• Title/Summary/Keyword: Medical radiation

Search Result 3,841, Processing Time 0.04 seconds

The Influence of Cancer Fatigue, Quality of Sleep, and Environmental Sleep Disturbance on Comfort in Hospitalized Cancer Patients (입원한 암환자의 암피로, 수면의 질 및 환경적 수면장애가 안위에 미치는 영향)

  • Kim, Hee-Jin;Chang, Hee-Kyung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.643-653
    • /
    • 2020
  • This study is a descriptive research study to identify the relationship between cancer fatigue, quality of sleep, environmental sleep disturbance, and comfort perceived by hospitalized cancer patients. Data were collected with structured questionnaires from 113 cancer patients from a university hospital in J city, Gyengnam, from September 17 to November 5, 2019, and analyzed using SPSS 21.0, using independent t-test, one-way ANOVA, Scheffé test, Pearson's correlation coefficient, and stepwise multiple regression. The subjects' Comfort is significantly different depending on education level, Cancerous type, Radiation treatment status, Usual exercise status. The result showed that comfort was negatively correlated with cancer fatigue(r=-.609, p<.001), quality of sleep(r=-.478, p<.001), and environmental sleep disturbance(r=-.297, p=.001). The variables that had a significant effect on comfort were cancer fatigue(β=-.42, p<.001), subjective quality of sleep(β=-.30, p=.001), and cancer type(β=-.18, p<.015), and the explanatory power was 46.1%(F=27.24, p<.001). Based on these results, it is necessary to develop a program to improve the quality of sleep and to reduce the cancer fatigue by cooperating with medical and nursing staff in multidisciplinary ways to enhance the comfort of hospitalized cancer patients.

Study on the Growth Environment of 'Gangwha-mugwort' Through the Climatological Characteristic Analysis of Gangwha Region (강화지역의 기후특성 분석을 통한 '강화약쑥'의 생육 환경 연구)

  • Ahn, Joong-Bae;Hur, Ji-Na;Jung, Hae-Gon;Park, Jong-Ho
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.2
    • /
    • pp.71-78
    • /
    • 2012
  • Eupatilin, one of representative medical components of mugwort, can be efficiently extracted from the 'Gangwha Sajabalssuk'. The Eupatilin content may depend on environmental factors such as soil and regional climate in addition to a genetic factor and Gangwha region has a profitable environmental condition for the mugwort growth. In this study, the climatological characteristics of Gangwha was analyzed in order to find the environmental condition of mugwort containing high Eupatilin in term of atmospheric, oceanographic and land variables. The climate of Gangwha is characterized by the relatively low daily temperature and large diurnal variation with plenty of solar radiation, long sunshine duration and less cloudiness. According to our correlation analysis, the long sunshine duration and the large diurnal temperature variation are highly correlated with the Eupatilin contents. The result implies that Gangwha has the favorable conditions for the cultivation and the habitat of the high-Eupatilin concentrated mugwort. Because of the sea surrounding Gangwha Island with low salinity and moderate wind, the salt contained in sea breeze is relatively low compared to other regions. Furthermore, Gangwha has clean atmospheric environment compared to other regions because the concentrations of toxic gases harmful to crop growth such as nitrogen dioxide ($NO_2$), sulfite gas ($SO_2$) and fine dust (PM-10) are lower in the air. The ozone ($O_3$) concentration is moderate and within the level of natural production. It is also found that moderately coarse texture or fine loamy soils known as good for water drainage and for the growth and cultivation of the 'Gangwha-mugwort' are distributed throughout the areas around mountainous districts in Gangwha, coinciding with those of mugwort habitat.

Generation, Storing and Management System for Electronic Discharge Summaries Using HL7 Clinical Document Architecture (HL7 표준임상문서구조를 사용한 전자퇴원요약의 생성, 저장, 관리 시스템)

  • Kim, Hwa-Sun;Kim, Il-Kon;Cho, Hune
    • Journal of KIISE:Databases
    • /
    • v.33 no.2
    • /
    • pp.239-249
    • /
    • 2006
  • Interoperability has been deemphasized from the hospital information system in general, because it is operated independently of other hospital information systems. This study proposes a future-oriented hospital information system through the design and actualization of the HL7 clinical document architecture. A clinical document is generated using the hospital information system by analysis and designing the clinical document architecture, after we defined the item regulations and the templates for the release form and radiation interpretation form. The schema is analyzed based on the HL7 reference information model, and HL7 interface engine ver.2.4 was used as the transmission protocol. This study has the following significance. First, an expansion and redefining process conducted, founded on the HL7 clinical document architecture and reference information model, to apply international standards to Korean contexts. Second, we propose a next-generation web based hospital information system that is based on the clinical document architecture. In conclusion, the study of the clinical document architecture will include an electronic health record (EHR) and a clinical data repository (CDR), and also make possible medical information-sharing among various healthcare institutions.

Hydroxyurea Treatment for Unresectable and Recurrent Meningiomas - Preliminary Report - (재발하였거나 수술적 제거가 불가능한 뇌수막종에 대한 Hydroxyurea 치료 - Preliminary Report -)

  • Lee, Jeong-Hwan;Kim, Oh-Lyong;Kim, Seong-Ho;Bae, Jang-Ho;Choi, Byung-Yon;Cho, Soo-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.120-123
    • /
    • 2001
  • Objectives : The present study was performed to analyze results of hydroxyurea treatment for unresectable and recurrent meningiomas as adjuvant chemotherapeutic agent. Material and Methods : Among 87 cases of meningioma patients who treated surgically between Jauary 1988 and December 1997 in our department, unresectable and recurrent cases were 4 cases. Histologically, 3 cases were meningothelial type, 1 case was angiomatous type. Tumor orgin was cerebellopontine angle(CPA) in 3 cases, cavernous sinus in 1 case. Three of 4 cases received radiation treatment. All patients received a daily dosage of 20mg/kg/day of hydroxyurea. Hematological monitorning was performed monthly and tumor measurement was assessed by MR imaging before treatment and every 6 months. Mean follow-up period was 34 months. Rerults : All cases showed no enlargement of tumor mass without any shrinkage. Trigeminal neuralgia in 1 case was improved and external herniation of brain on craniectomy site in 1 case was shrunken. None of the patients had any serious side effects. White blood cell count fell below $3000/{\mu}l$ in 1 case, but recovered 2 weeks later with cessation of medication. Conclusion : Hydroxyurea stopped cell growth by triggering the apoptotic cascade. Our preliminary data indicate that hydroxyurea provides adjuvant medical treatment in patients of unresectable and recurrent meningiomas

  • PDF

Neoadjuvant Chemotherapy and Prognosis of Pregnancy-Associated Breast Cancer: A Time-Trends Study of the Korean Breast Cancer Registry Database

  • Bae, Soo Youn;Kim, Ku Sang;Kim, Jeong-Soo;Lee, Sae Byul;Park, Byeong-Woo;Lee, Seok Won;Lee, Hyouk Jin;Kim, Hong Kyu;You, Ji-Young;Jung, Seung Pil;Korean Breast Cancer Society
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.425-432
    • /
    • 2018
  • Purpose: Pregnancy-associated breast cancer (PABC) is rare, and its cause and prognosis are not well known. Additionally, treatment is limited with respect to the risk to the fetus. The purpose of this study was to investigate the characteristics and treatment trends of PABC and the survival rate according to the treatment. Methods: In the Korean Breast Cancer Society Registry database, women younger than 50 years and who were diagnosed with breast cancer from 1996 to 2015 were included. PABC was defined as breast cancer diagnosed during pregnancy or within 1 year after delivery. Results: We examined 411 patients with PABC and 83,381 patients with non-PABC. Over time, the proportions of patients undergoing breast-conserving surgery and sentinel lymph node biopsy increased, and neoadjuvant chemotherapy and radiation therapy administration rates also increased. In the past, the overall survival of patients with PABC was poorer than that of patients with non-PABC, but there was no difference in overall survival rates in more recent years. There was no difference in overall survival rates between patients who received neoadjuvant chemotherapy (hazard ratio [HR], 1.28; 95% confidence interval [CI], 0.66-2.49; p=0.459), but PABC conferred poorer prognosis than non-PABC in patients receiving adjuvant chemotherapy (HR, 1.63; 95% CI, 1.27-2.08; p<0.001). Conclusion: There was no difference in the prognosis between patients with PABC and those with non-PABC receiving neoadjuvant chemotherapy. The increase in neoadjuvant chemotherapy according to current treatment guidelines is expected to improve the survival rate of patients with PABC.

A Suggestion for Counting Efficiency Management of the Automation Instrument (자동화장비 계측효율 관리적 측정방법 제안)

  • Park, Jun Mo;Kim, Han Chul;Choi, Seung Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2018
  • Purpose Quality control of instrument takes up a large part in the Radioimmunoassays. The gamma-ray instrument, which is one of the important instruments in the laboratory, observes the condition and performance of instrument and performs quality control of the instrument by measuring the Normalization, Calibration, Background and etc. However, there are some automation instruments which can't measure the counting efficiency of gamma-ray meters, resulting in insufficient management in terms of performance evaluation of gamma-ray meters. Therefore, the purpose of this paper is to manage the quality control continuously and regularly by suggesting how to measure the counting efficiency of gamma-ray instruments. Materials and Methods In case of a comparative measurement method to a gamma-ray instrument dedicated to nuclear medical examination, the CPM and counting efficiency can be obtained after the measurement of normalization by inserting the I-125 $200{\mu}L$(CPM 50,000~500,000) into the test tube. With this CPM and counting efficiency values, it's possible to calculate the measurement of the DPM value and count the CPM from the automation instrument from the same source, and enter the DPM to calculate the counting efficiency using a comparative measurement method. Another method is to calculate the counting efficiency by estimating the half life using the radiation source information of the tracer in B test reagents of company A. Results According to the calculation formula using the DPM obtained by counting the normalization of gamma-ray meters, the detection efficiency was 75.16% for Detector 1, 76.88% for Detector 2, 77.13% for Detector 3, 75.36% for Detector 4 and 73.2% for Detector 5 respectively. Using another calculation formula estimated from the shelf life, the data of the detection efficiency from Detector 1 to Detector 5 were 74.9%, 75.1%, 76.5%, 74.9% and 73.2% respectively. Conclusion Although the accuracy of counting efficiencies of both methods are insufficient, this is considered to be useful for ongoing management of quality control if counting efficiency is managed after setting the acceptable ranges. For example, if the measurement efficiency is set to 70% or higher, the allowed %difference between measurements is within 3% and the %difference with the detector wall is set within 5%.

Is the Spinal Instability Neoplastic Score Accurate and Reliable in Predicting Vertebral Compression Fractures for Spinal Metastasis? A Systematic Review and Qualitative Analysis

  • Lee, Chang-Hyun;Hong, Jae Taek;Lee, Sun-Ho;Yi, Seong;Sohn, Moon-Jun;Kim, Sung Hwan;Chung, Chun Kee;Korean Spine Oncology Research Society
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.4-12
    • /
    • 2021
  • Spinal metastases can present with varying degrees of mechanical instability. The Spinal Instability Neoplastic Score (SINS) was developed as a tool to assess spinal neoplastic-related instability while helping to guide referrals among oncology specialists. Some previous papers suggested that the SINS was accurate and reliable, while others disagreed with this opinion. We performed a systematic review regarding the SINS to evaluate its accuracy and precision in predicting vertebral compression fractures (VCFs). The 21 included studies investigated a total of 2118 patients. Thirteen studies dealt with the accuracy of SINS to predict post-radiotherapy VCFs, and eight dealt with the precision. Among 13 studies, 11 agreed that the SINS categories showed statistically significant accuracy in predicting VCF. Among eight studies, body collapse was effective for predicting VCFs in six studies, and alignment and bone lesion in two studies. Location has no statistical significance in predicting VCFs in any of the eight studies. The precision of SINS categories was substantial to excellent in six of eight studies. Among the six components of the SINS, the majority of the included studies reported that location showed near perfect agreement; body collapse, alignment, and posterolateral involvement showed moderate agreement; and bone lesion showed fair agreement. Bone lesion showed significant accuracy in predicting VCFs in half of eight studies, but displayed fair reliability in five of seven studies. Although location was indicated as having near perfect reliability, the component showed no accuracy for predicting VCFs in any of the studies and deleting or modifying the item needs to be considered. The SINS system may be accurate and reliable in predicting the occurrence of post-radiotherapy VCFs for spinal metastasis. Some components seem to be substantially weak and need to be revised.

Evaluation of Near-infrared Fluorescence-conjugated Peptides for Visualization of Human Epidermal Receptor 2-overexpressed Gastric Cancer

  • Jeong, Kyoungyun;Kong, Seong-Ho;Bae, Seong-Woo;Park, Cho Rong;Berlth, Felix;Shin, Jae Hwan;Lee, Yun-Sang;Youn, Hyewon;Koo, Eunhee;Suh, Yun-Suhk;Park, Do Joong;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.21 no.2
    • /
    • pp.191-202
    • /
    • 2021
  • Purpose: A near-infrared (NIR) fluorescence imaging is a promising tool for cancer-specific image guided surgery. Human epidermal receptor 2 (HER2) is one of the candidate markers for gastric cancer. In this study, we aimed to synthesize HER2-specific NIR fluorescence probes and evaluate their applicability in cancer-specific image-guided surgeries using an animal model. Materials and Methods: An NIR dye emitting light at 800 nm (IRDye800CW; Li-COR) was conjugated to trastuzumab and an HER2-specific affibody using a click mechanism. HER2 affinity was assessed using surface plasmon resonance. Gastric cancer cell lines (NCI-N87 and SNU-601) were subcutaneously implanted into female BALB/c nu (6-8 weeks old) mice. After intravenous injection of the probes, biodistribution and fluorescence signal intensity were measured using Lumina II (Perkin Elmer) and a laparoscopic NIR camera (InTheSmart). Results: Trastuzumab-IRDye800CW exhibited high affinity for HER2 (KD=2.093(3) pM). Fluorescence signals in the liver and spleen were the highest at 24 hours post injection, while the signal in HER2-positive tumor cells increased until 72 hours, as assessed using the Lumina II system. The signal corresponding to the tumor was visually identified and clearly differentiated from the liver after 72 hours using a laparoscopic NIR camera. Affibody-IRDye800CW also exhibited high affinity for HER2 (KD=4.71 nM); however, the signal was not identified in the tumor, probably owing to rapid renal clearance. Conclusions: Trastuzumab-IRDye800CW may be used as a potential NIR probe that can be injected 2-3 days before surgery to obtain high HER2-specific signal and contrast. Affibody-based NIR probes may require modifications to enhance mobilization to the tumor site.

Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method (블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교)

  • Shim, Jina;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.301-306
    • /
    • 2021
  • The use of tin filters as a way to reduce the medical radiation in computed tomography (CT). However, due to the changed X-ray spectrum with the use of tin filters, disease diagnosis could be affected because it appears as images of different impressions from previous images. Therefore, this study evaluates the changes in images when using tin filter and high pitch in chest low-dose CT. In this study, images were acquired in groups of three for comparison. Group 1 did not apply to tin filter, and used the existing pitch 0.8. Group 2 used a tin filter, pitch 0.8, Group 3 used a tin filter, and pitch 2.5. To compare the image quality, the natural image quality evaluator (NIQE) and the blind/referenceless image quality evaluator (BRISQUE) were used among the blind quality evaluation factors depended on a no-reference basis. As a result, the NIQE values were low in the order of Group 1, Group 3, and Group 2. BRISQUE values were low in the order of Group 3, Group 2 and Group 1. This study confirms the superiority of images of tin filter and high pitch techniques in chest low-dose CT, which is considered to be a fundamental study for acquiring accurate images of patients with difficult breathing control.

Artifact Reduction in Sparse-view Computed Tomography Image using Residual Learning Combined with Wavelet Transformation (Wavelet 변환과 결합한 잔차 학습을 이용한 희박뷰 전산화단층영상의 인공물 감소)

  • Lee, Seungwan
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.295-302
    • /
    • 2022
  • Sparse-view computed tomography (CT) imaging technique is able to reduce radiation dose, ensure the uniformity of image characteristics among projections and suppress noise. However, the reconstructed images obtained by the sparse-view CT imaging technique suffer from severe artifacts, resulting in the distortion of image quality and internal structures. In this study, we proposed a convolutional neural network (CNN) with wavelet transformation and residual learning for reducing artifacts in sparse-view CT image, and the performance of the trained model was quantitatively analyzed. The CNN consisted of wavelet transformation, convolutional and inverse wavelet transformation layers, and input and output images were configured as sparse-view CT images and residual images, respectively. For training the CNN, the loss function was calculated by using mean squared error (MSE), and the Adam function was used as an optimizer. Result images were obtained by subtracting the residual images, which were predicted by the trained model, from sparse-view CT images. The quantitative accuracy of the result images were measured in terms of peak signal-to-noise ratio (PSNR) and structural similarity (SSIM). The results showed that the trained model is able to improve the spatial resolution of the result images as well as reduce artifacts in sparse-view CT images effectively. Also, the trained model increased the PSNR and SSIM by 8.18% and 19.71% in comparison to the imaging model trained without wavelet transformation and residual learning, respectively. Therefore, the imaging model proposed in this study can restore the image quality of sparse-view CT image by reducing artifacts, improving spatial resolution and quantitative accuracy.