultrasound (US). Materials and Methods: B-mode US images were prospectively obtained for 253 breast masses (173 benign, 80 malignant) in 226 consecutive patients. Breast mass US findings were retrospectively analyzed by deep learning-based CAD and four radiologists. In predicting malignancy, the CAD results were dichotomized (possibly benign vs. possibly malignant). The radiologists independently assessed Breast Imaging Reporting and Data System final assessments for two datasets (US images alone or with CAD). For each dataset, the radiologists' final assessments were classified as positive (category 4a or higher) and negative (category 3 or lower). The diagnostic performances of the radiologists for the two datasets (US alone vs. US with CAD) were compared Results: When the CAD results were added to the US images, the radiologists showed significant improvement in specificity (range of all radiologists for US alone vs. US with CAD: 72.8-92.5% vs. 82.1-93.1%; p < 0.001), accuracy (77.9-88.9% vs. 86.2-90.9%; p = 0.038), and positive predictive value (PPV) (60.2-83.3% vs. 70.4-85.2%; p = 0.001). However, there were no significant changes in sensitivity (81.3-88.8% vs. 86.3-95.0%; p = 0.120) and negative predictive value (91.4-93.5% vs. 92.9-97.3%; p = 0.259). Conclusion: Deep learning-based CAD could improve radiologists' diagnostic performance by increasing their specificity, accuracy, and PPV in differentiating between malignant and benign masses on breast US.

Safety of a Totally Implantable Central Venous Port System with Percutaneous Subclavian Vein Access

  • Keum, Dong-Yoon;Kim, Jae-Bum;Chae, Min-Cheol
    • Journal of Chest Surgery
    • /
    • 제46권3호
    • /
    • pp.202-207
    • /
    • 2013
  • Background: The role of totally implantable central venous port (TICVP) system is increasing. Implantation performed by radiologist with ultrasound-guided access of vein and fluoroscope-guided positioning of catheter is widely accepted nowadays. In this article, we summarized our experience of TICVP system by surgeon and present the success and complication rate of this surgical method. Materials and Methods: Between March 2009 and December 2010, 245 ports were implanted in 242 patients by surgeon. These procedures were performed with one small skin incision and subcutaneous puncture of subclavian vein. Patient's profiles, indications of port system, early and delayed complications, and implanted period were evaluated. Results: There were 82 men and 160 women with mean age of 55.74. Port system was implanted on right chest in 203, and left chest in 42 patients. There was no intraoperative complication. Early complications occurred in 11 patients (4.49%) including malposition of catheter tip in 6, malfunction of catheter in 3, and port site infection in 2. Late complication occurred in 12 patients (4.90%). Conclusion: Surgical insertion of TICVP system with percutaneous subclavian venous access is safe procedures with lower complications. Careful insertion of system and skilled management would decrease complication incidence.

좌심실 보조기를 이용한 3상형 박동류 모의 (Emulation of Tri-Phasic Pulsatile Flow Using LVAD)

  • 이동혁;김종효
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.313-320
    • /
    • 1998
  • 3상형 박동류는 인체 순환계 혈류의 일반적인 형태이다. 심혈관계의 여러 가지 상황을 모의하려면 이러한 3상형 박동류를 만들어 내는 것이 필수적이다. 본 연구에서는 3상형 박동류를 모의하기 위해서 전기유압식 좌심실보조기를 유리 팬텀과 고무 튜브와 같이 사용하였으며 혈류 모의 시스템의 제어변수를 선정하고 각 변수들의 변화에 대한 영향을 도플러 초음파를 이용하여 관찰하였다. 본 실험의 결과 협착 후위부 탄성과 지연시간이 3상형 혈류를 생성하는 중요한 요인이었다. 본 실험의 결과들은 다양한 혈류 운동을 모의할 수 있게 해 줌으로써 심혈관계의 여러현상을 설명하는 유용한 도구가 될 수 있을 것으로 기대된다.

  • PDF

임베디드 하드웨어 시스템 기반의 초음파 폐활량계 구현 및 감도 향상 연구 (An Implementation of the embedded hardware system based Ultrasonic Spirometer and Improvement of Its Sensitivity)

  • 이철원;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.417-420
    • /
    • 2005
  • 폐활량계(Spirometer)는 호흡하는 가스의 용적 유량의 순간적인 속도를 측정하는 의료기구로 폐의 기능시험과 환자 모니터링에 사용되며 용적 유량 신호를 합친 폐의 절대적인 용적변화를 측정한다. 본 논문에서는 환자를 대상으로 약한 호흡에서도 폐활량 측정이 가능 하도록, 관성의 오차 및 압력의 오차에 영향을 거의 받지 않는 초음파 센서를 이용하여 송수신시 초음파 신호를 향상시켰으며, 임베디스 하드웨어 시스템을 사용하여 약한 호흡에도 정확하고 빠른 검출이 가능한 시스템을 구현하였다.

  • PDF

새로운 건강보험 보장성 강화 대책 3부: 비뇨생식기 초음파 및 MRI 급여 확대 (A New Healthcare Policy in Korea Part 3: Ultrasound and MRI in Urogenital Disorders)

  • 심영섭;박계진
    • 대한영상의학회지
    • /
    • 제81권5호
    • /
    • pp.1083-1095
    • /
    • 2020
  • 2019년 비뇨생식기 초음파와 MRI의 보험급여 범위가 확대되어 보다 많은 환자들이 급여로 영상검사를 받을 수 있게 되었다. 비뇨기계 초음파와 MRI는 암 환자 등 중증질환 환자에서 는 기존에도 급여 혜택을 받을 수 있었으나 이번 급여 범위 확대로 초음파의 경우 대부분의 질환, MRI의 경우에도 조직검사 전 전립선암이나 난소암 의증, 자궁근종절제술 시행 전 자궁 MRI, 각종 선천 기형 등 양성질환에서도 급여로 검사가 가능해졌다. 그러나 급여화로 인해 각 검사 별 적응증과 추적검사 가능 질환 및 횟수 등이 복잡해지고 획득하여야 할 표준영상과 언급하여야 하는 판독소견서의 양식이 정해져 있어 검사를 처방하고 시행하는 의사들이 주의해야 할 사항들이 생겼다. 건강보험 적용 기준에 대한 충분한 이해를 통한 진료는 환자들의 진료 결과를 증진시키는 데 도움이 될 것이다.