• Title/Summary/Keyword: Medical radiation

Search Result 3,790, Processing Time 0.037 seconds

Development of the DVH management software for the biologically-guided evaluation of radiotherapy plan

  • Kim, Bo-Kyong;Park, Hee-Chul;Oh, Dong-Ryul;Shin, Eun-Hyuk;Ahn, Yong-Chan;Kim, Jin-Sung;Han, Young-Yih
    • Radiation Oncology Journal
    • /
    • v.30 no.1
    • /
    • pp.43-48
    • /
    • 2012
  • Purpose: To develop the dose volume histogram (DVH) management software which guides the evaluation of radiotherapy (RT) plan of a new case according to the biological consequences of the DVHs from the previously treated patients. Materials and Methods: We determined the radiation pneumonitis (RP) as an biological response parameter in order to develop DVH management software. We retrospectively reviewed the medical records of lung cancer patients treated with curative 3-dimensional conformal radiation therapy (3D-CRT). The biological event was defined as RP of the Radiation Therapy Oncology Group (RTOG) grade III or more. Results: The DVH management software consisted of three parts (pre-existing DVH database, graphical tool, and $Pinnacle^3$ script). The pre-existing DVH data were retrieved from 128 patients. RP events were tagged to the specific DVH data through retrospective review of patients' medical records. The graphical tool was developed to present the complication histogram derived from the preexisting database (DVH and RP) and was implemented into the radiation treatment planning (RTP) system, $Pinnacle^3$ v8.0 (Phillips Healthcare). The software was designed for the pre-existing database to be updated easily by tagging the specific DVH data with the new incidence of RP events at the time of patients' follow-up. Conclusion: We developed the DVH management software as an effective tool to incorporate the phenomenological consequences derived from the pre-existing database in the evaluation of a new RT plan. It can be used not only for lung cancer patients but also for the other disease site with different toxicity parameters.

Parecoxib: an Enhancer of Radiation Therapy for Colorectal Cancer

  • Xiong, Wei;Li, Wen-Hui;Jiang, Yong-Xin;Liu, Shan;Ai, Yi-Qin;Liu, Rong;Chang, Li;Zhang, Ming;Wang, Xiao-Li;Bai, Han;Wang, Hong;Zheng, Rui;Tan, Jing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.627-633
    • /
    • 2015
  • Background: To study the effect of parecoxib, a novel cyclooxygenase-2 selective inhibitor, on the radiation response of colorectal cancer (CRC) cells and its underlying mechanisms. Materials and Methods: Both in vitro colony formation and apoptosis assays as well as in vivo mouse xenograft experiments were used to explore the radiosensitizing effects of parecoxib in human HCT116 and HT29 CRC cells. Results: Parecoxib sensitized CRC cells to radiation in vitro with a sensitivity enhancement ratio of 1.32 for HCT116 cells and 1.15 for HT29 cells at a surviving fraction of 0.37. This effect was partially attributable to enhanced apoptosis induction by parecoxib combined with radiation, as illustrated using an in vitro apoptosis assays. Parecoxib augmented the tumor response of HCT116 xenografts to radiation, achieving growth delay more than 20 days and an enhancement factor of 1.53. In accordance with the in vitro results, parecoxib combined with radiation resulted in less proliferation and more apoptosis in tumors than radiation alone. Radiation monotherapy decreased microvessel density (MVD) and microvessel intensity (MVI), but increased the hypoxia level in xenografts. Parecoxib did not affect MVD, but it increased MVI and attenuated hypoxia. Conclusions: Parecoxib can effectively enhance radiation sensitivity in CRC cells through direct effects on tumor cells and indirect effects on tumor vasculature.

Radiological Characteristics of Materials Used in 3-Dimensional Printing with Various Infill Densities

  • Park, So-Yeon;Choi, Noorie;Choi, Byeong Geol;Lee, Dong Myung;Jang, Na Young
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.155-159
    • /
    • 2019
  • Radiological properties of newly introduced and existing 3-dimensional (3D) printing materials were evaluated by measuring their Hounsfield units (HUs) at varying infill densities. The six materials for 3D printing which consisted of acrylonitrile butadiene styrene (ABS), a unique ABS plastic blend manufactured by Zortrax (ULTRAT), high impact polystyrene (HIPS), polyethylene terephthalate glycol (PETG), polylactic acid (PLA), and a thermoplastic polyester elastomer manufactured by Zortrax (FLEX) were used. We used computed tomography (CT) imaging to determine the HU values of each material, and thus assess its suitability for various applications in radiation oncology. We found that several material and infill density combinations resembled the HU values of fat, soft tissues, and lungs; however, none of the tested materials exhibited HU values similar to that of bone. These results will help researchers and clinicians develop more appropriate instruments for improving the quality of radiation therapy. Using optimized infill densities will help improve the quality of radiation therapy by producing customized instruments for each field of radiation therapy.

The Clinical effectiveness and the radiation safety of newly developed Multileaf Collimator (새로 개발된 Multi-leaf Collimator의 임상 유효성 및 방사선 안전성에 관한 연구)

  • Yi, B.Y.;Kim, J.H.;Ahn, S.D.;Kim, M.H.;Chang, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.157-160
    • /
    • 1996
  • We have developed the prototype Multi-leaf Collimator(MLC) for medical linear acclerator. In this study, we have examined the clinical effectiveness of our newly developed MLC by analysing treatment pattern of radiation therapy and studied the radiation safety by measuring the transmitted radiation and the leakage radiation. Over 81% patients can be treated with new MLC(20 pairs of leaves) and 98% with 30 pairs of leafed-MLC, while 95% with commercial MLC. New MLC showed superior properties of radiation leakage and transmission to commercially available MLC.

  • PDF

Radiation risk perception and its associated factors among residents living near nuclear power plants: A nationwide survey in Korea

  • Sung, Hyoju;Kim, Jung Un;Lee, Dalnim;Jin, Young Woo;Jo, Hyemi;Jun, Jae Kwan;Park, Sunhoo;Seo, Songwon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1295-1300
    • /
    • 2022
  • There has been increased interest in researching risk perception of radiation to implement successful risk communication, particularly given the recent worldwide nuclear policy movement regarding nuclear energy. This study aimed to investigate characteristics of risk perception among residents living near normally operating nuclear power plants in South Korea by identifying factors associated with risk perception. A survey was conducted with face-to-face interviews for 1200 residents aged 20e84 years by gender- and age-stratified random sampling. Risk perception was associated with trust perception in nuclear safety, but was not highly correlated with benefit perception for utilizing nuclear power. Relatively high risk perception was observed in women, older age groups, and residents not having experience of nuclear-related education or work. This association remained after adjusting for other factors including benefit perception, trust perception, and psychological distress. In addition to these individual characteristics, risk perception was also associated with a residential district's own unique context, indicating that a strategy of risk communication should be developed differently for residents facing nuclear-related circumstances. Given that risk perception can be changed, depending on social values such as safety culture and economic setting, further studies are required to understand the changing characteristics of radiation risk perception.

Suppression of Ku80 Correlates with Radiosensitivity and Telomere Shortening in the U2OS Telomerase-negative Osteosarcoma Cell Line

  • Hu, Liu;Wu, Qin-Qin;Wang, Wen-Bo;Jiang, Huan-Gang;Yang, Lei;Liu, Yu;Yu, Hai-Jun;Xie, Cong-Hua;Zhou, Yun-Feng;Zhou, Fu-Xiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.2
    • /
    • pp.795-799
    • /
    • 2013
  • Ku70/80 heterodimer is a central element in the nonhomologous end joining (NHEJ) DNA repair pathway, Ku80 playing a key role in regulating the multiple functions of Ku proteins. It has been found that the Ku80 protein located at telomeres is a major contributor to radiosensitivity in some telomerase positive human cancer cells. However, in ALT human osteosarcoma cells, the precise function in radiosensitivity and telomere maintenance is still unknown. The aim of this study was to investigate the effects of Ku80 depletion in the U2OS ALT cell line cell line. Suppression of Ku80 expression was performed using a vector-based shRNA and stable Ku80 knockdown in cells was verified by Western blotting. U2OS cells treated with shRNA-Ku80 showed lower radiobiological parameters (D0, Dq and SF2) in clonogenic assays. Furthermore, shRNA-Ku80 vector transfected cells displayed shortening of the telomere length and showed less expression of TRF2 protein. These results demonstrated that down-regulation of Ku80 can sensitize ALT cells U2OS to radiation, and this radiosensitization is related to telomere length shortening.

Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

  • Joo, Ji Hyeon;Kim, Yeon Joo;Kim, Young Seok;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Su Ssan;Park, Jin-Hong;Jeong, Yuri;Ahn, Hanjong;Kim, Choung-Soo;Lee, Jae-Lyun;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.199-205
    • /
    • 2013
  • Purpose: To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Materials and Methods: Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. Results: The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. Conclusion: WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

Four-Dimensional Computed Tomography for Gated Radiotherapy: Retrospective Image Sorting and Evaluation

  • Lim, Sang-Wook;Park, Sung-Ho;Back, Geum-Mun;Ahn, Seung-Do;Shin, Seong-Soo;Lee, Sang-Wook;Kim, Jong-Hoon;Choi, Eun-Kyuong;Kwon, Soo-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.71-74
    • /
    • 2005
  • To introduce the four-dimensional computed tomography (4DCT, Light Speed RT, General Electric, USA) scanner newly installed in our department and evaluate its feasibility for gated radiotherapy. Respiratory signal measured by real-time position management (RPM$^{\circledR}$, Varian Medical, USA) was recorded in synchronization with the 4DCT scanner. 4DCT data were acquired in axial cine mode and sorted retrospective image based on respiratory phase. PTVs delineated from helical CT and 4DCT images were compared. The PTV delineated from conventional helical CT images was 2 cc larger than that from 4DCT images. Dose in PTV of the plan from retrospective CT was 99.3% (minimum=72.0%, maximum=106.5%) and that of helical CT plan was 95.2% (minimum=24.1%, maximum=106.4%) of prescribed dose. Comparing with DVHs of both plan, the coverage for 4CDT plan was 3.7% improved. It is expected that 4DCT could improve tumor control and reduce radiation toxicity for liver cancer.

  • PDF