• Title/Summary/Keyword: Medical simulation

Search Result 1,328, Processing Time 0.025 seconds

Development of the Standard Blood Inventory Level Decision Rule in Hospitals (병원의 표준 혈액재고량 산출식 개발)

  • Kim, Byoung-Yik
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.195-206
    • /
    • 1988
  • Two major issues of the blood bank management are quality assurance and inventory control. Recently, in Korea blood donation has gained popularity increasingly to allow considerable improvement of the quality assurance with respect to blood collection, transportation, storage, component preparation skills and hematological tests. Nevertheless the inventory control, the other issue of blood bank management, has been neglected so far. For the supply of blood by donation barely meets the demand, the blood bank policy on the inventory control has been 'the more the better.' The shortage itself by no means unnecessitate inventory control. In fact, in spite of shortage, no small amount of blood is outdated. The efficient blood inventory control makes it possible to economize the blood usage in the practice of state-of-the-art medical care. For the efficient blood inventory control in Korean hospitals, this tudy is to develop formulae forecasting the standard blood inventory level and suggest a set of policies improving the blood inventory control. For this study informations of $A^+$ whole bloods and packed cells inventory control were collected from a University Hospital and the Central Blood Bank of the Korean Red Cross. Using this informations, 1,461 daily blood inventory records were formulated.48 varieties of blood inventory control environment were identified on the basis of selected combinations of 4 inventory control variables-crossmatch, transfusion, inhospital donation and age of bloods from external supply. In order to decide the optimal blood inventory level for each environment, simulation models were designed to calculate the measures of performance of each environment. After the decision of 48 optimal blood inventory levels, stepwise multiple regression analysis was started where the independent variables were 4 inventory control variables and the dependent variable was optimal inventory level of each environment. Finally the standard blood inventory level decision rule was developed using the backward elimination procedure to select the best regression equation. And the effective alternatives of the issuing policy and crossmatch release period were suggested according to the measures of performance under the condition of the standard blood inventory level. The results of this study' were as follows ; 1. The formulae to calculate the standard blood inventory level($S^*$)was $S^*=2.8617X(d)^{0.9342}$ where d is the mean daily crossmatch(demand) for a blood type. 2. The measures of performace - outdate rate, average period of storage, mean age of transfused bloods, and mean daily available inventory level - were improved after maintenance of the standard inventory level in comparison with the present system. 3. Issuing policy of First In-First Out(FIFO) decreased the outdate rate, while Last In-First Out(LIFO) decreased the mean age of transfused bloods. The decrease of the crossmatch release period reduced the outdate rate and the mean age of transfused bloods.

  • PDF

The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging (진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성)

  • Park, Ji-Koon;Heo, Ye-Ji;Park, Jeong-Eun;Park, Sang-Jin;Kim, Hyun-Hee;No, Ci-Chul;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.35-38
    • /
    • 2009
  • Flat-panel x-ray detectors using a phosphor and photoconductor material have been used for application in various medical modalities. In this study, the monte carlo simulation, optical and x-ray response characteristics were investigated in the conversion structure obtained by a columnar CsI:Na scintillation layer with a photosensitive amorphous selenium layer. Firstly, from the measurement of luminescent spectrum of CsI:Na and absorption spectrum of a-Se layer, the signal conversion characteristics are analysed. And also, the x-ray sensitivity is measured and compared with conventional a-Se($500{\mu}m$) as a function of electrical field. From the experimental result, the x-ray sensitivities of the CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) detector and the a-Se($500{\mu}m$) detector were $7.31nC/mR-cm^{2}$ and $3.95nC/mR-cm^{2}$at an electric field of $10V/{\mu}m$, respectively.

  • PDF

Cost Effectiveness Analysis of Different Management Strategies between Best Supportive Care and Second-line Chemotherapy for Platinum-resistant or Refractory Ovarian Cancer

  • Luealon, Phanida;Khempech, Nipon;Vasuratna, Apichai;Hanvoravongchai, Piya;Havanond, Piyalamporn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.2
    • /
    • pp.799-805
    • /
    • 2016
  • Background: There is no standard treatment for patients with platinum-resistant or refractory epithelial ovarian cancer. Single agent chemotherapies have evidence of more efficacy and less toxicity than combination therapy. Most are very expensive, with appreciable toxicity and minimal survival. Since it is difficult to make comparison between outcomes, economic analysis of single-agent chemotherapy regimens and best supportive care may help to make decisions about an appropriate management for the affected patients. Objective: To evaluate the cost effectiveness of second-line chemotherapy compared with best supportive care for patients with platinum-resistant or refractory epithelial ovarian cancer. Materials and Methods: A Markov model was used to estimate the effectiveness and total costs associated with treatments. The hypothetical patient population comprised women aged 55 with platinum-resistant or refractory epithelial ovarian cancer. Four types of alternative treatment options were evaluated: 1) gemcitabine followed by BSC; 2) pegylated liposomal doxorubicin (PLD) followed by BSC; 3) gemcitabine followed by topotecan; and 4) PLD followed by topotecan. Baseline comparator of alternative treatments was BSC. Time horizon of the analysis was 2 years. Health care provider perspective and 3% discount rate were used to determine the costs of medical treatment in this study. Quality-adjusted life-years (QALY) were used to measure the treatment effectiveness. Treatment effectiveness data were derived from the literature. Costs were calculated from unit cost treatment of epithelial ovarian cancer patients at various stages of disease in King Chulalongkorn Memorial Hospital (KCMH) in the year 2011. Parameter uncertainty was tested in probabilistic sensitivity analysis by using Monte Carlo simulation. One-way sensitivity analysis was used to explore each variable's impact on the uncertainty of the results. Results: Approximated life expectancy of best supportive care was 0.182 years and its total cost was 26,862 Baht. All four alternative treatments increased life expectancy. Life expectancy of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 0.510, 0.513, 0.566, and 0.570 years, respectively. The total cost of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 113,000, 124,302, 139,788 and 151,135 Baht, respectively. PLD followed by topotecan had the highest expected quality-adjusted life-years but was the most expensive of all the above strategies. The incremental cost-effectiveness ratios (ICER) of gemcitabine followed by BSC, PLD followed by BSC, gemcitabine followed by topotecan and PLD followed by topotecan was 344,643, 385,322, 385,856, and 420,299 Baht, respectively. Conclusions: All of the second-line chemotherapy strategies showed certain benefits due to an increased life-year gained compared with best supportive care. Moreover, gemcitabine as second-line chemotherapy followed by best supportive care in progressive disease case was likely to be more effective strategy with less cost from health care provider perspective. Gemcitabine was the most cost-effective treatment among all four alternative treatments. ICER is only an economic factor. Treatment decisions should be based on the patient benefit.

Development of Micro Wired pH Electrode for Real-Time Monitoring for Gastroesophageal Reflux (위식도 역류 실시간 모니터링 마이크로 와이어 pH 전극 개발)

  • Kim, Eung-Bo;Lee, Kyu-Jin;So, Sang-Kyun;Joung, Yeun-Ho;Park, Jung Ho;Kim, Nam Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.6
    • /
    • pp.277-284
    • /
    • 2017
  • This paper presents an implantable pH measurement electrode for wireless gastroesophageal reflux measurement. Usually, gastroesophageal reflux is diagnosed by a catheter-type wire connection between the esophagus and the diagnostic device which brings many side effects such as restriction of daily living, pain, and discomfort in the nasal cavity and pharynx of patients. In order to solve these issues, researchers have been studied a wireless measurement method and a micro-sized pH electrode for human body insertion is necessary. Commercial glass packaged pH meter is formed by a sensing and a reference electrodes in a KCl solution. However, if the glass meter is inserted into the human body, there are risks of leakage of the solution, breakage of the glass package, injury of the body elements. Therefore, the solution should be solidified on the micro-sized noble metal wire which has a characteristic of biocompatible. After solidified wire fabrication, the designed meter was tested for feasibility of measurement and the result was well agreed with pH values of commercial pH meter. Potentials in pH 1 to 12 solution was measured to obtain the sensitivity of the sensor with linearity. And we have designed a simulation of gastroesophageal reflux with symptom frequency, interval, and duration time in pH 2 solution. The proposed sensor has capable to get the same potential for 24 measurements in 3 days, and it has sensed same pH values of 2 for one hour with every 10 minutes. Furthermore, the sensor was survived for 48 hours with reasonable potentials in the acid solution.

An Implementation of 3D Graphic Accelerator for Phong Shading (퐁 음영법을 위한 3차원 그래픽 가속기의 구현)

  • Lee, Hyung;Park, Youn-Ok;Park, Jong-Won
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.5
    • /
    • pp.526-534
    • /
    • 2000
  • There have been many researches on the 3D graphic accelerator for high speed by needs of CAD/CAM,3D modeling, virtual reality or medical image. In this paper, an SIMD processor architecture for 3D graphic accelerator is proposed in order to improve the processing time of the 3D graphics, and a parallel Phong shading algorithm is presented to estimate performance of the proposed architecture. The proposed SIMD processor architecture for 3D graphic accelerator consists of PCI local bus interface, 16 Processing Elements (PE's), and Park's multi-access memory system (NAMS) that has 17 memory modules. A serial algorithm for Phong shading is modified for the architecture and the main key is to divide a polygon into $4\times{4}$ squares. And, for processing a square, 4 PE's are regarded as a PE Grou logically. Since MAMS can support block access type with interval 1, it is possible that 4 PE Groups process a square at a time. In consequence, 16 pixels are processed simultaneously. The proposed SIMD processor architecture is simulated by CADENCE Verilog-XL that is a package for the hardware simulation. With the same simulated results as that of the serial algorithm, the speed enhancement by the parallel algorithm to the serial one is 5.68.

  • PDF

An Energy Consumption Model using Two-Tier Clustering in Mobile Sensor Networks (모바일 센서 네트워크에서 2계층 클러스터링을 이용한 에너지 소비 모델)

  • Kim, Jin-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.9-16
    • /
    • 2016
  • Wireless sensor networks (WSN) are composed of sensor nodes and a base station. The sensor nodes deploy a non-accessible area, receive critical information, and transmit it to the base station. The information received is applied to real-time monitoring, distribution, medical service, etc.. Recently, the WSN was extended to mobile wireless sensor networks (MWSN). The MWSN has been applied to wild animal tracking, marine ecology, etc.. The important issues are mobility and energy consumption in MWSN. Because of the limited energy of the sensor nodes, the energy consumption for data transmission affects the lifetime of the network. Therefore, efficient data transmission from the sensor nodes to the base station is necessary for sensing data. This paper, proposes an energy consumption model using two-tier clustering in mobile sensor networks (TTCM). This method divides the entire network into two layers. The mobility problem was considered, whole energy consumption was decreased and clustering methods of recent researches were analyzed for the proposed energy consumption model. Through analysis and simulation, the proposed TTCM was found to be better than the previous clustering method in mobile sensor networks at point of the network energy efficiency.

An Efficient Addressing Scheme Using (x, y) Coordinates in Environments of Smart Grid (스마트 그리드 환경에서 (x, y) 좌표값을 이용한 효율적인 주소 할당 방법)

  • Cho, Yang-Hyun;Lim, Song-Bin;Kim, Gyung-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.1
    • /
    • pp.61-69
    • /
    • 2012
  • Smart Grid is the next-generation intelligent power grid that maximizes energy efficiency with the convergence of IT technologies and the existing power grid. Smart Grid is created solution for standardization and interoperability. Smart Grid industry enables consumers to check power rates in real time for active power consumption. It also enables suppliers to measure their expected power generation load, which stabilizes the operation of the power system. Smart industy was ecolved actively cause Wireless communication is being considered for AMI system and wireless communication using ZigBee sensor has been applied in various industly. In this paper, we proposed efficient addressing scheme for improving the performance of the routing algorithm using ZigBee in Smart Grid environment. A distributed address allocation scheme used an existing algorithm has wasted address space. Therefore proposing x, y coordinate axes from divide address space of 16 bit to solve this problem. Each node was reduced not only bitwise but also multi hop using the coordinate axes while routing than Cskip algorithm. I compared the performance between the standard and the proposed mechanism through the numerical analysis. Simulation verify performance about decrease averaging multi hop count that compare proposing algorithm and another. The numerical analysis results show that proposed algorithm reduce multi hop than ZigBee distributed address assignment and another.

Performance Comparison of Phase Detectors for the Synchronization Analysis of Electroencephalographic Signal (뇌파신호의 동기해석을 위한 위상검출기의 성능비교)

  • Kim, HyeJin;Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.277-284
    • /
    • 2013
  • The analysis of phase synchronization characteristics from EEG signals is important for the understanding of information processing functionality in the brain network. In this paper, wavelet transformation(WT), Hilbert tansformation (HT), complex demodulation (CD) methods having time localization characteristics were applied to real evoked potential data and noise added simulation data with center frequencies corresponding to EEG bands for the estimation performance analysis of phase offset, phase changing point, and interband crosstalk. The WT is the best both in ${\delta}$, ${\theta}$, and ${\alpha}$ band signal decomposition, and in analyzing phase synchronization performance. The CD can be efficiently used in changing point detection under tolerant noise condition because of its abrupt performance degradation over noise endurance level. From experimental observations, the WT is the most suitable in phase synchronization application of EEG signal, and the CD can be affordable in restricted application such as changing point detection for higher bands than ${\delta}$. Particularly, WT and CD can be used to detect the changing instant of brain function by indirectly estimating the phase changing point.

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF